Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Magn Reson Med ; 83(5): 1774-1782, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31654446

RESUMO

PURPOSE: The objective of this study is to evaluate the suitability and performance of ultra-short echo time (UTE) sequences for imaging and quantifying the deposition of nebulized MRI contrast agents in human-sized lungs. METHODS: Nebulization of clinically used contrast agent or gadolinium-based nanoparticles were performed using a commercial jet nebulizer in isolated and ventilated porcine lungs connected to a 3D-printed human upper airways replica. MR images of isolated lungs were acquired on a 3T clinical MR scanner using 3D UTE sequences at different flip angles. RESULTS: 3D acquisitions with isotropic millimetric resolution were obtained in less than 4 min. Images exhibit homogeneous and large MR signal enhancement (above 200%) following nebulization of both types of aerosols. Deposition of aerosol down to the level of the bronchi of secondary lobules was visualized. T1 values and the concentration of nanoparticles obtained by MRI were found to correlate with the amount of nebulized gadolinium3+ ions. CONCLUSION: The distribution of aerosolized gadolinium-based contrast agent or nanoparticles can be visualized and quantified using UTE MRI in large animal ventilated lung model on a clinical MRI scanner. This protocol can be used for assessing and quantifying aerosol regional deposition with high spatial resolution (1 mm 3D isotropic) without ionizing radiation and could be applied in the future for diagnostic or therapeutic applications in patients.


Assuntos
Meios de Contraste , Nanopartículas , Animais , Gadolínio , Humanos , Imageamento Tridimensional , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Suínos
2.
Sci Rep ; 13(1): 11056, 2023 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-37422519

RESUMO

Successful aerosol therapy in mechanically ventilated patients depends on multiple factors. Among these, position of nebulizer in ventilator circuit and humidification of inhaled gases can strongly influence the amount of drug deposited in airways. Indeed, the main objective was to preclinically evaluate impact of gas humidification and nebulizer position during invasive mechanical ventilation on whole lung and regional aerosol deposition and losses. Ex vivo porcine respiratory tracts were ventilated in controlled volumetric mode. Two conditions of relative humidity and temperature of inhaled gases were investigated. For each condition, four different positions of vibrating mesh nebulizer were studied: (i) next to the ventilator, (ii) right before humidifier, (iii) 15 cm to the Y-piece adapter and (iv) right after the Y-piece. Aerosol size distribution were calculated using cascade impactor. Nebulized dose, lung regional deposition and losses were assessed by scintigraphy using 99mtechnetium-labeled diethylene-triamine-penta-acetic acid. Mean nebulized dose was 95% ± 6%. For dry conditions, the mean respiratory tract deposited fractions reached 18% (± 4%) next to ventilator and 53% (± 4%) for proximal position. For humidified conditions, it reached 25% (± 3%) prior humidifier, 57% (± 8%) before Y-piece and 43% (± 11%) after this latter. Optimal nebulizer position is proximal before the Y-piece adapter showing a more than two-fold higher lung dose than positions next to the ventilator. Dry conditions are more likely to cause peripheral deposition of aerosols in the lungs. But gas humidification appears hard to interrupt efficiently and safely in clinical use. Considering the impact of optimized positioning, this study argues to maintain humidification.


Assuntos
Ventilação não Invasiva , Animais , Suínos , Broncodilatadores , Nebulizadores e Vaporizadores , Aerossóis , Pulmão/diagnóstico por imagem , Administração por Inalação , Respiração Artificial , Gases , Desenho de Equipamento , Albuterol
3.
Sci Rep ; 12(1): 1188, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35075199

RESUMO

As a result of the current COVID-19 pandemic, the use of facemasks has become commonplace. The performance of medical facemasks is assessed using Bacterial Filtration Efficiency (BFE) tests. However, as BFE tests, require specific expertise and equipment and are time-consuming, the performance of non-medical facemasks is assessed with non-biological Particle Filtration Efficiency (PFE) tests which are comparatively easier to implement. It is necessary to better understand the possible correlations between BFE and PFE to be able to compare the performances of the different types of masks (medical vs. non-medical). In this study BFE results obtained in accordance with the standard EN 14683 are compared to the results of PFE from a reference test protocol defined by AFNOR SPEC S76-001 with the aim to determine if BFE could be predicted from PFE. Our results showed a correlation between PFE and BFE. It was also observed that PFE values were higher than BFE and this was attributed to the difference in particle size distribution considered for efficiency calculation. In order to properly compare these test protocols for a better deduction, it would be interesting to compare the filtration efficiency for a similar granulometric range.


Assuntos
COVID-19/prevenção & controle , Máscaras , Pandemias/prevenção & controle , SARS-CoV-2 , Filtração , Humanos , Tamanho da Partícula
4.
Chemosphere ; 288(Pt 1): 132364, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34600007

RESUMO

The need for personal protective equipment increased exponentially in response to the Covid-19 pandemic. To cope with the mask shortage during springtime 2020, a French consortium was created to find ways to reuse medical and respiratory masks in healthcare departments. The consortium addressed the complex context of the balance between cleaning medical masks in a way that maintains their safety and functionality for reuse, with the environmental advantage to manage medical disposable waste despite the current mask designation as single-use by the regulatory frameworks. We report a Workflow that provides a quantitative basis to determine the safety and efficacy of a medical mask that is decontaminated for reuse. The type IIR polypropylene medical masks can be washed up to 10 times, washed 5 times and autoclaved 5 times, or washed then sterilized with radiations or ethylene oxide, without any degradation of their filtration or breathability properties. There is loss of the anti-projection properties. The Workflow rendered the medical masks to comply to the AFNOR S76-001 standard as "type 1 non-sanitory usage masks". This qualification gives a legal status to the Workflow-treated masks and allows recommendation for the reuse of washed medical masks by the general population, with the significant public health advantage of providing better protection than cloth-tissue masks. Additionally, such a legal status provides a basis to perform a clinical trial to test the masks in real conditions, with full compliance with EN 14683 norm, for collective reuse. The rational reuse of medical mask and their end-of-life management is critical, particularly in pandemic periods when decisive turns can be taken. The reuse of masks in the general population, in industries, or in hospitals (but not for surgery) has significant advantages for the management of waste without degrading the safety of individuals wearing reused masks.


Assuntos
COVID-19 , Pandemias , Humanos , Máscaras , Equipamento de Proteção Individual , SARS-CoV-2
5.
Sci Rep ; 11(1): 5887, 2021 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-33723303

RESUMO

Based on the current knowledge of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) transmission, wearing a mask has been recommended during the COVID-19 pandemic. Bacterial filtration efficiency (BFE) measurements enable designing and regulating medical masks to prevent bioaerosol dissemination; however, despite the simplicity of these measurements, several scientific questions remain unanswered regarding BFE tests. Here, we investigated (1) the impact of substituting 100-mm Petri dishes with 90-mm disposable Petri dishes, (2) the impact of colony-counting methods on the bioaerosol aerodynamic size, and (3) the impact of colony-counting methods on the total viable particle counts. We demonstrated that disposable 90-mm Petri dishes can be used to replace the 100-mm dishes. We also showed that an automatic high-resolution colony counter can be used to directly count viable particles on collection substrates and to measure the bioaerosol size parameters. Our results enable possible modernization of the outdated testing methods recommended in the US and European standards for BFE measurements. Specifically, use of a modernized colony counter should be clearly regulated and permitted to avoid the counting of positive holes. The median aerodynamic diameter appears to be the most relevant parameter for characterizing bioaerosol size.


Assuntos
Bactérias , Filtração/normas , Máscaras/normas , Carga Bacteriana , Microbiologia Ambiental , Filtração/métodos , Humanos , Máscaras/microbiologia , Tamanho da Partícula , Porosidade
6.
Int J Nanomedicine ; 15: 7251-7262, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33061379

RESUMO

PURPOSE: This study aims at determining lung distribution of gadolinium-based polysiloxane nanoparticles, AGuIX® (small rigid platform - SRP), as a potential theranostic approach by the pulmonary route. METHODS: First, the aerodynamic size distribution and the aerosol output rate were thoroughly characterized. Then, a multimodal approach using magnetic resonance (MR) and gamma-camera (GC) imaging allows to assess the deposition of the aerosolised nanoparticles in the respiratory tract using isolated ventilated porcine lungs. RESULTS: The SRP has proven to be radiolabelled by radioisotope with a good yield. Crude SRP or radiolabelled ones showed the same aerodynamic size distribution and output as a conventional molecular tracer, as sodium fluoride. With MR and GC imaging approaches, the nebulised dose represented about 50% of the initial dose of nanoparticles placed in the nebuliser. Results expressed as proportions of the deposited aerosol showed approximately a regional aerosol deposition of 50% of the deposited dose in the lungs and 50% in the upper airways. Each technique assessed a homogeneous pattern of deposited nanoparticles in Lungs. MR observed a strong signal enhancement with the SRP, similar to the one obtained with a commonly used MRI contrast agent, gadoterate meglumine. CONCLUSION: As a known theranostic approach by intravenous administration, SRP appeared to be easily aerosolised with a conventional nebuliser. The present work proves that pulmonary administration of SRP is feasible in a human-like model and allows multimodal imaging with MR and GC imaging. This work presents the proof of concept of SRP nebulisation and aims to generate preclinical data for the potential clinical transfer of SRP for pulmonary delivery.


Assuntos
Gadolínio/administração & dosagem , Gadolínio/farmacocinética , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Nebulizadores e Vaporizadores , Cintilografia/métodos , Aerossóis/administração & dosagem , Aerossóis/farmacocinética , Animais , Meios de Contraste/química , Meios de Contraste/uso terapêutico , Humanos , Pulmão/efeitos dos fármacos , Meglumina/química , Meglumina/uso terapêutico , Nanopartículas Metálicas/administração & dosagem , Técnicas de Cultura de Órgãos , Compostos Organometálicos/química , Compostos Organometálicos/uso terapêutico , Medicina de Precisão , Respiração Artificial , Suínos
7.
Sci Rep ; 9(1): 5720, 2019 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-30952897

RESUMO

Ethical restrictions are limitations of in vivo inhalation studies, on humans and animal models. Thus, in vitro or ex vivo anatomical models offer an interesting alternative if limitations are clearly identified and if extrapolation to human is made with caution. This work aimed to develop an ex vivo infant-like respiratory model of bronchopulmonary dysplasia easy to use, reliable and relevant compared to in vivo infant data. This model is composed of a 3D-printed head connected to a sealed enclosure containing a leporine thorax. Physiological data and pleural-mimicking depressions were measured for chosen respiratory rates. Homogeneity of ventilation was assessed by 81mkrypton scintigraphies. Regional radioaerosol deposition was quantified with 99mtechnetium-diethylene triamine pentaacetic acid after jet nebulization. Tidal volumes values are ranged from 33.16 ± 7.37 to 37.44 ± 7.43 mL and compliance values from 1.78 ± 0.65 to 1.85 ± 0.99 mL/cmH2O. Ventilation scintigraphies showed a homogenous ventilation with asymmetric repartition: 56.94% ± 9.4% in right lung and 42.83% ± 9.36 in left lung. Regional aerosol deposition in lungs exerted 2.60% ± 2.24% of initial load of radioactivity. To conclude the anatomical model satisfactorily mimic a 3-months old BPD-suffering bronchopulmonary dysplasia and can be an interesting tool for aerosol regional deposition studies.


Assuntos
Displasia Broncopulmonar/fisiopatologia , Pulmão/fisiopatologia , Ventilação Pulmonar/fisiologia , Respiração , Aerossóis , Humanos , Recém-Nascido , Modelos Anatômicos , Impressão Tridimensional , Volume de Ventilação Pulmonar/fisiologia
8.
Sci Rep ; 9(1): 17930, 2019 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-31784627

RESUMO

In intensive care units, nebulization is a usual route for drug administration to patients under mechanical ventilation (MV). The effectiveness of inhalation devices as well as depositions sites of aerosols for ventilated patients remain poorly documented. In vivo human inhalation studies are scarce due to ethical restrictions because imaging techniques require radioaerosols to assess regional aerosol deposition. Thus, we developed an ex vivo respiratory model under invasive MV for preclinical aerosol deposition studies. The model was composed of ex vivo porcine respiratory tracts. MV was achieved thanks to a tracheal intubation and a medical ventilator under controlled conditions. Respiratory features were studied using analogical sensors. Then regional homogeneity of gas-ventilation was assessed with 81mKrypton scintigraphies. Finally, a proof of concept study for aerosol deposition was performed. Obtained respiratory features as well as gamma-imaging techniques, which demonstrated a homogenous regional ventilation and about 18% ± 4% of the nebulized dose deposited the respiratory tract, were in good agreement with human data available in the literature. This original ex vivo respiratory model provides a feasible, reproducible and cost-effective preclinical tool to achieve aerosol deposition studies under MV.


Assuntos
Aerossóis/administração & dosagem , Respiração Artificial , Administração por Inalação , Aerossóis/farmacocinética , Animais , Modelos Anatômicos , Modelos Biológicos , Nebulizadores e Vaporizadores , Respiração , Sistema Respiratório/anatomia & histologia , Sistema Respiratório/metabolismo , Suínos
9.
Sci Rep ; 9(1): 17949, 2019 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-31784683

RESUMO

Idiopathic pulmonary fibrosis is a progressive disease with unsatisfactory systemic treatments. Aerosol drug delivery to the lungs is expected to be an interesting route of administration. However, due to the alterations of lung compliance caused by fibrosis, local delivery remains challenging. This work aimed to develop a practical, relevant and ethically less restricted ex vivo respiratory model of fibrotic lung for regional aerosol deposition studies. This model is composed of an Ear-Nose-Throat replica connected to a sealed enclosure containing an ex vivo porcine respiratory tract, which was modified to mimic the mechanical properties of fibrotic lung parenchyma - i.e. reduced compliance. Passive respiratory mechanics were measured. 81mKr scintigraphies were used to assess the homogeneity of gas-ventilation, while regional aerosol deposition was assessed with 99mTc-DTPA scintigraphies. We validated the procedure to induce modifications of lung parenchyma to obtain aimed variation of compliance. Compared to the healthy model, lung respiratory mechanics were modified to the same extent as IPF-suffering patients. 81mKr gas-ventilation and 99mTc-DTPA regional aerosol deposition showed results comparable to clinical studies, qualitatively. This ex vivo respiratory model could simulate lung fibrosis for aerosol regional deposition studies giving an interesting alternative to animal experiments, accelerating and facilitating preclinical studies before clinical trials.


Assuntos
Aerossóis/administração & dosagem , Fibrose Pulmonar Idiopática/fisiopatologia , Pulmão/fisiopatologia , Administração por Inalação , Aerossóis/farmacocinética , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Humanos , Fibrose Pulmonar Idiopática/tratamento farmacológico , Pulmão/efeitos dos fármacos , Respiração/efeitos dos fármacos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Suínos , Pentetato de Tecnécio Tc 99m/análise
10.
Int J Pharm ; 551(1-2): 322-328, 2018 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30236645

RESUMO

Acriflavine (ACF) hydrochloride is currently repurposed as multimodal drug, inhibiting hypoxia-inducible factors (HIF) pathways and exerting cytotoxic properties. The aim of this study was to encapsulate ACF in reverse micelles and to incorporate this suspension in lipid nanocapsules (LNC). Designs of experiments were used to work under quality by design conditions. LNC were formulated using a phase-inversion temperature method, leading to an encapsulation efficiency around 80%. In vitro, the encapsulated drug presented similar cytotoxic activity and decrease in HIF activity in 4T1 cells compared to the free drug. In vivo, ACF-loaded nanoparticles (ACF dose of 5 mg/kg) demonstrated a higher antitumor efficacy compared to free ACF on an orthotopic model of murine breast cancer (4T1 cells). Moreover, the use of LNC allowed to drastically decrease the number of administrations compared to the free drug (2 versus 12 injections), suppressing the ACF-induced toxicity.


Assuntos
Acriflavina/administração & dosagem , Portadores de Fármacos/administração & dosagem , Fator 1 Induzível por Hipóxia/antagonistas & inibidores , Lipídeos/administração & dosagem , Neoplasias Mamárias Experimentais/tratamento farmacológico , Nanocápsulas/administração & dosagem , Animais , Linhagem Celular Tumoral , Feminino , Camundongos , Camundongos Endogâmicos BALB C
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA