Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 158
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ophthalmic Physiol Opt ; 44(4): 774-786, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38578134

RESUMO

PURPOSE: To investigate gaze and behavioural metrics at different viewing distances with multifocal contact lenses (MFCLs), single vision contact lenses (SVCLs) and progressive addition lenses (PALs). METHODS: Fifteen presbyopic contact lens wearers participated over five separate study visits. At each visit, participants were randomly assigned to wear one of five refractive corrections: habitual PAL spectacles, delefilcon A (Alcon Inc.) MFCLs and three separate pairs of delefilcon A single vision lenses worn as distance, intermediate and near corrections. Participants wore a Pupil Core headset to record eye and head movements while performing three visual tasks: reading, visual search and scene observation. Data were investigated using linear regression and post-hoc testing. Parameters of interest included gaze (fixation duration, head movement) and behavioural (reading speed, reading accuracy, visual search time) metrics. RESULTS: Reading speed in SVCLs was significantly faster than in MFCLs and PAL spectacles (F = 16.3, p < 0.0001). Refractive correction worn did not influence visual search times (F = 0.16, p = 0.85). Fixation duration was significantly affected by the type of visual task (F = 60.2, p < 0.001), and an interaction effect was observed between viewing distance and refractive correction (F = 4.3, p = 0.002). There was significantly more horizontal and vertical head movement (F = 3.2, p = 0.01 and F = 3.3, p = 0.01, respectively) during visual search tasks when wearing PAL spectacles compared to SVCLs or MFCLs. CONCLUSION: This work showed that the type of refractive correction affects behavioural metrics such as reading speed and gaze behaviour by affecting horizontal and vertical head movements. The findings of this study suggest that under certain conditions, wearers of MFCLs make fewer head movements compared to PAL spectacles. Gaze behaviour metrics offer a new approach to compare and understand contact lens and spectacle performance, with potential applications including peripheral optical designs for myopia management.


Assuntos
Lentes de Contato , Óculos , Fixação Ocular , Presbiopia , Leitura , Refração Ocular , Acuidade Visual , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimentos Oculares/fisiologia , Fixação Ocular/fisiologia , Movimentos da Cabeça/fisiologia , Presbiopia/fisiopatologia , Presbiopia/terapia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Estudos Cross-Over , Estudos Prospectivos
2.
Ophthalmic Physiol Opt ; 44(4): 704-717, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38546401

RESUMO

PURPOSE: To investigate differences in key clinical parameters between asymptomatic and highly symptomatic soft contact lens (CL) wearers after 14 h of wear. METHODS: In this pilot investigation, Phase 1 identified asymptomatic (CLDEQ-8 score ≤ 7) and highly symptomatic (CLDEQ-8 score ≥ 20) subjects after fitting with nelfilcon A CLs. Phase 2 investigated the following over a single nelfilcon A CL-wearing day (14 ± 2 h): blinking characteristics, tear meniscus height (TMH), non-invasive tear break-up time (NIBUT), tear film osmolarity and eyelid margin staining. Parameters for the two groups were compared using linear mixed models and post-hoc testing. The relationship between comfort scores and the clinical parameters was also investigated. RESULTS: Overall, 161 and 42 subjects were enrolled into Phase 1 and 2, respectively. Twenty-five asymptomatic and 17 symptomatic subjects completed Phase 2. Lower eyelid TMH was decreased after 14 h in symptomatic compared with asymptomatic subjects (least square mean [LSM] difference -0.04 mm, 95% CI: -0.07, -0.01). Osmolarity was lower in symptomatic than in asymptomatic subjects at fitting (LSM difference -9.89, 95% CI: -18.91, -0.86). Upper eyelid margin staining was greater after 14 h in symptomatic than in asymptomatic subjects (LSM difference 0.53, 95% CI: 0.01, 1.05) and greater after 14 h than baseline in the symptomatic group (LSM difference 0.61, 95% CI: 0.16, 1.07). There was a significant relationship between comfort and upper eyelid margin staining (r = -0.40, 95% CI: -0.63, -0.11) and blink rate (r = -0.31, 95% CI: -0.57, -0.003). CONCLUSION: The potential parameters most effective in differentiating asymptomatic from symptomatic wearers were upper eyelid margin staining and lower TMH. The parameter with the strongest relationship to comfort was upper eyelid margin staining, where higher comfort scores were associated with lower levels of staining.


Assuntos
Piscadela , Lentes de Contato Hidrofílicas , Lágrimas , Humanos , Lentes de Contato Hidrofílicas/efeitos adversos , Masculino , Feminino , Adulto , Lágrimas/metabolismo , Lágrimas/fisiologia , Projetos Piloto , Piscadela/fisiologia , Adulto Jovem , Concentração Osmolar , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/fisiopatologia , Pálpebras
3.
Ophthalmic Physiol Opt ; 44(5): 894-909, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38708449

RESUMO

PURPOSE: To investigate whether there is a measurable change in meibomian gland morphological characteristics over the course of a day (12 h) and over a month. METHODS: The study enrolled 15 participants who attended a total of 11 study visits spanning a 5-week period. To assess diurnal changes in meibomian glands, seven visits were conducted on a single day, each 2 h apart. For monthly assessment, participants attended an additional visit at the same time of the day every week for three consecutive weeks. Meibography using the LipiView® II system was performed at each visit, and meibomian gland morphological parameters were calculated using custom semi-automated software. Specifically, six central glands were analysed for gland length ratio, gland width, gland area, gland intensity and gland tortuosity. RESULTS: The average meibomian gland morphological metrics did not exhibit significant changes during the course of a day or over a month. Nonetheless, certain individual gland metrics demonstrated notable variation over time, both diurnally and monthly. Specifically, meibomian gland length ratio, area, width and tortuosity exhibited significant changes both diurnally and monthly when assessed on a gland-by-gland basis. CONCLUSIONS: Meibomian glands demonstrated measurable structural change over short periods of time (hours and days). These results have implications for innovation in gland imaging and for developing precision monitoring of gland structure to assess meibomian gland health more accurately.


Assuntos
Glândulas Tarsais , Humanos , Glândulas Tarsais/diagnóstico por imagem , Glândulas Tarsais/anatomia & histologia , Projetos Piloto , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Disfunção da Glândula Tarsal/diagnóstico , Disfunção da Glândula Tarsal/diagnóstico por imagem , Lágrimas/fisiologia , Ritmo Circadiano/fisiologia , Fatores de Tempo
4.
Eye Contact Lens ; 48(11): 455-459, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36083156

RESUMO

OBJECTIVES: To assess the impact of national affluence on the extent of prescribing of various types of soft contact lenses. METHODS: Using information derived from a large bank of contact lens prescribing data, the relationship between the percentage prescribing of daily disposable, toric, silicone hydrogel, and multifocal contact lenses versus the gross domestic product at purchasing parity per capita (GDP [PPP]) was determined for all countries in which contact lens prescribers returned survey forms relating to greater than 100 contact lens fits between 2017 and 2021, inclusive. RESULTS: Data from 39 countries were analyzed, comprising 94,181 contact lens fits. The relationship between percentage contact lens prescribing versus GDP (PPP) was highly statistically significant for daily disposable lenses (r 2 =0.35, P <0.0001), marginally significant for toric lenses (r 2 =0.08, P =0.06), and not significant for silicone hydrogel lenses (r 2 =0.01, P =0.42) or multifocal lenses (r 2 =0.02, P =0.35). CONCLUSIONS: The rate of prescribing daily disposable contact lenses, and to a lesser extent toric lenses, is related to national affluence. The contact lens industry, practitioners, and governments/regulatory bodies should remain cognizant of this association and, where possible, reduce cost barriers to the purchase of such contact lens products so that they can be prescribed based on important clinical, refraction, and lifestyle considerations.


Assuntos
Lentes de Contato Hidrofílicas , Optometria , Humanos , Prescrições , Silicones , Hidrogéis
5.
Int J Mol Sci ; 23(17)2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-36077001

RESUMO

Meibomian gland orifices (MGOs) are located along the eyelid margin and secrete meibum into the tear film. The profile of resident innate immune cells (ICs) at this site is not well understood. The distribution and phenotype of resident ICs around MGOs in mice was investigated and herein defined as MGO-associated immune cells (MOICs). The effect of topical 0.1% benzalkonium chloride (BAK) on MOICs was also assessed. Eyelids from healthy CD11ceYFP and Cx3cr1gfp/gfp mice aged three or seven months were compared. ICs were identified as CD11c+, Cx3cr1+, and MHC-II+ using four-colour immunostaining and confocal microscopy. MOIC density was variable but clustered around MGOs. There were more CD11c+ MOICs in three-month-old compared with seven-month-old mice (three-month-old: 893 ± 449 cells/mm2 vs. seven-month-old: 593 ± 493 cells/mm2, p = 0.004). Along the eyelid margin, there was a decreasing gradient of CD11c+ MOIC density in three-month-old mice (nasal: 1003 ± 369 cells/mm2, vs. central: 946 ± 574 cells/mm2, vs. temporal: 731 ± 353 cells/mm2, p = 0.044). Cx3cr1-deficient mice had two-fold fewer MHC-II+ MOICs, suggesting a role for Cx3cr1 receptor signaling in meibomian gland surveillance. CD11c+ MOIC density was lower in BAK-exposed eyes compared to saline-treated controls, suggesting a change in homeostasis. This study provides novel insight into resident ICs located at MGOs, and their contribution to MG homeostasis.


Assuntos
Doenças Palpebrais , Glândulas Tarsais , Animais , Compostos de Benzalcônio/farmacologia , Camundongos , Fenótipo , Lágrimas
6.
Optom Vis Sci ; 98(9): 1039-1044, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34469928

RESUMO

SIGNIFICANCE: Identification of the most impactful articles, authors, institutions, countries, and journals in myopia management provides a useful baseline reference for clinicians, researchers, and funding agencies in respect of this emerging field.This work aims to assemble publication metrics for myopia management to identify the most impactful articles, authors, institutions, countries, and journals in this emerging field of research. A search of the titles of articles was undertaken on the Scopus database to identify myopia management-related articles. The 25 most highly cited articles were determined from the total list of 1064 articles found. Rank-order lists by count were assembled for the top 25 in each of four categories: authors, institutions, countries, and journals. A subject-specific myopia management-related h-index (hMM-index) was derived for the entire field, in addition to each of the four categories, to serve as measures of impact in the field. Top 15 lists were generated for each category ranked by hMM-index and tabulated for consideration. An article by Christine Wildsoet and colleagues, describing choroidal and scleral mechanisms of compensation for spectacle lenses in chicks, has generated the most citations (412); Earl Smith is the most impactful author (hMM = 19); the University of Houston produces the most impactful articles (hMM = 31); the United States is the most highly ranked country (hMM = 60); and Optometry and Vision Science is the most impactful journal. Although still in its infancy, myopia management is a topic of emerging interest in the clinical and scientific ophthalmic literature. Impactful authors, institutions, countries, and journals are identified. Optometry is revealed as the leading profession in relation to the publication of myopia management-related articles.


Assuntos
Miopia , Optometria , Bibliometria , Humanos , Miopia/diagnóstico , Miopia/terapia , Estados Unidos
7.
Ophthalmic Physiol Opt ; 41(3): 603-609, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33609327

RESUMO

The World Health Organization has identified a shortage of trained human resources as one of the greatest challenges to increasing the availability of eye care services and reducing preventable visual impairment around the world. Increased prevalence of myopia and new strategies for myopia management have raised the prospect of various interventions, including contact lenses for therapeutic use as well as for refractive correction. More personnel skilled in contact lens fitting will be needed to address potential worldwide demand for these interventions. This review investigates the current status and future requirements of global contact lens education in light of these developments. The COVD-19 pandemic led educational institutions worldwide to move towards online delivery. An online survey among 546 educators, conducted in May 2020, investigated changes to contact lens education delivery before and after the onset of the pandemic. A total of 214 responses were received from 32 countries. Prior to COVID-19 restrictions, 23% of educators had conducted more than 50% of their total teaching online; however, 69% expected to conduct more than half of their teaching online by the end of 2020 and 12% anticipated 90% or more of their teaching would be online. Some 76% of educators expected to provide more online lectures after the pandemic and 63% anticipated new methods to deliver practical education. Around half were planning to introduce new teaching online platforms (54%) and more online assessment methods (53%). The global need for increasing numbers of skilled personnel points to a crucial role for educators in teaching the contact lens practitioners of the future. Contact lens education delivery was already evolving prior to COVID-19, and changes that are currently occurring may lead to permanent differences in the way contact lenses are taught in future. The International Association of Contact Lens Educators (IACLE) provides educators with a standardised global curriculum, online resources and teaching technology that could also serve as a model for wider ophthalmic education in future.


Assuntos
COVID-19/epidemiologia , Lentes de Contato , Educadores em Saúde/tendências , Optometria/educação , Prática Profissional/tendências , Ajuste de Prótese , SARS-CoV-2 , COVID-19/prevenção & controle , Infecção Hospitalar/prevenção & controle , Transmissão de Doença Infecciosa/prevenção & controle , Pesquisas sobre Atenção à Saúde , Humanos , Controle de Infecções/métodos , Miopia/terapia , Optometria/tendências , Telemedicina/métodos
8.
Ophthalmic Physiol Opt ; 40(4): 519-528, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32452570

RESUMO

PURPOSE: Development and validation of a non-invasive imaging system to capture spontaneous blinking and characterise blink dynamics using a custom image analysis algorithm. METHODS: A pilot study investigated the influence of illumination type on blink dynamics. Spontaneous blinking was recorded in eight subjects using a high-speed camera under two illumination conditions: white light and infrared. Custom semi-automated software assessed palpebral aperture height (PAH), blink rate, blink speed, blink completeness and blink duration. The main clinical study compared two different image analysis techniques. Spontaneous blinking was recorded in 20 subjects using a high-speed infrared camera. Blink speed and duration were determined using two techniques: manual tracking and semi-automated tracking. Agreement between the two techniques was assessed using Bland-Altman analysis. Coefficients of repeatability (COR) were calculated for the semi-automated technique. RESULTS: There were significant differences between white light and infrared illumination for PAH (p < 0.0001), blink rate (p = 0.04), closing speed (p = 0.009), opening speed (p < 0.0001) and blink duration (p = 0.0003). The mean differences (95% limits of agreement) between the two techniques were 0.6 mm s-1 (-15.9 to 17.0) closing speed, 1.5 mm s-1 (-6.8 to 9.8) opening speed, 2.4 ms (-6.8 to 11.5) closed phase duration and 5.0 ms (-19.4 to 29.3) total blink duration. COR values were 10.1 mm s-1 closing speed, 3.7 mm s-1 opening speed, 6.7 ms closed phase duration and 11.2 ms total blink duration. CONCLUSIONS: This study has shown that spontaneous blinking can be characterised using a non-invasive imaging system. The semi-automated analysis provides a rapid characterisation of blink dynamics, allowing its application in large-scale trials in a number of clinical areas.


Assuntos
Piscadela/fisiologia , Diagnóstico por Imagem/métodos , Pálpebras/fisiologia , Processamento de Imagem Assistida por Computador/instrumentação , Software , Adulto , Feminino , Humanos , Masculino , Projetos Piloto , Gravação em Vídeo
9.
Soft Matter ; 14(8): 1301-1310, 2018 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-29368788

RESUMO

The mechanical properties of an all-acrylate liquid crystal elastomer (LCE) with a glass transition of 14 ± 1 °C are reported. The highly nonlinear load curve has a characteristic shape associated with semi-soft elasticity (SSE). Conversely, measurements of the director orientation throughout tensile loading instead indicate a "mechanical-Fréedericksz" transition (MFT). Values of the step length anisotropy, r, are independently calculated from the theories of SSE (r = 3.2 ± 0.4), MFT (9.3 < r < 30.0) and thermally-induced length change (r = 3.8 ± 0.5). From simultaneously recorded polarising microscopy textures, the consequences of the above discrepancies are considered. Further, a mechanically-induced negative order parameter is observed. Results show the tensile load curve shape cannot solely be used to determine the underlying physics. Consequently, the LCE properties cannot be fully described by theories of SSE or MFTs alone. This suggests that the theory of LCEs is not yet complete. The conclusions suggest that both the LC order parameter and r must be functions of the mechanical deformation.

10.
Optom Vis Sci ; 94(9): 919-927, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28816728

RESUMO

SIGNIFICANCE: There remains only a small amount of data from human studies demonstrating the effect of contact lens/lens care solution combinations on the deposition of lipids. Therefore, information on the degree to which modern materials deposit lipids when used with contemporary care solutions would be valuable. PURPOSE: The present study aims to determine the effect of lens care system combinations on levels of total lipid, cholesterol, and cholesteryl esters extracted from three different contact lenses (CLs) when used with four contemporary care systems. METHODS: Experienced CL wearers were recruited to participate in this study. Combinations of three CLs (etafilcon A [ETA], galyfilcon A [GALY], and senofilcon A [SENO]) and four CL care solutions (Biotrue, ClearCare, OPTI-FREE PureMoist, and RevitaLens Ocutec) were investigated. A total of 791 CLs were analyzed. Subjects were randomized to one lens type and then used all four lens care solutions in random sequence for 10-14 days before the CLs were collected and analyzed for the amount of cholesterol, cholesteryl esters, and total lipids. RESULTS: The mean range of cholesterol recovered across the different care solutions was 0.34-2.77 µg/lens, 3.48-4.29 µg/lens, and 4.75-6.20 µg/lens for ETA, SENO, and GALY lenses, respectively. Use of OPTI-FREE PureMoist with ETA lenses led to a significantly greater amount of cholesterol being recovered when compared to the use of the other solutions with ETA lenses (P < .05). The mean range of cholesteryl esters recovered across different care solutions was 1.31-2.02 µg/lens, 6.43-7.19 µg/lens, and 7.96-10.13 µg/lens for ETA, SENO, and GALY lenses, respectively. There were no differences in the amount of cholesteryl esters and total lipids extracted for a given lens type when used with any of the four care solutions (P > .05). CONCLUSIONS: This study did not demonstrate conclusively that any of the solution/CL combinations were superior to any of the other combinations when the amounts of lipid deposition were compared among the tested lenses.


Assuntos
Soluções para Lentes de Contato/farmacologia , Lentes de Contato , Lipídeos/análise , Erros de Refração/terapia , Adolescente , Adulto , Idoso , Contaminação de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
11.
Optom Vis Sci ; 93(8): 809-19, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27309523

RESUMO

PURPOSE: To compare subjective comfort and ocular physiology with three multipurpose solutions (MPSs) to that of a peroxide-based system with three different soft contact lens materials. METHODS: Habitual soft contact lens wearers (n = 236) were enrolled at three sites and completed a washout period with no contact lens solution for ≥4 days. Subjects were randomly assigned to one of three lens types: etafilcon A, galyfilcon A, or senofilcon A. A new lens of the assigned type was worn for 10 to 14 days each while using one of four care solutions, in random order (A-polyaminopropyl biguanide + polyquaternium, B-POLYQUAD + Aldox, C-alexidine + polyquaternium-1, and D-hydrogen peroxide) with a washout period (≥4 days) between each solution. After each care solution, biomicroscopy was performed and subjective comfort was assessed using the Contact Lens User Experience (CLUE) questionnaire and other instruments including comfortable wear time (CWT). Linear mixed models were used for analysis. Comfort and biomicroscopy signs with each MPS were compared to that of the peroxide solution. RESULTS: Subjective CLUE Comfort score across all lens types with each MPS was not significantly different than with the peroxide solution (p = 0.98). There were no differences in CWT between each MPS and the peroxide solution for any lens type (range of differences: -0.8 to 0.8 h; all p ≥ 0.13). Six MPS/material combinations had no clinically meaningful change in corneal staining versus peroxide (<0.5 units); three combinations could increase staining by up to 0.57 units. Staining was

Assuntos
Soluções para Lentes de Contato , Lentes de Contato Hidrofílicas , Fenômenos Fisiológicos Oculares , Conforto do Paciente , Adolescente , Adulto , Idoso , Biguanidas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Propilaminas , Coloração e Rotulagem , Inquéritos e Questionários
12.
Optom Vis Sci ; 93(8): 963-72, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27391539

RESUMO

PURPOSE: To evaluate the effect of four contemporary lens care solutions on total protein, total lysozyme, and active lysozyme extracted from three contact lens materials. METHODS: Adapted contact lens wearers were recruited at three sites, and all subjects were randomly assigned to daily wear of either etafilcon A, galyfilcon A, or senofilcon A for 2 weeks. Four lens care solutions (Biotrue, OPTI-FREE PureMoist, RevitaLens OcuTec, and ClearCare) were used by each subject in random order with a new pair of lenses after a washout period between solutions of at least 4 days. After 2 weeks of daily wear, contact lenses were collected for analysis. Proteins were extracted from a subset of contact lenses (n = 568) and total protein, total lysozyme, and lysozyme activity were quantified using a modified Bradford assay, an enzyme-linked immunosorbent assay, and a micrococcal assay, respectively. RESULTS: Higher levels of total protein were extracted from etafilcon A when used with Biotrue compared to other solutions (p = 0.0001). There were higher levels of total lysozyme extracted from galyfilcon A lenses when used with PureMoist than with Biotrue or ClearCare (p < 0.006). Higher total lysozyme was extracted from senofilcon A when used with RevitaLens OcuTec compared to Biotrue (p = 0.002). Lower lysozyme activity was recovered from senofilcon A lenses with RevitaLens OcuTec when compared to all other care solutions (all p < 0.004). When Biotrue, PureMoist, or RevitaLens OcuTec were used, higher total lysozyme was extracted from galyfilcon A compared to senofilcon A (p < 0.01). When RevitaLens OcuTec was used, higher levels of active lysozyme were extracted from galyfilcon A compared to senofilcon A (p = 0.02). CONCLUSIONS: The ability of lens care solutions to remove protein from lenses varies depending upon the care solution composition and also the polymeric make-up of the contact lens material.


Assuntos
Soluções para Lentes de Contato/farmacologia , Lentes de Contato Hidrofílicas , Proteínas/análise , Adolescente , Adulto , Idoso , Ensaio de Imunoadsorção Enzimática , Contaminação de Equipamentos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
13.
Optom Vis Sci ; 93(8): 901-8, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27273272

RESUMO

PURPOSE: To describe the lid margin characteristics of contact lens wearers and relate them to comfort during lens wear. METHODS: Three study sites enrolled habitual contact lens wearers. Subjects completed the Comfort domain of the Contact Lens User Experience (CLUE) questionnaire, and each eye was graded for the presence of mucocutaneous junction (MCJ) displacement, lid margin irregularity, and lid margin vascularity. Examiners counted the number of meibomian gland (MG) orifices in the central centimeter of the lower eyelid and the number of those that showed pouting/plugging and vascular invasion. MG expressibility was graded according to the Shimazaki schema. Subjects were grouped based on presence/absence of each characteristic, total number of orifices (≥5 vs. <5), and expressibility (grade 0 vs. >0). Descriptive statistics are reported. A linear model was used to assess the fixed effect of each characteristic on combined CLUE score and each CLUE statement, if the effect on combined CLUE score showed p < 0.10. RESULTS: The study included 203 subjects (67.5% female) with mean age (±SD) of 30.3 ± 9.6 years. The most commonly observed characteristics were orifice pouting/plugging, compromised MG expressibility, and lid margin vascularity (35.0, 30.3, and 20.4%, respectively). MCJ displacement and MG expressibility had an effect on the combined CLUE score such that individual CLUE statements were analyzed (p = 0.01 and p = 0.06, respectively). MCJ displacement had an effect on comfort upon insertion (p = 0.01), comfort after 5 minutes (p = 0.03), end-of-day comfort (p = 0.01), and ability to maintain ocular moisture (p = 0.030). MG expressibility had a significant effect on general comfort (p = 0.01), comfort throughout the day (p = 0.02), and the ability to maintain ocular moisture (p = 0.02). CONCLUSIONS: MCJ displacement and MG expressibility have an effect on contact lens comfort.


Assuntos
Lentes de Contato , Pálpebras/diagnóstico por imagem , Glândulas Tarsais/diagnóstico por imagem , Satisfação do Paciente , Erros de Refração/terapia , Inquéritos e Questionários , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
14.
Eye Contact Lens ; 42(5): 289-94, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26709982

RESUMO

OBJECTIVES: To measure various dimensions of the upper tarsal plate and the area of upper lid wiper staining. The repeatability of the method of measurement was investigated. METHODS: Thirty-five healthy non-contact lens wearers were enrolled. The following parameters were measured from digital images of the upper eyelid captured with a slitlamp camera: length, height, and total area of the tarsal plate and area of lid wiper staining (lissamine green). Measurements were performed in a randomized and masked fashion on two separate occasions by the same investigator using ImageJ (National Institutes of Health). Coefficients of repeatability (COR) were calculated. RESULTS: The dimensions (mean±SD) of the tarsal plate were 20.6±1.9 mm length, 7.9±0.8 mm height, and 103.3±18.8 mm total area. The area of lid wiper staining was 2.7±2.0 mm. No association was found between tarsal dimensions and lid wiper staining (all P>0.05). Image analysis COR values were 0.6 mm tarsal length, 0.1 mm tarsal height, 1.2 mm tarsal area, and 0.4 mm lid wiper staining. There was no significant difference between repeated measurements for any parameter (all P>0.05). Limits of agreement were narrow for all parameters, indicating good agreement between repeated measurements. CONCLUSIONS: This work has demonstrated that there is a wide range in the dimensions of the upper tarsal plate in an urban UK population. No association was found between the upper tarsal dimensions and lid wiper staining. ImageJ was shown to be a repeatable method to measure the dimensions of the upper tarsal plate and upper lid wiper staining.


Assuntos
Túnica Conjuntiva/anatomia & histologia , Pálpebras/anatomia & histologia , Adulto , Feminino , Humanos , Corantes Verde de Lissamina/administração & dosagem , Masculino , Fotografação/métodos , Reprodutibilidade dos Testes , Reino Unido , População Urbana , Adulto Jovem
15.
Opt Express ; 23(8): 9911-6, 2015 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-25969032

RESUMO

Liquid crystal (LC) contact lenses are emerging as an exciting technology for vision correction. A homeotropically (vertical) aligned LC lens is reported that offers improved optical quality and simplified construction techniques over previously reported LC contact lens designs. The lens has no polarization dependence in the off state and produces a continuous change in optical power of up to 2.00 ± 0.25 D with a voltage applied. The variation in optical power results from the voltage-induced change in refractive index of the nematic LC layer, from 1.52 to a maximum of 1.72. One device substrate is treated with an alignment layer that is a mixture of planar and homeotropic polyimides, rubbed to induce a preferred director orientation in the switched state. Defects that could occur during switching are thus avoided and the lens exhibits excellent optical quality with a continuous variation in focal power.

16.
Optom Vis Sci ; 92(7): 758-67, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26101823

RESUMO

PURPOSE: To document contact lens prescribing patterns in the United States between 2002 and 2014. METHODS: A survey of contact lens prescribing trends was conducted each year between 2002 and 2014, inclusive. Randomly selected contact lens practitioners were asked to provide information relating to 10 consecutive contact lens fits between January and March each year. RESULTS: Over the 13-year survey period, 1650 survey forms were received from US practitioners representing details of 7702 contact lens fits. The mean (±SD) age of lens wearers was 33.6 (±15.2) years, of whom 65.2% were female. Rigid lens new fits decreased from 13.0% in 2002 to 9.4% in 2014. Across this period, silicone hydrogels have replaced mid water contact lens hydrogels as the soft lens material of choice. Toric lenses represented about 25 to 30% of all soft lens fits. Multifocal soft lenses are generally preferred to monovision. Daily disposable lens fits have recently increased, and in 2014, they represented 27.1% of all soft lens fits. Most lenses are prescribed on 1 to 2 weekly or monthly lens replacement regimen. Extended wear remains a minority lens wearing modality. The vast majority of those wearing reusable lenses use multipurpose lens care solutions. Lenses are mostly worn 7 d/wk. CONCLUSIONS: This survey has revealed prescribing trends and preferences in the United States over the past 13 years.


Assuntos
Lentes de Contato Hidrofílicas/tendências , Padrões de Prática Médica/tendências , Prescrições/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Equipamentos Descartáveis/estatística & dados numéricos , Feminino , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Optometria/estatística & dados numéricos , Ajuste de Prótese , Inquéritos e Questionários , Estados Unidos
17.
Optom Vis Sci ; 92(1): 44-52, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25562479

RESUMO

PURPOSE: To compare clinical and subjective quality-of-life (QoL) data for teenagers wearing daily disposable contact lenses or spectacles. METHODS: This open-label study randomized subjects (aged 13 to 19 years) with no previous contact lens wear experience to nelfilcon A (DAILIES AquaComfort Plus) contact lenses or spectacles for 6 months. A full clinical workup, as well as subjective QoL measures using the Pediatric Refractive Error Profile and Quality of Life Impact of Refractive Correction questionnaires, was conducted at baseline and at week 4 and months 3 and 6, with an additional study visit at week 2 for subjects randomized to wear contact lenses. RESULTS: A total of 110 teenagers were enrolled in the study; 13 discontinued before study completion, 10 (17.5%) from the contact lens group and 3 (5.7%) from the spectacle group (p = 0.04). Visual acuity was good for both groups at all study visits. Biomicroscopy assessments were similar at baseline for both groups. Significant differences in Pediatric Refractive Error Profile responses were noted between vision correction groups across visits for appearance (p < 0.001), satisfaction (p < 0.001), activities (p < 0.001), peer perception (p = 0.003), and overall score (p < 0.001). For Quality of Life Impact of Refractive Correction, the contact lens group gave more favorable responses than the spectacle group (p = 0.02). After 6 months of wearing contact lenses, teenagers had a more positive attitude toward comfort, vision, and safety with contact lenses. No serious adverse events were reported during the study. CONCLUSIONS: The daily disposable lenses used in this study are suitable for vision correction for teenagers, offering improvements in QoL measures during the first month of wear, including appearance, satisfaction, activities, and peer perceptions, without negatively impacting vision or eye health. Teenagers were able to handle contact lenses with the same amount of confidence as spectacles.


Assuntos
Lentes de Contato Hidrofílicas , Óculos , Miopia/psicologia , Miopia/terapia , Qualidade de Vida/psicologia , Adolescente , Comportamento do Adolescente/psicologia , Equipamentos Descartáveis , Feminino , Humanos , Masculino , Miopia/fisiopatologia , Satisfação do Paciente , Ajuste de Prótese , Autoimagem , Inquéritos e Questionários , Acuidade Visual/fisiologia , Adulto Jovem
18.
Opt Express ; 22(7): 8035-40, 2014 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-24718178

RESUMO

Presbyopia, the age-related reduction in near vision acuity, is one of the leading issues facing the contact lens industry due to an increasingly ageing population and limitations associated with existing designs. A plastic-based liquid crystal contact lens is described which is designed to allow switchable vision correction. The device is characterized by low operating voltages (<5V(rms)) and has curvatures suitable for placement upon the cornea. Imaging and Point Spread Function analysis confirm that the lens provides an increase in optical power of + 2.00 ± 0.25 D when activated, ideal for presbyopia correction.


Assuntos
Envelhecimento , Lentes de Contato Hidrofílicas , Sensibilidades de Contraste/fisiologia , Eletrônica/métodos , Cristais Líquidos , Presbiopia/terapia , Idoso , Humanos , Presbiopia/fisiopatologia
19.
Transl Vis Sci Technol ; 13(8): 28, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39150716

RESUMO

Purpose: To determine the minimal clinically important difference (MCID) for contact lens (CL)-related subjective responses and explore whether MCID values differ between subjective responses and study designs. Methods: This was a retrospective analysis of data from seven one-week bilateral crossover studies and 14 one-day contralateral CL studies. For comfort, dryness, vision, or ease of insertion, participants rated on a 0-100 visual analogue scale (VAS) and indicated lens preference on a five-point Likert scale featuring strong, slight, and no preferences. For each criterion, four MCID estimates were calculated and averaged: mean VAS score difference for "slight preference," lower limit of 95% confidence interval VAS score difference for "slight preference," difference in mean VAS score difference between "slight" and "no preference" and 0.5 standard deviation of VAS scores. Results: The four calculation methods generated a small range of MCID values. For bilateral studies, the averaged MCID was 7.2 (range 5.4-8.8) for comfort, 8.1 (5.2-10.6) for dryness, 7.1 (5.5-9.3) for vision and 7.6 (6.0-10.5) for ease of insertion. For contralateral studies, the averaged MCID was 6.9 (6.1-7.6) for comfort at insertion and 7.5 (6.8-8.2) for end-of-day comfort. Conclusions: This work demonstrated very similar MCID values across subjective responses and study designs, in a population of habitual soft CL wearers. In all cases, MCID values were on average seven units on a 0 to 100 VAS. Translational Relevance: This work provides MCID values which are important for interpreting ocular subjective responses and planning clinical studies.


Assuntos
Estudos Cross-Over , Diferença Mínima Clinicamente Importante , Humanos , Estudos Retrospectivos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Escala Visual Analógica , Lentes de Contato , Satisfação do Paciente , Lentes de Contato Hidrofílicas , Idoso , Conforto do Paciente/métodos
20.
Cont Lens Anterior Eye ; : 102310, 2024 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-39277529

RESUMO

PURPOSE: Introduced around the turn of the 21st century, silicone hydrogel contact lenses alleviated hypoxic anterior eye complications due to their high oxygen transmissibility. The purpose of this work is to update earlier surveys by describing international trends in silicone hydrogel daily wear contact lens fitting between 2000 and 2023. METHOD: An annual contact lens prescribing survey was sent to eye care practitioners in up to 71 countries between 2000 and 2023. Data relating to 260,144 daily wear soft contact lens fits undertaken in 20 countries returning reliable longitudinal data were analysed in respect of silicone hydrogel daily wear contact lens fitting. RESULTS: There has been a dramatic increase in silicone hydrogel daily wear lens fits (p < 0.0001), increasing from 2.8 % of all daily wear soft lens fits in 2000 to 73.7 % in 2023. Of all daily wear soft contact lenses prescribed to males, 44.6 % were silicone hydrogel lenses, compared with 43.5 % for females (p = 0.0146). The mean age of those wearing silicone hydrogel daily wear lenses was 32.0 ± 14.5 years, compared to 30.4 ± 13.6 years for those wearing daily wear hydrogel lenses (p < 0.0001). Between 2019-2023, the average percentage of fits was - (a) material type: silicone hydrogel - 73 %; mid-water content hydrogels - 13 %; high water content hydrogels - 9 %; and low water content hydrogels - 5 %, and (b) lens design: spherical - 44 %, toric - 32 %, multifocal - 17 %, monovision - 4 %, and 'other' - 3 %. CONCLUSION: The dramatic increase in silicone hydrogel contact lens prescribing for daily wear has been commensurate with the introduction of multiple lens brands and an ongoing expansion of lens designs, parameters and replacement frequency options. The balance between silicone hydrogel and hydrogel lens prescribing is perhaps starting to approach an equilibrium.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA