Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Hepatology ; 74(2): 907-925, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33908067

RESUMO

BACKGROUND & AIMS: Acute-on-chronic liver failure (ACLF) is characterized by systemic inflammation, monocyte dysfunction, and susceptibility to infection. Lysophosphatidylcholines (LPCs) are immune-active lipids whose metabolic regulation and effect on monocyte function in ACLF is open for study. APPROACHES & RESULTS: Three hundred forty-two subjects were recruited and characterized for blood lipid, cytokines, phospholipase (PLA), and autotaxin (ATX) concentration. Peripheral blood mononuclear cells and CD14+ monocytes were cultured with LPC, or its autotaxin (ATX)-derived product, lysophosphatidic acid (LPA), with or without lipopolysaccharide stimulation and assessed for surface marker phenotype, cytokines production, ATX and LPA-receptor expression, and phagocytosis. Hepatic ATX expression was determined by immunohistochemistry. Healthy volunteers and patients with sepsis or acute liver failure served as controls. ACLF serum was depleted in LPCs with up-regulated LPA levels. Patients who died had lower LPC levels than survivors (area under the receiver operating characteristic curve, 0.94; P < 0.001). Patients with high-grade ACLF had the lowest LPC concentrations and these rose over the first 3 days of admission. ATX concentrations were higher in patients with AD and ACLF and correlated with Model for End-Stage Liver Disease, Consortium on Chronic Liver Failure-Sequential Organ Failure Assessment, and LPC/LPA concentrations. Reduction in LPC correlated with higher monocyte Mer-tyrosine-kinase (MerTK) and CD163 expression. Plasma ATX concentrations rose dynamically during ACLF evolution, correlating with IL-6 and TNF-α, and were associated with increased hepatocyte ATX expression. ACLF patients had lower human leukocyte antigen-DR isotype and higher CD163/MerTK monocyte expression than controls; both CD163/MerTK expression levels were reduced in ACLF ex vivo following LPA, but not LPC, treatment. LPA induced up-regulation of proinflammatory cytokines by CD14+ cells without increasing phagocytic capacity. CONCLUSIONS: ATX up-regulation in ACLF promotes LPA production from LPC. LPA suppresses MerTK/CD163 expression and increases monocyte proinflammatory cytokine production. This metabolic pathway could be investigated to therapeutically reprogram monocytes in ACLF.


Assuntos
Insuficiência Hepática Crônica Agudizada/mortalidade , Monócitos/imunologia , Insuficiência Hepática Crônica Agudizada/diagnóstico , Insuficiência Hepática Crônica Agudizada/imunologia , Insuficiência Hepática Crônica Agudizada/metabolismo , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Separação Celular , Células Cultivadas , Feminino , Citometria de Fluxo , Humanos , Inflamação/diagnóstico , Inflamação/imunologia , Inflamação/metabolismo , Lisofosfatidilcolinas/metabolismo , Lisofosfolipídeos/metabolismo , Masculino , Metabolômica , Pessoa de Meia-Idade , Monócitos/metabolismo , Diester Fosfórico Hidrolases/metabolismo , Cultura Primária de Células , Estudos Prospectivos , Índice de Gravidade de Doença , Transdução de Sinais/imunologia , Adulto Jovem
2.
Lancet ; 401(10381): 996, 2023 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-36965969
3.
Ther Drug Monit ; 38(1): 50-8, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26766748

RESUMO

BACKGROUND: A liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for routine measurement of ribavirin concentrations in EDTA-anticoagulated plasma. METHODS: After protein precipitation, we used a bridged ethylene hybrid (hydrophilic interaction) chromatography column, 0.1 mmol/L ammonium formate pH 3.0, and a gradient of 85%-96% acetonitrile to achieve baseline separation of ribavirin from isobaric uridine. Quantitation was assured using both primary (m/z 245.3 > 113.0) and secondary transitions (m/z 245.3 > 96.0) of the protonated species. Chromatographic separation and column washing also negated interference from major phospholipid species. RESULTS: There was a linear relationship between concentration and response to 10 mg/L, with a minimum detectable level and a minimum level of quantitation both of 0.1 mg/L. Imprecision within the assay was <10% at 0.1 mg/L and <6% between assays for concentrations >0.4 mg/L. Bias was <4%. In clinical samples (n = 12), there was no difference in ribavirin concentrations obtained by an established liquid chromatographic assay with ultraviolet detection. Ribavirin concentrations were stable in plasma stored at room temperature for 3 days but then decreased significantly on day 7. Plasma concentrations were stable for 15 weeks at -20 °C. Concentrations in plasma separated from whole blood at room temperature fell by a median of 19.4% at 4 hours and then rose substantially (median 251% by 3 days). Dose-normalized ribavirin concentrations reached a steady state after a mean of >6 weeks treatment in 76 patients with hepatitis C. CONCLUSIONS: A hydrophilic interaction liquid chromatography-tandem mass spectrometric method to measure ribavirin in plasma was developed. Samples for ribavirin estimation should be kept at 4 °C, separated within 2 hours of collection and stored at 4 °C before analysis, with long-term storage at -20 °C. This method was applied to a study of the ribavirin therapeutic monitoring in patients with hepatitis C.


Assuntos
Cromatografia Líquida/métodos , Monitoramento de Medicamentos/métodos , Ribavirina/sangue , Espectrometria de Massas em Tandem/métodos , Adolescente , Adulto , Idoso , Antivirais/sangue , Criança , Pré-Escolar , Estabilidade de Medicamentos , Armazenamento de Medicamentos , Ácido Edético/química , Hepatite C/tratamento farmacológico , Humanos , Pessoa de Meia-Idade , Fatores de Tempo , Adulto Jovem
4.
Ther Drug Monit ; 36(3): 358-65, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24305629

RESUMO

BACKGROUND: Whole-blood concentrations of the immunosuppressant drugs everolimus and sirolimus should be monitored. A sensitive and selective method offering the detection of both analytes in small sample volumes would optimize the throughput of samples for sirolimus or everolimus analysis. This study reports the validation of a liquid chromatography tandem mass spectrometry method, including a stable isotope internal standard, for the simultaneous measurement of everolimus and sirolimus. METHODS: Whole-blood samples (20 µL) were treated with ammonium bicarbonate (20 µL), zinc sulfate (20 µL), and internal standard solution ((13)C(2)D(4)-everolimus in acetonitrile, 100 µL). After centrifugation, 20 µL of the supernatant was injected onto a Waters Symmetry C18 high-performance liquid chromatography column. The aqueous and organic mobile phases were 2 mmole/L of ammonium acetate containing 0.1% (vol/vol) formic acid, in water and methanol, respectively. Analytes were detected using tandem mass spectrometry (Waters Acquity TQD). RESULTS: Analytes were eluted at around 2 minutes within a 6-minute analytical run time. Detector response was linear for both analytes across the ranges studied (1-49 µg/L for sirolimus, 1-41 µg/L for everolimus), and a lower limit of quantitation of 1 µg/L was reliably attained. Intraassay and interassay imprecision and inaccuracy were <15% (coefficient of variation) in all cases. Analyte recovery was in the range of 72%-117%. The analytes were stable in blood after freezing and thawing, and for at least 12 hours after preparation while waiting to be injected. Ion suppression and interference from phospholipids were not significant. CONCLUSIONS: A straightforward, robust liquid chromatography tandem mass spectrometry assay has been developed and validated for the simultaneous measurement of everolimus and sirolimus in small volumes of whole blood.


Assuntos
Monitoramento de Medicamentos/métodos , Imunossupressores/sangue , Sirolimo/análogos & derivados , Sirolimo/sangue , Calibragem , Cromatografia Líquida de Alta Pressão , Everolimo , Humanos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
5.
Ther Drug Monit ; 33(6): 735-41, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22105591

RESUMO

BACKGROUND: Itraconazole and posaconazole are used in the prevention and treatment of invasive fungal infections. However, the oral bioavailability of both compounds varies widely, and dose-serum concentration relationships are poorly defined for these analytes. The aim of this work was to develop and validate a simple assay that could be implemented in most laboratories for the purpose of therapeutic drug monitoring. METHODS: Calibrators (n = 7) and internal quality control solutions (n = 3) were prepared in pooled human serum. Sample (100 µL), internal standard solution (25 µL), Tris solution (2 mol/L; pH 10.6), and extraction solvent (methyl tert-butyl ether, 600 µL) were vortex mixed and centrifuged. The solvent layer was removed and evaporated to dryness and the residue reconstituted in water:methanol (1 + 3, 50 µL). A portion (5 µL) of the reconstituted extract was analyzed using a 3-µm Gemini C6 phenyl column with fluorescence detection (excitation 260 nm, emission 350 nm). The method was used to measure itraconazole and hydroxyitraconazole, or posaconazole, in serum samples taken 1-2 hours before the next dose, from patients forming part of a study into management and diagnostic strategies for invasive aspergillosis. RESULTS: Response was linear over the calibration ranges. Accuracy and imprecision were 92-111.4% and 3.2-13.4% (relative standard deviation), respectively. No interferences were noted. There was a good agreement with nominal values of each analyte in an external quality assessment scheme. In patients prescribed either 400 mg/d of itraconazole (n = 46) or 600-800 mg/d of posaconazole (n = 28) only 24% and 7% of samples, respectively, had serum itraconazole or posaconazole concentrations above the target threshold suggested in published guidelines. CONCLUSIONS: A simple, sensitive high-performance liquid chromatographic method has been developed for the analysis of itraconazole, hydroxyitraconazole, and posaconazole in serum/plasma. Few of the samples measured from patients participating in the clinical study attained concentrations of the drug/metabolite in serum that have been recommended for effective antifungal therapy.


Assuntos
Antifúngicos/sangue , Itraconazol/análogos & derivados , Itraconazol/sangue , Triazóis/sangue , Adulto , Idoso , Antifúngicos/administração & dosagem , Calibragem , Cromatografia Líquida de Alta Pressão , Estudos de Coortes , Relação Dose-Resposta a Droga , Monitoramento de Medicamentos/métodos , Feminino , Humanos , Aspergilose Pulmonar Invasiva/sangue , Aspergilose Pulmonar Invasiva/complicações , Aspergilose Pulmonar Invasiva/tratamento farmacológico , Itraconazol/administração & dosagem , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Neutropenia/complicações , Reprodutibilidade dos Testes , Espectrometria de Fluorescência , Triazóis/administração & dosagem , Adulto Jovem
6.
Biomed Chromatogr ; 25(1-2): 100-23, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21154889

RESUMO

Liquid chromatography, coupled with single-stage or tandem mass spectrometry, is a powerful tool increasingly used in analytical toxicology. However, the atmospheric pressure ionization processes involved are complex, and subject to interference from matrix components, for example. Further, the techniques used in sample preparation, chromatography and mass analysis are developing rapidly. An understanding of the advantages and limitations of LC-MS ensures appropriate analyses are performed, and that reliable results are generated. Consideration should be given to the influence of the sample preparation and chromatographic conditions on the ionization of the analyte at the mass spectrometer interface. This review aims to provide some practical guidance and examples to aid method development for commonly encountered analytes in analytical toxicology.


Assuntos
Cromatografia Líquida , Espectrometria de Massas , Testes de Toxicidade , Humanos
7.
Biomed Chromatogr ; 25(7): 775-8, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20812208

RESUMO

Monitoring serum/plasma concentrations of lamotrigine may be useful under certain circumstances. An HPLC column packed with strong cation-exchange (SCX)-modified microparticulate silica together with a 100% methanol eluent containing an ionic modifier permits direct injection of sample extracts. An HPLC-UV method developed using this principle for the measurement of serum/plasma lamotrigine is simple, sensitive and selective. The analysis time is less than 5 min. Intra- and inter-assay precision and accuracy meet acceptance criteria, and sample stability, and potential interferences from other compounds have been evaluated. There was good agreement with consensus mean results from external quality assessment samples (n = 32). Analysis of patient samples (n = 115) using the HPLC method and the Seradyn QMS® Lamotrigine immunoassay showed that the immunoassay over-estimated lamotrigine by 21% on average.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Imunoensaio/métodos , Triazinas/sangue , Cromatografia por Troca Iônica , Humanos , Lamotrigina , Análise dos Mínimos Quadrados , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Biomed Chromatogr ; 24(3): 318-23, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19634122

RESUMO

HPLC columns packed with 3 microm particle size HPLC Technology Techsphere SCX (propylsulfonic acid-modified) silica offer considerable advantages over 5 microm SCX packings in the analysis of basic drugs using 100% methanol eluents containing an ionic modifier such as ammonium perchlorate. The basic drugs studied included clozapine and norclozapine, olanzapine, quinine and quinidine, and amitriptyline, nortriptyline, imipramine and desipramine. The 3 microm column was not only more efficient for a given column length compared with 5 microm materials, but also elution times were less, a phenomenon observed in reversed-phase systems. The high efficiencies and excellent peak shapes obtained with the 3 microm SCX-modified packing together with the relatively low back-pressures attained show that such materials deserve serious consideration by laboratories involved in the analysis of basic drugs. Manufacturers should offer such packings as a matter of routine. Alternative ionic modifiers such as ammonium acetate are available for use with mass spectrometric detection if required.


Assuntos
Ácidos Alcanossulfônicos/química , Cromatografia Líquida de Alta Pressão/métodos , Percloratos/química , Preparações Farmacêuticas/análise , Compostos de Amônio Quaternário/química , Dióxido de Silício/química , Cátions/química , Cromatografia Líquida de Alta Pressão/instrumentação
9.
Neuropsychopharmacology ; 32(12): 2520-9, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17356567

RESUMO

The mechanisms by which antidepressants regulate the hypothalamic-pituitary-adrenal (HPA) axis are still unknown. The ABCB1-type multiple drug resistance (MDR) p-glycoprotein (PGP) regulates the HPA axis by limiting the access of glucocorticoids to the brain in mice and humans. Previous work in cell cultures has found that antidepressants enhance glucocorticoid receptor (GR) function in vitro by inhibiting MDR PGP, and therefore by increasing the intracellular concentration of glucocorticoids-but this model has never been tested directly in animals. Here, the tricyclic antidepressant, desipramine (20 mg/kg/day, i.p., for seven days), was administered to abcb1ab MDR PGP knockout mice (congenic on the FVB/N background strain) and to FVB/N controls. The hippocampal mRNA expression of GR, mineralocorticoid receptor (MR), MDR (Mdr1a) PGP, and 11beta-hydroxysteroid dehydrogenase type 1 (11beta-HSD1) were measured, together with plasma corticosterone levels. In FVB/N controls, desipramine induced a significant upregulation of GR mRNA in the CA1 region (+31%; p=0.045); in contrast, in abcb1ab (-/-) mice, desipramine induced a significant downregulation of GR mRNA in the CA1 region (-45%; p=0.004). MR mRNA expression was unaltered. Desipramine decreased corticosterone levels in both FVB/N controls and in abcb1ab (-/-) mice, but in abcb1ab (-/-) mice the effects were smaller. Specifically, in FVB/N controls (but not in abcb1ab (-/-) mice), desipramine reduced corticosterone levels not only compared with saline-treated mice but also compared with the 'physiological' levels of untreated mice (-39%; p=0.05). Finally, desipramine reduced Mdr1a mRNA expression across all hippocampus areas (-9 to -23%), but had no effect on 11beta-HSD1 mRNA expression. These data support the notion that the MDR PGP is one of the molecular targets through which antidepressants regulate the HPA axis.


Assuntos
Transportadores de Cassetes de Ligação de ATP/fisiologia , Antidepressivos Tricíclicos/farmacologia , Desipramina/farmacologia , Receptores de Glucocorticoides/metabolismo , Regulação para Cima/efeitos dos fármacos , Subfamília B de Transportador de Cassetes de Ligação de ATP , Membro 1 da Subfamília B de Cassetes de Ligação de ATP , Transportadores de Cassetes de Ligação de ATP/genética , Análise de Variância , Animais , Corticosterona/sangue , Hipocampo/efeitos dos fármacos , Hipocampo/metabolismo , Hibridização In Situ/métodos , Masculino , Camundongos , Camundongos Knockout , RNA Mensageiro/metabolismo , Receptores de Glucocorticoides/genética
10.
Clin Toxicol (Phila) ; 45(7): 791, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17952747

RESUMO

INTRODUCTION: Fluvoxamine is a selective serotonin reuptake inhibitor (SSRI) that is used in the management of depression and obsessive compulsive disorders. We report a patient with status epilepticus requiring quadruple anti-convulsant treatment following a fluvoxamine overdose. CASE REPORT: A 25-year-old female presented with drowsiness at 12 hours following deliberate ingestion of 9.6 grams of fluvoxamine. Sixteen hours after ingestion, she developed status epilepticus that required treatment with benzodiazepines (lorazepam and midazolam), thiopentone, phenytoin and phenobarbitone. Her serum fluvoxamine concentration on presentation was 1970 microg/L (therapeutic 160-220 microg/L) and routine toxicological screening was negative for other drugs. She was discharged home after 72 hours with no further episodes of seizures. DISCUSSION: Most patients with fluvoxamine poisoning are either asymptomatic or may develop mild signs of serotonergic toxicity. Although serotonin syndrome and isolated seizures are reported in fluvoxamine poisoning, we report the first patient with confirmed isolated fluvoxamine toxicity who developed status epilepticus.


Assuntos
Antidepressivos de Segunda Geração/intoxicação , Fluvoxamina/intoxicação , Intoxicação/etiologia , Estado Epiléptico/induzido quimicamente , Tentativa de Suicídio , Adulto , Antidepressivos de Segunda Geração/sangue , Barbitúricos/uso terapêutico , Benzodiazepinas/uso terapêutico , Overdose de Drogas , Quimioterapia Combinada , Feminino , Fluvoxamina/sangue , Humanos , Intoxicação/tratamento farmacológico , Intoxicação/fisiopatologia , Convulsões/induzido quimicamente , Convulsões/fisiopatologia , Estado Epiléptico/fisiopatologia , Resultado do Tratamento
11.
Forensic Sci Int ; 229(1-3): 145-50, 2013 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-23477803

RESUMO

Therapeutic drug monitoring (TDM) of atypical antipsychotics is common, but published methods often specify relatively complex sample preparation and analysis procedures. The aim of this work was to develop and validate a simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of amisulpride, aripiprazole and dehydroaripiprazole, clozapine and norclozapine, olanzapine, quetiapine, risperidone and 9-hydroxyrisperidone, and sulpiride in small (200 µL) volumes of plasma or serum for TDM purposes. The applicability of the method as developed to haemolysed whole blood and to oral fluid was also investigated. Analytes and internal standards were extracted into butyl acetate:butanol (9+1, v/v) and a portion of the extract analysed by LC-MS/MS (100 mm × 2.1 mm i.d. Waters Spherisorb S5SCX; eluent: 50 mmol/L methanolic ammonium acetate, pH* 6.0; flow-rate 0.5 mL/min; positive ion APCI-SRM, two transitions per analyte). Assay calibration (human plasma, oral fluid, and haemolysed whole blood calibration solutions) was performed by plotting the ratio of the peak area of the analyte to that of the appropriate internal standard. Assay validation was as per FDA guidelines. Assay calibration was linear across the concentration ranges studied. Inter- and intra-assay precision and accuracy were within 10% for all analytes in human plasma. Similar results were obtained for oral fluid and haemolysed whole blood, except that aripiprazole and dehydroaripiprazole were within 15% accuracy at low concentration (15 µg/L) in oral fluid, and olanzapine inter-assay precision could not be assessed in these matrices due to day-by-day degradation of this analyte. Recoveries varied between 16% (sulpiride) and 107% (clozapine), and were reproducible as well as comparable between human plasma, human serum, calf serum and haemolysed whole blood. For oral fluid, recoveries were reproducible, but differed slightly from those in plasma suggesting the need for calibration solutions to be prepared in this medium if oral fluid is to be analysed. LLOQs were 1-5 µg/L depending on the analyte. Neither ion suppression/enhancement, nor interference from some known metabolites of the antipsychotics studied has been encountered. The method has also been applied to the analysis of blood samples collected post-mortem after dilution (1+1, 1+3; v/v) in analyte-free calf serum.


Assuntos
Antipsicóticos/análise , Hemólise , Saliva/química , Amissulprida , Aripiprazol , Benzodiazepinas/análise , Cromatografia Líquida , Clozapina/análogos & derivados , Clozapina/análise , Dibenzotiazepinas/análise , Feminino , Toxicologia Forense/métodos , Humanos , Isoxazóis/análise , Masculino , Olanzapina , Palmitato de Paliperidona , Piperazinas/análise , Pirimidinas/análise , Fumarato de Quetiapina , Quinolonas/análise , Reprodutibilidade dos Testes , Risperidona/análise , Soro/química , Sulpirida/análogos & derivados , Sulpirida/análise , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA