Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J UOEH ; 44(1): 1-13, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35249934

RESUMO

We manufactured a wearable particle monitor (WPM), which is a simple and low-cost dust monitor. We aimed to evaluate the usefulness of the device by using it and location information of a Global Navigation Satellite System (GNSS) to measure dust generation in outdoor workplaces. We used nine WPMs and a particle counter KC-52 to measure in parallel the dust concentration diffusing standard particles in a dust exposure apparatus to evaluate the measurability of the WPM, and visualized dust generation in outdoor workplaces to evaluate its usability. We obtained location information using a GNSS in parallel with measuring with the WPM. The measured values of the WPM followed the measured values of the KC-52, with a strong correlation of the values between the KC-52 and each WPM. The discrepancy among devices tended to increase, however, because the measured values of the WPMs increased. For outdoor measurements, we could create a heat map of the relative values of dust generation by combining two data of the WPM and the GNSS. The methods of using the WPM could overview the conditions needed to produce dust emissions in dust-generating workplaces.


Assuntos
Poeira , Dispositivos Eletrônicos Vestíveis , Poeira/análise , Monitoramento Ambiental , Tamanho da Partícula , Local de Trabalho
2.
Int J Cancer ; 146(11): 3098-3113, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31495919

RESUMO

Ionizing radiation (IR) and cisplatin are frequently used cancer treatments, although the mechanisms of error-prone DNA repair-mediated genomic instability after anticancer treatment are not fully clarified yet. RECQL4 mutations mainly in the C-terminal region of the RECQL4 gene lead to the cancer-predisposing Rothmund-Thomson syndrome, but the function of RECQL4ΔC (C-terminus deleted) in error-prone DNA repair remains unclear. We established several RECQL4ΔC cell lines and found that RECQL4ΔC cancer cells, but not RECQL4ΔC nontumorigenic cells, exhibited IR/cisplatin hypersensitivity. Notably, RECQL4ΔC cancer cells presented increased RPA2/RAD52 foci after cancer treatments. RECQL4ΔC HCT116 cells exhibited increased error-prone single-strand annealing (SSA) activity and decreased alternative end-joining activities, suggesting that RECQL4 regulates the DNA repair pathway choice at double-strand breaks. RAD52 depletion by siRNA or RAD52 inhibitors (5-aminoimidazole-4-carboxamide-1-ß-D-ribofuranoside [AICAR], (-)-epigallocatechin [EGC]) or a RAD52-phenylalanine 79 aptamer significantly restrained the growth of RAD52-upregulated RECQL4ΔC HCT116 cells in vitro and in mouse xenografts. Remarkably, compared to single-agent cisplatin or EGC treatment, cisplatin followed by low-concentration EGC had a significant suppressive effect on RECQL4ΔC HCT116 cell growth in vivo. Together, the regimens targeting the RAD52-mediated SSA pathway after anticancer treatment may be applicable for cancer patients with RECQL4 gene mutations.


Assuntos
Cisplatino/farmacologia , Reparo do DNA/genética , Proteína Rad52 de Recombinação e Reparo de DNA/metabolismo , Radiação Ionizante , RecQ Helicases/genética , Animais , Catequina/análogos & derivados , Catequina/farmacologia , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Reagentes de Ligações Cruzadas/farmacologia , Quebras de DNA de Cadeia Dupla , Células HCT116 , Humanos , Células MCF-7 , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Transplante de Neoplasias , Neoplasias/genética , Neoplasias/patologia , Neoplasias/terapia , Proteína Rad52 de Recombinação e Reparo de DNA/antagonistas & inibidores , Proteína Rad52 de Recombinação e Reparo de DNA/genética , Proteína de Replicação A/genética , Transplante Heterólogo
3.
Int J Mol Sci ; 21(3)2020 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-32012663

RESUMO

Biodosimetry is a useful method for estimating personal exposure doses to ionizing radiation. Studies have identified metabolites in non-cellular biofluids that can be used as markers in biodosimetry. Levels of metabolites in blood cells may reflect health status or environmental stresses differentially. Here, we report changes in the levels of murine blood cell metabolites following exposure to X-rays in vivo. Levels of blood cell metabolites were measured by capillary electrophoresis time-of-flight mass spectrometry. The levels of 100 metabolites were altered substantially following exposure. We identified 2-aminobutyric acid, 2'-deoxycytidine, and choline as potentially useful markers of radiation exposure and established a potential prediction panel of the exposure dose using stepwise regression. Levels of blood cell metabolites may be useful biomarkers in estimating exposure doses during unexpected radiation incidents.


Assuntos
Biomarcadores , Células Sanguíneas/metabolismo , Células Sanguíneas/efeitos da radiação , Eletroforese Capilar , Radiação Ionizante , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Relação Dose-Resposta à Radiação , Metaboloma , Metabolômica/métodos
4.
Artigo em Japonês | MEDLINE | ID: mdl-32074530

RESUMO

Japanese Diagnostic Reference Levels (DRLs) were released as "Japan DRLs 2015" from Japan Network for Research and Information on Medical Exposure (J-RIME) in June 2015. In "Japan DRLs 2015", DRLs in angiography and interventional procedures are set at a fluoroscopic dose rate of 20 mGy/min at the interventional reference point using a phantom. In order to achieve optimization with DRLs, then it need to be revised regularly. Therefore, we (research group to examine the effect of Japan DRLs 2015 and the necessity of additional items in angiography and vascular interventions) examined the effects of "Japan DRLs 2015" on angiography and interventional procedures. And we also investigated for DRLs revision in the future. As a result, it turned out that it is important to create DRLs in medical procedures that can be effectively used in clinical settings.


Assuntos
Angiografia , Imagens de Fantasmas , Humanos , Japão , Doses de Radiação , Valores de Referência
5.
Artigo em Japonês | MEDLINE | ID: mdl-30890674

RESUMO

To optimize the radiation protection of patients, we investigated the possibility of constructing the diagnostic reference levels (DRLs) by imaging objective/disease group using display value of the blood vessel imaging apparatus (air kerma-area product: PKA, air kerma at the patient entrance reference point: Ka, r) in cerebral angiography. We used PKA and Ka, r recorded during surgery of 997 patients at our hospital, and classified them according to the purpose of imaging (diagnostic cerebral angiography or neuro interventional radiology) and disease group. Neuro interventional radiology (PKA: 268±155 Gy・cm2, Ka, r: 2420±1462 mGy) was significantly higher than that of diagnostic cerebral angiography (PKA: 161±70 Gy・cm2, Ka, r: 1112±485 mGy), (Mann-Whitney test, P<0.01). Significant difference was found between PKA and Ka, r for imaging purpose and disease group (Kruskal-Wallis test, P<0.05). It is highly probable that the DRL for cerebral angiography can be constructed by imaging purpose/disease group using display value (PKA, Ka, r) of the blood vessel imaging apparatus.


Assuntos
Angiografia Cerebral , Proteção Radiológica , Fluoroscopia , Humanos , Doses de Radiação , Estudos Retrospectivos
6.
J UOEH ; 38(4): 335-343, 2016.
Artigo em Japonês | MEDLINE | ID: mdl-27980317

RESUMO

The recent progress in angiography technology bestows benefits on patients for minimally invasive than surgery, while there has been an increase in the number of cases involving stochastic effects, such as radiation dermatitis, resulting from upgrading of the procedure because of an extension of the time for fluoroscopy and the number of shots. Recent CT equipment saves the dose data along with image data about the information management for patient exposure dose, which is used for management of individual cumulative dose and the presumed effective dose, using digital imaging and communication in medicine (DICOM). We extracted detailed information about shooting conditions and dose from the DICOM radiation dose structured report (DICOM RDSR) in the angiography area, and evaluated the trend of patient exposure dose in each procedure. As a result, we found that cases exceeding 3 Gy which needed observation in the head region were 16.7% and in the heart region were 27.3%. We also found that angiography had a higher dose of shooting than did fluoroscopy, and that the diagnosis and treatment with tumor involvement required a exposure dose than did vascular lesion. In this paper, we review the shooting conditions as a root of DICOM RDSR information and consider the possibility of planning for further reduction of the exposure dose.


Assuntos
Angiografia/métodos , Transtornos Cerebrovasculares/diagnóstico por imagem , Cardiopatias/diagnóstico por imagem , Pescoço/irrigação sanguínea , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem , Doses de Radiação , Software
7.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 72(1): 73-81, 2016 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-26796936

RESUMO

Deterministic effects have been reported in cardiac interventional procedures. To prevent radiation skin injuries in percutaneous coronary intervention (PCI), it is necessary to measure accurate patient entrance skin dose (ESD) and maximum skin absorbed dose (MSD). We measured the MSD on 62 patients in four facilities by using the Chest-RADIREC(Ⓡ) system. The correlation between MSD and fluoroscopic time, dose area product (DAP), and cumulative air kerma (AK) showed good results, with the correlation between MSD and AK being the strongest. The regression lines using MSD as an outcome value (y) and AK as predictor variables (x) was y=1.18x (R(2)=0.787). From the linear regression equation, MSD is estimated to be about 1.18 times that of AK in real time. The Japan diagnostic reference levels (DRLs) 2015 for IVR was established by the use of dose rates using acrylic plates (20- cm thick) at the interventional reference point. Preliminary reference levels proposed by International Atomic Energy Agency (IAEA) were provided using DAP. In this study, AK showed good correlation most of all. Hence we think that Japanese DRLs for IVR should reconsider by clinical patients' exposure dose such as AK.


Assuntos
Intervenção Coronária Percutânea , Doses de Radiação , Radiometria/métodos , Pele/efeitos da radiação , Humanos
8.
J Radiol Prot ; 35(1): N1-17, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25580668

RESUMO

The disaster at the Fukushima Daiichi Nuclear Power Plant (FDNPP) remains unresolved because the estimated time to decommission a nuclear reactor appears to be approximately 40 years. The number of workers exposed to radiation doses ranging from 1 to 100 mSv continues to increase. To understand the accident progression at Fukushima and to anticipate what we should do in the future for occupational and environmental health, we performed a survey of citizens and doctors who lived inside and outside Fukushima in 2011 and 2013. In a comparison of these 2 years, the citizens inside Fukushima continue to suffer anxiety, although those living outside Fukushima tended to feel less anxious. Medical students who had recently studied radiation biology showed much less ongoing anxiety compared with other groups, suggesting that learning about the effects of radiation is essential to understanding one's own circumstances objectively and correctly. The lack of trust in the government and in the Tokyo Electric Power Company (TEPCO) in 2013 remains high in all groups. Therefore, long-term forthright explanations from the government, TEPCO, and radiation experts are indispensable not only to establish trust with people but also to alleviate psychological stress.


Assuntos
Ansiedade/epidemiologia , Ansiedade/psicologia , Acidente Nuclear de Fukushima , Médicos/estatística & dados numéricos , Opinião Pública , Liberação Nociva de Radioativos/psicologia , Adulto , Atitude Frente a Saúde , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Liberação Nociva de Radioativos/estatística & dados numéricos , Autorrelato , Inquéritos e Questionários
9.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 71(12): 1241-7, 2015 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-26685837

RESUMO

Although measurement and management of angiographic entrance skin dose (ESD) are deemed extremely important, accurate determination of maximum ESD and its location is generally difficult because of the dependence on therapeutic technique and position. Following our development of body-mounted gear bearing radiophotoluminescence glass dosimeter (RPLD) arrays for direct measurement of ESD in cranial and cardiovascular angiography and interventional radiology (IVR), our focus next turned to the limited number of facilities equipped to read RPLD outputs and the need for methods to effectively provide feedback to clinical facilities. As described here, we first constructed an RPLD reading facility capable of sending and receiving RPLDs by post, offering the potential to enable utilization of the developed gear at all hospitals in Japan that perform angiography and IVR. We next developed specialized web-based system to generate dose maps from RPLD dose data, thereby enabling any facility to perform trial system analysis, evaluation, and implementation; and investigated the results and related problems.


Assuntos
Doses de Radiação , Radiografia Intervencionista , Angiografia , Retroalimentação , Humanos , Japão , Serviço Hospitalar de Radiologia , Radiometria , Pesquisa
10.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 71(9): 746-57, 2015 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-26400558

RESUMO

Using radio-photoluminescence glass dosimeter, we measured the entrance skin dose (ESD) in 46 cases and analyzed the correlations between maximum ESD and angiographic parameters [total fluoroscopic time (TFT); number of digital subtraction angiography (DSA) frames, air kerma at the interventional reference point (AK), and dose-area product (DAP)] to estimate the maximum ESD in real time. Mean (± standard deviation) maximum ESD, dose of the right lens, and dose of the left lens were 431.2 ± 135.8 mGy, 33.6 ± 15.5 mGy, and 58.5 ± 35.0 mGy, respectively. Correlation coefficients (r) between maximum ESD and TFT, number of DSA frames, AK, and DAP were r=0.379 (P<0.01), r=0.702 (P<0.001), r=0.825 (P<0.001), and r=0.709 (P<0.001), respectively. AK was identified as the most useful parameter for real-time prediction of maximum ESD. This study should contribute to the development of new diagnostic reference levels in our country.


Assuntos
Angiografia Cerebral , Doses de Radiação , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Pele/efeitos da radiação , Dosimetria Termoluminescente
11.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(8): 814-20, 2014 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-25142393

RESUMO

In recent years, dose justification and optimization have been attempted in percutaneous coronary intervention (PCI); however, deterministic effects have been reported. To prevent radiation skin injuries in PCI, it is necessary to measure the patient entrance skin dose (ESD), but an accurate dose measurement method has not yet been established. In this study, we developed a dosimetry gown that can measure the ESD during PCI using multiple radiophotoluminescence dosimeters (RPLDs). The RPLDs were placed into 84 pockets that were sewn into a dosimetry gown. Patients wear the original dosimetry gown during the procedures, after which we obtain accurate ESD measurements. We believe that this method using RPLDs and a newly-designed dosimetry gown provides accurate ESD measurements during PCI. We expect this system to become a standard method for measuring ESD during PCI.


Assuntos
Intervenção Coronária Percutânea , Doses de Radiação , Radiometria/instrumentação , Desenho de Equipamento , Vidro , Humanos , Medições Luminescentes/instrumentação , Imagens de Fantasmas , Lesões por Radiação/prevenção & controle , Radiometria/métodos , Pele
12.
Nurs Rep ; 14(1): 413-427, 2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38391077

RESUMO

With the International Commission on Radiological Protection's (ICRP) reduction in the radiation dose threshold for cataracts, evaluating and preventing radiation exposure to the lens of the eye among interventional radiology (IR) staff have become urgent tasks. In this study, we focused on differences in lens-equivalent dose (HT Lens) to which IR nurses in three hospitals were exposed and aimed to identify factors underlying these differences. According to analyses of time-, distance-, and shielding-related factors, the magnitude of the HT Lens dose to which IR nurses were exposed could be explained not by time or shielding but by the distance between the X-ray exposure field and the location of the IR nurse. This distance tended to be shorter in hospitals with fewer staff. The most effective means of reducing the exposure of the lenses of IR nurses' eyes to radiation is to position them at least two meters from the radiation source during angiography procedures. However, some hospitals must provide IR departments with comparatively few staff. In work environments where it is infeasible to reduce exposure by increasing distance, interventions to reduce time by managing working practices and investment in shielding equipment are also important. This study was not registered.

13.
Acta Oncol ; 52(3): 538-44, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22950386

RESUMO

BACKGROUND: Radiation-induced rib fracture has been reported as a late complication after external radiotherapy to the chest. The purpose of this study was to clarify the characteristics and risk factors of rib fracture after hypofractionated proton beam therapy (PBT). MATERIAL AND METHODS: The retrospective study comprised 67 patients with hepatocellular carcinoma who were treated using PBT of 66 Cobalt-Gray-equivalents [Gy (RBE)] in 10 fractions. We analyzed the patients' characteristics and determined dose-volume histograms (DVHs) for the irradiated ribs, and then estimated relationships between risk of fracture and several dose-volume parameters. An irradiated rib was defined to be any rib included in the area irradiated by PBT as determined by treatment-planning computed tomography. RESULTS: Among the 67 patients, a total of 310 ribs were identified as irradiated ribs. Twenty-seven (8.7%) of the irradiated ribs developed fractures in 11 patients (16.4%). No significant relationships were seen between incidence of fracture and characteristics of patients, including sex, age, tumor size, tumor site, and follow-up period (p ≥ 0.05). The results of receiver operating characteristic curve analysis using DVH parameters demonstrated that the largest area under the curve (AUC) was observed for the volume of rib receiving a biologically effective dose of more than 60 Gy(3 )(RBE) (V60) [The equivalent dose in 2 Gy fractions (EQD2); 36 Gy(3)] and the AUCs of V30 to V120 (EQD2; 18-72 Gy(3)) and Dmax to D(10 cm)(3) were similar to that of V60. No significant relationships were seen for DVH parameters and intervals from PBT to incidence of fracture. CONCLUSION: DVH parameters are useful in predicting late adverse events of rib irradiation. This study identified that V60 was a most statistically significant parameter, and V30 to V120 and Dmax to D(10 cm)(3) were also significant and clinically useful for estimating the risk of rib fracture after hypofractionated PBT.


Assuntos
Carcinoma Hepatocelular/radioterapia , Fracionamento da Dose de Radiação , Neoplasias Hepáticas/radioterapia , Terapia com Prótons/efeitos adversos , Lesões por Radiação/etiologia , Fraturas das Costelas/etiologia , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/patologia , Relação Dose-Resposta à Radiação , Feminino , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Terapia com Prótons/métodos , Lesões por Radiação/epidemiologia , Estudos Retrospectivos , Fraturas das Costelas/epidemiologia , Fatores de Risco , Carga Tumoral/efeitos da radiação
14.
Radiat Prot Dosimetry ; 199(15-16): 1774-1778, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819354

RESUMO

Chronic radiation exposure increases the risk of skin damage of medical personnel engaged in radiology. However, hand dose measurements in computed tomography (CT) for diagnostic purposes have not been evaluated. The occupational radiation dose to the hands of CT assistants was herein investigated to evaluate its compliance with the equivalent dose limit for the hand (500 mSv/year). The occupational doses of nine CT assistants were measured in 89 cases (April 2017-May 2018) by installing radio-photoluminescence glass dosemeters (GD-302 M) (70-µm dose-equivalent conversion coefficient = 0.37) on the dorsal aspect of both hands. The occupational dose to the hand was the highest with head holding (right: 1.14 mSv/CT scan, left: 1.07 mSv/CT scan). Considering the results for annual work, even for head holding, the hand dose of the CT-assisting personnel was insignificant. However, CT assistants should be mindful of the possibility of locally higher doses to hands.


Assuntos
Exposição Ocupacional , Humanos , Doses de Radiação , Exposição Ocupacional/análise , Mãos/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Corpo Clínico
15.
J Neuroendovasc Ther ; 16(10): 491-497, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37502201

RESUMO

Objective: In interventional neuroradiology (INR), the evaluation of the peak skin dose (PSD) and lens dose is important because the patient radiation dose increases in cases in which the procedure is more difficult and complex. This study evaluated the radiation doses during INR procedures using a direct measurement system. Methods: Radiation dose measurements during INR were performed in 332 patients with unruptured aneurysm (URAN), dural arteriovenous fistula (DAVF), and arteriovenous malformation (AVM). The PSD and bilateral lens doses were analyzed for each disease. The Pearson correlation test was used to determine whether the PSD and lens doses were linearly related to the reference air kerma (Ka,r). Results: In all cases, the PSD and right and left lens doses were 2.36 ± 1.28 Gy, 114.2 ± 54.6 mGy, and 189.8 ± 160.3 mGy, respectively. The PSD and lens doses of the DAVF and AVM cases were significantly higher than those of the URAN case. The Pearson correlation test revealed statistically significant positive correlations between Ka,r and PSD, Ka,r and right lens dose, and Ka,r and left lens dose. Conclusion: The characteristics of radiation dose in INR were clarified. Owing to the concern of increased radiation doses exceeding the threshold values in DAVF and AVM cases, protection from radiation is required. Simple regression analysis revealed the possibility of precisely predicting PSD using Ka,r.

16.
J Radiat Res ; 63(1): 30-35, 2022 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-34718686

RESUMO

Ionizing radiation exposure affects the redox state in vivo. Recently, whole-blood antioxidant capacity (WBAC) has been reported to decrease in a dose-dependent manner after acute total body irradiation (TBI). However, changes in WBAC after localized and chronic irradiations have not been reported. This study analyzed changes to WBAC in mice after either localized irradiation (irradiation of the left hind leg only) or chronic TBI using the i-STrap method. Leg-localized irradiation exerted limited effects on WBAC, while WBAC decreased in a dose rate-dependent manner after TBI. Further, the WBAC reached the minimum value in a shorter period at a smaller dose rate. Our results suggest that changes in WBAC do not directly reflect absorbed dose, but may reflect radiation-induced biological damage at the systemic level. This study will contribute to the understanding of radiation-induced injuries and diseases, and will facilitate the establishment of biomarkers for radiation exposure.


Assuntos
Doença Enxerto-Hospedeiro , Lesões por Radiação , Animais , Antioxidantes , Biomarcadores , Camundongos , Proteínas de Ligação a RNA , Irradiação Corporal Total
17.
Radiat Prot Dosimetry ; 198(17): 1303-1312, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35909091

RESUMO

We demonstrate a practical calibration method and its applicability for a commercially available radiophotoluminescence dosemeter (RPLD), i.e. the GD-352M (AGC Techno Glass, Shizuoka, Japan) to eye lens dose monitoring, by performing the calibration according to the ISO recommendations. The calibration was then verified through a series of experiments. For verification of the derived calibration factor (1.21 ± 0.04, k = 1) of the RPLD, we performed standard irradiations in the ISO narrow series X-ray reference fields and the simulation measurements in the actual radiation fields in a hospital. The TLD-based commercially available dosemeters, DOSIRIS™ was also put on the ISO cylinder phantom and the RANDO phantom together with the GD-352M in the verification experiments. The personal dose equivalents Hp(3) obtained from the GD-352M and those obtained from the DOSIRIS™ were in good agreement with each other. Our results demonstrate the proper calibration of a commercially available RPLD that is applicable to the additional monitoring of the lens of the eyes for medical staff.


Assuntos
Cristalino , Exposição Ocupacional , Monitoramento de Radiação , Calibragem , Humanos , Exposição Ocupacional/análise , Doses de Radiação , Dosímetros de Radiação , Monitoramento de Radiação/métodos
18.
Artigo em Inglês | MEDLINE | ID: mdl-36554706

RESUMO

Interventional radiology (IR) physicians must be equipped with personal passive dosimeters and personal protective equipment (PPE); however, they are inconsistently used. Therefore, we aimed to explore practical measures to increase PPE usage and ascertain whether these measures could lead to an actual decrease in exposure doses to IR physicians. Dosimeters and PPE were visually inspected. Then, a pre-operative briefing was conducted as a direct intervention, and the use of dosimeters and PPE was verbally confirmed. Finally, the intervention effect was verified by measuring the use rates and individual exposure doses. Because of the intervention, the use rate markedly improved and was almost 100%. However, both the effective dose rate (effective dose/fluoroscopy time) and the lens equivalent dose rate (lens equivalent dose/fluoroscopy time) showed that the intervention led to a statistically significant increase in exposure (effective dose rate: p = 0.033; lens equivalent dose rate: p = 0.003). In conclusion, the proper use of dosimeters and PPE raised the radiation exposure values for IR physicians immediately after the intervention, which was hypothesized to be due to the inclusion of exposure overlooked to date and the changes in the dosimeter management method from a single- to a double-dosimeter approach.


Assuntos
Cristalino , Exposição Ocupacional , Médicos , Humanos , Dosímetros de Radiação , Radiologia Intervencionista , Equipamento de Proteção Individual , Exposição Ocupacional/prevenção & controle , Doses de Radiação
19.
J Neuroendovasc Ther ; 16(7): 354-360, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37502341

RESUMO

Objective: To meet the new standard of the annual dose limit for the eye lens recommended by the International Commission on Radiation Protection, radiation doses of neuroendovascular procedures in Japanese institutions were investigated. Methods: Radiation doses to operators involved in 304 neuroendovascular procedures at 30 Japanese institutions were prospectively surveyed. The institutions recruited at an annual meeting of the Japanese Society for Neuroendovascular Therapy participated voluntarily. A maximum of 10 wireless dosimeters were attached to the radiation protection (RP) goggles, the ceiling-mounted RP shielding screen, and the operators' forehead and neck over the protective clothing. Doses recorded inside the goggles were defined as eye lens doses for operators who wore RP goggles, while doses to the forehead were defined as eye lens doses for those who did not. The shielding effect rates of the protection devices were calculated, and statistical analysis was performed for the comparison of radiation doses. Results: From 296 analyzed cases, mean eye lens radiation doses per procedure were 0.088 mGy for the left eye and 0.041 mGy for the right eye. For the left eye, that dose without RP equipment was 0.176 mGy and that with RP goggles plus an RP shielding screen was 0.034 mGy. Four parameters, including left eye dose, air kerma at the patient entrance reference point, fluoroscopic time, and the total number of frames, were assessed for five types of neurovascular procedures. Of them, transarterial embolization for dural arteriovenous fistula was associated with the highest eye lens dose at 0.138 mGy. The shielding effect rates of protection goggles were 60% for the left and 55% for the right RP goggle. The mean doses to the inner and outer surfaces of the RP shielding screen were 0.831 mGy and 0.040 mGy, respectively, amounting to a shielding effect rate of 95%. Conclusion: To meet the new standard, both RP goggles and RP shielding screens are strongly recommended to be used effectively. Without proper use of radiological protection devices, the number of neuroendovascular procedures that one operator performs per year will be limited under the new guideline.

20.
Radiat Prot Dosimetry ; 198(18): 1377-1386, 2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-36062449

RESUMO

The purpose of this study was to evaluate the effectiveness of organ effect modulation (OEM) in reducing the lens dose in 4D computed tomography (CT) of the head in volume-acquisition (NVA) mode. Six radiophotoluminescent dosemeters were placed on the head of a RANDO phantom. The doses absorbed by the organs and image noise change rate were determined. The lens doses without OEM (i.e. in the OEMoff case) were higher than those with the same target standard deviation and volume-computed tomography dose index (CTDIvol) as in the OEMoff case (p < 0.01). The image noise change rate was 11%. OEM reduced the lens dose during head 4D CT imaging in the NVA mode by 18%. Furthermore, the feasibility of lens dose reduction while ensuring sufficient image quality was confirmed under the condition in which OEM was employed with the same CTDIvol as in the OEMoff case.


Assuntos
Tomografia Computadorizada Quadridimensional , Cristalino , Doses de Radiação , Imagens de Fantasmas , Cabeça/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA