Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Adv Exp Med Biol ; 1395: 347-350, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36527660

RESUMO

Tissue oxygen saturation (StO2) is a crucial factor in the aetiology of pressure injury (PI), since hypoxia leads to necrotization. Pressure on the tissue occludes blood circulation and reduces the StO2, resulting in hypoxia. PI causes severe suffering, heals slowly and is expensive to treat. Hence it is important to prevent PI by detecting hypoxia, e.g., by near-infrared spectroscopy (NIRS) monitoring of StO2. For this, the NIRS device has to be wearable for a long time and it is crucial that it provokes no pressure itself. An integration of optical fibres into a textile achieves this. The aim was to investigate the feasibility of such a textile NIRS device.Knots and loops were tested as textile light emitters (LEs) or detectors (LDs) on a phantom. The light coupling efficiency of the LEs and LDs was investigated.Results show that knots perform similarly to loops. More loops per fibre increase efficiency both in LEs and in LDs. The best trade-off is at 3 loops. LEs are slightly more efficient than LDs, with an average attenuation from baseline of about -2 dB for loops of 0.5 mm diameter. Adding fibres multiplies the signal by the number of fibres. Inclusions mimicking hypoxia in phantoms were successfully identified. In-vivo arm occlusion tests showed the expected decrease in StO2. This shows feasibility of optical fibres in a textile to prevent PI.


Assuntos
Fibras Ópticas , Oxigênio , Humanos , Polímeros , Estudos de Viabilidade , Saturação de Oxigênio , Têxteis , Hipóxia , Consumo de Oxigênio
2.
Adv Exp Med Biol ; 1395: 411-416, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36527671

RESUMO

The present work aims to develop a wearable, textile-integrated NIRS-based tissue oxygen saturation (StO2) monitor for alerting mobility-restricted individuals - such as paraplegics - of critical tissue oxygen de-saturation in the regions such as the sacrum and the ischial tuberosity; these regions are proven to be extremely susceptible to the development of pressure injuries (PI).Using a combination of numerical methods including finite element analysis, image reconstruction, stochastic gradient descent with momentum (SGDm) and genetic algorithms, a methodology was developed to define the optimal combination of wavelengths and source-detector geometry needed for measuring the StO2 in tissue up to depths of 3 cm. The sensor design was optimised to account for physiologically relevant adipose tissue thicknesses (ATT) between 1 mm and 5 mm. The approach assumes only a priori knowledge of the optical properties of each of the three tissue layers used in the model (skin, fat, muscle) based on the absorption and scattering coefficients of four chromophores (O2Hb, HHb, H2O and lipid).The results show that the selected wavelengths as well as the source-detector geometries and number of sources and detectors depend on ATT and the degree and volume of the hypoxic regions. As a result of a genetic algorithm used to combine the various optimised designs into a single sensor layout, a group of four wavelengths was chosen, coinciding with the four chromophores and agreeing very well with literature. The optimised number of source points and detector points and their geometry resulted in good reconstruction of the StO2 across a wide range of layer geometries.


Assuntos
Saturação de Oxigênio , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Oxigênio , Consumo de Oxigênio/fisiologia , Hipóxia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA