Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Invest Ophthalmol Vis Sci ; 48(5): 2095-8, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17460266

RESUMO

PURPOSE: It is not known whether the prostaglandin FP receptor plays an important role in endogenous 24-hour regulation of intraocular pressure. The purpose of this study was to compare 24-hour intraocular pressure (IOP) in FP receptor-knockout mice with that of wild-type mice that have normal FP receptor expression. METHODS: The 24-hour IOP profile was determined by rebound tonometry in FP-knockout and wild-type mice. Peak and trough IOP was then measured by microneedle cannulation of the anterior chamber in homozygous (FP(-/-); n = 8), heterozygous (FP(+/-); n = 14), and C57BL/6 background strain mice (FP(+/+); n = 11). To confirm any differences in baseline IOP between genotypes, midafternoon IOP was also measured in a larger, separate group of FP(-/-) mice (n = 20), FP(+/-) mice (n = 49), and FP(+/+) (n = 23) wild-type littermates. RESULTS: Trough IOPs were measured between 10 AM and 12 PM, peak IOPs were measured between 8 and 10 PM. For FP(+/+), FP(+/-), and FP(-/-) mice trough IOP was 16.2, 15.3, and 15.1 mm Hg and peak IOPs were 18.2, 18.4, and 17.7 mm Hg, respectively. There was no significant difference among genotypes for mean peak or mean trough IOP or for peak-trough difference in IOP among genotypes (P > 0.05, ANOVA). In addition, there was no significant difference in midafternoon IOP between genotypes in a larger population (n = 92) of FP-knockout and wild-type mice. CONCLUSIONS: An intact FP receptor does not appear to be critical for normal 24-hour IOP regulation in the mouse eye.


Assuntos
Ritmo Circadiano/fisiologia , Pressão Intraocular/fisiologia , Receptores de Prostaglandina/fisiologia , Animais , Feminino , Genótipo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Tonometria Ocular
2.
Invest Ophthalmol Vis Sci ; 46(12): 4571-7, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16303950

RESUMO

PURPOSE: To determine the effect of bimatoprost on intraocular pressure in the prostaglandin FP receptor knockout mouse. METHODS: The IOP response to a single 1.2-microg (4 microL) dose of bimatoprost was measured in the treated and untreated fellow eyes of homozygote (FP+/+, n = 9) and heterozygote (FP+/-, n = 10) FP-knockout mice, as well as in wild-type C57BL/6 mice (FP+/+, n = 20). Serial IOP measurements were also performed after topical bimatoprost in a separate generation of homozygous FP-knockout mice and wild-type littermate control animals (n = 4 per group). Aqueous humor protein concentrations were measured to establish the state of the blood-aqueous barrier. Tissue, aqueous humor and vitreous concentrations of bimatoprost, latanoprost, and their C-1 free acids were determined by liquid chromatography and tandem mass spectrometry. RESULTS: A significant reduction in IOP was observed in the bimatoprost-treated eye of wild-type mice at 2 hours, with a mean difference and 95% confidence interval (CI) of the difference in means of -1.33 mm Hg (-0.81 to -1.84). Bimatoprost did not lead to a significant reduction in IOP in either the heterozygous knockout -0.36 mm Hg (-0.82 to +0.09) or homozygous FP-knockout mice 0.25 mm Hg (-0.38 to +0.89). The lack of an IOP response in the FP-knockout mice was not a consequence of blood-aqueous barrier breakdown, as there was no significant difference in aqueous humor protein concentration between treated and fellow eyes. Tissue and aqueous humor concentrations of bimatoprost, latanoprost, and their C-1 free acids indicate that latanoprost, but not bimatoprost, is hydrolyzed in the mouse eye after topical administration. CONCLUSIONS: An intact FP receptor gene is critical to the IOP response to bimatoprost in the mouse eye.


Assuntos
Anti-Hipertensivos/farmacologia , Pressão Intraocular/efeitos dos fármacos , Lipídeos/farmacologia , Receptores de Prostaglandina/fisiologia , Amidas , Animais , Anti-Hipertensivos/farmacocinética , Humor Aquoso/metabolismo , Bimatoprost , Barreira Hematoaquosa/fisiologia , Cloprostenol/análogos & derivados , Proteínas do Olho/metabolismo , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Lipídeos/farmacocinética , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Soluções Oftálmicas/farmacocinética , Soluções Oftálmicas/farmacologia , Receptores de Prostaglandina/deficiência , Tonometria Ocular
3.
Exp Eye Res ; 82(6): 1094-9, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16466714

RESUMO

Assessment of the accuracy of non-invasive rebound tonometry, and comparison with invasive cannulation tonometry. An in vivo calibration technique was devised to improve the accuracy of the rebound tonometer. IOP was then measured in SW mice using both rebound and cannulation tonometry. The ability of the rebound tonometer to accurately measure small IOP reductions after instillation of a topical prostaglandin was also determined. With the rebound method, mid-afternoon IOP in two groups of similar aged SW mice was 15.9+/-3.9 mmHg (mean+/-s.d., n=25) compared to 16.3+/-1.2 mmHg (n=32) using the cannulation technique. This difference was not statistically significant (p=0.6). For serial measurements using both techniques in the same eyes of a third group of SW mice (n=14), mean IOP was 15.0+/-3.9 mmHg for rebound tonometry but only 13.4+/-2.3 mmHg for subsequent cannulation tonometry. This effect was subsequently shown to be a consequence of the rebound tonometry, as multiple rebound measurements induced a statistically significant reduction in IOP. The average IOP reduction observed 2 hr after a single application of topical latanoprost (200 ng) was 2.8+/-1.3 mmHg (p<0.001) and 2.4+/-4.7 mmHg (p=0.03) with cannulation and rebound tonometers, respectively. These differences were not significantly different (p=0.8). In vivo calibration of the rebound tonometer increased measurement accuracy and provided IOP values within the physiological range that agreed closely with the IOP measured by cannulation tonometry. However, IOP measurement with the rebound tonometer had larger variability compared with the cannulation method. Repeat IOP measurements with the rebound tonometer led to a reduction in IOP. The rebound tonometer was sufficiently sensitive to detect a 2-3 mmHg reduction in IOP following application of topical latanoprost. Despite these limitations, the rebound tonometer has a significant advantage over cannulation tonometry in that it permits longitudinal IOP measurement in conscious mice.


Assuntos
Pressão Intraocular/fisiologia , Tonometria Ocular/métodos , Administração Tópica , Animais , Anti-Hipertensivos/administração & dosagem , Calibragem , Cateterismo/métodos , Pressão Intraocular/efeitos dos fármacos , Latanoprosta , Camundongos , Prostaglandinas F Sintéticas/administração & dosagem , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA