Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Scand J Gastroenterol ; 55(2): 228-235, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32024405

RESUMO

Objectives: Interpretation of MRI/MRCP in primary sclerosing cholangitis (PSC) at a single time point has low inter-reader agreement. Agreement of interpretation of the dynamic course of duct changes in follow-up MRI/MRCP is of clinical importance but remains unknown. Our aims are therefore to assess the inter-reader agreement of interpretation of the course of duct changes in PSC and investigate if elimination of 3 D MRCP affects inter-reader agreement.Materials and Methods: We studied 40 consecutive PSC-patients who underwent two liver MRI/MRCPs at two time points. Two readers independently evaluated the course of duct changes between the two time points in two imaging sets, one with and one without 3 D MRCP. The intraclass correlation coefficient (ICC) was calculated for evaluation of inter-reader and intra-reader agreement between the two time points and two imaging sets accordingly.Results: Inter-reader agreement of the interpretation of the course of duct changes between the two time points was poor (ICC up to 0.224). Elimination of 3 D MRCP neither improved inter-reader agreement which was again poor (ICC up to 0.26) nor did it change considerably the way readers interpret the course of ducts changes (ICC for intra-reader agreement between 0.809 and 0.978).Conclusions: Inter-reader agreement of the interpretation of radiological course of duct changes is poor in serial follow-up MRI/MRCP of PSC-patients. Elimination of 3 D MRCP does not increase inter-reader agreement but maintains an excellent intra-reader agreement for the interpretation of the dynamic course of bile duct changes.Key pointsInter-reader agreement of interpretation of radiological course of bile duct changes between serial follow-up MRI/MRCP examinations of patients with PSC is poor.Absence of 3D MRCP does not affect considerably the way readers interpret the radiological course of bile ducts changes.When MRCP is absent or of low quality, utilization of other sequences seems to be helpful as an alternative for bile duct evaluation.


Assuntos
Colangiopancreatografia por Ressonância Magnética/métodos , Colangite Esclerosante/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Idoso , Neoplasias dos Ductos Biliares/diagnóstico , Ductos Biliares/patologia , Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Ductos Biliares Intra-Hepáticos/patologia , Colangiopancreatografia Retrógrada Endoscópica , Competência Clínica , Constrição Patológica/diagnóstico , Diagnóstico Diferencial , Prova Pericial , Feminino , Humanos , Imageamento Tridimensional , Cirrose Hepática/diagnóstico , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
2.
Radiology ; 289(1): 111-118, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29916772

RESUMO

Purpose To develop and evaluate a triple arterial phase CT liver protocol with a similar radiation dose to that of standard single arterial phase CT in study subjects suspected of having hepatocellular carcinoma (HCC). Materials and Methods The study consisted of a retrospective part A for protocol development (n = 15) and a prospective part B to evaluate diagnostic accuracy (n = 38). All 53 participants underwent perfusion CT with 50 mL contrast material between August 2013 and September 2014. Group B underwent an additional standard multiphasic liver CT examination with 120 mL of contrast material (range, 70-143 mL). Image sets from triple arterial phase imaging were reconstructed from perfusion CT by fusing images from three dedicated arterial time points. Triple arterial phase CT and standard single arterial phase CT were compared by two readers, who assessed subjective image quality and HCC detection rate. A third reader served as reference reader and assessed objective image quality. The paired Student t test, Wilcoxon signed rank test, jackknife alternative free-response receiver operating characteristic (JAFROC), and JAFROC curve were applied. Results The mean volume CT dose index was 11.6 mGy for triple arterial phase CT and 11.9 mGy for standard single arterial phase CT (P = .73). Triple arterial phase CT showed lower image noise and better contrast-to-noise ratio compared with standard single arterial phase CT (P < .001 and P = .032, respectively); however, there was no significant difference in lesion-to-liver-contrast ratio (P = .31). Subjective image quality was good for both protocols. The detection rate of the 65 HCC lesions was 82% for reader 1 and 83% for reader 2 at triple arterial phase CT and 80% for reader 1 and 77% for reader 2 at standard single arterial phase CT (P = .4). Conclusion Triple arterial phase imaging is feasible at the same radiation dose as that used for standard single arterial phase CT. Triple arterial phase imaging provides equivalent to superior image quality and equal HCC detection rate despite the use of less than half the contrast material dose used at standard single arterial phase CT. © RSNA, 2018.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos
3.
Acta Radiol ; 59(11): 1309-1315, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29486599

RESUMO

Background Computed tomography (CT) for excluding acute aortic syndrome (AAS) and pulmonary embolism (PE) simultaneously in patients with chest pain could be used to exclude coronary artery disease (CAD). Purpose To evaluate the frequency of further testing for CAD in patients receiving a CT in the emergency department (ED) for simultaneous evaluation for AAS and PE. Material and Methods This retrospective study was conducted over a three-year period including all patients with acute chest pain visiting our ED. All patients were included that received an electrocardiography (ECG)-gated CT of the entire chest enquiring simultaneously for AAS and PE. Those patients were followed up for 30 days after their initial ED visit whether they received further testing for CAD. Results Within the study period, a total of 157 patients with acute chest pain received a chest pain CT for simultaneous evaluation of both AAS and PE. Image quality was deemed sufficient to evaluate the coronary arteries in 80% of the patients. Thirty-seven patients (24%) underwent additional testing for CAD within 30 days of their ED visit, including catheter coronary angiography (n = 25), cardiac-stress single-photon emission-CT (n = 6), and cardiac magnetic resonance imaging (MRI) (n = 6). Conclusion Of patients presenting to the ED with acute chest pain who received a chest pain CT for simultaneous evaluation of AAS and PE, 24% had further imaging for CAD within 30 days of the initial ED visit. Immediate evaluation of the coronary arteries as part of a chest pain CT should be considered here for not delaying diagnosis.


Assuntos
Dor no Peito/etiologia , Dor no Peito/fisiopatologia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Serviço Hospitalar de Emergência , Adulto , Idoso , Idoso de 80 Anos ou mais , Dor no Peito/diagnóstico por imagem , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
4.
Radiology ; 280(3): 960-8, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26937711

RESUMO

Purpose To prospectively develop individualized low-volume contrast media (CM) protocols adapted to tube voltage in patients undergoing computed tomographic (CT) angiography of the aorta. Materials and Methods The study was approved by the institutional review board and local ethics committee. All patients provided written informed consent. CT angiography was performed by using automated attenuation-based tube voltage selection (ATVS) (range, 70-150 kVp; 10-kVp increments). Iodine attenuation curves from an ex vivo experiment in a phantom were used to design CM protocols for CT angiography of the thoracoabdominal aorta in 129 consecutive patients (hereafter, cohort A). Further modified CM protocols based on results in cohort A were designed with the aim of homogeneous vascular attenuation of 300-350 HU across tube voltages and were applied to another 61 consecutive patients (cohort B). Three independent blinded radiologists assessed subjective image quality, and one reader determined objective image quality. The Kruskal-Wallis test was performed to test for differences in subjective image quality, and linear regression was performed to test for differences in objective image quality between the automatically selected tube voltages. Results Experiments revealed tube voltage-dependent iodine attenuation curves, which were used to determine the CM protocols in cohort A; these ranged from 68 mL at 110 kVp to 45 mL at 80 kVp. In both cohorts, ATVS selected 80 kVp in 62 patients, 90 kVp in 84, 100 kVp in 33, and 110 kVp in 11. In cohort A, image quality that was satisfactory or better was attained in 126 (98%) of 129 patients who had no significant differences in subjective image quality between tube voltages (P = .106) but who did have significant differences in attenuation and contrast-to-noise ratio (CNR) (P < .001 for both). In cohort B, the further-modified CM protocol (from 33 mL at 80 kVp to 68 mL at 110 kVp) yielded image quality that was satisfactory or better in all 61 (100%) patients, without significant differences in subjective image quality (P = .178), and without significant differences between tube voltage and attenuation (P = .108), noise (P = .250), or CNR (P = .698). Conclusion Individualized low-volume CM protocols based on automatically selected tube voltages are feasible and yield diagnostic image quality for CT angiography of the aorta. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador
5.
AJR Am J Roentgenol ; 206(2): 348-54, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26797362

RESUMO

OBJECTIVE: The purpose of this article is to investigate the magnitude of dose optimization for a manufacturer-recommended urolithiasis protocol in a second-generation dual-source CT scanner. MATERIALS AND METHODS: Custom renal phantoms with 24 stones were scanned using the manufacturer-provided dual-energy CT protocol (tube A, 100 kVp and 210 reference mAs; tube B, 140 kVp and 162 reference mAs) and seven dose-optimized protocols in which the reference tube current-time product setting of tube A was reduced stepwise by 20 mAs. Detection and characterization of the stones was assessed. In the patient study, 25 patients underwent the manufacturer-provided dual-energy protocol and 25 patients underwent imaging with a dose-optimized protocol (tube A, 100 kVp and 90 reference mAs; tube B, 140 kVp and 70 reference mAs). Dose-length product (DLP), image noise, and contrast-to-noise ratio (CNR) were assessed. Subjective image quality was analyzed by three independent radiologists. RESULTS: In the phantom study, the reference tube current-time product of tube A could be reduced from 210 to 90 mAs without losing the accuracy of detection or characterization of the calculi. In the patient study, the dose-optimized protocol resulted in a significant reduction of the average DLP by 51% compared with the standard protocol (219.4 vs 443.5 mGy·cm, respectively; p = 0.0001). The image noise was higher, and the CNR was lower, in the dose-optimized group than in the standard-dose group (p < 0.05). The subjective overall image quality of the dose-optimized CT examinations was rated as good, and that of the standard-dose CT examinations was rated as excellent (p = 0.001). CONCLUSION: The in vitro and in vivo assessment revealed a potential for a 51% dose reduction of the manufacturer-recommended dual-energy CT protocol for urolithiasis without compromising the accuracy.


Assuntos
Cálculos Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Protocolos Clínicos , Relação Dose-Resposta à Radiação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação
6.
Radiology ; 277(1): 64-72, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25942503

RESUMO

PURPOSE: To investigate the accuracy of x-ray grating interferometry phase-contrast (PC) imaging for the characterization of human coronary artery plaque. MATERIALS AND METHODS: PC and conventional absorption computed tomographic (CT) imaging was performed ex vivo in this institutional review board-approved study in 40 human coronary artery segments by using a synchrotron radiation source. Qualitative analyses and calculations of image quality (McNemar test), plaque components (McNemar test), and plaque classification (Cohen κ test) according to the American Heart Association classification were performed in 38 plaques detected at histopathologic examination (reference standard). Quantitative measurements of plaque components (ie, collagen, lipids, smooth muscle, and calcifications) were compared among PC and absorption images by using analysis of variance for repeated measures with post hoc Bonferroni correction. RESULTS: Image quality was superior in PC (median image score, 1) in all cases (100%) compared with absorption imaging (median image score, 3) (P < .001). Plaque components were detected by means of PC without significant differences (seven of seven calcifications, 22 of 22 plaques with collagen and smooth muscle cells, P > .99; 29 of 29 plaques with lipids, P = .10) with histopathologic findings, whereas absorption imaging was used to detect calcifications (seven of seven, P > .99) without statistical differences only (nine of 29 plaques with lipids, 0 of 22 plaques with collagen and smooth muscle cells, P < .001). Accuracy for plaque stage assessment with PC (early vs advanced) was 100%, and characterization was correct in 33 of 38 plaques (87%), while conventional absorption imaging allowed correct characterization of seven plaques only (18%, P < .001). PC CT numbers were significantly different (P < .05) for all plaque components (mean for calcifications, 1236 HU ± 69; collagen, 78 HU ± 24; lipids, -18 HU ± 23; and smooth muscle cells, 34 HU ± 12), whereas absorption images showed significant differences (P < .001) between calcifications (1336 HU ± 241) and other plaque components, but not for collagen (22 HU ± 13), lipids (-15 HU ± 14), and smooth muscle (13 HU ± 9) (P > .99). CONCLUSION: PC imaging allows accurate characterization of human coronary artery plaques and quantitative assessment of plaque components, thereby outperforming absorption imaging.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Tomografia Computadorizada por Raios X , Adulto , Cadáver , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/complicações , Reprodutibilidade dos Testes , Adulto Jovem
7.
Eur Radiol ; 24(3): 657-67, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24154792

RESUMO

OBJECTIVES: To determine the value of combined automated attenuation-based tube-potential selection and iterative reconstructions (IRs) for optimising computed tomography (CT) imaging of hypodense liver lesions. METHODS: A liver phantom containing hypodense lesions was imaged by CT with and without automated attenuation-based tube-potential selection (80, 100 and 120 kVp). Acquisitions were reconstructed with filtered back projection (FBP) and sinogram-affirmed IR. Image noise and contrast-to-noise ratio (CNR) were measured. Two readers marked lesion localisation and rated confidence, sharpness, noise and image quality on a five-point scale (1 = worst, 5 = best). RESULTS: Image noise was lower (31-52%) and CNR higher (43-102%) on IR than on FBP images at all tube voltages. On 100-kVp and 80-kVp IR images, confidence and sharpness were higher than on 120-kVp FBP images. Scores for image quality score and noise as well as sensitivity for 100-kVp IR were similar or higher than for 120-kVp FBP and lower for 80-kVp IR. Radiation dose was reduced by 26% at 100 kVp and 56% at 80 kVp. CONCLUSIONS: Compared with 120-kVp FBP images, the combination of automated attenuation-based tube-potential selection at 100 kVp and IR provides higher image quality and improved sensitivity for detecting hypodense liver lesions in vitro at a dose reduced by 26%. KEY POINTS: • Combining automated tube voltage selection/iterative CT reconstruction improves image quality. • Attenuation values remain stable on IR compared with FBP images. • Lesion detection was highest on 100-kVp IR images.


Assuntos
Hepatopatias/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Testes de Função Hepática , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Sensibilidade e Especificidade , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas
8.
Eur Radiol ; 24(7): 1455-65, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24817083

RESUMO

OBJECTIVE: To determine the best predictor for the response to and survival with transarterial radioembolisation (RE) with (90)yttrium microspheres in patients with liver metastases. METHODS: Forty consecutive patients with liver metastases undergoing RE were evaluated with multiphase CT, perfusion CT and (99m)Tc-MAA SPECT. Arterial perfusion (AP) from perfusion CT, HU values from the arterial (aHU) and portal venous phase (pvHU) CT, and (99m)Tc-MAA uptake ratio of metastases were determined. Morphologic response was evaluated after 4 months and available in 30 patients. One-year survival was calculated with Kaplan-Meier curves. RESULTS: We found significant differences between responders and non-responders for AP (P < 0.001) and aHU (P = 0.001) of metastases, while no differences were found for pvHU (P = 0.07) and the (99m)Tc-MAA uptake ratio (P = 0.40). AP had a significantly higher specificity than aHU (P = 0.003) for determining responders to RE. Patients with an AP >20 ml/100 ml/min had a significantly (P = 0.01) higher 1-year survival, whereas an aHU value >55 HU did not discriminate survival (P = 0.12). The Cox proportional hazard model revealed AP as the only significant (P = 0.02) independent predictor of survival. CONCLUSION: Compared to arterial and portal venous enhancement and the (99m)Tc-MAA uptake ratio of liver metastases, the AP from perfusion CT is the best predictor of morphologic response to and 1-year survival with RE. KEY POINTS: • Perfusion CT allows for calculation of the liver arterial perfusion. • Arterial perfusion of liver metastases differs between responders and non-responders to RE. • Arterial perfusion can be used to select patients responding to RE.


Assuntos
Embolização Terapêutica/métodos , Neoplasias Hepáticas/diagnóstico , Imagem de Perfusão/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Radioisótopos de Ítrio/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia , Feminino , Seguimentos , Humanos , Injeções Intra-Arteriais , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Masculino , Microesferas , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/uso terapêutico , Resultado do Tratamento , Radioisótopos de Ítrio/uso terapêutico
9.
Eur Radiol ; 24(8): 1889-95, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24838737

RESUMO

OBJECTIVES: To evaluate image quality, maximal heart rate allowing for diagnostic imaging, and radiation dose of turbo high-pitch dual-source coronary computed tomographic angiography (CCTA). METHODS: First, a cardiac motion phantom simulating heart rates (HRs) from 60-90 bpm in 5-bpm steps was examined on a third-generation dual-source 192-slice CT (prospective ECG-triggering, pitch 3.2; rotation time, 250 ms). Subjective image quality regarding the presence of motion artefacts was interpreted by two readers on a four-point scale (1, excellent; 4, non-diagnostic). Objective image quality was assessed by calculating distortion vectors. Thereafter, 20 consecutive patients (median, 50 years) undergoing clinically indicated CCTA were included. RESULTS: In the phantom study, image quality was rated diagnostic up to the HR75 bpm, with object distortion being 1 mm or less. Distortion increased above 1 mm at HR of 80-90 bpm. Patients had a mean HR of 66 bpm (47-78 bpm). Coronary segments were of diagnostic image quality for all patients with HR up to 73 bpm. Average effective radiation dose in patients was 0.6 ± 0.3 mSv. CONCLUSIONS: Our combined phantom and patient study indicates that CCTA with turbo high-pitch third-generation dual-source 192-slice CT can be performed at HR up to 75 bpm while maintaining diagnostic image quality, being associated with an average radiation dose of 0.6 mSv. KEY POINTS: • CCTA is feasible with the turbo high-pitch mode. • Turbo high-pitch CCTA provides diagnostic image quality up to 73 bpm. • The radiation dose of high-pitch CCTA is 0.6 mSv on average.


Assuntos
Artefatos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Imageamento Tridimensional , Tomografia Computadorizada Multidetectores/métodos , Imagens de Fantasmas , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Reprodutibilidade dos Testes
10.
J Vasc Interv Radiol ; 25(5): 747-59, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24630751

RESUMO

PURPOSE: To evaluate computed tomography (CT) perfusion for assessment of early treatment response after transarterial radioembolization of patients with liver malignancy. MATERIALS AND METHODS: Dynamic contrast-enhanced CT liver perfusion was performed before and 4 weeks after transarterial radioembolization in 40 patients (25 men and 15 women; mean age, 64 y ± 11; range, 35-80 y) with liver metastases (n = 27) or hepatocellular carcinoma (HCC) (n = 13). Arterial perfusion (AP) of tumors derived from CT perfusion and tumor diameters were measured on CT perfusion before and after transarterial radioembolization. Success of transarterial radioembolization was evaluated on morphologic follow-up imaging (median follow-up time, 4 mo) based on Response Evaluation Criteria in Solid Tumors (Version 1.1). CT perfusion parameters before and after transarterial radioembolization for different response groups were compared. Kaplan-Meier curves were plotted to illustrate overall 1-year survival rates. RESULTS: Liver metastases showed significant differences in AP before and after transarterial radioembolization in responders (P < .05) but not in nonresponders (P = .164). In HCC, AP values before and after transarterial radioembolization were not significantly different in responders and nonresponders (P = .180 and P = .052). Tumor diameters were not significantly different on CT perfusion before and after transarterial radioembolization in responders and nonresponders with liver metastases and HCC (P = .654, P = .968, P = .148, P = .164). In patients with significant decrease of AP in liver metastases after transarterial radioembolization, 1-year overall survival was significantly higher than in patients showing no reduction of AP. CONCLUSIONS: CT perfusion showed early reduction of AP in liver metastases responding to transarterial radioembolization; tumor diameter remained unchanged early after treatment. No significant early treatment response to transarterial radioembolization was found in patients with HCC. In patients with liver metastases, a decrease of AP after transarterial radioembolization was associated with a higher 1-year overall survival rate.


Assuntos
Angiografia/métodos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Tomografia Computadorizada por Raios X/métodos , Radioisótopos de Ítrio/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/uso terapêutico , Resultado do Tratamento
11.
AJR Am J Roentgenol ; 202(2): 368-74, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24450679

RESUMO

OBJECTIVE: The purpose of this article was to assess the effect of an integrated circuit (IC) detector for abdominal CT on image quality. MATERIALS AND METHODS: In the first study part, an abdominal phantom was scanned with various extension rings using a CT scanner equipped with a conventional discrete circuit (DC) detector and on the same scanner with an IC detector (120 kVp, 150 effective mAs, and 75 effective mAs). In the second study part, 20 patients were included who underwent abdominal CT both with the IC detector and previously at similar protocol parameters (120 kVp tube current-time product and 150 reference mAs using automated tube current modulation) with the DC detector. Images were reconstructed with filtered back projection. RESULTS: Image quality in the phantom was higher for images acquired with the IC compared with the DC detector. There was a gradually increasing noise reduction with increasing phantom sizes, with the highest (37% in the largest phantom) at 75 effective mAs (p < 0.001). In patients, noise was overall significantly (p = 0.025) reduced by 6.4% using the IC detector. Similar to the phantom, there was a gradual increase in noise reduction to 7.9% in patients with a body mass index of 25 kg/m(2) or lower (p = 0.008). Significant correlation was found in patients between noise and abdominal diameter in DC detector images (r = 0.604, p = 0.005), whereas no such correlation was found for the IC detector (r = 0.427, p = 0.060). CONCLUSION: Use of an IC detector in abdominal CT improves image quality and reduces image noise, particularly in overweight and obese patients. This noise reduction has the potential for dose reduction in abdominal CT.


Assuntos
Obesidade/complicações , Radiografia Abdominal/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
12.
Radiology ; 268(1): 237-44, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23513244

RESUMO

PURPOSE: To assess the value of iterative frequency split-normalized (IFS) metal artifact reduction (MAR) for computed tomography (CT) of hip prostheses. MATERIALS AND METHODS: This study had institutional review board and local ethics committee approval. First, a hip phantom with steel and titanium prostheses that had inlays of water, fat, and contrast media in the pelvis was used to optimize the IFS algorithm. Second, 41 consecutive patients with hip prostheses who were undergoing CT were included. Data sets were reconstructed with filtered back projection, the IFS algorithm, and a linear interpolation MAR algorithm. Two blinded, independent readers evaluated axial, coronal, and sagittal CT reformations for overall image quality, image quality of pelvic organs, and assessment of pelvic abnormalities. CT attenuation and image noise were measured. Statistical analysis included the Friedman test, Wilcoxon signed-rank test, and Levene test. RESULTS: Ex vivo experiments demonstrated an optimized IFS algorithm by using a threshold of 2200 HU with four iterations for both steel and titanium prostheses. Measurements of CT attenuation of the inlays were significantly (P < .001) more accurate for IFS when compared with filtered back projection. In patients, best overall and pelvic organ image quality was found in all reformations with IFS (P < .001). Pelvic abnormalities in 11 of 41 patients (27%) were diagnosed with significantly (P = .002) higher confidence on the basis of IFS images. CT attenuation of bladder (P < .001) and muscle (P = .043) was significantly less variable with IFS compared with filtered back projection and linear interpolation MAR. In comparison with that of FBP and linear interpolation MAR, noise with IFS was similar close to and far from the prosthesis (P = .295). CONCLUSION: The IFS algorithm for CT image reconstruction significantly reduces metal artifacts from hip prostheses, improves the reliability of CT number measurements, and improves the confidence for depicting pelvic abnormalities.


Assuntos
Artefatos , Prótese de Quadril , Metais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Meios de Contraste , Diatrizoato de Meglumina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estatísticas não Paramétricas
13.
Eur Radiol ; 23(10): 2687-94, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23686292

RESUMO

PURPOSE: To determine the value of a metal artefact reduction (MAR) algorithm with iterative reconstructions for dental hardware in carotid CT angiography. METHODS: Twenty-four patients (six of which were women; mean age 70 ± 12 years) with dental hardware undergoing carotid CT angiography were included. Datasets were reconstructed with filtered back projection (FBP) and using a MAR algorithm employing normalisation and an iterative frequency-split (IFS) approach. Three blinded, independent readers measured CT attenuation values and evaluated image quality and degrees of artefacts using axial images, multi-planar reformations (MPRs) and maximal intensity projections (MIP) of the carotid arteries. RESULTS: CT attenuation values of the internal carotid artery on images with metal artefacts were significantly higher in FBP (324 ± 104HU) datasets compared with those reconstructed with IFS (278 ± 114HU; P < 0.001) and with FBP on images without metal artefacts (293 ± 106HU; P = 0.006). Quality of IFS images was rated significantly higher on axial, MPR and MIP images (P < 0.05, each), and readers found significantly less artefacts impairing the diagnostic confidence of the internal carotid artery (P < 0.05, each). CONCLUSION: The MAR algorithm with the IFS approach allowed for a significant reduction of artefacts from dental hardware in carotid CT angiography, hereby increasing image quality and improving the accuracy of CT attenuation measurements. KEY POINTS: • CT angiography of the neck has proven value for evaluating carotid disease • Neck CT angiography images are often degraded by artefacts from dental implants • A metal artefact reduction algorithm with iterative reconstruction reduces artefacts significantly • Visualisation of the internal carotid artery is improved.


Assuntos
Angiografia/métodos , Artefatos , Doenças das Artérias Carótidas/diagnóstico por imagem , Implantes Dentários , Metais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Artérias Carótidas/diagnóstico por imagem , Feminino , Humanos , Masculino , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
BMC Musculoskelet Disord ; 14: 343, 2013 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-24314152

RESUMO

BACKGROUND: Osteoarthritis is an increasing burden in an ageing population. Sports, especially when leading to an overstress of joints, is under suspicion to provoke or at least accelerate the genesis of osteoarthritis. We present the radiologic findings of a 49-years old ultra-endurance athlete with 35 years of training and competing, whose joints of the lower limbs were examined using three different types of magnetic resonance imaging, including a microscopic magnetic resonance imaging coil. To date no case report exists where an ultra-endurance athlete was examined such detailed regarding overuse-injuries of his joints. CASE PRESENTATION: A 49 years old, white, male ultra-endurance athlete reporting no pain during training and racing and with no significant injuries of the lower limbs in his medical history was investigated regarding signs of chronic damage or overuse injuries of the joints of his lower limbs. CONCLUSION: Despite the age of nearly 50 years and a training history of over 35 years, the athlete showed no signs of chronic damage or overuse injuries in the joints of his lower limbs. This leads to the conclusion that extensive sports and training does not compulsory lead to damages of the musculoskeletal system. This is a very important finding for all endurance-athletes as well as for their physicians.


Assuntos
Atletas/estatística & dados numéricos , Cartilagem Articular , Resistência Física , Humanos , Extremidade Inferior , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
15.
Skeletal Radiol ; 42(3): 419-29, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22926680

RESUMO

OBJECTIVE: To determine the optimal intra-articular iodine concentration for C-arm flat-panel computed tomography (FPCT) arthrography using advanced joint phantoms and to evaluate its application in human cadaveric wrists and elbows. Multi-detector (MD) CT served as the standard of reference. MATERIALS AND METHODS: Joint phantoms and 10 human cadaveric wrist and elbow joints were scanned with C-arm FPCT (5-s, 8-s, and 20-s runs) and standard MDCT using different and optimal concentrations of iodinated contrast material. CT numbers of contrast material, tissue, and noise were measured and contrast-to-noise ratios (CNR) calculated for quantitative analysis. Image and depiction of cartilage, bone, and soft tissues were rated. Radiation doses were compared. RESULTS: In FPCT, iodine concentrations positively correlated with CT numbers and noise of contrast material and with radiation dose (r = 0.713-0.996, p < 0.05 each). At an iodine concentration of 45 mg/ml, CNR of cartilage and soft tissues were highest for all FPCT acquisitions and higher than in MDCT. The 20-s FPCT run performed best for image quality and depiction of anatomical structures and was rated overall equal to MDCT (p = 0.857). CONCLUSION: The optimal iodine concentration for C-arm FPCT arthrography in this study is 45 mg/ml, leading to superior CNR and image quality for an optimal FPCT protocol compared with standard MDCT arthrography in human cadaveric joints.


Assuntos
Artrografia/instrumentação , Articulação do Cotovelo/diagnóstico por imagem , Iohexol/análogos & derivados , Tomografia Computadorizada por Raios X/instrumentação , Articulação do Punho/diagnóstico por imagem , Ecrans Intensificadores para Raios X , Artrografia/métodos , Cadáver , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Iohexol/administração & dosagem , Masculino , Projetos Piloto , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
17.
Cardiovasc Diagn Ther ; 10(4): 820-830, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32968637

RESUMO

BACKGROUND: Computed tomography (CT)-derived fractional flow reserve (FFRCT) enables the non-invasive functional assessment of coronary artery stenosis. We evaluated the feasibility and potential clinical role of FFRCT in patients presenting to the emergency department with acute chest pain who underwent chest-pain CT (CPCT). METHODS: For this retrospective IRB-approved study, we included 56 patients (median age: 62 years, 14 females) with acute chest pain who underwent CPCT and who had at least a mild (≥25% diameter) coronary artery stenosis. CPCT was evaluated for the presence of acute plaque rupture and vulnerable plaque features. FFRCT measurements were performed using a machine learning-based software. We assessed the agreement between the results from FFRCT and patient outcome (including results from invasive catheter angiography and from any non-invasive cardiac imaging test, final clinical diagnosis and revascularization) for a follow-up of 3 months. RESULTS: FFRCT was technically feasible in 38/56 patients (68%). Eleven of the 38 patients (29%) showed acute plaque rupture in CPCT; all of them underwent immediate coronary revascularization. Of the remaining 27 patients (71%), 16 patients showed vulnerable plaque features (59%), of whom 11 (69%) were diagnosed with acute coronary syndrome (ACS) and 10 (63%) underwent coronary revascularization. In patients with vulnerable plaque features in CPCT, FFRCT had an agreement with outcome in 12/16 patients (75%). In patients without vulnerable plaque features (n=11), one patient showed myocardial ischemia (9%). In these patients, FFRCT and patient outcome showed an agreement in 10/11 patients (91%). CONCLUSIONS: Our preliminary data show that FFRCT is feasible in patients with acute chest pain who undergo CPCT provided that image quality is sufficient. FFRCT has the potential to improve patient triage by reducing further downstream testing but appears of limited value in patients with CT signs of acute plaque rupture.

18.
Abdom Radiol (NY) ; 44(2): 652-660, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30225609

RESUMO

PURPOSE: To investigate the detectability of renal stones in corticomedullary and nephrographic phases on contrast-enhanced computed tomography (CT). METHODS: All consecutive patients between January 2012 and February 2016 undergoing CT of the kidneys according to our department's standard four-phase protocol and having at least one stone in the NC-phase (NCP) were included. Fifty patients with altogether 136 stones were eligible. Two radiologists in consensus evaluated the NCP from each examination and documented the number, location, and size of stones. Three abdominal radiologists blinded to the findings of the NCP reviewed independently the corticomedullary and nephrographic phases on two different occasions. They reported the number and location of stones in each kidney. For the inter-observer agreement the intra-class correlation coefficient (ICC) was estimated. The detection rate of renal stones was calculated for the three radiologists and compared between the two contrast-enhanced phases and the results were analyzed with concern to the size of the stones. RESULTS: The ICC was 0.86. There was no statistically significant difference between corticomedullary and nephrographic phases (p = 0.94). The detection rate for stones measuring 3-5 mm was 82-88% and 98% for stones ≥ 6 mm. CONCLUSION: The detectability of renal stones ≥ 6 mm on contrast-enhanced CT is extremely high. This means that stones with a higher risk of not passing spontaneously can be safely diagnosed.


Assuntos
Meios de Contraste , Cálculos Renais/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Intensificação de Imagem Radiográfica/métodos , Idoso , Feminino , Humanos , Rim/diagnóstico por imagem , Masculino , Reprodutibilidade dos Testes
19.
Nutrition ; 59: 50-55, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30419500

RESUMO

OBJECTIVE: Although computed tomography (CT) is frequently used to determine body composition, the effects of using different CT protocols is not well known. The aim of this study was to determine whether contrast media phase, radiation dose, and slice thickness in CT affect body composition segmentation. METHODS: Clinically indicated perfusion CTs of the upper abdomen in 20 patients (seven women) between 40 and 87 y of age with high suspicion of hepatocellular carcinoma were analyzed retrospectively. Axial images from the L3 level with varying imaging delay were reconstructed after contrast media injection (18 images per patient), slice thickness (5 images, 2-10 mm), and radiation dose (4 images with one-third to four-thirds of standard dose). Muscle and fat areas were segmented semiautomatically by drawing regions of interests and using established cutoff thresholds. Skeletal muscle index (SMI), steatotic muscle area, and adipose tissue index, as well as muscle attenuation and fat attenuation, were evaluated. RESULTS: Average SMI increased by up to 2.8% after contrast media injection. Steatotic muscle area decreased by ≤13.8%, and adipose tissue index decreased by ≤6.5%. Muscle attenuation increased after contrast media injection, whereas fat attenuation decreased (all P < 0.001). SMI decreased by 1.9% on average when increasing slice thickness from 2 to 10 mm. Steatotic muscle area increased by ≤3.3%, and adipose tissue index increased by ≤1.5% (all P < 0.05). Muscle attenuation did not change significantly with reconstruction thickness. Radiation dose had no effect on estimated area of spinal muscle, fatty spinal muscle, or visceral fat. CONCLUSIONS: Contrast media have a strong effect on the evaluation of body composition, whereas the influence of slice thickness is less pronounced. Radiation dose can be reduced by ≥66% without significantly affecting segmentation.


Assuntos
Composição Corporal , Meios de Contraste , Erros de Diagnóstico , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Tecido Adiposo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/diagnóstico por imagem , Estudos Retrospectivos
20.
Phys Med ; 61: 58-63, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31151580

RESUMO

OBJECTIVE: To investigate if the conventional localizer radiograph (LR) can be replaced by a synthetic LR (SLR), generated from a low-dose spiral CT scan, for CT scan planning with minimal changes to current clinical workflows. METHODS: A dosimetric comparison of SLRs and LRs was made using Monte Carlo methods. Water equivalent diameters (WEDs) of a centered and mis-centered phantom were estimated from low-dose spiral CT scans and LRs acquired at different angles. Body sizes, in the form of two lengths and two diameters obtained from SLRs and LRs, were compared for 10 patients (4 men and 6 women with a mean age of 74.8 and 76.2 years respectively) undergoing CT of thorax and abdomen. The image quality of SLRs for CT scan planning relative to LRs was rated using a 5-grade scale by four radiologists and two CT radiographers. RESULTS: An SLR can be obtained at a comparable effective dose to that of traditionally acquired LRs: 0.14 mSv. WEDs from LRs were more affected by mis-centering than WEDs calculated from low-dose spiral scans. One significant discrepancy of estimated body sizes was observed, the broadest part of the patient that on lateral localizers showed a mean deviation of 17.7 mm (range: 7.3-28.7 mm, p < 0.001). The anteroposterior/posteroanterior SLR image quality was assessed as better compared to an LR while the same could not be shown for lateral localizers. CONCLUSIONS: SLRs based on low-dose spiral scans can replace LRs for CT planning.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Método de Monte Carlo , Doses de Radiação , Radiometria , Tomografia Computadorizada por Raios X/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA