RESUMO
BACKGROUND: Left ventricular (LV) systolic dysfunction worsens outcomes in patients undergoing percutaneous coronary intervention (PCI). The objective of this study, therefore, was to evaluate outcomes of pLVAD-supported high-risk PCI (HRPCI) patients according to LV ejection fraction (LVEF). METHODS: Patients from the PROTECT III study undergoing pLVAD-supported HRPCI were stratified according to baseline LVEF: severe LV dysfunction (LVEF <30%), mild and moderate LV dysfunction (LVEF ≥30% to <50%), or preserved LV function (LVEF ≥50%). Major adverse cardiovascular and cerebrovascular events (MACCE: composite of all-cause death, myocardial infarction, stroke/transient ischemic attack, and repeat revascularization), and PCI-related complications were assessed at 90 days and mortality was assessed at 1-year. RESULTS: From March 2017 to March 2020, 940 patients had evaluable baseline LVEF recorded in the study database. Patients with preserved LV function were older, more frequently presented with myocardial infarction, and underwent more left main PCI and atherectomy. Immediate PCI-related coronary complications were infrequent (2.7%, overall), similar between groups (P = 0.98), and not associated with LVEF. Unadjusted 90-day MACCE rates were similar among LVEF groups; however, as a continuous variable, LVEF was associated with both 90-day MACCE (adj.HR per 5% 0.89, 95% CI [0.80, 0.98], P = 0.018) and 1-year mortality (adj.HR per 5% 0.84 [0.78, 0.90], P <0.0001). CONCLUSIONS: Patients who underwent pLVAD-supported HRPCI exhibited low incidence of PCI-related complications, regardless of baseline LVEF. However, LVEF was associated with 90-day MACCE and 1-year mortality.
Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Disfunção Ventricular Esquerda , Humanos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Infarto do Miocárdio/complicações , Doença da Artéria Coronariana/complicaçõesRESUMO
BACKGROUND: Patients experiencing loss of pulse pressure (LOPP) during high-risk percutaneous coronary intervention (HR-PCI) are transiently dependent on mechanical circulatory support devices. We sought to define the frequency and clinic outcomes of patients who experience LOPP during HR-PCI. METHODS AND RESULTS: Patients enrolled in the PROTECT III study and had automated Impella controller logs capturing real-time hemodynamics were included in this analysis. A LOPP event was defined as a mean pulse pressure on Impella of <20 mm Hg for ≥5 seconds during PCI. Clinical characteristics and outcomes were then compared between those with and without LOPP. Logistic regression identified clinical and hemodynamic predictors of LOPP. We included 302 patients, of whom 148 patients (49%) experienced LOPP. Age, sex, and comorbidities were similar in patients with and without LOPP. Mean baseline systolic blood pressure (118.6 mm Hg vs 129.8 mm Hg; P < .001) and mean arterial pressure (86.9 mm Hg vs 91.6 mm Hg; Pâ¯=â¯.011) were lower in patients with LOPP, whereas heart rate (78 bpm vs 73 bpm; Pâ¯=â¯.012) was higher. Anatomical complexity was similar between groups. Patients with LOPP were more likely to experience major adverse cardiac and cerebrovascular events (23.5% vs 8.8%; Pâ¯=â¯.002), acute kidney injury (10.1% vs 2.6%; Pâ¯=â¯.030), and death (20.2% vs 7.9%; Pâ¯=â¯.008) within 90 days. A low baseline systolic blood pressure and cardiomyopathy were the strongest predictors of LOPP (Pâ¯=â¯.003 and Pâ¯=â¯.001, respectively). CONCLUSIONS: LOPP on Impella during HR-PCI was common and occurred more frequently in patients with cardiomyopathy and a low systolic blood pressure. LOPP was strongly associated with higher 90-day major adverse cardiac and cerebrovascular events, acute kidney injury, and mortality. Condensed Abstract We sought to define the frequency and clinic outcomes of patients who experience LOPP during high-risk percutaneous coronary intervention (HR-PCI). We included 302 patients, of whom 148 (49%) experienced LOPP. Patients with LOPP were more likely to experience major adverse cardiac and cerebrovascular events (23.5% vs 8.8%; Pâ¯=â¯.002), acute kidney injury (10.1% vs 2.6%; Pâ¯=â¯.030), and death (20.2% vs 7.9%; Pâ¯=â¯.008) within 90 days. A low baseline systolic blood pressure and cardiomyopathy were the strongest predictors of LOPP (Pâ¯=â¯.003 and Pâ¯=â¯.001, respectively).
Assuntos
Pressão Sanguínea , Coração Auxiliar , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Intervenção Coronária Percutânea/métodos , Idoso , Pessoa de Meia-Idade , Pressão Sanguínea/fisiologia , Resultado do Tratamento , Hipotensão/epidemiologia , Hipotensão/fisiopatologia , Hipotensão/etiologiaRESUMO
BACKGROUND: Coronary angiography and percutaneous coronary intervention (PCI) in patients with chronic kidney disease (CKD) is associated with increased risk of contrast induced nephropathy (CIN) and requirement for renal replacement therapy (RRT). OBJECTIVES: We aimed to evaluate our single center experience of ultra-low contrast PCI in patients with CKD and to characterize 1 year outcomes. METHODS: We performed a retrospective analysis of ultra-low contrast PCI at our institution between 2016 and 2022. Patients with CKD3b-5 (eGFR <45 mL/min/1.73m2), not on RRT who underwent ultra-low contrast PCI ( < 30 mL of contrast during PCI) were included. Primary outcomes included change in eGFR post-procedurally, and death, RRT requirement, and major adverse cardiac events (MACE) at 1 year follow-up. RESULTS: One hundred patients were included in the study. The median age was 67 years old and 28% were female. The median baseline eGFR was 21.5 mL/min/1.73m2 (IQR 14.08-32.0 mL/min/1.73m2). A median of 8.0 mL (IQR 0-15 mL) of contrast was used during PCI. Median contrast use to eGFR ratio was 0.37 (IQR 0-0.59). There was no significant difference between pre-and postprocedure eGFR (p = 0.84). At 1 year, 8% of patients died, 11% required RRT and 33% experienced MACE. The average time of RRT initiation was 7 months post-PCI. Forty-four patients were undergoing renal transplant evaluation, of which 17 (39%) received a transplant. CONCLUSIONS: In patients with advanced CKD, ultra-low contrast PCI is feasible and safe with minimal need for peri-procedural RRT. Moreover, ultra-low contrast PCI may allow for preservation of renal function in anticipation of renal transplantation.
Assuntos
Meios de Contraste , Angiografia Coronária , Doença da Artéria Coronariana , Taxa de Filtração Glomerular , Rim , Intervenção Coronária Percutânea , Insuficiência Renal Crônica , Terapia de Substituição Renal , Humanos , Feminino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Masculino , Estudos Retrospectivos , Insuficiência Renal Crônica/terapia , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/fisiopatologia , Insuficiência Renal Crônica/mortalidade , Idoso , Meios de Contraste/efeitos adversos , Meios de Contraste/administração & dosagem , Resultado do Tratamento , Pessoa de Meia-Idade , Fatores de Tempo , Fatores de Risco , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/complicações , Medição de Risco , Rim/fisiopatologiaRESUMO
BACKGROUND: Stent underexpansion, typically related to lesion calcification, is the strongest predictor of adverse events after percutaneous coronary intervention (PCI). Although uncommon, underexpansion may also occur in non-severely calcified lesions. AIM: We sought to identify the prevalence and anatomical characteristics of underexpansion in non-severely calcified lesions. METHODS: We included 993 patients who underwent optical coherence tomography-guided PCI of 1051 de novo lesions with maximum calcium arc <180°. Negative remodeling (NR) was the smallest lesion site external elastic lamina diameter that was also smaller than the distal reference. Stent expansion was evaluated using a linear regression model accounting for vessel tapering; underexpansion required both stent expansion <70% and stent area <4.5mm2. RESULTS: Underexpansion was observed in 3.6% of non-heavily calcified lesions (38/1051). Pre-stent maximum calcium arc and thickness were greater in lesions with versus without underexpansion (median 119° vs. 85°, p = 0.002; median 0.95 mm vs. 0.78 mm, p = 0.008). NR was also more common in lesions with underexpansion (44.7% vs. 24.5%, p = 0.007). In the multivariable logistic regression model, larger and thicker eccentric calcium, mid left anterior descending artery (LAD) location, and NR were associated with underexpansion in non-severely calcified lesions. The rate of underexpansion was especially high (30.7%) in lesions exhibiting all three morphologies. Two-year TLF tended to be higher in underexpanded versus non-underexpanded stents (9.7% vs. 3.7%, unadjusted hazard ratio [95% confidence interval] = 3.02 [0.92, 9.58], p = 0.06). CONCLUSION: Although underexpansion in the absence of severe calcium (<180°) is uncommon, mid-LAD lesions with NR and large and thick eccentric calcium were associated with underexpansion.
Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Intervenção Coronária Percutânea , Stents , Tomografia de Coerência Óptica , Calcificação Vascular , Humanos , Masculino , Feminino , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Prevalência , Fatores de Risco , Vasos Coronários/diagnóstico por imagem , Resultado do Tratamento , Estudos Retrospectivos , Índice de Gravidade de Doença , Desenho de Prótese , Valor Preditivo dos Testes , Fatores de Tempo , Angiografia Coronária , Remodelação VascularRESUMO
BACKGROUND: Although use of sirolimus-based analogs has shown superiority over paclitaxel in drug-eluting stents, the relative efficacy of these two agents released from drug-coated balloons (DCB) is unclear. The present meta-analysis is aimed to compare outcomes after percutaneous coronary intervention (PCI) with paclitaxel-coated balloons (PCB) versus sirolimus-coated balloons (SCB) for either in-stent restenosis or native de novo lesions. METHODS: The study outcomes were 1) target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or target lesion revascularization, and 2) follow-up angiographic parameters including late lumen loss (LLL), diameter stenosis, and minimal lumen diameter (MLD). Pooled odds ratios (OR) and weighted mean differences (WMD) with 95% confidence intervals (CI) were calculated by using random-effects models. RESULTS: A search of PubMed, EMBASE, and Cochrane Library from their inception to January 2024 identified five randomized clinical trials and three observational studies with a total of 1861 patients (889 in PCB and 972 in SCB groups). During 9-12 months of follow-up, there was no significant difference in TLF (OR 1.01, 95% CI 0.75-1.35) between the two groups. On follow-up angiography at 6-9 months, MLD (WMD 0.10, 95% CI 0.02-0.17) was larger in PCB but there was no statistically significant difference in LLL (WMD -0.11, 95% CI -0.23-0.02) and diameter stenosis (WMD -3.33, 95% CI -8.11-1.45). CONCLUSIONS: Among patients undergoing DCB-only PCI, the risk of TLF was similar during 9-12 months of follow-up after PCB and SCB treatment. However, the MLD was larger favoring PCB over SCB on follow-up angiography.
RESUMO
Importance: Drug-coated balloons offer a potentially beneficial treatment strategy for the management of coronary in-stent restenosis. However, none have been previously evaluated or approved for use in coronary circulation in the United States. Objective: To evaluate whether a paclitaxel-coated balloon is superior to an uncoated balloon in patients with in-stent restenosis undergoing percutaneous coronary intervention. Design, Setting, and Participants: AGENT IDE, a multicenter randomized clinical trial, enrolled 600 patients with in-stent restenosis (lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm) at 40 centers across the United States between May 2021 and August 2022. One-year clinical follow-up was completed on October 2, 2023. Interventions: Participants were randomized in a 2:1 allocation to undergo treatment with a paclitaxel-coated (n = 406) or an uncoated (n = 194) balloon. Main Outcomes and Measures: The primary end point of 1-year target lesion failure-defined as the composite of ischemia-driven target lesion revascularization, target vessel-related myocardial infarction, or cardiac death-was tested for superiority. Results: Among 600 randomized patients (mean age, 68 years; 157 females [26.2%]; 42 Black [7%], 35 Hispanic [6%] individuals), 574 (95.7%) completed 1-year follow-up. The primary end point at 1 year occurred in 17.9% in the paclitaxel-coated balloon group vs 28.6% in the uncoated balloon group, meeting the criteria for superiority (hazard ratio [HR], 0.59 [95% CI, 0.42-0.84]; 2-sided P = .003). Target lesion revascularization (13.0% vs 24.7%; HR, 0.50 [95% CI, 0.34-0.74]; P = .001) and target vessel-related myocardial infarction (5.8% vs 11.1%; HR, 0.51 [95% CI, 0.28-0.92]; P = .02) occurred less frequently among patients treated with paclitaxel-coated balloon. The rate of cardiac death was 2.9% vs 1.6% (HR, 1.75 [95% CI, 0.49-6.28]; P = .38) in the coated vs uncoated balloon groups, respectively. Conclusions and Relevance: Among patients undergoing coronary angioplasty for in-stent restenosis, a paclitaxel-coated balloon was superior to an uncoated balloon with respect to the composite end point of target lesion failure. Paclitaxel-coated balloons are an effective treatment option for patients with coronary in-stent restenosis. Trial Registration: ClinicalTrials.gov Identifier: NCT04647253.
Assuntos
Reestenose Coronária , Infarto do Miocárdio , Feminino , Humanos , Idoso , Paclitaxel , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Stents , Resultado do Tratamento , MorteRESUMO
BACKGROUND: Risk stratification before chronic total occlusion (CTO) percutaneous coronary intervention (PCI) is important to inform procedural planning as well as patients and their families. We sought to externally validate the PROGRESS-CTO complication risk scores in the OPEN-CTO registry. METHODS: OPEN-CTO is a prospective registry of 1000 consecutive CTO PCIs performed at 12 experienced US centers using the hybrid algorithm. Endpoints of interest were in-hospital all-cause mortality, need for pericardiocentesis, acute myocardial infarction (MI), and major adverse cardiovascular events (MACE) (a composite of all-cause mortality, stroke, periprocedural MI, urgent repeat revascularization, and tamponade requiring pericardiocentesis). Model discrimination was assessed with the area under the curve (AUC) method, and calibration with the observed-versus-predicted probability method. RESULTS: Mean age was 65.4 ± 10.3 year, and 36.5% of patients had prior coronary artery bypass graft. Overall, 41 patients (4.1%) suffered MACE, 9 (0.9%) mortality, 26 (2.6%) acute MI, and 11 (1.1%) required pericardiocentesis. Technical success was achieved in 86.3%. Patients who experienced MACE had higher anatomic complexity, and more often required antegrade dissection/reentry and the retrograde approach. Increasing PROGRESS-CTO MACE scores were associated with increasing MACE rates: 0.5% (score 0-1), 2.4% (score 2), 3.7% (score 3), 4.5% (score 4), 7.8% (score 5), 13.0% (score 6-7). The AUC were as follows: MACE 0.72 (95% confidence interval [CI]: 0.66-0.78), mortality 0.79 (95% CI: 0.66-0.95), pericardiocentesis 0.71 (95% CI: 0.60-0.82), and acute MI 0.57 (95% CI: 0.49-0.66). Calibration was adequate for MACE and mortality, while the models underestimated the risk of pericardiocentesis and acute MI. CONCLUSIONS: In a large external cohort of patients treated with the hybrid algorithm by experienced CTO operators, the PROGRESS-CTO MACE, mortality, and pericardiocentesis risk scores showed good discrimination, while the acute MI score had inferior performance.
Assuntos
Oclusão Coronária , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Pessoa de Meia-Idade , Idoso , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Oclusão Coronária/etiologia , Angiografia Coronária , Resultado do Tratamento , Fatores de Risco , Infarto do Miocárdio/etiologia , Sistema de Registros , Doença CrônicaRESUMO
Over the past 2 decades, chronic total occlusion (CTO) percutaneous coronary intervention has developed into its own subspecialty of interventional cardiology. Dedicated terminology, techniques, devices, courses, and training programs have enabled progressive advancements. However, only a few randomized trials have been performed to evaluate the safety and efficacy of CTO percutaneous coronary intervention. Moreover, several published observational studies have shown conflicting data. Part of the paucity of clinical data stems from the fact that prior studies have been suboptimally designed and performed. The absence of standardized end points and the discrepancy in definitions also prevent consistency and uniform interpretability of reported results in CTO intervention. To standardize the field, we therefore assembled a broad consortium comprising academicians, practicing physicians, researchers, medical society representatives, and regulators (US Food and Drug Administration) to develop methods, end points, biomarkers, parameters, data, materials, processes, procedures, evaluations, tools, and techniques for CTO interventions. This article summarizes the effort and is organized into 3 sections: key elements and procedural definitions, end point definitions, and clinical trial design principles. The Chronic Total Occlusion Academic Research Consortium is a first step toward improved comparability and interpretability of study results, supplying an increasingly growing body of CTO percutaneous coronary intervention evidence.
Assuntos
Oclusão Coronária/terapia , Vasos Coronários/fisiologia , Ensaios Clínicos como Assunto , Feminino , Humanos , MasculinoRESUMO
BACKGROUND: Despite successful primary percutaneous coronary intervention (PCI) in ST-elevation myocardial infarction (STEMI), myocardial salvage is often suboptimal, resulting in large infarct size and increased rates of heart failure and mortality. Unloading of the left ventricle (LV) before primary PCI may reduce infarct size and improve prognosis. STUDY DESIGN AND OBJECTIVES: STEMI-DTU (NCT03947619) is a prospective, randomized, multicenter trial designed to compare mechanical LV unloading with the Impella CP device for 30 minutes prior to primary PCI to primary PCI alone without LV unloading. The trial aims to enroll approximately 668 subjects, with a potential sample size adaptation, with anterior STEMI with a primary end point of infarct size as a percent of LV mass evaluated by cardiac magnetic resonance at 3-5 days after PCI. The key secondary efficacy end point is a hierarchical composite of the 1-year rates of cardiovascular mortality, cardiogenic shock ≥24 hours after PCI, use of a surgical left ventricular assist device or heart transplant, heart failure, intra-cardiac defibrillator or chronic resynchronization therapy placement, and infarct size at 3 to 5 days post-PCI. The key secondary safety end point is Impella CP-related major bleeding or major vascular complications within 30 days. Clinical follow-up is planned for 5 years. CONCLUSIONS: STEMI-DTU is a large-scale, prospective, randomized trial evaluating whether mechanical unloading of the LV by the Impella CP prior to primary PCI reduces infarct size and improves prognosis in patients with STEMI compared to primary PCI alone without LV unloading.
Assuntos
Insuficiência Cardíaca , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Estudos Prospectivos , Insuficiência Cardíaca/terapia , Resultado do TratamentoRESUMO
BACKGROUND: Contemporary practices for hemodynamically supported high-risk percutaneous coronary intervention have evolved over the last decade. This study sought to compare outcomes of the prospective, multicenter, PROTECT III study to historic patients treated with Impella in the PROTECT II randomized controlled trial. METHODS: Of 1,134 patients enrolled in PROTECT III from March 2017 to March 2020, 504 were "PROTECT II-like" (met eligibility for PROTECT II randomized controlled trial) and are referred to as PROTECT III for comparative analysis. Major adverse cardiac and cerebrovascular events (MACCE), comprising all-cause mortality, stroke/transient ischemic attack, myocardial infarction, and repeat revascularization, were compared at hospital discharge and 90 days. RESULTS: Compared with PROTECT II (N = 216), PROTECT III patients were less often Caucasian (77.1% vs 83.8%, P = .045), with less prior CABG (13.7% vs 39.4%; P < .001) and prior myocardial infarction (40.7% vs 69.3%; P < .001). More PROTECT III patients underwent rotational atherectomy (37.1% vs 14.8%, P < .001) and duration of support was longer (median 1.6 vs 1.3 hours; p<0.001), with greater improvement achieved in myocardial ischemia jeopardy scores (7.0±2.4 vs 4.4±2.9; P < .001) and SYNTAX scores (21.4±10.8 vs 15.7±9.5; P < .001). In-hospital bleeding requiring transfusion was significantly lower in PROTECT III (1.8% vs 9.3%; P < .001), as was procedural hypotension (2.2% vs 10.1%; P < .001) and cardiopulmonary resuscitation or ventricular arrhythmia (1.6% vs 6.9%; P < .001). At 90 days, MACCE was 15.1% and 21.9% in PROTECT III and PROTECT II, respectively (p=0.037). Following propensity score matching, Kaplan-Meier analysis showed improved 90-day MACCE rates in PROTECT III (10.4% vs 16.9%, P = .048). CONCLUSIONS: The PROTECT III study demonstrates improved completeness of revascularization, less bleeding, and improved 90-day clinical outcomes compared to PROTECT II for Impella-supported high-risk percutaneous coronary intervention among patients with severely depressed LVEF.
Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/terapia , Humanos , Estudos Prospectivos , Resultado do TratamentoRESUMO
While non-Hermitian systems are normally constructed through incoherent coupling to a larger environment, recent works have shown that under certain conditions coherent couplings can be used to similar effect. We show that this new paradigm enables the behavior associated with the PT-symmetric phase of a non-Hermitian subsystem to control the containing Hermitian system through the coherent couplings. This is achieved in parametric nonlinear wave mixing where simultaneous second harmonic generation replaces the role of loss to induce non-Hermitian behavior that persists through a full exchange of power within the Hermitian system. These findings suggest a new approach for the engineering of dynamics where energy recovery and sustainability are of importance that could be of significance for photonics and laser science.
RESUMO
OBJECTIVES: The EVOLVE 48 study evaluated the safety and effectiveness of the SYNERGY 48 mm stent for the treatment of long lesions. BACKGROUND: Clinical evidence supporting the use of very long stents during percutaneous coronary intervention (PCI) is limited. The bioabsorbable polymer SYNERGY stent has shown good long-term data in a broad population of patients undergoing PCI. METHODS: Patients with lesion length >34- ≤44 mm and reference vessel diameter (RVD) ≥2.5- ≤ 4.0 mm were enrolled in this prospective, multicenter, single-arm study. The primary endpoint was 12-month target lesion failure (TLF; composite of target lesion revascularization [TLR], target-vessel myocardial infarction [TV-MI], or cardiac death) compared to a prespecified performance goal (PG). RESULTS: A total of 100 patients with mean lesion length of 35.34 ± 7.15 mm (26 patients with lesion length > 40 mm) and mean RVD 2.72 ± 0.44 mm were enrolled. Moderate to severe calcification was present in 30% of the patients and 89% had pre-TIMI flow grade 3. The rates of technical and clinical procedural success were 100%. One-year TLF was observed in 4.1% patients compared to a prespecified PG of 19.5% (95% upper confidence bound = 9.1%; p < 0.0001). Cardiac death and TLR were each observed in one patient, and TV-MI in two patients treated with SYNERGY 48 mm stent. Between the 1-2-year timeframe, TV-MI occurred in one additional patient. None of the patients experienced a definite or probable stent thrombosis through 2 years. CONCLUSIONS: PCI of long coronary lesions with the 48 mm SYNERGY stent demonstrated good procedural and clinical outcomes through 2 years, supporting its clinical safety and efficacy.
Assuntos
Fármacos Cardiovasculares , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Fármacos Cardiovasculares/efeitos adversos , Everolimo/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Estudos Prospectivos , Desenho de Prótese , Sirolimo , Stents , Resultado do TratamentoRESUMO
BACKGROUND: Perforation is the most frequent complication of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) and is associated with adverse events including mortality. METHODS: Among 1,000 consecutive patients enrolled in 12 center prospective CTO PCI study (OPEN CTO), all perforations were reviewed by the angiographic core-lab. Eighty-nine patients (8.9%) with angiographic perforation were compared to 911 patients without perforation. We sought to describe the clinical and angiographic predictors of angiographic perforation during CTO PCI and develop a risk prediction model. RESULTS: Among eight clinically important candidate variables, independent risk factors for perforation included prior CABG (OR 2.0 [95% CI, 1.2-3.3], p < .01), occlusion length (OR 1.2 per 10 mm increase [95% CI, 1.1-1.3], p < .01), ejection fraction (OR 1.2 per 10% decrease [95% CI, 1.1-1.5], p < .01), age (OR 1.3 per 5 year increase [95%CI, 1.1-1.5], p < .01), and heavy calcification (OR 1.7 [95% CI, 1.0-2.7], p = .04). Three other potential candidate variables, glomerular filtration rate, proximal cap ambiguity, and target vessel, were not independently associated with perforation. The model was internally validated using bootstrapping methods. From the full model, a simplified perforation prediction score (OPEN-CLEAN score: CABG, Length [occlusion], EF < 50%, Age, CalcificatioN) was developed, which discriminated the risk of angiographic perforation well (c-statistics = 0.75) and demonstrated good calibration. CONCLUSION: This simple 5-variable prediction score may help CTO operators to risk-stratify patients for angiographic perforation using variables available prior to CTO PCI procedures.
Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Doença Crônica , Angiografia Coronária/efeitos adversos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Humanos , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Resultado do TratamentoRESUMO
OBJECTIVES: To describe hemodynamic efficacy and clinical outcomes of Impella percutaneous left ventricular assist device (pLVAD) in patients with cardiogenic shock (CS). BACKGROUND: Percutaneous LVADs are increasingly used in CS management. However, device-related outcomes and optimal utilization remain active areas of investigation. METHODS: All CS patients receiving pLVAD as mechanical circulatory support (MCS) between 2011 and 2017 were identified. Clinical characteristics and outcomes were analyzed. A multivariable logistic regression model was created to predict MCS escalation despite pLVAD. Outcomes were compared between early and late implantation. RESULTS: A total of 115 CS patients (mean age 63.6 ± 13.8 years; 69.6% male) receiving pLVAD as MCS were identified, the majority with CS secondary to acute myocardial infarction (AMI; 67.0%). Patients experienced significant cardiac output improvement (median 3.39 L/min to 3.90 L/min, p = .002) and pharmacological support reduction (median vasoactive-inotropic score [VIS] 25.4 to 16.4, p = .049). Placement of extracorporeal membrane oxygenation (ECMO) occurred in 48 (41.7%) of patients. Higher pre-pLVAD VIS was associated with subsequent MCS escalation in the entire cohort and AMI subgroup (OR 1.27 [95% CI 1.02-1.58], p = .034 and OR 1.72 [95% CI 1.04-2.86], p = .035, respectively). Complications were predominantly access site related (bleeding [9.6%], vascular injury [5.2%], and limb ischemia [2.6%]). In-hospital mortality was 57.4%, numerically greater survival was noted with earlier device implantation. CONCLUSIONS: Treatment with pLVAD for CS improved hemodynamic status but did not uniformly obviate MCS escalation. Mortality in CS remains high, though earlier device placement for appropriately selected patients may be beneficial.
Assuntos
Coração Auxiliar , Choque Cardiogênico , Centros Médicos Acadêmicos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do TratamentoRESUMO
BACKGROUND: Optical coherence tomography (OCT) is an adjunct to angiography-guided coronary stent placement. However, in the absence of dedicated, appropriately powered randomized controlled trials, the impact of OCT on clinical outcomes is unclear. OBJECTIVE: To conduct a systematic review and meta-analysis of all available studies comparing OCT-guided versus angiography-guided and intravascular ultrasound (IVUS)-guided coronary stent implantation. METHODS: MEDLINE and Cochrane Central were queried from their inception through July 2022 for all studies that sought to compare OCT-guided percutaneous coronary intervention (PCI) to angiography-guided and IVUS-guided PCI. The primary endpoint was minimal stent area (MSA) compared between modalities. Clinical endpoints of interest were all-cause and cardiovascular mortality, major adverse cardiovascular events (MACE), myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), and stent thrombosis (ST). Risk ratios (RRs) and mean differences (MDs) with their corresponding 95% confidence intervals (CIs) were pooled using a random-effects model. RESULTS: Thirteen studies (8 randomized control trials and 5 observational studies) enrolling 6312 participants were included. OCT was associated with a strong trend toward increased MSA compared to angiography (MD = 0.36, p = 0.06). OCT-guided PCI was also associated with a reduction in the incidence of all-cause mortality [RR = 0.59, 95% CI (0.35, 0.97), p = 0.04] and cardiovascular mortality [RR = 0.41, 95% CI (0.21, 0.80), p = 0.009] compared with angiography-guided PCI. Point estimates favored OCT relative to angiography in MACE [RR = 0.75, 95% CI (0.47, 1.20), p = 0.22] and MI [RR = 0.75, 95% CI (0.53, 1.07), p = 0.12]. No differences were detected in ST [RR = 0.71, 95% CI (0.21, 2.44), p = 0.58], TLR [RR = 0.71, 95% CI (0.17, 3.05), p = 0.65], or TVR rates [RR = 0.89, 95% CI (0.46, 1.73), p = 0.73]. Compared with IVUS guidance, OCT guidance was associated with a nonsignificant reduction in the MSA (MD = -0.16, p = 0.27). The rates of all-cause and cardiovascular mortality, MACE, MI, TLR, TVR, or ST were similar between OCT-guided and IVUS-guided PCI. CONCLUSIONS: OCT-guided PCI was associated with reduced all-cause and cardiovascular mortality compared to angiography-guided PCI. These results should be considered hypothesis generating as the mechanisms for the improved outcomes were unclear as no differences were detected in the rates of TLR, TVR, or ST. OCT- and IVUS-guided PCI resulted in similar post-PCI outcomes.
Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Angiografia Coronária/efeitos adversos , Tomografia de Coerência Óptica/efeitos adversos , Ultrassonografia de Intervenção/efeitos adversos , Ultrassonografia de Intervenção/métodos , Resultado do Tratamento , Stents/efeitos adversos , Infarto do Miocárdio/etiologia , Trombose/etiologia , Ensaios Clínicos Controlados Aleatórios como AssuntoRESUMO
OBJECTIVES: The purpose of the current study was to use intravascular ultrasound (IVUS) to clarify anatomical and morphological lesion characteristics of uncrossable lesions. BACKGROUND: Uncrossable lesions are not always severely calcified. The prevalence of uncrossable lesions that are nonseverely calcified as well as other mechanisms for uncrossability has not been well clarified. METHODS: A total of 252 de novo uncrossable lesions in native coronary arteries that underwent either rotational or orbital atherectomy due to inability of any balloon to cross the lesion and 38 lesions with severe calcium in which IVUS crossed preatherectomy were included. Severe calcium is defined as maximum arc of calcium ≥270°. RESULTS: Severe calcification was absent in 16% of uncrossable lesions, 83% of which had a significant vessel bend. Compared with crossable lesions with severe calcium, uncrossable lesions with severe calcium more often had a bend in the vessel (71% vs. 21%, p < 0.001) and a longer length of continuous severe calcium (median length of calcium ≥270° 3.8 mm vs. 1.9 mm, p = 0.001). Other than severe calcium (especially long continuous calcium) or a bend in the vessel, anatomical factors associated with uncrossabilty were aorto-ostial lesion location and small vessels. CONCLUSIONS: Uncrossable lesions are not always severely calcified. The interaction of lesion morphology (continuous long and large arcs of calcium) and vessel geometry (bend in the vessel or ostial lesion location) affect lesion crossability.
Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Calcificação Vascular , Aterectomia Coronária/efeitos adversos , Cálcio , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Resultado do Tratamento , Ultrassonografia de Intervenção , Calcificação Vascular/diagnóstico por imagemRESUMO
AIMS: The REFLECT I trial investigated the safety and effectiveness of the TriGuard™ HDH (TG) cerebral embolic deflection device in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: This prospective, multicentre, single-blind, 2:1 randomized (TG vs. no TG) study aimed to enrol up to 375 patients, including up to 90 roll-in patients. The primary combined safety endpoint (VARC-2 defined early safety) at 30 days was compared with a performance goal. The primary efficacy endpoint was a hierarchical composite of (i) all-cause mortality or any stroke at 30 days, (ii) National Institutes of Health Stroke Scale (NIHSS) worsening at 2-5 days or Montreal Cognitive Assessment worsening at 30 days, and (iii) total volume of cerebral ischaemic lesions detected by diffusion-weighted magnetic resonance imaging at 2-5 days. Cumulative scores were compared between treatment groups using the Finkelstein-Schoenfeld method. A total of 258 of the planned, 375 patients (68.8%) were enrolled (54 roll-in and 204 randomized). The primary safety outcome was met compared with the performance goal (21.8% vs. 35%, P < 0.0001). The primary hierarchical efficacy endpoint was not met (mean efficacy score, higher is better: -5.3 ± 99.8 TG vs. 11.8 ± 96.4 control, P = 0.31). Covert central nervous system injury was numerically lower with TG both in-hospital (46.1% vs. 60.3%, P = 0.0698) and at 5 days (61.7 vs. 76.2%, P = 0.054) compared with controls. CONCLUSION: REFLECT I demonstrated that TG cerebral protection during TAVR was safe in comparison with historical TAVR data but did not meet the predefined effectiveness endpoint compared with unprotected TAVR controls.
Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
We introduce a concept for efficient optical parametric amplification (OPA) based on simultaneously phase-matched idler second harmonic generation (SHG), which together exhibits the dynamical behavior of parametric amplification but with damped conversion-back-conversion cycles. This enables amplification efficiency exceeding that of conventional OPA by several-fold for femtosecond and picosecond signal pulses with bell-shaped intensity profiles by allowing a near-uniform spatiotemporal depletion of the pump wave. We develop a Duffing oscillator model that unifies the description of conventional OPA and amplification accompanied by idler photon displacement by either linear absorption or SHG. A spatiotemporal analysis of devices based on birefringent or superlattice quasi-phase matching in common bulk media predicts energy conversion up to 55%.
RESUMO
The conversion efficiency and phase matching bandwidth of ultrafast optical parametric amplification (OPA) are constrained by the dispersion and nonlinear coefficient of the employed crystal as well as pulse shaping effects. In our work we show that an enhancement cavity resonant with the pump seeded at the full repetition rate of the pump laser can automatically reshape the small-signal gain in optical parametric chirped-pulse amplification (OPCPA) to achieve close-to-optimal operation. This new method termed cavity-enhanced OPCPA or C-OPCPA significantly increases both the gain bandwidth and the conversion efficiency, in addition to boosting gain for high-repetition-rate amplification. The goal in C-OPCPA is to arrive at a condition of impedance matching at all temporal coordinates, such that, in the absence of linear losses, all the incident pump power is dissipated in the nonlinear loss element, i.e., converted to signal and idler. The use of a low finesse enhancement cavity resonant with a low average power (<1W) and a high repetition rate (78MHz) pump source is shown to achieve more than 50% conversion efficiency into signal and idler from the coupled pump in an optical parametric process, whereas an equivalent amount of pump power in a single-pass configuration leads to negligible conversion. Additionally, the gain bandwidth is extended by a factor of 3-4 beyond the phase-matching limit. Our empirical observations are corroborated by a numerical analysis of depletion optimizing the single-pass case, which assesses the underlying impedance matching that is responsible for the observed performance improvements.
RESUMO
BACKGROUND: The effect of body mass index (BMI) on the procedural outcomes and health status (HS) change after chronic total occlusion (CTO) percutaneous coronary intervention (PCI) is largely unknown. METHODS: Thousand consecutive patients enrolled in a 12-center prospective CTO PCI study (Outcomes, Patient Health Status, and Efficiency in Chronic Total Occlusion Hybrid Procedures [OPEN-CTO]) were categorized into three groups by baseline BMI (obese ≥30, overweight 25-30, and normal 18.5-25), after excluding seven patients with BMI <18.5. Baseline and follow-up HS at 1 year were quantified using the Seattle Angina Questionnaire, Rose Dyspnea Score, and Personal Health Questionnaire-8 (PHQ-8). Hierarchical, multivariable logistic, and repeated measures linear regression models were used to assess procedural success, major adverse cardiovascular and cerebrovascular events (MACCE), and HS outcomes, as appropriate. RESULTS: The obese and overweight were 47.6% and 37.4%, respectively. While procedure time and contrast dose were similar among the groups, total radiation dose (mGy) was higher with increased BMI (3,019 ± 2,027, 2,267 ± 1,714, 1,642 ± 1,223, p < .01). Procedural success rates, as well as MACCE rates, were similar among the three groups (obese 83.1%, overweight 79.8%, normal 81.9%, p = .47 and 5.1, 8.4, and 8.7%, p = .11). These rates remained similar after adjustment for baseline characteristics. The HS improvement from baseline to 12 months after adjustment was similar in obese and overweight patients compared to normal weight patients. CONCLUSIONS: CTO PCI in obese and overweight patients can be performed with similar success and complication rates. Obese and overweight patients derive similar HS benefit from CTO PCI compared to normal weight patients.