Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Nanotechnology ; 27(49): 495604, 2016 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-27834309

RESUMO

Ti-Ta alloys are attractive materials for applications in actuators as well as biomedical implants. When fabricated as thin films, these alloys can potentially be employed as microactuators, components for micro-implantable devices and coatings on surgical implants. In this study, Ti100-x Ta x (x = 21, 30) nanocolumnar thin films are fabricated by glancing angle deposition (GLAD) at room temperature using Ti73Ta27 and Ta sputter targets. Crystal structure, morphology and microstructure of the nanostructured thin films are systematically investigated by XRD, SEM and TEM, respectively. Nanocolumns of ∼150-160 nm in width are oriented perpendicular to the substrate for both Ti79Ta21 and Ti70Ta30 compositions. The disordered α″ martensite phase with orthorhombic structure is formed in room temperature as-deposited thin films. The columns are found to be elongated small single crystals which are aligned perpendicular to the [Formula: see text] and [Formula: see text] planes of α″ martensite, indicating that the films' growth orientation is mainly dominated by these crystallographic planes. Laser pre-patterned substrates are utilized to obtain periodic nanocolumnar arrays. The differences in seed pattern, and inter-seed distances lead to growth of multi-level porous nanostructures. Using a unique sputter deposition geometry consisting of Ti73Ta27 and Ta sputter sources, a nanocolumnar Ti-Ta materials library was fabricated on a static substrate by a co-deposition process (combinatorial-GLAD approach). In this library, a composition spread developed between Ti72.8Ta27.2 and Ti64.4Ta35.6, as confirmed by high-throughput EDX analysis. The morphology over the materials library varies from well-isolated nanocolumns to fan-like nanocolumnar structures. The influence of two sputter sources is investigated by studying the resulting column angle on the materials library. The presented nanostructuring methods including the use of the GLAD technique along with pre-patterning and a combinatorial materials library fabrication strategy offer a promising technological approach for investigating Ti-Ta thin films for a range of applications. The proposed approaches can be similarly implemented for other materials systems which can benefit from the formation of a nanocolumnar morphology.

2.
Nanotechnology ; 25(19): 195101, 2014 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-24763247

RESUMO

The aim of this study was to reproduce the physico-mechanical antibacterial effect of the nanocolumnar cicada wing surface for metallic biomaterials by fabrication of titanium (Ti) nanocolumnar surfaces using glancing angle sputter deposition (GLAD). Nanocolumnar Ti thin films were fabricated by GLAD on silicon substrates. S. aureus as well as E. coli were incubated with nanostructured or reference dense Ti thin film test samples for one or three hours at 37 °C. Bacterial adherence, morphology, and viability were analyzed by fluorescence staining and scanning electron microscopy and compared to human mesenchymal stem cells (hMSCs).Bacterial adherence was not significantly different after short (1 h) incubation on the dense or the nanostructured Ti surface. In contrast to S. aureus the viability of E. coli was significantly decreased after 3 h on the nanostructured film compared to the dense film and was accompanied by an irregular morphology and a cell wall deformation. Cell adherence, spreading and viability of hMSCs were not altered on the nanostructured surface. The results show that the selective antibacterial effect of the cicada wing could be transferred to a nanostructured metallic biomaterial by mimicking the natural nanocolumnar topography.


Assuntos
Antibacterianos/farmacologia , Nanoestruturas , Titânio/farmacologia , Animais , Aderência Bacteriana/efeitos dos fármacos , Escherichia coli/citologia , Escherichia coli/efeitos dos fármacos , Hemípteros , Humanos , Viabilidade Microbiana/efeitos dos fármacos , Nanoestruturas/ultraestrutura , Staphylococcus aureus/citologia , Staphylococcus aureus/efeitos dos fármacos , Propriedades de Superfície
3.
ACS Comb Sci ; 20(3): 137-150, 2018 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-29356502

RESUMO

Ti-Ta thin films exhibit properties that are of interest for applications as microactuators and as biomedical implants. A Ti-Ta thin film materials library was deposited at T = 25 °C by magnetron sputtering employing the combinatorial approach, which led to a compositional range of Ti87Ta13 to Ti14Ta86. Subsequent high-throughput characterization methods permitted a quick and comprehensive study of the crystallographic, microstructural, and morphological properties, which strongly depend on the chemical composition. SEM investigation revealed a columnar morphology having pyramidal, sharp tips with coarser columns in the Ti-rich and finer columns in the Ta-rich region. By grazing incidence X-ray diffraction four phases were identified, from Ta-lean to Ta-rich: ω phase, α″ martensite, ß phase, and a tetragonal Ta-rich phase (Ta(tetr)). The crystal structure and microstructure were analyzed by Rietveld refinement and clear trends could be determined as a function of Ta-content. The lattice correspondences between ß as the parent phase and α″ and ω as derivative phases were expressed in matrix form. The ß â‡Œ α″ phase transition shows a discontinuity at the composition where the martensitic transformation temperatures fall below room temperature (between 34 and 38 at. % Ta) rendering it first order and confirming its martensitic nature. A short study of the α″ martensite employing the Landau theory is included for a mathematical quantification of the spontaneous lattice strain at room temperature (ϵ̂max = 22.4(6) % for pure Ti). Martensitic properties of Ti-Ta are beneficial for the development of high-temperature actuators with actuation response at transformation temperatures higher than 100 °C.


Assuntos
Ligas/química , Técnicas de Química Combinatória/métodos , Bibliotecas de Moléculas Pequenas/química , Tantálio/química , Titânio/química , Materiais Biocompatíveis/química , Cristalografia/métodos , Ligas Dentárias/química , Teste de Materiais/métodos , Transição de Fase , Relação Estrutura-Atividade , Temperatura , Difração de Raios X/métodos
4.
Mater Sci Eng C Mater Biol Appl ; 74: 536-541, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28254328

RESUMO

Five different Ag dots arrays (16 to 400dots/mm2) were fabricated on a continuous platinum, palladium, or iridium thin film and for comparison also on titanium film by sputter deposition and photolithographic patterning. To analyze the antibacterial activity of these microstructured films Staphylococcus aureus (S. aureus) were placed onto the array surfaces and cultivated overnight. To analyze the viability of planktonic as well as surface adherent bacteria, the applied bacterial fluid was subsequently aspirated, plated on blood agar plates and adherent bacteria were detected by fluorescence microscopy. A particular antibacterial effect towards S. aureus was induced by Ag dot arrays on each of the platinum group thin film (sacrificial anode system for Ag) in contrast to Ag dot arrays fabricated on the Ti thin films (non-sacrificial anode system for Ag). Among platinum group elements the Ir-Ag system exerted the highest antibacterial activity which was accompanied by most advanced dissolution of the Ag dots and Ag ion release compared to Ag dots on Pt or Pd.


Assuntos
Antibacterianos/química , Irídio/química , Paládio/química , Platina/química , Prata/química , Antibacterianos/farmacologia , Aderência Bacteriana/efeitos dos fármacos , Eletrodos , Microscopia Eletrônica de Varredura , Staphylococcus aureus/efeitos dos fármacos , Propriedades de Superfície
5.
J Mech Behav Biomed Mater ; 59: 337-352, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26897095

RESUMO

Release of Ni(1+) ions from NiTi alloy into tissue environment, biological response on the surface of NiTi and the allergic reaction of atopic people towards Ni are challengeable issues for biomedical application. In this study, composite coatings of hydroxyapatite-silicon multi walled carbon nano-tubes with 20wt% Silicon and 1wt% multi walled carbon nano-tubes of HA were deposited on a NiTi substrate using electrophoretic methods. The SEM images of coated samples exhibit a continuous and compact morphology for hydroxyapatite-silicon and hydroxyapatite-silicon-multi walled carbon nano-tubes coatings. Nano-indentation analysis on different locations of coatings represents the highest elastic modulus (45.8GPa) for HA-Si-MWCNTs which is between the elastic modulus of NiTi substrate (66.5GPa) and bone tissue (≈30GPa). This results in decrease of stress gradient on coating-substrate-bone interfaces during performance. The results of nano-scratch analysis show the highest critical distance of delamination (2.5mm) and normal load before failure (837mN) as well as highest critical contact pressure for hydroxyapatite-silicon-multi walled carbon nano-tubes coating. The cell culture results show that human mesenchymal stem cells are able to adhere and proliferate on the pure hydroxyapatite and composite coatings. The presence of both silicon and multi walled carbon nano-tubes (CS3) in the hydroxyapatite coating induce more adherence of viable human mesenchymal stem cells in contrast to the HA coated samples with only silicon (CS2). These results make hydroxyapatite-silicon-multi walled carbon nano-tubes a promising composite coating for future bone implant application.


Assuntos
Materiais Revestidos Biocompatíveis/química , Durapatita/química , Nanotubos de Carbono/química , Silício/química , Ligas , Adesão Celular , Proliferação de Células , Células Cultivadas , Humanos , Teste de Materiais , Células-Tronco Mesenquimais/citologia , Níquel , Propriedades de Superfície , Titânio
6.
Mater Sci Eng C Mater Biol Appl ; 46: 276-80, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25491988

RESUMO

Ten different Ag dot arrays (16 to 625 microstructured dots per square mm) were fabricated on a continuous Au thin film and for comparison also on Ti film by sputter deposition and photolithographic patterning. To analyze the antibacterial activity of these microstructured films Escherichia coli and Staphylococcus aureus were placed onto the array surfaces and cultivated overnight. To analyze the viability of planktonic as well as surface adherent bacteria, the applied bacterial fluid was subsequently aspirated, plated on blood agar plates and adherent bacteria were detected by fluorescence microscopy. A particular antibacterial effect towards both bacterial strains was induced by Ag dot arrays on fabricated Au thin film (sacrificial anode system for Ag), due to the release of Ag ions from dissolution of Ag dots in contrast to Ag dot arrays fabricated on the Ti thin films (non-sacrificial anode system for Ag) which remained intact to the original dot shape. The required number of Ag dots on gold film to achieve complete bactericidal effects for both bacterial strains was seven times lower than that observed with Ag dot arrays on Ti film.


Assuntos
Antibacterianos/farmacologia , Eletrodos , Ouro/farmacologia , Prata/farmacologia , Antibacterianos/química , Células Cultivadas , Ouro/química , Humanos , Prata/química
7.
ACS Comb Sci ; 15(8): 401-9, 2013 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-23697925

RESUMO

A Lia(NixMnyCoz)Or cathode materials library was fabricated by combinatorial magnetron sputtering. The compositional analysis of the library was performed by a new high-throughput approach for Li-content measurement in thin films, which combines automated energy-dispersive X-ray spectroscopy, Deuteron-induced gamma emission, and Rutherford backscattering measurements. Furthermore, combining this approach with thickness measurements allows the mapping of density values of samples from the materials library. By correlating the obtained compositional data with structural data from high-throughput X-ray diffraction measurements, those compositions which show a layered (R3̅m) structure and are therefore most interesting for Li-battery applications (for cathode (positive) electrodes) can be rapidly identified. This structure was identified as being most pronounced in the compositions Li0.6(Ni0.16Mn0.35Co0.48)O2, Li0.7(Ni0.10Mn0.37Co0.51)O2, Li0.6(Ni0.23Mn0.33Co0.43)O2, Li0.3(Ni0.65Mn0.08Co0.26)O2, Li0.3(Ni0.63Mn0.08Co0.29)O2, Li0.4(Ni0.56Mn0.09Co0.34)O2, Li0.5(Ni0.45Mn0.13Co0.42)O2, and Li0.6(Ni0.34Mn0.14Co0.52)O2.


Assuntos
Fontes de Energia Elétrica , Ensaios de Triagem em Larga Escala , Compostos de Lítio/química , Estrutura Molecular , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA