Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 193
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 389(16): 1477-1487, 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37634149

RESUMO

BACKGROUND: Imaging-guided percutaneous coronary intervention (PCI) is associated with better clinical outcomes than angiography-guided PCI. Whether routine optical coherence tomography (OCT) guidance in PCI of lesions involving coronary-artery branch points (bifurcations) improves clinical outcomes as compared with angiographic guidance is uncertain. METHODS: We conducted a multicenter, randomized, open-label trial at 38 centers in Europe. Patients with a clinical indication for PCI and a complex bifurcation lesion identified by means of coronary angiography were randomly assigned in a 1:1 ratio to OCT-guided PCI or angiography-guided PCI. The primary end point was a composite of major adverse cardiac events (MACE), defined as death from a cardiac cause, target-lesion myocardial infarction, or ischemia-driven target-lesion revascularization at a median follow-up of 2 years. RESULTS: We assigned 1201 patients to OCT-guided PCI (600 patients) or angiography-guided PCI (601 patients). A total of 111 patients (18.5%) in the OCT-guided PCI group and 116 (19.3%) in the angiography-guided PCI group had a bifurcation lesion involving the left main coronary artery. At 2 years, a primary end-point event had occurred in 59 patients (10.1%) in the OCT-guided PCI group and in 83 patients (14.1%) in the angiography-guided PCI group (hazard ratio, 0.70; 95% confidence interval, 0.50 to 0.98; P = 0.035). Procedure-related complications occurred in 41 patients (6.8%) in the OCT-guided PCI group and 34 patients (5.7%) in the angiography-guided PCI group. CONCLUSIONS: Among patients with complex coronary-artery bifurcation lesions, OCT-guided PCI was associated with a lower incidence of MACE at 2 years than angiography-guided PCI. (Funded by Abbott Vascular and others; OCTOBER ClinicalTrials.gov number, NCT03171311.).


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Tomografia de Coerência Óptica , Humanos , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Tomografia de Coerência Óptica/efeitos adversos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Europa (Continente)
2.
N Engl J Med ; 382(13): 1208-1218, 2020 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-32050061

RESUMO

BACKGROUND: Polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited. METHODS: In an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority. RESULTS: A total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority). CONCLUSIONS: Among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.).


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Imunossupressores/administração & dosagem , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/uso terapêutico , Polímeros , Sirolimo/análogos & derivados , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Quimioterapia Combinada , Stents Farmacológicos/efeitos adversos , Cardiopatias/mortalidade , Hemorragia/induzido quimicamente , Humanos , Estimativa de Kaplan-Meier , Inibidores da Agregação Plaquetária/efeitos adversos , Desenho de Prótese , Método Simples-Cego , Sirolimo/administração & dosagem
3.
Catheter Cardiovasc Interv ; 102(7): 1401-1405, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37694603

RESUMO

Valve-in-valve TAVI to treat failing surgical aortic valves (SAVs) is increasingly performed, and commissural alignment is a key technical aspect in such procedures. Surgeons optimize valve alignment, accounting for potential coronary eccentricity and achieving a patient-specific optimized commissural orientation, representing the ideal target for TAVI alignment. Therefore, here we present a dedicated stepwise valve-in-valve implantation technique using the ACURATE neo2. In a specific SAV postoverlap view, isolating one surgical post to the right of the screen representing the target for alignment, rotational orientation of the TAVI commissures, matching the SAV orientation, is achieved and verified before implantation. This technique has been tested in a patient-specific three-dimensionally-printed aortic root anatomy, attached to a pulsatile flow simulator, allowing for native-like simulation of coronary cannulations under fluoroscopy, and enabling detailed assessment with fluoroscopic as well as direct videographic visualization. Furthermore, the technique is exemplified by providing an educational clinical case example.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
4.
Catheter Cardiovasc Interv ; 101(3): 553-562, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36709485

RESUMO

BACKGROUND: Techniques for provisional and dual-stent left main bifurcation stenting require optimization. AIM: To identify technical variables influencing procedural outcomes and periprocedural myocardial infarction following left main bifurcation intervention. METHODS: Procedural and outcome data were analyzed in 438 patients from the per-protocol cohort of the European Bifurcation Club Left Main Trial (EBC MAIN). These patients were randomized to the provisional strategy or a compatible dual-stent extension (T, T-and-protrude, or culotte). RESULTS: Mean age was 71 years and 37.4% presented with an acute coronary syndrome. Transient reduction of side vessel thrombolysis in myocardial infarction flow occurred after initial stent placement in 5% of procedures but was not associated with periprocedural myocardial infarction. Failure to rewire a jailed vessel during any strategy was more common when jailed wires were not used (9.5% vs. 2.5%, odds ratio [OR]: 6.4, p = 0.002). In the provisional cohort, the use of the proximal optimization technique was associated with less subsequent side vessel intervention (23.3% vs. 41.9%, OR: 0.4, p = 0.048). Side vessel stenting was predominantly required for dissection, which occurred more often following side vessel preparation (15.3% vs. 4.4%, OR: 3.1, p = 0.040). Exclusive use of noncompliant balloons for kissing balloon inflation was associated with reduced need for side vessel intervention in provisional cases (20.5% vs. 38.5%, OR: 0.4, p = 0.013), and a reduced risk of periprocedural myocardial infarction across all strategies (2.9% vs. 7.7%, OR: 0.2, p = 0.020). CONCLUSION: When performing provisional or compatible dual-stent left main bifurcation intervention, jailed wire use is associated with successful jailed vessel rewiring. Side vessel preparation in provisional patients is linked to increased side vessel dissection requiring stenting. Use of the proximal optimization technique may reduce the need for additional side vessel intervention, and noncompliant balloon use for kissing balloon inflation is associated with a reduction in both side vessel stenting and periprocedural myocardial infarction. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT02497014.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Humanos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Resultado do Tratamento , Stents , Infarto do Miocárdio/etiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Angiografia Coronária
5.
Catheter Cardiovasc Interv ; 99(4): 1172-1180, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34792842

RESUMO

BACKGROUND: The ACURATE neo™ is a novel, second-generation self-expanding supra-annular transcatheter heart valve (THV). The objective of this multi-centre registry is to assess the safety, clinical utility, and impact of 'learning-curve-experience' (LCE) on transcatheter aortic valve replacement outcomes in the United Kingdom (UK) and Ireland. METHODS: We prospectively collected data from seven ACURATE neo™ THV implanting centres (n = 484) between February 2016 and November 2020. We compared mortality rates and outcomes in the LCE group (n = 120) compared to next successive 120 cases. RESULTS: The mean age of the cohort was 81.9(SD: 6.1) years and the majority were in the moderate risk category (EuroSCORE-II):3.3(SD: 3). The 97.5% of cases were performed under local anesthetic. The valve was successfully deployed in 98.8% of cases. The survival rate at 30 days was 97.9%. The incidence of stroke was 2.5%. Life threatening bleeding occurred in 0.6% of cases and vascular access complications occurred in 21 (4.3%) patients. Implantation-related conduction abnormalities occurred in 8.3% but only 5.6% required a PPM. The successful valve deployment occurred in 96% of the patients in the LCE group compared to 100% in the other group (p = 0.04; OR-2[CI 1.7-2.3]). The mortality rates at 30 days (1.7% vs. 1.7%) and 1 year (1.9% vs. 2.7%) were comparable between the two groups. CONCLUSIONS: This study represents the largest published UK and Ireland real-world experience of the ACURATE neo™ valve. The procedural success rates and safety outcomes were excellent and endorse its utility in clinical practice. The LCE appears to have an impact on the successful valve deployment but without translating into short-term or long-term outcomes.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Irlanda , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Reino Unido
6.
Am Heart J ; 232: 23-38, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33160946

RESUMO

BACKGROUND: The recent approval of transcatheter aortic valve replacement (TAVR) in patients with low operative risk has paved the way for the introduction of novel and potentially improved technologies. The safety and efficacy of these novel technologies should be investigated in randomized control trials against the contemporary TAVR devices. The objective of the LANDMARK trial is to compare the balloon-expandable Myval transcatheter heart valve (THV) series with contemporary THV (SAPIEN THV and Evolut THV series) series in patients with severe symptomatic native aortic stenosis. METHODS/DESIGN: The LANDMARK trial (ClinicalTrials.govNCT04275726, EudraCT number 2020-000,137-40) is a prospective, randomized, multinational, multicenter, open-label, and noninferiority trial of approximately 768 patients treated with TAVR via the transfemoral approach. Patients will be allocated in a 1:1 randomization to Myval THV series (n = 384) or to contemporary THV (n = 384) (either of SAPIEN THV or Evolut THV series). The primary combined safety and efficacy endpoint is a composite of all-cause mortality, all stroke (disabling and nondisabling), bleeding (life-threatening or disabling), acute kidney injury (stage 2 or 3), major vascular complications, prosthetic valve regurgitation (moderate or severe), and conduction system disturbances (requiring new permanent pacemaker implantation), according to the Valve Academic Research Consortium-2 criteria at 30-day follow-up. All patients will have follow-up to 10 years following TAVR. SUMMARY: The LANDMARK trial is the first randomized head-to-head trial comparing Myval THV series to commercially available THVs in patients indicated for TAVR. We review prior data on head-to-head comparisons of TAVR devices and describe the rationale and design of the LANDMARK trial.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/epidemiologia , Insuficiência da Valva Aórtica/epidemiologia , Doença do Sistema de Condução Cardíaco/epidemiologia , Doença do Sistema de Condução Cardíaco/terapia , Estudos de Equivalência como Asunto , Humanos , Mortalidade , Marca-Passo Artificial , Hemorragia Pós-Operatória/epidemiologia , Desenho de Prótese , Falha de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Índice de Gravidade de Doença , Acidente Vascular Cerebral/epidemiologia
7.
Catheter Cardiovasc Interv ; 98(4): 756-764, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33991385

RESUMO

OBJECTIVES: To evaluate outcome and its predictors of bioprosthetic valve fracture (BVF) in patients undergoing valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). BACKGROUND: BVF is feasible and reduces transvalvular gradients in VIV-TAVR-procedures, but follow-up-data and information on factors influencing the outcome are missing. METHODS: The 81 cases of BVF-VIV-TAVR were collected from 14 international centers. RESULTS: Predominantly transcatheter heart valve (THV) was implanted first, followed by BVF. VARC-2 defined device success was 93%, most failures were attributed to residual high gradients. Mean gradients decreased from 37 ± 13 mmHg to 10.8 ± 5.9 mmHg (p < 0.001). BVF reduced the gradient by 16 mmHg. During follow-up (FU, 281 ± 164 days) mean gradient remained stable (10.8 ± 5.9 mmHg at discharge, 12.4 ± 6.3 mmHg at FU, p = ns). In-hospital major adverse events occurred in 3.7%. Event-free survival at 276 ± 237.6 days was 95.4%. The linear mixed model identified balloon-expandable valves (BEV), Mitroflow surgical valve, stenotic surgical bioprostheses and balloon only 1 mm larger than the true internal diameter of the surgical valve as predictors for higher gradients. CONCLUSIONS: BVF is safe and can significantly reduce gradients, which remain stable at FU. BEV, Mitroflow surgical valve, stenotic bioprostheses and balloon larger than the true internal diameter of the surgical valve of only 1 mm are predictors for higher final gradients.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Seguimentos , Hemodinâmica , Humanos , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Eur Radiol ; 31(8): 6220-6229, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34156556

RESUMO

OBJECTIVES: We sought to identify the impact of transcatheter aortic valve implantation (TAVI) on changes of fractional flow reserve computed tomography (FFRCT) values and the associated clinical impact. METHODS: A retrospective analysis was done with CT obtained pre-TAVI, prior to hospital discharge and at 1-year follow-up, which provided imaging sources for the calculation of FFRCT values based on an online platform. RESULTS: A total of 190 patients were enrolled. Patients with pre-procedural FFRCT value > 0.80 (i.e., negative) and ≤ 0.80 (i.e., positive) demonstrated a significantly opposite change in the value after TAVI (0.8798 vs. 0.8718, p < 0.001 and 0.7634 vs. 0.8222, p < 0.001, respectively). The history of coronary artery disease (CAD) was identified as an independent predictor for FFRCT changing from negative to positive after TAVI (odds ratio [OR] 2.927, 95% confidence interval [CI] 1.130-7.587, p = 0.027), with lesions more severely stenosed (OR 1.039, 95% CI 1.003-1.076, p = 0.034) and in left anterior descending coronary artery (LAD) (OR 3.939, 95% CI 1.060-14.637, p = 0.041) being prone to change. CONCLUSIONS: TAVI directly brings improvement in FFRCT values in patients with compromised coronary flow. Patients with a history of CAD, especially with lesions more severely stenosed and in LAD, were under risk of FFRCT changing from negative to positive after TAVI. KEY POINTS: •The effect of TAVI on coronary hemodynamics might be influenced by different ischemic severity and coronary territories reflected by FFRCT values. •As different FFRCT variations did not impact outcomes of TAVI patients, AS, but not coronary issues, may be the primary problem to affect, which needs further validation.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Substituição da Valva Aórtica Transcateter , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Hemodinâmica , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
9.
J Stroke Cerebrovasc Dis ; 30(9): 105927, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34252826

RESUMO

OBJECTIVES: An assessment of the comparative incidence of fatal or disabling stroke may influence choice of intervention for patients with severe aortic stenosis. We explored whether transcatheter aortic valve implantation (TAVI) is associated with a lower incidence of fatal or disabling stroke, compared to surgical aortic valve replacement (SAVR). MATERIALS & METHODS: We classified stroke into two categories; fatal or disabling, or non-disabling, and completed meta-analyses for each. We explored randomised controlled trials to assess the effect publication year, predicted operative risk, and route of TAVI access. RESULTS: There was no difference between treatment groups per 100 person years of follow up for disabling or non-disabling stroke outcomes. In a stratified analysis by year of publication, there was a lower rate of fatal or disabling stroke with TAVI in trials published after 2015, compared to those published in 2015 or before (p-interaction = 0.01 at 30 days). Higher proportions of transfemoral route access (>90%), more common in recent trials, were associated with a lower rate of fatal or disabling stroke (p-interaction = 0.03 at 30 days). Lower average surgical risk scores were associated with lower rates of fatal or disabling stroke (p = 0.02 at 30 days). CONCLUSION: We found that treatment of aortic stenosis with TAVI compared with SAVR was not associated with an overall reduced risk in fatal or disabling stroke. Subgroup analyses suggested a lower risk of fatal or disabling stroke with TAVI in situations which reflect contemporary practice.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Avaliação da Deficiência , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Incidência , Masculino , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
10.
Circulation ; 140(3): 240-261, 2019 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-31116032

RESUMO

Identification and management of patients at high bleeding risk undergoing percutaneous coronary intervention are of major importance, but a lack of standardization in defining this population limits trial design, data interpretation, and clinical decision-making. The Academic Research Consortium for High Bleeding Risk (ARC-HBR) is a collaboration among leading research organizations, regulatory authorities, and physician-scientists from the United States, Asia, and Europe focusing on percutaneous coronary intervention-related bleeding. Two meetings of the 31-member consortium were held in Washington, DC, in April 2018 and in Paris, France, in October 2018. These meetings were organized by the Cardiovascular European Research Center on behalf of the ARC-HBR group and included representatives of the US Food and Drug Administration and the Japanese Pharmaceuticals and Medical Devices Agency, as well as observers from the pharmaceutical and medical device industries. A consensus definition of patients at high bleeding risk was developed that was based on review of the available evidence. The definition is intended to provide consistency in defining this population for clinical trials and to complement clinical decision-making and regulatory review. The proposed ARC-HBR consensus document represents the first pragmatic approach to a consistent definition of high bleeding risk in clinical trials evaluating the safety and effectiveness of devices and drug regimens for patients undergoing percutaneous coronary intervention.


Assuntos
Congressos como Assunto , Consenso , Hemorragia/diagnóstico , Hemorragia/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Congressos como Assunto/tendências , District of Columbia , Hemorragia/prevenção & controle , Humanos , Paris , Intervenção Coronária Percutânea/tendências , Medição de Risco/métodos
11.
Catheter Cardiovasc Interv ; 95(2): 332-338, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31020788

RESUMO

OBJECTIVE: This study reports the 1-year clinical outcomes of the VitaFlow™ transcatheter aortic valve system in the treatment of severe aortic stenosis. BACKGROUND: The VitaFlow™ system (MicroPort®, Shanghai, China) was developed as a novel transcatheter aortic valve replacement system to mitigate or circumvent some of the challenges associated with heavily calcified valves and bicuspid valves. METHODS: From September 2014 to November 2017, a prospective, multicenter, single arm study was conducted in 11 centers in China. The primary end point was all cause mortality at 12 months. RESULTS: One hundred and ten symptomatic aortic stenosis patients (60 men, 50 women; mean age 77.73 ± 4.78 years) at prohibitive or high risk for surgery were enrolled. Mean society of thoracic surgeons score was 8.84 ± 5.58%. All-cause mortality was 2.7% at 1-year. Major stroke, major vascular complication, coronary artery obstruction, new pacemaker implantation occurred in 2.7, 2.7, 1.8, and 19.1% at 1-year follow-up, respectively. No patients had moderate or severe paravalvular leak at 1-year. At 1 year follow-up, 97% of patients had New York heart association ≤II. Patients with bicuspid valves had similar outcomes as those patients with tricuspid aortic valve stenosis. CONCLUSIONS: The 12-month clinical results support the safety and efficacy of VitaFlow™ in the treatment of patients with severe aortic stenosis, including patients with bicuspid aortic valve.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Valva Aórtica/patologia , Calcinose/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , China , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Hemodinâmica , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 95(7): 1340-1346, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31713325

RESUMO

OBJECTIVES: The United Kingdom and Ireland Implanters' registry is a multicenter registry which reports on real-world experience with new transcatheter heart valves. BACKGROUND: The Evolut PRO (Medtronic, Minneapolis, MN) transcatheter aortic valve is a self-expanding transcatheter aortic valve with an outer pericardial wrap, designed to minimize paravalvular regurgitation. METHODS: Between July 2017 and December 2018, clinical, procedural, and 30-day outcome data were prospectively collected from all patients receiving the Evolut PRO valve across nine participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2 (VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 317 patients underwent implantation. Mean age was 81.8 ± 6.4 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.5 ± 1.8%. Iliofemoral access was used in 99.1% of patients. Device success was 91.2%. Mean gradient was 7.6 ± 4.7 mmHg and effective orifice area 1.9 ± 0.7 cm2 . The incidence of moderate paravalvular regurgitation was 1.7% and there was no severe paravalvular regurgitation. A new permanent pacemaker was implanted in 17.8% of patients without a pacemaker at baseline. Early safety was demonstrated in 92.7%. At 30 days, all-cause mortality was 0.6%, stroke 3.8%, and major vascular complication 2.8%. CONCLUSIONS: Real-world experience of the Evolut PRO transcatheter aortic valve demonstrated favorable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Pericárdio/transplante , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Humanos , Irlanda , Masculino , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Reino Unido
13.
Eur Heart J ; 40(31): 2632-2653, 2019 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-31116395

RESUMO

Identification and management of patients at high bleeding risk undergoing percutaneous coronary intervention are of major importance, but a lack of standardization in defining this population limits trial design, data interpretation, and clinical decision-making. The Academic Research Consortium for High Bleeding Risk (ARC-HBR) is a collaboration among leading research organizations, regulatory authorities, and physician-scientists from the United States, Asia, and Europe focusing on percutaneous coronary intervention-related bleeding. Two meetings of the 31-member consortium were held in Washington, DC, in April 2018 and in Paris, France, in October 2018. These meetings were organized by the Cardiovascular European Research Center on behalf of the ARC-HBR group and included representatives of the US Food and Drug Administration and the Japanese Pharmaceuticals and Medical Devices Agency, as well as observers from the pharmaceutical and medical device industries. A consensus definition of patients at high bleeding risk was developed that was based on review of the available evidence. The definition is intended to provide consistency in defining this population for clinical trials and to complement clinical decision-making and regulatory review. The proposed ARC-HBR consensus document represents the first pragmatic approach to a consistent definition of high bleeding risk in clinical trials evaluating the safety and effectiveness of devices and drug regimens for patients undergoing percutaneous coronary intervention.


Assuntos
Stents Farmacológicos/efeitos adversos , Terapia Antiplaquetária Dupla/efeitos adversos , Hemorragia/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Stents/efeitos adversos , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Anemia/complicações , Anemia/epidemiologia , Anemia/fisiopatologia , Ásia/epidemiologia , Tomada de Decisão Clínica , Ensaios Clínicos como Assunto , Consenso , Europa (Continente)/epidemiologia , Fibrose/complicações , Fragilidade/complicações , Fragilidade/epidemiologia , Fragilidade/fisiopatologia , Hemorragia/epidemiologia , Humanos , Hipertensão Portal/epidemiologia , Hipertensão Portal/fisiopatologia , Adesão à Medicação/estatística & dados numéricos , Metais , Intervenção Coronária Percutânea/instrumentação , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/epidemiologia , Insuficiência Renal Crônica/fisiopatologia , Medição de Risco , Segurança , Trombocitopenia/complicações , Trombocitopenia/epidemiologia , Trombocitopenia/fisiopatologia , Resultado do Tratamento , Estados Unidos/epidemiologia
14.
Catheter Cardiovasc Interv ; 94(2): 195-203, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30628747

RESUMO

BACKGROUND: Clinical outcomes with respect to the evolution of comorbidity burden in national cohorts of patients undergoing PCI have not been reported. OBJECTIVES: We sought to explore the association between comorbidity burden and periprocedural outcomes in patients treated with PCI in the National Inpatient Sample. METHODS: 6,601,526 PCI procedures were identified between 2004 and 2014 and comorbidities were defined by the Elixhauser classification system (ECS) consisting of 30 comorbidity measures. Endpoints included in-hospital mortality, periprocedural complications, length of stay and cost. Patients were classified based on their ECS in five categories (ECS I < 0, ECS II = 0, ECS III = 1-5, ECS IV = 6-13, and ECS V ≥ 14). RESULTS: Patients with a score over 13 had a fivefold increase in the odds of mortality (OR: 5.13, 95% CI: 4.76-5.54), major bleeding (OR: 11.46, 95% CI: 10.66-12.33) and doubled the hospitalization costs ($31,452 vs $17.566). CONCLUSIONS: Our study of over six million PCI procedures demonstrates that patients with the greatest comorbid burden (as defined by an ECS of >13) have a fivefold increase risk of in-hospital mortality, a fourfold increase in in-hospital periprocedural complications and an 11-fold increase in major bleeding events once differences in baseline patient characteristics are adjusted for. In addition, ECS significantly impacts the length of stay and doubles the healthcare costs. Comorbid burden is an important predictor of poor outcomes after PCI and should be considered as part of the decision-making processes in patients undergoing PCI.


Assuntos
Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea , Idoso , Comorbidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/economia , Doença da Artéria Coronariana/mortalidade , Bases de Dados Factuais , Feminino , Custos Hospitalares , Mortalidade Hospitalar , Humanos , Pacientes Internados , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/economia , Intervenção Coronária Percutânea/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
15.
Catheter Cardiovasc Interv ; 93(4): 751-757, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30394657

RESUMO

OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Irlanda , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Reino Unido
16.
Eur Heart J ; 39(28): 2635-2642, 2018 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-29546396

RESUMO

Aims: The number of transcatheter aortic valve implantation (TAVI) procedures is rapidly increasing. This has a major impact on health care resource planning. However, the annual numbers of TAVI candidates per country are unknown. The aim of this study was to estimate current and future number of annual TAVI candidates in 27 European countries, the USA and Canada. Methods and results: Systematic literature searches and meta-analyses were performed on aortic stenosis (AS) epidemiology and decision-making in severe symptomatic AS. The incidence rate of severe AS was determined. Findings were combined with population statistics and integrated into a model employing Monte Carlo simulations to predict the annual number of TAVI candidates. Various future scenarios and sensitivity analyses were explored. Data from 37 studies (n = 26 402) informed the model. The calculated incidence rate of severe AS was 4.4‰/year [95% confidence interval (95% CI) 3.0-6.1‰] in patients ≥65 years. AS-related symptoms were present in 68.3% (95% CI 60.8-75.9%) of patients with severe AS. Despite having severe symptomatic AS, 41.6% (95% CI 36.9-46.3%) did not undergo surgical aortic valve replacement. Of the non-operated patients, 61.7% (95% CI 42.0-81.7%) received TAVI. The model predicted 114 757 (95% CI 69 380-172 799) European and 58 556 (95% CI 35 631-87 738) Northern-American TAVI candidates annually. Conclusion: Currently, approximately 180 000 patients can be considered potential TAVI candidates in the European Union and in Northern-America annually. This number might increase up to 270 000 if indications for TAVI expand to low-risk patients. These findings have major implications for health care resource planning in the 29 individual countries.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Canadá , Europa (Continente) , Previsões , Humanos , Seleção de Pacientes , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/tendências , Estados Unidos
17.
Eur Heart J ; 39(8): 676-684, 2018 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-29253177

RESUMO

Aims: Life-threatening complications occur during transcatheter aortic valve implantation (TAVI) which can require emergent cardiac surgery (ECS). Risks and outcomes of patients needing ECS during or immediately after TAVI are still unclear. Methods and results: Incidence, risk factors, management, and outcomes of patients requiring ECS during transfemoral (TF)-TAVI were analysed from a contemporary real-world multicentre registry. Between 2013 and 2016, 27 760 patients underwent TF-TAVI in 79 centres. Of these, 212 (0.76%) patients required ECS (age 82.4 ± 6.3 years, 67.5% females, logistic EuroSCORE: 17.1%, STS-score 5.8%). The risk of ECS declined from 2013 (1.07%) to 2014 (0.70%) but remained stable since. Annual TF-TAVI numbers have more than doubled from 2013 to 2016. Leading causes for ECS were left ventricular perforation by the guidewire (28.3%) and annular rupture (21.2%). Immediate procedural mortality (<72 h) of TF-TAVI patients requiring ECS was 34.6%. Overall in-hospital mortality was 46.0%, and highest in case of annular rupture (62%). Independent predictors of in-hospital mortality following ECS were age > 85 years [odds ratio (OR) 1.87, 95% confidence interval (95% CI) (1.02-3.45), P = 0.044], annular rupture [OR 1.96, 95% CI (0.94-4.10), P = 0.060], and immediate ECS [OR 3.12, 95% CI (1.07-9.11), P = 0.037]. One year of survival of the 114 patients surviving the in-hospital period was only 40.4%. Conclusion: Between 2014 and 2016, the need for ECS remained stable around 0.7%. Left ventricular guidewire perforation and annular rupture were the most frequent causes, accounting for almost half of ECS cases. Half of the patients could be salvaged by ECS-nevertheless, 1 year of all-cause mortality was high even in those ECS patients surviving the in-hospital period.


Assuntos
Estenose da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Mortalidade Hospitalar/tendências , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Procedimentos Cirúrgicos Cardíacos/tendências , Tratamento de Emergência/tendências , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Masculino , Sistema de Registros , Medição de Risco
18.
Am Heart J ; 205: 97-109, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30205242

RESUMO

Background: Percutaneous coronary intervention in complex bifurcation lesions is prone to suboptimal implantation results and is associated with increased risk of subsequent clinical events. Angiographic ambiguity is high during bifurcation stenting, but it is unknown if procedural guidance by intravascular optical coherence tomography (OCT) improves clinical outcome. Methods and Design: OCTOBER is a randomized, investigator-initiated, multicenter trial aimed to show superiority of OCT-guided stent implantation compared to standard angiographic-guided implantation in bifurcation lesions. The primary outcome measure is a 2-year composite end point of cardiac death, target lesion myocardial infarction, and ischemia-driven target lesion revascularization. The calculated sample size is 1,200 patients in total, and allocation is 1:1. Eligible patients have stable or unstable angina pectoris or stabilized non­ST elevation myocardial infarction, and a coronary bifurcation lesion with significant main vessel stenosis and more than 50 % stenosis in a side branch with a reference diameter ≥2.5mm. Treatment is performed by the provisional side branch stenting technique or 2-stent techniques, and the systematic OCT guiding protocol is aimed to evaluate (1) plaque preparation, (2) lesion length, (3) segmental reference sizes, (4) lesion coverage, (5) stent expansion, (6) malapposition, (7) wire positions, and (8) ostial results. Implications: A positive outcome of the OCTOBER trial may establish OCT as a routine tool for optimization of complex percutaneous coronary intervention, whereas a negative result would indicate that OCT remains a tool for ad hoc evaluation in selected cases.


Assuntos
Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Tomografia de Coerência Óptica/métodos , Idoso , Angiografia Coronária , Estenose Coronária/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
19.
Circulation ; 133(21): 2086-93, 2016 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-27217434

RESUMO

In the United States, new surgical heart valves can be approved on the basis of objective performance criteria (OPC). In contrast, the US Food and Drug Administration traditionally requires stricter criteria for transcatheter heart valve (THV) approval, including randomized, clinical trials. Recent US Food and Drug Administration approval of new-generation THVs based on single-arm studies has generated interest in alternative study approaches for THV device approval. This review evaluates whether THV device approval could follow a pathway analogous to that of surgical heart valves by incorporating OPC and provides several considerations and recommendations. Factors to be taken into account in the construction of OPC include the maturity of THV technology, variability in transcatheter aortic valve replacement practice, end points included as OPC, follow-up terms for specific OPC, patient populations to which these OPC apply, and (statistical) methods for OPC development. We recommend that approval of THV devices in the United States for low- and intermediate-risk patients or for new indications should provisionally rely on data from randomized, clinical trials. However, it is recommended that formal OPC be applied for approval of new-generation THVs for use in high- and extreme-risk patient populations.


Assuntos
Estenose da Valva Aórtica/cirurgia , Aprovação de Equipamentos/normas , Substituição da Valva Aórtica Transcateter/normas , Estenose da Valva Aórtica/epidemiologia , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA