Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Comput Assist Tomogr ; 41(6): 931-936, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28448423

RESUMO

OBJECTIVE: Dual-energy computed tomography high energy virtual monochromatic images (VMIs) can reduce artifact but suppress iodine attenuation in enhancing tumor. We investigated this trade-off to identify VMI(s) that strike the best balance between iodine detection and artifact reduction. METHODS: The study was performed using an Alderson radiation therapy phantom. Different iodine solutions (based on estimated tumor iodine content in situ using dual-energy computed tomography material decomposition) and different dental fillings were investigated. Spectral attenuation curves and quality index (QI: 1/SD) were evaluated. RESULTS: The relationship between iodine attenuation and QI depends on artifact severity and iodine concentration. For low to average concentration solutions degraded by mild to moderate artifact, the iodine attenuation and QI curves crossed at 95 keV. CONCLUSIONS: High energy VMIs less than 100 keV can achieve modest artifact reduction while preserving sufficient iodine attenuation and could represent a useful additional reconstruction for evaluation of head and neck cancer.


Assuntos
Artefatos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X/métodos , Humanos , Iodo , Estudos Retrospectivos
2.
J Comput Assist Tomogr ; 40(5): 806-14, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27224226

RESUMO

OBJECTIVE: The objective of this study was to compare the dual-energy computed tomography (CT) characteristics of parathyroid adenomas (PAs), thyroid tissue, and lymph nodes (LNs) and assess whether the spectral information can improve distinction of these tissues. METHODS: Dual-energy CT scans from 20 patients with pathologically proven PAs were retrospectively evaluated, identifying 19 eligible PAs and region of interest analysis used for spectral characterization. RESULTS: There was a significant difference in multiple spectral parameters between PAs, LNs, and the thyroid gland (P < 0.05-0.0001). The greatest difference in spectral characteristics of PAs compared with that of LNs was on the 25-second acquisition, whereas the 55-second acquisition was better for distinguishing PAs from the thyroid gland. CONCLUSIONS: Four-dimensional CT acquired in dual-energy CT mode has the potential to further enhance diagnostic accuracy for PA identification on individual phases of the perfusion study.


Assuntos
Adenoma/diagnóstico por imagem , Tomografia Computadorizada Quadridimensional/métodos , Neoplasias das Paratireoides/diagnóstico por imagem , Exposição à Radiação/análise , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Doses de Radiação , Exposição à Radiação/prevenção & controle , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
J Indian Assoc Pediatr Surg ; 15(1): 39-41, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21180507

RESUMO

We report a case of intralobar pulmonary sequestration with special emphasis on computed tomography (CT) angiography in determining the arterial supply and venous drainage, thus providing a detailed knowledge of the vasculature, which is of vital importance in surgery. The 3D volume rendering technique and maximum intensity projection images provide the vascular road map for the surgeon.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA