Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circ J ; 87(5): 619-628, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-36418112

RESUMO

BACKGROUND: The vessel healing process after implantation of biodegradable polymer (BP) and durable polymer (DP) everolimus-eluting stent (EES) in ST-elevation myocardial infarction (STEMI) lesions remains unclear.Methods and Results: We conducted a multicenter prospective randomized controlled trial to compare early (2 weeks) and mid-term (12 months) vascular responses after implantation of BP-EES vs. DP-EES in STEMI patients. In this prespecified subanalysis, serial coronary angioscopy (CAS) analysis was performed in 15 stents in the BP-EES arm (n=10 patients) and 14 stents in the DP-EES arm (n=10 patients). At the 2-week follow-up, there was no significant difference in the estimated marginal means of the neointimal coverage grade (primary endpoint) between the 2 arms (mean [±SE] 0.00±0.00 in both arms; P>0.999). There were no significant differences between the BP-EES and DP-EES groups in the yellow color grade (1.046±0.106 vs. 0.844±0.114, respectively; P=0.201) or the presence of thrombus (77.8% vs. 88.8%, respectively; P=0.205). At 12 months, competent strut coverage, defined as yellow color grade ≤1, no thrombus, and a neointimal coverage grade ≥1 was achieved more frequently in the BP-EES than DP-EES arm (85.2% vs. 53.1%; adjusted odds ratio 2.11 [95% confidence interval 1.26-3.53]; P=0.023). CONCLUSIONS: Neointimal coverage 2 weeks after implantation of BP-EES and DP-EES in STEMI lesions was comparable on CAS evaluation. However, at 1 year, BP-EES was independently associated with competent strut coverage.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Everolimo , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Sirolimo , Doença da Artéria Coronariana/terapia , Polímeros , Angioscopia , Estudos Prospectivos , Resultado do Tratamento , Implantes Absorvíveis
2.
Circ J ; 87(6): 857-865, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-36908118

RESUMO

BACKGROUND: P2Y12 inhibitor monotherapy without aspirin immediately after percutaneous coronary intervention (PCI) has not been tested in East Asian patients, so in this study we aimed to assess the safety and feasibility of reduced dose (3.75 mg/day) prasugrel monotherapy in Japanese patients presenting with chronic coronary syndrome (CCS).Methods and Results: ASET-JAPAN is a prospective, multicenter, single-arm pilot study that completed enrolment of 206 patients from 12 Japanese centers in September 2022. Patients with native de-novo coronary lesions and a SYNTAX score <23 were treated exclusively with biodegradable-polymer platinum-chromium everolimus-eluting stent(s). Patients were loaded with standard dual antiplatelet therapy (DAPT) and following successful PCI and optimal stent deployment, they received low-dose prasugrel (3.75 mg/day) monotherapy for 3 months. The primary ischemic endpoint was a composite of cardiac death, spontaneous target-vessel myocardial infarction, or definite stent thrombosis. The primary bleeding endpoint was Bleeding Academic Research Consortium (BARC) type 3 or 5. At 3-month follow-up, there were no primary bleeding or ischemic events, or any stent thrombosis. CONCLUSIONS: This pilot study showed the safety and feasibility of prasugrel monotherapy in selected low-risk Japanese patients with CCS. This "aspirin-free" strategy may be a safe alternative to traditional DAPT following PCI.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Cloridrato de Prasugrel , Humanos , Aspirina , População do Leste Asiático , Everolimo , Hemorragia , Japão , Intervenção Coronária Percutânea/métodos , Projetos Piloto , Platina , Polímeros , Cloridrato de Prasugrel/uso terapêutico , Estudos Prospectivos
4.
Catheter Cardiovasc Interv ; 90(1): 58-69, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27896897

RESUMO

BACKGROUND: Limited data are currently available on the performance of everolimus eluting bioresorbable vascular scaffold (BVS) for treatment of complex coronary lesions representative of daily practice. METHODS: This is a prospective, mono-center, single-arm study, reporting data after BVS implantation in patients presenting with stable, unstable angina, or non-ST segment elevation myocardial infarction caused by de novo stenotic lesions in native coronary arteries. No restrictions were applied to lesion complexity. Procedural results and 12-month clinical outcomes were reported. RESULTS: A total of 180 patients have been evaluated in the present study, with 249 treated coronary lesions. Device Success per lesion was 99.2%. A total of 119 calcified lesions were treated. Comparable results were observed among severe, moderate and noncalcified lesions in term of %diameter stenosis (%DS) (20.3 ± 10.5%, 17.8 ± 7.7%, 16.8 ± 8.6%; P = 0.112) and acute gain (1.36 ± 0.41 mm, 1.48 ± 0.44 mm, 1.56 ± 0.54 mm; P = 0.109). In bifurcations (54 lesions), side-branch ballooning after main vessel treatment was often performed (33.3%) with low rate of side-branch impairment (9.3%). A total of 29 cases with coronary total occlusions were treated. After BVS implantation %DS was not different from other lesion types (17.2 ± 9.4%, vs. 17.7 ± 8.6%; P = 0.780). At one year, all-cause mortality was reported in three cases. The rate of target lesion revascularization and target vessel revascularization was 3.3%. The rate of definite scaffold thrombosis was 2.6%. CONCLUSIONS: The implantation of the everolimus eluting bioresorbable vascular scaffold in an expanded range of coronary lesion types and clinical presentations was observed to be feasible with promising angiographic results and mid-term clinical outcomes. © 2016 Wiley Periodicals, Inc.


Assuntos
Implantes Absorvíveis , Angina Estável/terapia , Angina Instável/terapia , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Estenose Coronária/terapia , Everolimo/administração & dosagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Calcificação Vascular/terapia , Idoso , Angina Estável/diagnóstico por imagem , Angina Estável/mortalidade , Angina Instável/diagnóstico por imagem , Angina Instável/mortalidade , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Tomada de Decisão Clínica , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Everolimo/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/mortalidade , Seleção de Pacientes , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/mortalidade
5.
Catheter Cardiovasc Interv ; 89(4): 679-689, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28109054

RESUMO

By providing valuable information about the coronary artery wall and lumen, intravascular imaging may aid in optimizing interventional procedure results and thereby could improve clinical outcomes following percutaneous coronary intervention (PCI). Intravascular optical coherence tomography (OCT) is a light-based technology with a tissue penetration of approximately 1 to 3 mm and provides near histological resolution. It has emerged as a technological breakthrough in intravascular imaging with multiple clinical and research applications. OCT provides detailed visualization of the vessel following PCI and provides accurate assessment of post-procedural stent performance including detection of edge dissection, stent struts apposition, tissue prolapse, and healing parameters. Additionally, it can provide accurate characterization of plaque morphology and provides key information to optimize post-procedural outcomes. This manuscript aims to review the current clinical and research applications of intracoronary OCT and summarize the analytic OCT imaging software packages currently available. © 2017 Wiley Periodicals, Inc.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Intervenção Coronária Percutânea/métodos , Placa Aterosclerótica/diagnóstico , Cirurgia Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Doença da Artéria Coronariana/cirurgia , Humanos , Placa Aterosclerótica/cirurgia , Reprodutibilidade dos Testes
6.
Circ J ; 80(5): 1131-41, 2016 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-26936236

RESUMO

BACKGROUND: The edge vascular response (EVR) has been linked to important prognostic implications in patients treated with permanent metallic stents. We aimed to investigate the relationship of EVR with the geometric changes in the everolimus-eluting bioresorbable scaffold using serial optical coherence tomography (OCT) analysis. METHODS AND RESULTS: In the first-in-man ABSORB trial, 28 patients (29 lesions) underwent serial OCT at 4 different time points (Cohort B1: post-procedure, 6, 24, and 60 months [n=13]; Cohort B2: post-procedure, 12, 36, and 60 months [n=15]) following implantation of the scaffold. In Cohort B1, there was no significant luminal change at the distal or proximal edge segment throughout the entire follow-up. In contrast, there was a significant reduction of the lumen flow area (LFA) of the scaffold between post-procedure and 6 months (-1.03±0.49 mm(2)[P<0.001]), whereas between 6 and 60 months the LFA remained stable (+0.31±1.00 mm(2)[P=0.293]). In Cohort B2, there was a significant luminal reduction of the proximal edge between post-procedure and 12 months (-0.57±0.74 mm(2)[P=0.017]), whereas the lumen area remained stable (-0.26±1.22 mm(2)[P=0.462]) between 12 and 60 months. The scaffold LFA showed a change similar to that observed in Cohort B1. CONCLUSIONS: Our study demonstrated a reduction in the scaffold luminal area in the absence of major EVR, suggesting that the physiological continuity of the lumen contour is restored long term. (Circ J 2016; 80: 1131-1141).


Assuntos
Implantes Absorvíveis/normas , Stents Farmacológicos/normas , Everolimo/administração & dosagem , Tomografia de Coerência Óptica/métodos , Reestenose Coronária , Vasos Coronários/patologia , Seguimentos , Humanos , Estudos Longitudinais
7.
Catheter Cardiovasc Interv ; 85(4): 554-63, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25059819

RESUMO

BACKGROUND: The accuracy and precision of quantitative coronary angiography (QCA) software dedicated for bifurcation lesions compared with conventional single-vessel analysis remains unknown. Furthermore, comparison of different bifurcation analysis algorithms has not been performed. METHODS: Six plexiglas phantoms with 18 bifurcations were manufactured with a tolerance < 10 µm. The bifurcation angiograms were analyzed using Cardiovascular Angiography Analysis System (CAAS; Version 5.10, Pie Medical Imaging, Maastricht, The Netherlands) and QAngio XA (Version 7.3, Medis Medical Imaging System BV, Leiden, The Netherlands) software packages. RESULTS: Conventional single-vessel analysis underestimated the reference vessel diameter and percent diameter stenosis in the proximal main vessel while it overestimated these parameters in the distal main vessel and side branch. CAAS software showed better overall accuracy and precision than QAngio XA (with automatic Y- or T-shape bifurcation algorithm selection) for various phantom diameters including minimum lumen diameter (0.012 ± 0.103 mm vs. 0.041 ± 0.322 mm, P = 0.003), reference vessel diameter (-0.050 ± 0.043 mm vs. 0.116 ± 0.610 mm, P = 0.026), and % diameter stenosis (-0.94 ± 4.07 % vs. 1.74 ± 7.49 %, P = 0.041). QAngio XA demonstrated higher minimal lumen diameter, reference vessel diameter, and % diameter stenosis when compared to the actual phantom diameters; however, the accuracy of these parameters improved to a similar level as CAAS when the sole T-shape algorithm in the QAnxio XA was used. CONCLUSION: The use of the single-vessel QCA method is inaccurate in bifurcation lesions. Both CAAS and QAngio XA (when the T shape is systematically used) bifurcation software packages are suitable for quantitative assessment of bifurcations.


Assuntos
Algoritmos , Angiografia Coronária/instrumentação , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
8.
Catheter Cardiovasc Interv ; 86(3): E140-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25914327

RESUMO

BACKGROUND: Three-dimensional (3D) quantitative coronary angiography (QCA) provides more accurate measurements by minimizing inherent limitations of two-dimensional (2D) QCA. The aim of this study was to compare the measurements between 2D and 3D QCA analyses in bifurcation lesions. METHODS AND RESULTS: A total of 114 cases with non-left main bifurcation lesions in the TRYTON pivotal IDE Coronary Bifurcation Trial (ClinicalTrials.gov: NCT01258972) were analyzed using a validated bifurcation QCA software (CAAS 5.10, Pie Medical Imaging, Maastricht, the Netherlands). All cases were analyzed in matched projections between pre- and post-procedure. The 2D analysis was performed using one of two angiographic images used for 3D reconstruction showing a larger distal bifurcation angle. In the treated segments (stent and balloon), there were no differences in minimal luminal diameter (MLD) between 2D and 3D, while diameter stenosis (DS) was significantly higher in 2D compared to 3D both pre-procedure and post-procedure (53.9% for 2D vs. 52.1% for 3D pre-procedure, P < 0.01; 23.2% for 2D vs. 20.9% for 3D post-procedure, P = 0.01). In the sub-segment level analysis, lengths of proximal main branch, distal main branch, and side branch were consistently shorter in 2D compared to 3D both pre-procedure and post-procedure. Using 3D QCA, the anatomic location of the smallest MLD or the highest DS was relocated to a different bifurcation sub-segment in a considerable proportion of the patients compared to when 2D-QCA was used (kappa values: 0.50 for MLD, 0.55 for DS). CONCLUSIONS: Our data showed differences in addressing anatomical severity and location of coronary bifurcation lesions between in vivo 2D and 3D QCA analyses. More studies are needed to investigate potential clinical benefits in using 3D approach over 2D QCA for the assessment of bifurcation lesions.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Humanos , Imageamento Tridimensional , Software , Resultado do Tratamento
9.
Heart Vessels ; 30(6): 824-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25031154

RESUMO

Very late stent thrombosis (VLST) is a catastrophic complication after implantation of a drug-eluting stent (DES). It has been reported that VLST is associated with pathological changes, which often include late acquired incomplete stent apposition (LAISA) with thrombus formation. In addition, the vascular response to the stent (evaginations, neointimal growth, and thrombosis) and the incidence of LAISA are reported to vary among the different types of DES. We experienced a patient with cardiogenic shock induced by simultaneous VLST of both the left anterior descending artery (LAD) and the left circumflex artery (LCX) at 3 years after implantation of two sirolimus-eluting stents. Intravascular ultrasound (IVUS) showed LAISA of both arteries. A paclitaxel-eluting stent, which had been implanted in the right coronary artery 3 years earlier, did not show such a finding. IVUS revealed "different vascular reactions" to "different types of DES" in this patient.


Assuntos
Trombose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Choque Cardiogênico/etiologia , Angiografia Coronária , Trombose Coronária/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/uso terapêutico , Sirolimo/uso terapêutico , Resultado do Tratamento , Ultrassonografia de Intervenção
10.
Eur Heart J ; 35(12): 777-86, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24394380

RESUMO

AIMS: We evaluated the feasibility and the acute performance of the everolimus-eluting bioresorbable vascular scaffolds (BVS) for the treatment of patients presenting with ST-segment elevation myocardial infarction (STEMI). METHODS AND RESULTS: The present investigation is a prospective, single-arm, single-centre study, reporting data after the BVS implantation in STEMI patients. Quantitative coronary angiography and optical coherence tomography (OCT) data were evaluated. Clinical outcomes are reported at the 30-day follow-up. The intent-to-treat population comprises a total of 49 patients. The procedural success was 97.9%. Pre-procedure TIMI-flow was 0 in 50.0% of the patients; after the BVS implantation, a TIMI-flow III was achieved in 91.7% of patients and the post-procedure percentage diameter stenosis was 14.7 ± 8.2%. No patients had angiographically visible residual thrombus at the end of the procedure. Optical coherence tomography analysis performed in 31 patients showed that the post-procedure mean lumen area was 8.02 ± 1.92 mm(2), minimum lumen area 5.95 ± 1.61 mm(2), mean incomplete scaffold apposition area 0.118 ± 0.162 mm(2), mean intraluminal defect area 0.013 ± 0.017 mm(2), and mean percentage malapposed struts per patient 2.80 ± 3.90%. Scaffolds with >5% malapposed struts were 7. At the 30-day follow-up, target-lesion failure rate was 0%. Non-target-vessel revascularization and target-vessel myocardial infarction (MI) were reported. A non-target-vessel non-Q-wave MI occurred. No cases of cardiac death or scaffold thrombosis were observed. CONCLUSION: In the present series, the BVS implantation in patients presenting with acute MI appeared feasible, with high rate of final TIMI-flow III and good scaffold apposition. Larger studies are currently needed to confirm these preliminary data.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio/tratamento farmacológico , Sirolimo/análogos & derivados , Alicerces Teciduais , Moduladores de Tubulina/administração & dosagem , Implantes Absorvíveis , Everolimo , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sirolimo/administração & dosagem , Tempo para o Tratamento , Tomografia de Coerência Óptica , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA