Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Biomed Opt ; 23(5): 1-12, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29777581

RESUMO

Traumatic injury resulting in hemorrhage is a prevalent cause of death worldwide. The current standard of care for trauma patients is to restore hemostasis by controlling bleeding and administering intravenous volume resuscitation. Adequate resuscitation to restore tissue blood flow and oxygenation is critical within the first hours following admission to assess severity and avoid complications. However, current clinical methods for guiding resuscitation are not sensitive or specific enough to adequately understand the patient condition. To better address the shortcomings of the current methods, an approach to monitor intestinal perfusion and oxygenation using a multiwavelength (470, 560, and 630 nm) optical sensor has been developed based on photoplethysmography and reflectance spectroscopy. Specifically, two sensors were developed using three wavelengths to measure relative changes in the small intestine. Using vessel occlusion, systemic changes in oxygenation input, and induction of hemorrhagic shock, the capabilities and sensitivity of the sensor were explored in vivo. Pulsatile and nonpulsatile components of the red, blue, and green wavelength signals were analyzed for all three protocols (occlusion, systemic oxygenation changes, and shock) and were shown to differentiate perfusion and oxygenation changes in the jejunum. The blue and green signals produced better correlation to perfusion changes during occlusion and shock, while the red and blue signals, using a new correlation algorithm, produced better data for assessing changes in oxygenation induced both systemically and locally during shock. The conventional modulation ratio method was found to be an ineffective measure of oxygenation in the intestine due to noise and an algorithm was developed based on the Pearson correlation coefficient. The method utilized the difference in phase between two different wavelength signals to assess oxygen content. A combination of measures from the three wavelengths provided verification of oxygenation and perfusion states, and showed promise for the development of a clinical monitor.


Assuntos
Jejuno , Monitorização Fisiológica/instrumentação , Oximetria/instrumentação , Oxigênio/sangue , Processamento de Sinais Assistido por Computador , Algoritmos , Animais , Pressão Sanguínea/fisiologia , Desenho de Equipamento , Jejuno/irrigação sanguínea , Jejuno/fisiologia , Jejuno/cirurgia , Oximetria/métodos , Fotopletismografia/instrumentação , Coelhos , Fluxo Sanguíneo Regional/fisiologia , Choque Hemorrágico/sangue , Choque Hemorrágico/diagnóstico
2.
J Biomed Opt ; 17(7): 077008, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22894521

RESUMO

An implantable, optical oxygenation and perfusion sensor to monitor liver transplants during the two-week period following the transplant procedure is currently being developed. In order to minimize the number of animal experiments required for this research, a phantom that mimics the optical, anatomical, and physiologic flow properties of liver parenchyma is being developed as well. In this work, the suitability of this phantom for liver parenchyma perfusion research was evaluated by direct comparison of phantom perfusion data with data collected from in vivo porcine studies, both using the same prototype perfusion sensor. In vitro perfusion and occlusion experiments were performed on a single-layer and on a three-layer phantom perfused with a dye solution possessing the absorption properties of oxygenated hemoglobin. While both phantoms exhibited response patterns similar to the liver parenchyma, the signal measured from the multilayer phantom was three times higher than the single layer phantom and approximately 21 percent more sensitive to in vitro changes in perfusion. Although the multilayer phantom replicated the in vivo flow patterns more closely, the data suggests that both phantoms can be used in vitro to facilitate sensor design.


Assuntos
Biomimética/instrumentação , Transplante de Fígado/instrumentação , Transplante de Fígado/fisiologia , Fígado/fisiologia , Oximetria/instrumentação , Próteses e Implantes , Telemetria/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA