Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Lancet ; 402(10405): 883-936, 2023 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-37647926

RESUMO

Despite major advancements in cardiovascular medicine, sudden cardiac death (SCD) continues to be an enormous medical and societal challenge, claiming millions of lives every year. Efforts to prevent SCD are hampered by imperfect risk prediction and inadequate solutions to specifically address arrhythmogenesis. Although resuscitation strategies have witnessed substantial evolution, there is a need to strengthen the organisation of community interventions and emergency medical systems across varied locations and health-care structures. With all the technological and medical advances of the 21st century, the fact that survival from sudden cardiac arrest (SCA) remains lower than 10% in most parts of the world is unacceptable. Recognising this urgent need, the Lancet Commission on SCD was constituted, bringing together 30 international experts in varied disciplines. Consistent progress in tackling SCD will require a completely revamped approach to SCD prevention, with wide-sweeping policy changes that will empower the development of both governmental and community-based programmes to maximise survival from SCA, and to comprehensively attend to survivors and decedents' families after the event. International collaborative efforts that maximally leverage and connect the expertise of various research organisations will need to be prioritised to properly address identified gaps. The Commission places substantial emphasis on the need to develop a multidisciplinary strategy that encompasses all aspects of SCD prevention and treatment. The Commission provides a critical assessment of the current scientific efforts in the field, and puts forth key recommendations to challenge, activate, and intensify efforts by both the scientific and global community with new directions, research, and innovation to reduce the burden of SCD worldwide.


Assuntos
Fármacos Cardiovasculares , Morte Súbita Cardíaca , Humanos , Morte Súbita Cardíaca/prevenção & controle , Governo , Instalações de Saúde , Estudos Interdisciplinares
2.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37021342

RESUMO

AIMS: While elevated resting heart rate measured at a single point of time has been associated with cardiovascular outcomes, utility of continuous monitoring of nocturnal heart rate (NHR) has never been evaluated. We hypothesized that dynamic NHR changes may predict, at short term, impending cardiovascular events in patients equipped with a wearable cardioverter-defibrillator (WCD). METHODS AND RESULTS: The WEARIT-France prospective cohort study enrolled heart failure patients with WCD between 2014 and 2018. Night-time was defined as midnight to 7 a.m. NHR initial trajectories were classified into four categories based on mean NHR in the first week (High/Low) and NHR evolution over the second week (Up/Down) of WCD use. The primary endpoint was a composite of cardiovascular death and heart failure hospitalization. A total of 1013 [61 (interquartile range, IQR 53-68) years, 16% women, left ventricular ejection fraction 26% (IQR 22-30)] were included. During a median WCD wear duration of 68 (IQR 44-90) days, 58 patients (6%) experienced 69 events. After considering potential confounders, High-Up NHR trajectory was significantly associated with the primary endpoint compared to Low-Down [adjusted hazard ratio (HR) 6.08, 95% confidence interval (CI) 2.56-14.45, P < 0.001]. Additionally, a rise of >5 bpm in weekly average NHR from the preceding week was associated with 2.5 higher composite event risk (HR 2.51, 95% CI 1.22-5.18, P = 0.012) as well as total mortality (HR 11.21, 95% CI 3.55-35.37, P < 0.001) and cardiovascular hospitalization (HR 2.70, 95% CI 1.51-4.82, P < 0.001). CONCLUSION: Dynamic monitoring of NHR may allow timely identification of impending cardiovascular events, with the potential for 'pre-emptive' action. REGISTRATION NUMBER: Clinical Trials.gov Identifier: NCT03319160.


Assuntos
Insuficiência Cardíaca , Dispositivos Eletrônicos Vestíveis , Humanos , Feminino , Masculino , Estudos de Coortes , Frequência Cardíaca , Estudos Prospectivos , Volume Sistólico/fisiologia , Função Ventricular Esquerda , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Desfibriladores
3.
Europace ; 25(2): 627-633, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36256586

RESUMO

AIMS: Data on sports-related sudden cardiac arrest (SrSCA) among young adults in the general population are scarce. We aimed to determine the overall SrSCA incidence, characteristics, and outcomes in young adults. METHODS AND RESULTS: Prospective cohort study of all cases of SrSCA between 2012 and 2019 in Germany and Paris area, France, involving subjects aged 18-35 years. Detection of SrSCA was achieved via multiple sources, including emergency medical services (EMS) reporting and web-based screening of media releases. Cases and aetiologies were centrally adjudicated. Overall, a total of 147 SrSCA (mean age 28.1 ± 4.8 years, 95.2% males) occurred, with an overall burden of 4.77 [95% confidence interval (CI) 2.85-6.68] cases per million-year, including 12 (8.2%) cases in young competitive athletes. While bystander cardiopulmonary resuscitation (CPR) was initiated in 114 (82.6%), automated external defibrillator (AED) use by bystanders occurred only in a minority (7.5%). Public AED use prior to EMS arrival (odds ratio 6.25, 95% CI 1.48-43.20, P = 0.02) was the strongest independent predictor of survival at hospital discharge (38.1%). Among cases that benefited from both immediate bystander CPR and AED use, survival rate was 90.9%. Coronary artery disease was the most frequent aetiology (25.8%), mainly through acute coronary syndrome (86.9%). CONCLUSION: Sports-related sudden cardiac arrest in the young occurs mainly in recreational male sports participants. Public AED use remains disappointingly low, although survival may reach 90% among those who benefit from both bystander CPR and early defibrillation. Coronary artery disease is the most prevalent cause of SrSCA in young adults.


Assuntos
Reanimação Cardiopulmonar , Doença da Artéria Coronariana , Serviços Médicos de Emergência , Parada Cardíaca , Parada Cardíaca Extra-Hospitalar , Humanos , Masculino , Adulto Jovem , Adulto , Feminino , Reanimação Cardiopulmonar/métodos , Cardioversão Elétrica , Estudos Prospectivos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Serviços Médicos de Emergência/métodos , Parada Cardíaca Extra-Hospitalar/diagnóstico , Parada Cardíaca Extra-Hospitalar/epidemiologia , Parada Cardíaca Extra-Hospitalar/terapia
4.
Eur Heart J ; 43(15): 1457-1464, 2022 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-35139183

RESUMO

More than 40 years after the first implantable cardioverter-defibrillator (ICD) implantation, sudden cardiac death (SCD) still accounts for more than five million deaths worldwide every year. Huge efforts in the field notwithstanding, it is now increasingly evident that the current strategy of long-term prevention based on left ventricular ejection fraction as the key selection criterion is actually of very limited impact, also because the largest absolute numbers of SCD are encountered in the general population not known to be at risk. It has been recently reemphasized that SCD is often not so sudden, with almost half of the victims experiencing typical warning symptoms preceding the event. Importantly, heeded and prompt medical attention can dramatically improve survival. Essentially, such timely action increases the chances of the SCD event being witnessed by emergency medical services and provides the opportunity for early intervention. In addition, newer technologies incorporating digital data acquisition, transfer between interconnected devices, and artificial intelligence, should allow dynamic, real-time monitoring of diverse parameters and therefore better identification of subjects at short-term SCD risk. Along with warning symptoms, these developments allow a new approach of near-term prevention based on the hours and minutes preceding SCD. In the present review, we challenge the current paradigm of mid- and long-term prevention using ICD in patients at the highest risk of SCD, and introduce a complementary concept applicable to the entire population that would aim to pre-empt SCD by timely detection and intervention within the minutes or hours prior to the event.


Assuntos
Inteligência Artificial , Desfibriladores Implantáveis , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Humanos , Fatores de Risco , Volume Sistólico , Função Ventricular Esquerda
5.
Eur Heart J ; 43(47): 4887-4896, 2022 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-36303402

RESUMO

AIMS: Sudden cardiac arrest remains a major complication of acute myocardial infarction (AMI) and is frequently related to ventricular fibrillation (VF). Incidence and impact of VF among patients hospitalized for AMI were evaluated. METHODS AND RESULTS: Data from the FAST-MI programme consisting of 5 French nationwide prospective cohort studies between 1995 and 2015 were analysed, totally including 14 423 patients with AMI (66 ± 14 years, 72% males, 59% ST-elevation myocardial infarction). Overall, proportion of patients presenting in-hospital VF decreased from 3.9% in 1995 to 1.8% in 2015 (P < 0.001). One-year mortality decreased from 60.7% to 24.6% (P < 0.001). However, compared with patients who did not develop VF, the over-risk of 1-year mortality associated with VF was stable over time [hazard ratio (HR) 6.78, 95% confidence interval (CI) 5.03-9.14 in 1995 and HR 6.64, 95% CI 4.20-10.49 in 2015, P = 0.52]. This increased mortality in the VF group was mainly related to fatal events occurring prior to hospital discharge, representing 86.2% of 1-year mortality, despite the very low rate of implantable cardioverter defibrillator in the VF group (2.6%). CONCLUSION: This study demonstrates that in-hospital VF incidence and mortality in the setting of AMI have significantly decreased over the past 20 years. Nevertheless, VF remained steadily associated with approximately a 10-fold increased relative risk of in-hospital mortality, without an impact on post-discharge mortality. Beyond long-term cardiac defibrillation strategy, these results emphasize the need to identify in-hospital interventions to further reduce mortality in VF patients. STUDY REGISTRATION: ClinicalTrials.gov Identifier: NCT00673036, NCT01237418, NCT02566200.


Assuntos
Infarto do Miocárdio , Fibrilação Ventricular , Masculino , Humanos , Feminino , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia , Estudos Prospectivos , Assistência ao Convalescente , Alta do Paciente , Infarto do Miocárdio/complicações , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/terapia , Fatores de Risco
6.
J Cardiovasc Electrophysiol ; 33(5): 1013-1023, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35299286

RESUMO

BACKGROUND: Increasing numbers of patients with cardiac implantable electronic devices (CIEDs) are undergoing radiotherapy (RT) for cancer. The aim of the study was to prospectively evaluate the incidence, characteristics, and associated factors of CIED dysfunctions related to RT. METHODS: Between April 2013 and March 2020, all patients with a CIED who underwent ≥1 RT session were enrolled. Patients were monitored according to a systematic protocol, including device interrogation before the first and after each RT session. The primary endpoint was CIED dysfunction, defined as oversensing, total or partial deprogramming, and/or unrecoverable reset. RESULTS: We included a total of 92 CIED RT courses: 77 (83.7%) in patients with a pacemaker and 15 (16.3%) in those with an implantable cardioverter-defibrillator. Overall, 13 dysfunctions (14.1%) were observed during 92 courses (1509 sessions), giving an incidence of 0.9 per 100 sessions. These included nine deprogramming (three total resets to back-up pacing mode and six partial deprogramming that were all successfully reprogrammed), three transient oversensing, and one unrecoverable oversensing requiring CIED and leads replacement. There were no adverse clinical events related to device dysfunction. In multivariable analysis, neutron-producing irradiation (odds ratio [OR], 5.59; 95% confidence interval [CI], 1.09-28.65; p = .039) and cumulative tumor dose (OR, 1.05; 95% CI, 1.01-1.10; p = .007) remained significantly associated with CIED dysfunction. CONCLUSION: In this prospective study, transient or permanent subclinical CIED dysfunction occurred in 14.1% of RT courses. Our findings emphasize the importance of high-energy beams and neutron-producing irradiation in risk assessment.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Neoplasias , Marca-Passo Artificial , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Cardiopatias/terapia , Humanos , Neoplasias/radioterapia , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos
7.
Circ Res ; 127(2): 301-309, 2020 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-32833581

RESUMO

Emerging evidence suggests that atrial fibrillation (AF) may be associated with an increased risk of sudden cardiac death (SCD). However, AF shares risk factors with numerous cardiac conditions, including coronary heart disease and heart failure-the 2 most common substrates for SCD-making the AF-SCD relationship particularly challenging to address. A careful consideration of confounding factors is essential, since interventions for AF will be effective in reducing SCD only if there is a causal association between these 2 conditions. In this translational review, we detail the plausible underlying pathophysiological mechanisms through which AF may promote or lead to SCD, as well as the existing epidemiological evidence supporting an association between AF and SCD. While the role of AF in predicting SCD in the general population appears limited and not established, AF might be integrated to improve risk stratification in some specific phenotypes. Optimal AF management, including that of its associated conditions, appears to be of interest to prevent AF-related SCD, especially because the AF-SCD relationship is in part driven by heart failure.


Assuntos
Fibrilação Atrial/etiologia , Morte Súbita Cardíaca/etiologia , Fibrilação Atrial/epidemiologia , Morte Súbita Cardíaca/epidemiologia , Humanos
8.
Eur Heart J ; 42(34): 3338-3348, 2021 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-34263296

RESUMO

Rheumatic heart disease (RHD) is the result of episodes of acute rheumatic fever with valvular (and other cardiac) damage caused by an abnormal immune response to group A streptococcal infections, usually during childhood and adolescence. As a result of improved living conditions and the introduction of penicillin, RHD was almost eradicated in the developed world by the 1980s. However, being a disease of poverty, its burden remains disproportionately high in the developing world, despite being a fundamentally preventable disease. Rheumatic heart disease generates relatively little attention from the medical and science communities, in contrast to other common infectious problems (such as malaria, HIV, tuberculosis), despite the major cardiovascular morbidity/mortality burden imposed by RHD. This relative neglect and paucity of funding have probably contributed to limited fundamental medical advances in this field for over 50 years. Given the importance of prevention before the onset of major valvular damage, the main challenges for RHD prevention are improving social circumstances, early diagnosis, and effective delivery of antibiotic prophylaxis. Early identification through ultrasound of silent, subclinical rheumatic valve lesions could provide an opportunity for early intervention. Simple echocardiographic diagnostic criteria and appropriately trained personnel can be valuable aids in large-scale public health efforts. In addition, a better understanding of the immunogenic determinants of the disease may provide potential routes to vaccine development and other novel therapies.


Assuntos
Febre Reumática , Cardiopatia Reumática , Infecções Estreptocócicas , Adolescente , Humanos , Penicilinas , Febre Reumática/diagnóstico , Febre Reumática/epidemiologia , Febre Reumática/prevenção & controle , Cardiopatia Reumática/epidemiologia , Cardiopatia Reumática/prevenção & controle , Infecções Estreptocócicas/diagnóstico , Infecções Estreptocócicas/epidemiologia , Infecções Estreptocócicas/prevenção & controle , Ultrassonografia
9.
Circulation ; 142(17): 1612-1622, 2020 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-32998542

RESUMO

BACKGROUND: Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce. METHODS: A Nationwide French Registry including all patients with tetralogy of Fallot with an ICD was initiated in 2010 by the French Institute of Health and Medical Research. The primary time to event end point was the time from ICD implantation to first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age, 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (interquartile range) follow-up of 6.8 (2.5-11.4) years, 78 (47.3%) patients received at least 1 appropriate ICD therapy. The annual incidence of the primary outcome was 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively; P=0.03). Overall, 71 (43.0%) patients presented with at least 1 ICD complication, including inappropriate shocks in 42 (25.5%) patients and lead dysfunction in 36 (21.8%) patients. Among 61 (37.0%) patients in primary prevention, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with, respectively, 0, 1, 2, or ≥3 guidelines-recommended risk factors. QRS fragmentation was the only independent predictor of appropriate ICD therapies (hazard ratio, 3.47 [95% CI, 1.19-10.11]), and its integration in a model with current criteria increased the 5-year time-dependent area under the curve from 0.68 to 0.81 (P=0.006). Patients with congestive heart failure or reduced left ventricular ejection fraction had a higher risk of nonarrhythmic death or heart transplantation (hazard ratio, 11.01 [95% CI, 2.96-40.95]). CONCLUSIONS: Patients with tetralogy of Fallot and an ICD experience high rates of appropriate therapies, including those implanted in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria including QRS fragmentation might improve risk stratification. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03837574.


Assuntos
Desfibriladores Implantáveis/tendências , Tetralogia de Fallot/epidemiologia , Tetralogia de Fallot/terapia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Sistema de Registros
10.
N Engl J Med ; 389(11): 1056, 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37703566
11.
Europace ; 23(12): 2039-2045, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34308973

RESUMO

Catheter ablation for atrial fibrillation (AF) has become one of the most common procedures in the electrophysiology lab with rapidly increasing volumes. Peri-procedural anaesthesia for AF ablation varies between centres, from general anaesthesia to deep or conscious sedation. The aim of this survey was to assess current sedation practices for AF ablation worldwide and its evolution over the last decade. Centres regularly performing AF ablation responded to an online survey. A total of 297 centres participated in the survey. Overall, the median (interquartile range) number of AF ablation procedures increased from 91 (43-200) to 200 (74-350) per year (P < 0.001) between 2010 and 2019. The proportion of cryoablation also increased from 17.0% to 33.2% (P < 0.001). In 2019, the most used sedation technique was general anaesthesia (40.5%), followed by conscious sedation (32.0%) and deep sedation (27.5%). Between 2010 and 2019, the proportion of procedures performed under general anaesthesia (+4.4%; P = 0.02) and deep sedation (+4.8%; P < 0.01) increased, whereas the use of conscious sedation decreased (-9.2%; P < 0.001). The most commonly used hypnotic drugs were propofol and midazolam, whereas the most commonly used opioid drugs were remifentanyl and fentanyl. This worldwide survey shows that the number of AF ablation procedures has more than doubled over the last decade and general anaesthesia remains most commonly used. Studies comparing outcomes between different sedation strategies are needed to guide optimal decision-making.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Propofol , Anestesia Geral , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Humanos , Midazolam , Resultado do Tratamento
12.
Europace ; 23(1): 73-81, 2021 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-33257972

RESUMO

AIMS: We aimed to provide contemporary real-world data on wearable cardioverter-defibrillator (WCD) use, not only in terms of effectiveness and safety but also compliance and acceptability. METHODS AND RESULTS: Across 88 French centres, the WEARIT-France study enrolled retrospectively patients who used the WCD between May 2014 and December 2016, and prospectively all patients equipped for WCD therapy between January 2017 and March 2018. All patients received systematic education session through a standardized programme across France at the time of initiation of WCD therapy and were systematically enrolled in the LifeVest Network remote services. Overall, 1157 patients were included (mean age 60 ± 12 years, 16% women; 46% prospectively): 82.1% with ischaemic cardiomyopathy, 10.3% after implantable cardioverter-defibrillator explant, and 7.6% before heart transplantation. Median WCD usage period was 62 (37-97) days. Median daily wear time of WCD was 23.4 (22.2-23.8) h. In multivariate analysis, younger age was associated with lower compliance [adjusted odds ratio (OR) 0.97, 95% confidence interval (CI) 0.95-0.99, P < 0.01]. A total of 18 participants (1.6%) received at least one appropriate shock, giving an incidence of appropriate therapy of 7.2 per 100 patient-years. Patient-response button allowed the shock to be aborted in 35.7% of well-tolerated sustained ventricular arrhythmias and in 95.4% of inappropriate ventricular arrhythmia detection, finally resulting in an inappropriate therapy in eight patients (0.7%). CONCLUSION: Our real-life findings reinforce previous studies on the efficacy and safety of the WCD in the setting of transient high-risk group in selected patients. Moreover, they emphasize the fact that when prescribed appropriately, in concert with adequate patient education and dedicated follow-up using specific remote monitoring system, compliance with WCD is high and the device well-tolerated by the patient.


Assuntos
Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Idoso , Estudos de Coortes , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
13.
Eur Heart J ; 41(21): 1976-1986, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31750896

RESUMO

AIMS: While data from randomized trials suggest a declining incidence of sudden cardiac death (SCD) among heart failure patients, the extent to which such a trend is present among patients with cardiac resynchronization therapy (CRT) has not been evaluated. We therefore assessed changes in SCD incidence, and associated factors, in CRT recipients over the last 20 years. METHODS AND RESULTS: Literature search from inception to 30 April 2018 for observational and randomized studies involving CRT patients, with or without defibrillator, providing specific cause-of-death data. Sudden cardiac death was the primary endpoint. For each study, rate of SCD per 1000 patient-years of follow-up was calculated. Trend line graphs were subsequently constructed to assess change in SCD rates over time, which were further analysed by device type, patient characteristics, and medical therapy. Fifty-three studies, comprising 22 351 patients with 60 879 patient-years of follow-up and a total of 585 SCD, were included. There was a gradual decrease in SCD rates since the early 2000s in both randomized and observational studies, with rates falling more than four-fold. The rate of decline in SCD was steeper than that of all-cause mortality, and accordingly, the proportion of deaths which were due to SCD declined over the years. The magnitude of absolute decline in SCD was more prominent among CRT-pacemaker (CRT-P) patients compared to those receiving CRT-defibrillator (CRT-D), with the difference in SCD rates between CRT-P and CRT-D decreasing considerably over time. There was a progressive increase in age, use of beta-blockers, and left ventricular ejection fraction, and conversely, a decrease in QRS duration and antiarrhythmic drug use. CONCLUSION: Sudden cardiac death rates have progressively declined in the CRT heart failure population over time, with the difference between CRT-D vs. CRT-P recipients narrowing considerably.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Humanos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
14.
Artigo em Inglês | MEDLINE | ID: mdl-33129971

RESUMO

BACKGROUND: Left-sided ablation, targeting left inferior AV nodal extensions, is thought to be necessary for success in a small proportion of atrioventricular nodal re-entrant tachycardia (AVNRT) ablations; however Indian data are scarce in this regard. METHODS: Consecutive cases of AVNRT undergoing slow pathway ablation in a single centre over an 18-month period were retrospectively analyzed. Left-sided ablation at the posteroseptal mitral annulus was performed if right-sided ablation failed to abolish AVNRT. RESULTS: From January 2017 to June 2018, out of 215 consecutive supraventricular tachycardia (SVT) cases, 154 (71.6%) were AVNRT (47.1 ± 13.1 years, 46.1% male). Trans-septal ablation was required in 5 (3.2%) cases (mean age 48.8 ± 9.4 years; 4 female, 1 male); all with typical (slow-fast) form of AVNRT. Compared with cases needing only right-sided ablation, radiofrequency time (50.8 ± 16.9 vs. 9.9 ± 8.5 min; p = 0.005) and procedure time (166.0 ± 35.0 vs 79.6 ± 35.9 min; p = 0.004) were significantly longer for trans-septal cases, while baseline intervals and tachycardia cycle length were not significantly different. Junctional ectopy was seen in only 2 of the 5 cases during left-sided ablation, but acute success (non-inducibility) was obtained in 3 cases. There were no instances of AV block. Over mean follow-up of 12.2 ± 4.0 months, clinical recurrence of AVNRT occurred in one case, while others remained arrhythmia-free without medication. CONCLUSION: Left-sided ablation was required in a small proportion of AVNRT ablations. Trans-septal approach targeting the posteroseptal mitral annulus was safe and yielded good mid-term clinical success.

16.
Eur Heart J ; 40(26): 2121-2127, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31046090

RESUMO

AIMS: The very long-term outcome of patients who survive the first few years after receiving cardiac resynchronization therapy (CRT) has not been well described thus far. We aimed to provide long-term outcomes, especially with regard to the occurrence of sudden cardiac death (SCD), in CRT patients without (CRT-P) and with defibrillator (CRT-D). METHODS AND RESULTS: A total of 1775 patients, with ischaemic or non-ischaemic dilated cardiomyopathy, who were alive 5 years after CRT implantation, were enrolled in this multicentre European observational cohort study. Overall long-term mortality rates and specific causes of death were assessed, with a focus on late SCD. Over a mean follow-up of 30 months (interquartile range 10-42 months) beyond the first 5 years, we observed 473 deaths. The annual age-standardized mortality rates of CRT-D and CRT-P patients were 40.4 [95% confidence interval (CI) 35.3-45.5] and 97.2 (95% CI 85.5-109.9) per 1000 patient-years, respectively. The adjusted hazard ratio (HR) for all-cause mortality was 0.99 (95% CI 0.79-1.22). Twenty-nine patients in total died of late SCD (14 with CRT-P, 15 with CRT-D), corresponding to 6.1% of all causes of death in both device groups. Specific annual SCD rates were 8.5 and 5.8 per 1000 patient-years in CRT-P and CRT-D patients, respectively, with no significant difference between groups (adjusted HR 1.0, 95% CI 0.45-2.44). Death due to progressive heart failure represented the principal cause of death (42.8% in CRT-P patients and 52.6% among CRT-D recipients), whereas approximately one-third of deaths in both device groups were due to non-cardiovascular death. CONCLUSION: In this first description of very long-term outcomes among CRT recipients, progressive heart failure death still represented the most frequent cause of death in patients surviving the first 5 years after CRT implant. In contrast, SCD represents a very low proportion of late mortality irrespective of the presence of a defibrillator.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Morte Súbita Cardíaca/epidemiologia , Idoso , Estudos de Coortes , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Fatores de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Fatores de Tempo
17.
Circulation ; 138(6): 627-633, 2018 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-30354610

RESUMO

Catheter ablation has gained a prominent role in the management of atrial fibrillation (AF), with recent data providing positive evidence on hard outcomes, including hospitalization and mortality. Ablation, however, exposes the patient to a rather unique situation, combining risks for both major bleeding and thromboembolic events. In this setting, the critical importance of rigorous anticoagulation during the procedure has been underlined, and the latest international guidelines now recommend performing AF catheter ablation with uninterrupted non-vitamin K antagonist oral anticoagulants (NOACs) and concomitant administration of unfractionated heparin adjusted to achieve and maintain a target activated clotting time of ≥300 seconds. Whereas observational studies and randomized controlled trials support the safety and efficacy of uninterrupted NOAC strategy for AF catheter ablation, recent experiences have questioned this point, showing a greater unfractionated heparin requirement in NOAC-treated patients compared with vitamin K antagonists-treated patients to achieve the target activated clotting time. Important gaps in evidence regarding optimal intraprocedural anticoagulation management need to be acknowledged. A thorough appreciation of the physiology of anticoagulation during AF catheter ablation and the relevant differences between vitamin K antagonists and NOACs is required, while also understanding the limitations of activated clotting time measurement with regard to accurate intraprocedural anticogulation monitoring. This review aims to provide a critical look at this relatively ignored aspect of AF catheter ablation, especially pitfalls in NOAC monitoring, and to identify gaps in knowledge that need to be addressed in the near future.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/terapia , Coagulação Sanguínea/efeitos dos fármacos , Ablação por Cateter , Heparina/administração & dosagem , Cuidados Intraoperatórios/métodos , Administração Oral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/sangue , Fibrilação Atrial/diagnóstico , Testes de Coagulação Sanguínea , Ablação por Cateter/efeitos adversos , Esquema de Medicação , Hemorragia/induzido quimicamente , Heparina/efeitos adversos , Humanos , Cuidados Intraoperatórios/efeitos adversos , Monitorização Intraoperatória/métodos , Medição de Risco , Fatores de Risco , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Fatores de Tempo , Resultado do Tratamento
18.
Europace ; 21(7): 1063-1069, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30891608

RESUMO

AIMS: Current guidelines do not propose any age cut-off for the primary prevention implantable cardioverter-defibrillator (ICD). However, the risk/benefit balance in the very elderly population has not been well studied. METHODS AND RESULTS: In a multicentre French study assessing patients implanted with an ICD for primary prevention, outcomes among patients aged ≥80 years were compared with <80 years old controls matched for sex and underlying heart disease (ischaemic and dilated cardiomyopathy). A total of 300 ICD recipients were enrolled in this specific analysis, including 150 patients ≥80 years (mean age 81.9 ± 2.0 years; 86.7% males) and 150 controls (mean age 61.8 ± 10.8 years). Among older patients, 92 (75.6%) had no more than one associated comorbidity. Most subjects in the elderly group got an ICD as part of a cardiac resynchronization therapy procedure (74% vs. 46%, P < 0.0001). After a mean follow-up of 3.0 ± 2 years, 53 patients (35%) in the elderly group died, including 38.2% from non cardiovascular causes of death. Similar proportion of patients received ≥1 appropriate therapy (19.4% vs. 21.6%; P = 0.65) in the elderly group and controls, respectively. There was a trend towards more early perioperative events (P = 0.10) in the elderly, with no significant increase in late complications (P = 0.73). CONCLUSION: Primary prevention ICD recipients ≥80 years in the real world had relatively low associated comorbidity. Rates of appropriate therapies and device-related complications were similar, compared with younger subjects. Nevertheless, the inherent limitations in interpreting observational data on this particular competing risk situation call for randomized controlled trials to provide definitive answers. Meanwhile, a careful multidisciplinary evaluation is needed to guide patient selection for ICD implantation in the elderly population.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Prevenção Primária , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade
20.
Eur Heart J ; 39(16): 1459-1465, 2018 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-28444167

RESUMO

Electrical injuries are a commonly encountered hazard in both the home and workplace. However, clinicians are often uncomfortable when faced with the patient who presents with an electric shock due to sparse literature and lack of systematic recommendations on this topic. Electrical injuries can range from minor skin burns to life threatening internal organ damage. A thorough clinical assessment to ascertain the path of current through the body and possible internal injury is essential. The main concern in an apparently stable individual after an electric shock is the potential for delayed occurrence of cardiac arrhythmias which will require monitoring in the intensive care setting. While it may be reasonable to discharge home from the emergency room selected patients with low voltage injuries, absence of syncope and a normal ECG, others may require monitoring for at least 24 h. Public education and increasing workplace as well as home safety measures are key steps in prevention. The present review summarizes current knowledge in pathophysiology, manifestations and management of electrical injuries, with specific focus on cardiac effects.


Assuntos
Traumatismos por Eletricidade/terapia , Traumatismos Cardíacos/terapia , Traumatismos por Eletricidade/diagnóstico , Traumatismos por Eletricidade/fisiopatologia , Traumatismos Cardíacos/diagnóstico , Traumatismos Cardíacos/fisiopatologia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA