Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Virol J ; 12: 30, 2015 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-25889833

RESUMO

BACKGROUND: In Brazil, ordinance no. 2,914/2011 of the Ministry of Health requires the absence of total coliforms and Escherichia coli (E. coli) in treated water. However it is essential that water treatment is effective against all pathogens. Disinfection in Water Treatment Plants (WTP) is commonly performed with chlorine. METHODS: The recombinant adenovirus (rAdV), which expresses green fluorescent protein (GFP) when cultivated in HEK 293A cells, was chosen as a model to evaluate the efficiency of chlorine for human adenovirus (HAdV) inactivation in filtered water samples from two WTPs: Lagoa do Peri (pH 6.9) and Morro dos Quadros (pH 6.5). Buffered demand free (BDF) water (pH 6.9 and 8.0) was used as control. The samples were previously submitted to physicochemical characterization, and bacteriological analysis. Two free chlorine concentrations and two temperatures were assayed for all samples (0.2 mg/L, 0.5 mg/L, and 15°C, and 20°C). Fluorescence microscopy (FM) was used to check viral infectivity in vitro and qPCR as a molecular method to determine viral genome copies. Real treated water samples from the WTP (at the output of WTP and the distribution network) were also evaluated for total coliforms, E. coli and HAdV. RESULTS: The time required to inactivate 4log10 of rAdV was less than 1 min, when analyzed by FM, except for BDF pH 8.0 (up to 2.5 min for 4log10). The pH had a significant influence on the efficiency of disinfection. The qPCR assay was not able to provide information regarding rAdV inactivation. The data were modeled (Chick-Watson), and the observed Ct values were comparable with the values reported in the literature and smaller than the values recommended by the EPA. In the treated water samples, HAdV was detected in the distribution network of the WTP Morro dos Quadros (2.75 × 10(3) PFU/L). CONCLUSION: The Chick-Watson model proved to have adjusted well to the experimental conditions used, and it was possible to prove that the adenoviruses were rapidly inactivated in the surface water treated with chlorine and that the recombinant adenovirus expressing GFP is a good model for this evaluation.


Assuntos
Adenovírus Humanos/efeitos dos fármacos , Cloro/farmacologia , Desinfetantes/farmacologia , Desinfecção/métodos , Água Doce/virologia , Adenovírus Humanos/genética , Adenovírus Humanos/fisiologia , Brasil , Filtração , Água Doce/química , Humanos , Inativação de Vírus/efeitos dos fármacos , Purificação da Água/instrumentação
2.
Virol J ; 10: 166, 2013 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-23714224

RESUMO

BACKGROUND: Human adenoviruses (HAdVs) are the second-leading cause of childhood gastroenteritis worldwide. This virus is commonly found in environmental waters and is very resistant to water disinfection and environmental stressors, especially UV light inactivation. Molecular techniques, such as PCR-based methods (Polymerase Chain Reaction), are commonly used to detect and identify viral contamination in water, although PCR alone does not allow the discrimination between infectious and non-infectious viral particles. A combination of cell culture and PCR has allowed detection of infectious viruses that grow slowly or fail to produce cytopathic effects (CPE) in cell culture. This study aimed to assess the integrity and viability of human adenovirus (HAdV) in environmental water and evaluate circulating strains by molecular characterization in three sites of the water supply in Florianópolis, Santa Catarina Island, Brazil: Peri Lagoon water, spring source water, and water from the public water supply system. METHODS: Water samples were collected, concentrated and HAdV quantified by real-time PCR. Viral integrity was evaluated by enzymatic assay (DNase I) and infectivity by plaque assay (PA) and integrated cell culture using transcribed mRNA (ICC-RT-qPCR). Samples containing particles of infectious HAdV were selected for sequencing and molecular characterization. RESULTS: The analyzed sites contained 83, 66 and 58% undamaged HAdV particles (defined as those in which the genetic material is protected by the viral capsid) at Peri Lagoon, spring source water and public supply system water, respectively. Of these, 66% of the particles (by PA) and 75% (by ICC-RT-qPCR) HAdV were shown to be infectious, due to being undamaged in Peri Lagoon, 33% (by PA) and 58% (by ICC-RT-qPCR) in spring source water and 8% (by PA) and 25% (by ICC-RT-qPCR) in the public water supply system. ICC-RT-qPCR, a very sensitive and rapid technique, was able to detect as low as 1 × 102 HAdV genome copies per milliliter of infectious viral particles in the environmental water samples. The molecular characterization studies indicated that HAdV-2 was the prevalent serotype. CONCLUSIONS: These results indicate a lack of proper public health measures. We suggest that HAdV can be efficiently used as a marker of environmental and drinking water contamination and ICC-RT-qPCR demonstrated greater sensitivity and speed of detection of infectious viral particles compared to PA.


Assuntos
Adenovírus Humanos/isolamento & purificação , Adenovírus Humanos/fisiologia , Água Potável/virologia , Viabilidade Microbiana , Adenovírus Humanos/genética , Brasil , DNA Viral/metabolismo , Desoxirribonuclease I/metabolismo , Humanos , Reação em Cadeia da Polimerase em Tempo Real , Carga Viral
3.
Food Environ Virol ; 7(1): 67-75, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25528135

RESUMO

Shellfish depuration is a process that aims to eliminate pathogens from mollusk tissues. Seawater disinfection during the depuration process is important and ultraviolet (UV) light treatment is the most used method worldwide. Viral models are usually employed as surrogates of fastidious viruses in viability studies. The aim of this study was to employ methods based on green fluorescent protein (GFP) fluorescence and plaque forming units to detect, respectively, recombinant adenovirus (rAdV-GFP) and murine norovirus (MNV) artificially seeded in environmental matrices. These assays were applied to assess the inactivation of rAdV-GFP and MNV in seawater in recirculation shellfish depuration tanks with and without UV light treatment. Kinetics of rAdV GFP-expression was previously measured by UV-spectrophotometer. Flow cytometry (FC), fluorescence microscopy (FM), and plaque assay were used to determine virus titer and detection limits. The influence of the environmental matrix on the performance of the methods was prior determined using either drinking water or filtered seawater seeded with rAdV-GFP. Disinfection of seeded seawater was evaluated with and without UV treatment. The time of 24-h post-infection was established as ideal for fluorescence detection on rAdV-GFP infected cells. FC showed lower sensitivity, when compared to FM, which was similar to plaque assay. Seawater disinfection on depuration tanks was promising and rAdV-GFP declined 99.99 % after 24 and 48 h with and without UV treatment, respectively. MNV was completely inactivated after 24 h in both treatments. As conclusion, the depuration tanks were effective to inactivate rAdV-GFP and MNV and the UV disinfection treatment accelerated the process.


Assuntos
Adenovírus Humanos/efeitos da radiação , Manipulação de Alimentos/instrumentação , Irradiação de Alimentos/métodos , Moluscos/virologia , Norovirus/efeitos da radiação , Água do Mar/virologia , Frutos do Mar/virologia , Adenovírus Humanos/genética , Adenovírus Humanos/crescimento & desenvolvimento , Animais , Humanos , Camundongos , Norovirus/crescimento & desenvolvimento , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA