Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Blood ; 142(26): 2315-2326, 2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-37890142

RESUMO

ABSTRACT: Platelet demand management (PDM) is a resource-consuming task for physicians and transfusion managers of large hospitals. Inpatient numbers and institutional standards play significant roles in PDM. However, reliance on these factors alone commonly results in platelet shortages. Using data from multiple sources, we developed, validated, tested, and implemented a patient-specific approach to support PDM that uses a deep learning-based risk score to forecast platelet transfusions for each hospitalized patient in the next 24 hours. The models were developed using retrospective electronic health record data of 34 809 patients treated between 2017 and 2022. Static and time-dependent features included demographics, diagnoses, procedures, blood counts, past transfusions, hematotoxic medications, and hospitalization duration. Using an expanding window approach, we created a training and live-prediction pipeline with a 30-day input and 24-hour forecast. Hyperparameter tuning determined the best validation area under the precision-recall curve (AUC-PR) score for long short-term memory deep learning models, which were then tested on independent data sets from the same hospital. The model tailored for hematology and oncology patients exhibited the best performance (AUC-PR, 0.84; area under the receiver operating characteristic curve [ROC-AUC], 0.98), followed by a multispecialty model covering all other patients (AUC-PR, 0.73). The model specific to cardiothoracic surgery had the lowest performance (AUC-PR, 0.42), likely because of unexpected intrasurgery bleedings. To our knowledge, this is the first deep learning-based platelet transfusion predictor enabling individualized 24-hour risk assessments at high AUC-PR. Implemented as a decision-support system, deep-learning forecasts might improve patient care by detecting platelet demand earlier and preventing critical transfusion shortages.


Assuntos
Aprendizado Profundo , Humanos , Transfusão de Plaquetas , Estudos Retrospectivos , Aprendizado de Máquina , Medição de Risco
2.
Eur Radiol ; 34(1): 330-337, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37505252

RESUMO

OBJECTIVES: Provide physicians and researchers an efficient way to extract information from weakly structured radiology reports with natural language processing (NLP) machine learning models. METHODS: We evaluate seven different German bidirectional encoder representations from transformers (BERT) models on a dataset of 857,783 unlabeled radiology reports and an annotated reading comprehension dataset in the format of SQuAD 2.0 based on 1223 additional reports. RESULTS: Continued pre-training of a BERT model on the radiology dataset and a medical online encyclopedia resulted in the most accurate model with an F1-score of 83.97% and an exact match score of 71.63% for answerable questions and 96.01% accuracy in detecting unanswerable questions. Fine-tuning a non-medical model without further pre-training led to the lowest-performing model. The final model proved stable against variation in the formulations of questions and in dealing with questions on topics excluded from the training set. CONCLUSIONS: General domain BERT models further pre-trained on radiological data achieve high accuracy in answering questions on radiology reports. We propose to integrate our approach into the workflow of medical practitioners and researchers to extract information from radiology reports. CLINICAL RELEVANCE STATEMENT: By reducing the need for manual searches of radiology reports, radiologists' resources are freed up, which indirectly benefits patients. KEY POINTS: • BERT models pre-trained on general domain datasets and radiology reports achieve high accuracy (83.97% F1-score) on question-answering for radiology reports. • The best performing model achieves an F1-score of 83.97% for answerable questions and 96.01% accuracy for questions without an answer. • Additional radiology-specific pretraining of all investigated BERT models improves their performance.


Assuntos
Armazenamento e Recuperação da Informação , Radiologia , Humanos , Idioma , Aprendizado de Máquina , Processamento de Linguagem Natural
3.
Psychooncology ; 32(11): 1727-1735, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37789593

RESUMO

OBJECTIVE: Distress assessment of cancer patients is considered state-of-the-art. In addition to distress scores, individual care needs are an important factor for the initiation of psycho-oncological interventions. In a mono-centric, observational study, we aimed for characterization of patients indicating a subjective need but declining to utilize support services immediately to facilitate implementation of adapted screenings. METHODS: This study analyzed retrospective data from routine distress screening and associated data from hospital records. Descriptive, variance and regression analyses were used to assess characteristics of postponed support utilization in patients with mixed cancer diagnoses in different treatment settings. RESULTS: Of the total sample (N = 1863), 13% indicated a subjective need but postponed support utilization. This subgroup presented as being as burdened by symptoms of depression (p < 0.001), anxiety (p < 0.001) and distress (p < 0.001) as subjectively distressed patients with intent to directly utilize support. Time periods since diagnosis were shorter (p = 0.007) and patients were more often inpatients (p = 0.045). CONCLUSIONS: Despite high heterogeneity among the subgroups, this study identified distress-related factors and time since diagnosis as possible predictors for postponed utilization of psycho-oncological interventions. Results suggest the necessity for time-individualized support which may improve utilization by distressed patients.


Assuntos
Detecção Precoce de Câncer , Neoplasias , Humanos , Estudos Retrospectivos , Estresse Psicológico/terapia , Neoplasias/terapia , Pacientes Internados
4.
BMC Med Imaging ; 23(1): 104, 2023 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-37553619

RESUMO

In this work, we propose a processing pipeline for the extraction and identification of meaningful radiomics biomarkers in skeletal muscle tissue as displayed using Dixon-weighted MRI. Diverse and robust radiomics features can be identified that may be of aid in the accurate quantification e.g. varying degrees of sarcopenia in respective muscles of large cohorts. As such, the approach comprises the texture feature extraction from raw data based on well established approaches, such as a nnU-Net neural network and the Pyradiomics toolbox, a subsequent selection according to adequate conditions for the muscle tissue of the general population, and an importance-based ranking to further narrow the amount of meaningful features with respect to auxiliary targets. The performance was investigated with respect to the included auxiliary targets, namely age, body mass index (BMI), and fat fraction (FF). Four skeletal muscles with different fiber architecture were included: the mm. glutaei, m. psoas, as well as the extensors and adductors of the thigh. The selection allowed for a reduction from 1015 available texture features to 65 for age, 53 for BMI, and 36 for FF from the available fat/water contrast images considering all muscles jointly. Further, the dependence of the importance rankings calculated for the auxiliary targets on validation sets (in a cross-validation scheme) was investigated by boxplots. In addition, significant differences between subgroups of respective auxiliary targets as well as between both sexes were shown to be present within the ten lowest ranked features by means of Kruskal-Wallis H-tests and Mann-Whitney U-tests. The prediction performance for the selected features and the ranking scheme were verified on validation sets by a random forest based multi-class classification, with strong area under the curve (AUC) values of the receiver operator characteristic (ROC) of 73.03 ± 0.70 % and 73.63 ± 0.70 % for the water and fat images in age, 80.68 ± 0.30 % and 88.03 ± 0.89 % in BMI, as well as 98.36 ± 0.03 % and 98.52 ± 0.09 % in FF.


Assuntos
Imageamento por Ressonância Magnética , Sarcopenia , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/diagnóstico por imagem , Sarcopenia/diagnóstico por imagem , Biomarcadores , Estudos Retrospectivos
5.
BMC Health Serv Res ; 23(1): 734, 2023 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-37415138

RESUMO

BACKGROUND: We present FHIR-PYrate, a Python package to handle the full clinical data collection and extraction process. The software is to be plugged into a modern hospital domain, where electronic patient records are used to handle the entire patient's history. Most research institutes follow the same procedures to build study cohorts, but mainly in a non-standardized and repetitive way. As a result, researchers spend time writing boilerplate code, which could be used for more challenging tasks. METHODS: The package can improve and simplify existing processes in the clinical research environment. It collects all needed functionalities into a straightforward interface that can be used to query a FHIR server, download imaging studies and filter clinical documents. The full capacity of the search mechanism of the FHIR REST API is available to the user, leading to a uniform querying process for all resources, thus simplifying the customization of each use case. Additionally, valuable features like parallelization and filtering are included to make it more performant. RESULTS: As an exemplary practical application, the package can be used to analyze the prognostic significance of routine CT imaging and clinical data in breast cancer with tumor metastases in the lungs. In this example, the initial patient cohort is first collected using ICD-10 codes. For these patients, the survival information is also gathered. Some additional clinical data is retrieved, and CT scans of the thorax are downloaded. Finally, the survival analysis can be computed using a deep learning model with the CT scans, the TNM staging and positivity of relevant markers as input. This process may vary depending on the FHIR server and available clinical data, and can be customized to cover even more use cases. CONCLUSIONS: FHIR-PYrate opens up the possibility to quickly and easily retrieve FHIR data, download image data, and search medical documents for keywords within a Python package. With the demonstrated functionality, FHIR-PYrate opens an easy way to assemble research collectives automatically.


Assuntos
Ciência de Dados , Nível Sete de Saúde , Humanos , Registros Eletrônicos de Saúde , Software , Tomografia Computadorizada por Raios X
6.
Transfus Med Hemother ; 50(4): 277-285, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37767277

RESUMO

Introduction: An increasing shortage of donor blood is expected, considering the demographic change in Germany. Due to the short shelf life and varying daily fluctuations in consumption, the storage of platelet concentrates (PCs) becomes challenging. This emphasizes the need for reliable prediction of needed PCs for the blood bank inventories. Therefore, the objective of this study was to evaluate multimodal data from multiple source systems within a hospital to predict the number of platelet transfusions in 3 days on a per-patient level. Methods: Data were collected from 25,190 (42% female and 58% male) patients between 2017 and 2021. For each patient, the number of received PCs, platelet count blood tests, drugs causing thrombocytopenia, acute platelet diseases, procedures, age, gender, and the period of a patient's hospital stay were collected. Two models were trained on samples using a sliding window of 7 days as input and a day 3 target. The model predicts whether a patient will be transfused 3 days in the future. The model was trained with an excessive hyperparameter search using patient-level repeated 5-fold cross-validation to optimize the average macro F2-score. Results: The trained models were tested on 5,022 unique patients. The best-performing model has a specificity of 0.99, a sensitivity of 0.37, an area under the precision-recall curve score of 0.45, an MCC score of 0.43, and an F1-score of 0.43. However, the model does not generalize well for cases when the need for a platelet transfusion is recognized. Conclusion: A patient AI-based platelet forecast could improve logistics management and reduce blood product waste. In this study, we build the first model to predict patient individual platelet demand. To the best of our knowledge, we are the first to introduce this approach. Our model predicts the need for platelet units for 3 days in the future. While sensitivity underperforms, specificity performs reliably. The model may be of clinical use as a pretest for potential patients needing a platelet transfusion within the next 3 days. As sensitivity needs to be improved, further studies should introduce deep learning and wider patient characterization to the methodological multimodal, multisource data approach. Furthermore, a hospital-wide consumption of PCs could be derived from individual predictions.

7.
Eur J Nucl Med Mol Imaging ; 49(13): 4503-4515, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35904589

RESUMO

PURPOSE: Both digital positron emission tomography (PET) detector technologies and artificial intelligence based image post-reconstruction methods allow to reduce the PET acquisition time while maintaining diagnostic quality. The aim of this study was to acquire ultra-low-count fluorodeoxyglucose (FDG) ExtremePET images on a digital PET/computed tomography (CT) scanner at an acquisition time comparable to a CT scan and to generate synthetic full-dose PET images using an artificial neural network. METHODS: This is a prospective, single-arm, single-center phase I/II imaging study. A total of 587 patients were included. For each patient, a standard and an ultra-low-count FDG PET/CT scan (whole-body acquisition time about 30 s) were acquired. A modified pix2pixHD deep-learning network was trained employing 387 data sets as training and 200 as test cohort. Three models (PET-only and PET/CT with or without group convolution) were compared. Detectability and quantification were evaluated. RESULTS: The PET/CT input model with group convolution performed best regarding lesion signal recovery and was selected for detailed evaluation. Synthetic PET images were of high visual image quality; mean absolute lesion SUVmax (maximum standardized uptake value) difference was 1.5. Patient-based sensitivity and specificity for lesion detection were 79% and 100%, respectively. Not-detected lesions were of lower tracer uptake and lesion volume. In a matched-pair comparison, patient-based (lesion-based) detection rate was 89% (78%) for PERCIST (PET response criteria in solid tumors)-measurable and 36% (22%) for non PERCIST-measurable lesions. CONCLUSION: Lesion detectability and lesion quantification were promising in the context of extremely fast acquisition times. Possible application scenarios might include re-staging of late-stage cancer patients, in whom assessment of total tumor burden can be of higher relevance than detailed evaluation of small and low-uptake lesions.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Inteligência Artificial , Estudos Prospectivos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos
8.
Eur Radiol ; 32(12): 8769-8776, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35788757

RESUMO

OBJECTIVES: Over the course of their treatment, patients often switch hospitals, requiring staff at the new hospital to import external imaging studies to their local database. In this study, the authors present MOdality Mapping and Orchestration (MOMO), a Deep Learning-based approach to automate this mapping process by combining metadata analysis and a neural network ensemble. METHODS: A set of 11,934 imaging series with existing anatomical labels was retrieved from the PACS database of the local hospital to train an ensemble of neural networks (DenseNet-161 and ResNet-152), which process radiological images and predict the type of study they belong to. We developed an algorithm that automatically extracts relevant metadata from imaging studies, regardless of their structure, and combines it with the neural network ensemble, forming a powerful classifier. A set of 843 anonymized external studies from 321 hospitals was hand-labeled to assess performance. We tested several variations of this algorithm. RESULTS: MOMO achieves 92.71% accuracy and 2.63% minor errors (at 99.29% predictive power) on the external study classification task, outperforming both a commercial product (82.86% accuracy, 1.36% minor errors, 96.20% predictive power) and a pure neural network ensemble (72.69% accuracy, 10.3% minor errors, 99.05% predictive power) performing the same task. We find that the highest performance is achieved by an algorithm that combines all information into one vote-based classifier. CONCLUSION: Deep Learning combined with metadata matching is a promising and flexible approach for the automated classification of external DICOM studies for PACS archiving. KEY POINTS: • The algorithm can successfully identify 76 medical study types across seven modalities (CT, X-ray angiography, radiographs, MRI, PET (+CT/MRI), ultrasound, and mammograms). • The algorithm outperforms a commercial product performing the same task by a significant margin (> 9% accuracy gain). • The performance of the algorithm increases through the application of Deep Learning techniques.


Assuntos
Aprendizado Profundo , Humanos , Redes Neurais de Computação , Algoritmos , Bases de Dados Factuais , Imageamento por Ressonância Magnética/métodos
9.
J Nucl Cardiol ; 29(2): 779-789, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33025472

RESUMO

PURPOSE: Bone-tracer scintigraphy has an established role in diagnosis of cardiac amyloidosis (CA) as it detects transthyretin amyloidosis (ATTR). Positron emission tomography (PET) with amyloid tracers has shown high sensitivity for detection of both ATTR and light-chain (AL) CA. We aimed to investigate the accuracy of 18F-flutemetamol in CA. METHODS: We enrolled patients with CA or non-amyloid heart failure (NA-HF), who underwent cardiac 18F-flutemetamol PET/MRI or PET/CT. Myocardial and blood pool standardized tracer uptake values (SUV) were estimated. Late gadolinium enhancement (LGE) and T1 mapping/ extracellular volume (ECV) estimation were performed. RESULTS: We included 17 patients (12 with CA, 5 with NA-HF). PET/MRI was conducted in 13 patients, while PET/CT was conducted in 4. LGE was detected in 8 of 9 CA patients. Global relaxation time and ECV were higher in CA (1448 vs. 1326, P = 0.02 and 58.9 vs. 33.7%, P = 0.006, respectively). Positive PET studies were demonstrated in 2 of 12 patients with CA (AL and ATTR). Maximal and mean SUV did not differ between groups (2.21 vs. 1.69, P = 0.18 and 1.73 vs. 1.30, P = 0.13). CONCLUSION: Although protein-independent binding is supported by our results, the diagnostic yield of PET was low. We demonstrate here for the first time the low sensitivity of PET for CA.


Assuntos
Neuropatias Amiloides Familiares , Cardiomiopatias , Insuficiência Cardíaca , Amiloide , Neuropatias Amiloides Familiares/diagnóstico por imagem , Compostos de Anilina , Benzotiazóis , Cardiomiopatias/diagnóstico por imagem , Meios de Contraste , Gadolínio , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons
10.
Sensors (Basel) ; 22(14)2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-35891026

RESUMO

Digital histopathology poses several challenges such as label noise, class imbalance, limited availability of labelled data, and several latent biases to deep learning, negatively influencing transparency, reproducibility, and classification performance. In particular, biases are well known to cause poor generalization. Proposed tools from explainable artificial intelligence (XAI), bias detection, and bias discovery suffer from technical challenges, complexity, unintuitive usage, inherent biases, or a semantic gap. A promising XAI method, not studied in the context of digital histopathology is automated concept-based explanation (ACE). It automatically extracts visual concepts from image data. Our objective is to evaluate ACE's technical validity following design science principals and to compare it to Guided Gradient-weighted Class Activation Mapping (Grad-CAM), a conventional pixel-wise explanation method. To that extent, we created and studied five convolutional neural networks (CNNs) in four different skin cancer settings. Our results demonstrate that ACE is a valid tool for gaining insights into the decision process of histopathological CNNs that can go beyond explanations from the control method. ACE validly visualized a class sampling ratio bias, measurement bias, sampling bias, and class-correlated bias. Furthermore, the complementary use with Guided Grad-CAM offers several benefits. Finally, we propose practical solutions for several technical challenges. In contradiction to results from the literature, we noticed lower intuitiveness in some dermatopathology scenarios as compared to concept-based explanations on real-world images.


Assuntos
Inteligência Artificial , Neoplasias Cutâneas , Humanos , Redes Neurais de Computação , Reprodutibilidade dos Testes , Neoplasias Cutâneas/patologia
11.
Eur Radiol ; 31(4): 1795-1804, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32945971

RESUMO

OBJECTIVES: Body tissue composition is a long-known biomarker with high diagnostic and prognostic value not only in cardiovascular, oncological, and orthopedic diseases but also in rehabilitation medicine or drug dosage. In this study, the aim was to develop a fully automated, reproducible, and quantitative 3D volumetry of body tissue composition from standard CT examinations of the abdomen in order to be able to offer such valuable biomarkers as part of routine clinical imaging. METHODS: Therefore, an in-house dataset of 40 CTs for training and 10 CTs for testing were fully annotated on every fifth axial slice with five different semantic body regions: abdominal cavity, bones, muscle, subcutaneous tissue, and thoracic cavity. Multi-resolution U-Net 3D neural networks were employed for segmenting these body regions, followed by subclassifying adipose tissue and muscle using known Hounsfield unit limits. RESULTS: The Sørensen Dice scores averaged over all semantic regions was 0.9553 and the intra-class correlation coefficients for subclassified tissues were above 0.99. CONCLUSIONS: Our results show that fully automated body composition analysis on routine CT imaging can provide stable biomarkers across the whole abdomen and not just on L3 slices, which is historically the reference location for analyzing body composition in the clinical routine. KEY POINTS: • Our study enables fully automated body composition analysis on routine abdomen CT scans. • The best segmentation models for semantic body region segmentation achieved an averaged Sørensen Dice score of 0.9553. • Subclassified tissue volumes achieved intra-class correlation coefficients over 0.99.


Assuntos
Redes Neurais de Computação , Semântica , Abdome , Composição Corporal , Humanos , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X
12.
Eur Radiol ; 31(8): 6087-6095, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33630160

RESUMO

OBJECTIVES: To reduce the dose of intravenous iodine-based contrast media (ICM) in CT through virtual contrast-enhanced images using generative adversarial networks. METHODS: Dual-energy CTs in the arterial phase of 85 patients were randomly split into an 80/20 train/test collective. Four different generative adversarial networks (GANs) based on image pairs, which comprised one image with virtually reduced ICM and the original full ICM CT slice, were trained, testing two input formats (2D and 2.5D) and two reduced ICM dose levels (-50% and -80%). The amount of intravenous ICM was reduced by creating virtual non-contrast series using dual-energy and adding the corresponding percentage of the iodine map. The evaluation was based on different scores (L1 loss, SSIM, PSNR, FID), which evaluate the image quality and similarity. Additionally, a visual Turing test (VTT) with three radiologists was used to assess the similarity and pathological consistency. RESULTS: The -80% models reach an SSIM of > 98%, PSNR of > 48, L1 of between 7.5 and 8, and an FID of between 1.6 and 1.7. In comparison, the -50% models reach a SSIM of > 99%, PSNR of > 51, L1 of between 6.0 and 6.1, and an FID between 0.8 and 0.95. For the crucial question of pathological consistency, only the 50% ICM reduction networks achieved 100% consistency, which is required for clinical use. CONCLUSIONS: The required amount of ICM for CT can be reduced by 50% while maintaining image quality and diagnostic accuracy using GANs. Further phantom studies and animal experiments are required to confirm these initial results. KEY POINTS: • The amount of contrast media required for CT can be reduced by 50% using generative adversarial networks. • Not only the image quality but especially the pathological consistency must be evaluated to assess safety. • A too pronounced contrast media reduction could influence the pathological consistency in our collective at 80%.


Assuntos
Meios de Contraste , Aprendizado Profundo , Animais , Redução da Medicação , Humanos , Processamento de Imagem Assistida por Computador , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
13.
Eur J Nucl Med Mol Imaging ; 47(6): 1435-1445, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31811342

RESUMO

OBJECTIVES: The introduction of the 2016 WHO classification of CNS tumors has made the combined molecular and histopathological characterization of tumors a pivotal part of glioma patient management. Recent publications on radiogenomics-based prediction of the mutational status have demonstrated the predictive potential of imaging-based, non-invasive tissue characterization algorithms. Hence, the aim of this study was to assess the potential of multiparametric 18F-FET PET-MRI including MR fingerprinting accelerated with machine learning and radiomic algorithms to predict tumor grading and mutational status of patients with cerebral gliomas. MATERIALS AND METHODS: 42 patients with suspected primary brain tumor without prior surgical or systemic treatment or biopsy underwent an 18F-FET PET-MRI examination. To differentiate the mutational status and the WHO grade of the cerebral tumors, support vector machine and random forest were trained with the radiomics signature of the multiparametric PET-MRI data including MR fingerprinting. Surgical sampling served as a gold standard for histopathological reference and assessment of mutational status. RESULTS: The 5-fold cross-validated area under the curve in predicting the ATRX mutation was 85.1%, MGMT mutation was 75.7%, IDH1 was 88.7%, and 1p19q was 97.8%. The area under the curve of differentiating low-grade glioma vs. high-grade glioma was 85.2%. CONCLUSION: 18F-FET PET-MRI and MR fingerprinting enable high-quality imaging-based tumor decoding and phenotyping for differentiation of low-grade vs. high-grade gliomas and for prediction of the mutational status of ATRX, IDH1, and 1p19q. These initial results underline the potential of 18F-FET PET-MRI to serve as an alternative to invasive tissue characterization.


Assuntos
Neoplasias Encefálicas , Glioma , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/genética , Glioma/diagnóstico por imagem , Glioma/genética , Humanos , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Tirosina
14.
Eur J Nucl Med Mol Imaging ; 46(2): 437-445, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30074073

RESUMO

OBJECTIVES: To compare the diagnostic performance of 18F-FDG PET/MRI and 18F-FDG PET/CT for primary and locoregional lymph node staging in non-small cell lung cancer (NSCLC). METHODS: In this prospective study, a total of 84 patients (51 men, 33 women, mean age 62.5 ± 9.1 years) with histopathologically confirmed NSCLC underwent 18F-FDG PET/CT followed by 18F-FDG PET/MRI in a single injection protocol. Two readers independently assessed T and N staging in separate sessions according to the seventh edition of the American Joint Committee on Cancer staging manual for 18F-FDG PET/CT and 18F-FDG PET/MRI, respectively. Histopathology as a reference standard was available for N staging in all 84 patients and for T staging in 39 patients. Differences in staging accuracy were assessed by McNemars chi2 test. The maximum standardized uptake value (SUVmax) and longitudinal diameters of primary tumors were correlated using Pearson's coefficients. RESULTS: T stage was categorized concordantly in 18F-FDG PET/MRI and 18F-FDG PET/CT in 38 of 39 (97.4%) patients. Herein, 18F-FDG PET/CT and 18F-FDG PET/MRI correctly determined the T stage in 92.3 and 89.7% of patients, respectively. N stage was categorized concordantly in 83 of 84 patients (98.8%). 18F-FDG PET/CT correctly determined the N stage in 78 of 84 patients (92.9%), while 18F-FDG PET/MRI correctly determined the N stage in 77 of 84 patients (91.7%). Differences between 18F-FDG PET/CT and 18F-FDG PET/MRI in T and N staging accuracy were not statistically significant (p > 0.5, each). Tumor size and SUVmax measurements derived from both imaging modalities exhibited excellent correlation (r = 0.963 and r = 0.901, respectively). CONCLUSION: 18F-FDG PET/MRI and 18F-FDG PET/CT show an equivalently high diagnostic performance for T and N staging in patients suffering from NSCLC.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Tórax
15.
Langenbecks Arch Surg ; 404(4): 403-409, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30972487

RESUMO

BACKGROUND: Because adrenal angiomyelolipoma (AAML) is rare and uniformly benign, the indications for surgery are ill defined. METHODS: Among a series of 156 patients with adrenal pathologies surgically treated between 2013 and 2018, 12 patients were operated with the diagnosis of an AAML. The clinical as well as imaging parameters forming the individual indications for surgery were analyzed. RESULTS: Preoperative diagnosis consistent with AAML was made in all 12 patients. The mean size of surgically removed AAML was 82.3 mm (45-150 mm). Gender and affected side were evenly distributed. Local symptoms but lack of radiological signs suspicious for malignancy or size increase were observed in 4 of 12 patients (group 1, 33%). In contrast, 4 of 12 patients (group 2, 33%) showed radiological signs suspicious for malignancy but lacked local symptoms. Additional 4 of 12 patients (group 3, 33%) showed both local symptoms and radiological signs suspicious for malignancy. Patients with local symptoms harbored significantly larger tumors compared to those patients that lacked local symptoms (93.9 mm ± 32.8 vs. 59.3 mm ± 2.7, p = 0.021). Patients with radiologically suspicious signs were older (60 years ± 9.9 vs. 53 years ± 5.4, p > 0.05), and time to surgery was shorter (4.4 months ± 3 vs. 6.0 months ± 3.0, p > 0.05). Importantly, surgical approach was not influenced by tumor size (p = 0.65). However, patients with suspicious imaging were more likely to be operated by conventional open approach (4 of 8 vs. 0 of 4, p = 0.08). The minimal invasive approach was associated with shorter hospital stay (7 days, ± 1.3 vs. 14.2 days, ± 8.8, p = 0.038). All lesions that showed radiological signs suspicious for malignancy proved benign in final histology. CONCLUSION: Large AAML present a clinical challenge. The presence of local symptoms and/or radiological signs suspicious for malignancy identifies three groups of patients that define the concept of an individualized indication for surgery in AAML. A minimal invasive approach can be advocated even for large AAML with radiological signs suspicious for malignancy.


Assuntos
Neoplasias das Glândulas Suprarrenais/cirurgia , Angiomiolipoma/cirurgia , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Adrenalectomia , Adulto , Idoso , Angiomiolipoma/diagnóstico por imagem , Feminino , Humanos , Laparoscopia , Masculino , Pessoa de Meia-Idade
16.
Eur J Nucl Med Mol Imaging ; 45(8): 1382-1393, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29455313

RESUMO

PURPOSE: To evaluate the diagnostic performance of integrated whole-body positron emission tomography (PET)/magnetic resonance (MR) enterography in patients with Crohn's disease (CD). METHODS: Fifty patients with known CD and recurrent symptoms underwent ileocolonoscopy (reference standard) as well as PET/MR enterography. Seven ileocolonic segments were endoscopically analysed using the Simplified Endoscopic Activity Score for Crohn's Disease (SES-CD) and additionally classified into three categories of inflammation (none, mild to moderate and severe ulcerative inflammation). A total of 14 PET/MR parameters were applied for the assessment of inflamed segments. Contingency tables and the chi-squared test were used for the analysis of qualitative parameters, and the Mann-Whitney U test and receiver operating characteristic (ROC) curve for the analysis of quantitative parameters. The PET/MR parameters were ranked according to their diagnostic value by random forest classification. Correlations between PET/MR parameters and the severity of inflammation on endoscopy and SES-CD were tested using Spearman's rank correlation test. RESULTS: A total of 309 segments could be analysed. Based on multivariate regression analysis, wall thickness and the comb sign were the most important parameters for predicting segments with active inflammation of any type. SUVmax ratio of the bowel segment (relative to SUVmax of the liver) was the most important parameter for detecting segments with severe ulcerative inflammation. Wall thickness was the only parameter that moderately correlated with inflammation severity on endoscopy as well as with SES-CD (ρ = 0.56 and 0.589, both p < 0.001). CONCLUSION: PET/MR enterography is an excellent noninvasive diagnostic method, and both MR parameters and PET findings provided high accuracy in detecting inflamed segments.


Assuntos
Doença de Crohn/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Fluordesoxiglucose F18 , Humanos , Inflamação , Estudos Prospectivos
17.
Eur J Nucl Med Mol Imaging ; 45(12): 2147-2154, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29998420

RESUMO

PURPOSE: To compare the clinical performance of upper abdominal PET/DCE-MRI with and without concurrent respiratory motion correction (MoCo). METHODS: MoCo PET/DCE-MRI of the upper abdomen was acquired in 44 consecutive oncologic patients and compared with non-MoCo PET/MRI. SUVmax and MTV of FDG-avid upper abdominal malignant lesions were assessed on MoCo and non-MoCo PET images. Image quality was compared between MoCo DCE-MRI and non-MoCo CE-MRI, and between fused MoCo PET/MRI and fused non-MoCo PET/MRI images. RESULTS: MoCo PET resulted in higher SUVmax (10.8 ± 5.45) than non-MoCo PET (9.62 ± 5.42) and lower MTV (35.55 ± 141.95 cm3) than non-MoCo PET (38.11 ± 198.14 cm3; p < 0.005 for both). The quality of MoCo DCE-MRI images (4.73 ± 0.5) was higher than that of non-MoCo CE-MRI images (4.53±0.71; p = 0.037). The quality of fused MoCo-PET/MRI images (4.96 ± 0.16) was higher than that of fused non-MoCo PET/MRI images (4.39 ± 0.66; p < 0.005). CONCLUSION: MoCo PET/MRI provided qualitatively better images than non-MoCo PET/MRI, and upper abdominal malignant lesions demonstrated higher SUVmax and lower MTV on MoCo PET/MRI.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Abdome/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Movimento (Física)
18.
Eur Radiol ; 28(10): 4086-4101, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29717368

RESUMO

Positron emission tomography (PET) and magnetic resonance imaging (MRI) have both been used for decades in cardiovascular imaging. Since 2010, hybrid PET/MRI using sequential and integrated scanner platforms has been available, with hybrid cardiac PET/MR imaging protocols increasingly incorporated into clinical workflows. Given the range of complementary information provided by each method, the use of hybrid PET/MRI may be justified and beneficial in particular clinical settings for the evaluation of different disease entities. In the present joint position statement, we critically review the role and value of integrated PET/MRI in cardiovascular imaging, provide a technical overview of cardiac PET/MRI and practical advice related to the cardiac PET/MRI workflow, identify cardiovascular applications that can potentially benefit from hybrid PET/MRI, and describe the needs for future development and research. In order to encourage its wide dissemination, this article is freely accessible on the European Radiology and European Journal of Hybrid Imaging web sites. KEY POINTS: • Studies and case-reports indicate that PET/MRI is a feasible and robust technology. • Promising fields of application include a variety of cardiac conditions. • Larger studies are required to demonstrate its incremental and cost-effective value. • The translation of novel radiopharmaceuticals and MR-sequences will provide exciting new opportunities.


Assuntos
Técnicas de Imagem Cardíaca , Cardiopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Medicina Nuclear/métodos , Tomografia por Emissão de Pósitrons/métodos , Humanos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos
19.
J Nucl Cardiol ; 25(3): 785-794, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-27638745

RESUMO

OBJECTIVE: Besides cardiac sarcoidosis, FDG-PET is rarely used in the diagnosis of myocardial inflammation, while cardiac MRI (CMR) is the actual imaging reference for the workup of myocarditis. Using integrated PET/MRI in patients with suspected myocarditis, we prospectively compared FDG-PET to CMR and the feasibility of integrated FDG-PET/MRI in myocarditis. METHODS: A total of 65 consecutive patients with suspected myocarditis were prospectively assessed using integrated cardiac FDG-PET/MRI. Studies comprised T2-weighted imaging, late gadolinium enhancement (LGE), and simultaneous PET acquisition. Physiological glucose uptake in the myocardium was suppressed using dietary preparation. RESULTS: FDG-PET/MRI was successful in 55 of 65 enrolled patients: two patients were excluded due to claustrophobia and eight patients due to failed inhibition of myocardial glucose uptake. Compared with CMR (LGE and/or T2), sensitivity and specificity of PET was 74% and 97%. Overall spatial agreement between PET and CMR was κ = 0.73. Spatial agreement between PET and T2 (κ = 0.75) was higher than agreement between PET and LGE (κ = 0.64) as well as between LGE and T2 (κ = 0.56). CONCLUSION: In patients with suspected myocarditis, FDG-PET is in good agreement with CMR findings.


Assuntos
Fluordesoxiglucose F18 , Miocardite/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Adulto , Meios de Contraste , Estudos de Viabilidade , Feminino , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Masculino , Imagem Multimodal , Estudos Prospectivos
20.
J Nucl Cardiol ; 24(3): 980-988, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-26993494

RESUMO

OBJECTIVE: Assessment of increased glucose uptake in inflammatory or malignant myocardial disease using PET/MRI relies on uptake suppression in normal myocardium. We evaluated the efficacy of a ≥24 hours high-fat, low-carbohydrate, and protein-permitted diet (HFLCPP) in combination with unfractionated heparin for suppression of "physiologic" myocardial glucose uptake. METHODS: PET/MRI was successfully performed in 89 patients. HFLCPP was started ≥24 hours prior to PET/MRI. All patients received i.v. injection of unfractionated heparin (50 IU·kg-1) 15 minutes prior to FDG administration. Left ventricular FDG uptake was visually evaluated by two readers. Diffuse myocardial uptake exceeding liver uptake, isolated uptake in the lateral wall, or diffuse uptake in the entire circumference of the heart base were defined as failed suppression. Homogeneous myocardial uptake below liver uptake with/without focal uptake was defined as successful suppression. RESULTS: Success rate was 84%. Suppression was unsuccessful in 14 patients. No significant influence of gender (P = .40) or age (P = .21) was found. However, insufficient suppression was more common in patients younger than 45 years (20% vs 7%). PET/MR imaging completion rate was >97%. CONCLUSION: A HFLCPP diet in combination with unfractionated heparin was successfully implemented for cardiac PET/MRI and resulted in a sufficient suppression of myocardial FDG uptake in 84% of patients.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Dieta com Restrição de Carboidratos/métodos , Proteínas Alimentares/administração & dosagem , Fluordesoxiglucose F18/farmacocinética , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Miocárdio/metabolismo , Adulto , Jejum , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA