Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 365
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 43(10): 940-958, 2022 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-34624084

RESUMO

Intravascular thrombus formation and embolization are among the most frequent events leading to a number of cardiovascular conditions with high morbidity and mortality. The underlying causes are stasis of the circulating blood, genetic and acquired coagulation disorders, and reduced antithrombotic or prothrombotic properties of the vascular wall (Virchow's triad). In the venous system, intravascular thrombi can cause venous thrombosis and pulmonary and even peripheral embolism including ischaemic stroke [through a patent foramen ovale (PFO)]. Thrombi in the left atrium and its appendage or ventricle form in the context of atrial fibrillation and infarction, respectively. Furthermore, thrombi can form on native or prosthetic aortic valves, within the aorta (in particular at sites of ulcers, aortic dissection, and abdominal aneurysms), and in cerebral and peripheral arteries causing stroke and critical limb ischaemia, respectively. Finally, thrombotic occlusion may occur in arteries supplying vital organs such the heart, brain, kidney, and extremities. Thrombus formation and embolization can be managed with anticoagulants and devices depending on where they form and embolize and on patient characteristics. Vitamin K antagonists are preferred in patients with mechanical valves, while novel oral anticoagulants are first choice in most other cardiovascular conditions, in particular venous thromboembolism and atrial fibrillation. As anticoagulants are associated with a risk of bleeding, devices such as occluders of a PFO or the left atrial appendage are preferred in patients with an increased bleeding risk. Platelet inhibitors such as aspirin and/or P2Y12 antagonists are preferred in the secondary prevention of coronary artery disease, stroke, and peripheral artery disease either alone or in combination depending on the clinical condition. A differential and personalized use of anticoagulants, platelet inhibitors, and devices is recommended and reviewed in this article.


Assuntos
Fibrilação Atrial , Isquemia Encefálica , Forame Oval Patente , Acidente Vascular Cerebral , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Isquemia Encefálica/induzido quimicamente , Fibrinolíticos/uso terapêutico , Forame Oval Patente/complicações , Forame Oval Patente/tratamento farmacológico , Humanos , Inibidores da Agregação Plaquetária/uso terapêutico , Acidente Vascular Cerebral/prevenção & controle
2.
J Card Surg ; 37(4): 993-1001, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34967980

RESUMO

BACKGROUND: Uncomplicated Stanford Type B aortic dissection (un-TBAD) is characterized by a tear in the aorta distal to the left subclavian artery without ascending aorta and arch involvement. Optimized cardiovascular control (blood pressure and heart rate) is the current gold standard treatment according to current international guidelines. However, emerging evidence indicates that thoracic endovascular aortic repair (TEVAR) is both safe and effective in the treatment of un-TBAD with improved long-term survival outcomes in combination with optimal medical therapy (OMT) relative to OMT alone. However, the optimal timeframe for intervention is not entirely clarified. AIMS: This review critically addresses current state-of-the-art comparing TEVAR with OMT and corresponding clinical outcomes for un-TBAD based on timing of intervention. METHODS: We carried out a comprehensive literature search on multiple electronic databases including PUBMED and Scopus to collate all research evidence on timing of TEVAR in uncomplicated Type B aortic dissection. RESULTS: TEVAR has proven to be a safe and effective treatment for un-TBAD in combination with OMT through comparable survival outcomes, improved aortic remodeling, and relatively low periprocedural added risks. Though the timing of intervention remains controversial, it is becoming clear that performing TEVAR during the subacute phase of un-TBAD yields better outcomes compared to earlier and delayed (>90 days) intervention. CONCLUSIONS: Further research is required into both short- and long-term outcomes of TEVAR in addition to its optimal therapeutic window for un-TBAD. With stronger evidence, TEVAR is likely to be adopted as the gold-standard intervention for un-TBAD with definitive timeframe guidelines.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Torácica/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
J Card Surg ; 37(5): 1328-1339, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35191082

RESUMO

BACKGROUND: Uncomplicated type B aortic dissection (un-TBAD) has been managed conservatively with medical therapy to control the heart rate and blood pressure to limit disease progression, in addition to radiological follow-up. However, several trials and observational studies have investigated the use of thoracic endovascular aortic repair (TEVAR) in un-TBAD and suggested that TEVAR provides a survival benefit over medical therapy. Outcomes of TEVAR have also been linked with the timing of intervention. AIMS: The scope of this review is to collate and summarize all the evidence in the literature on the mid- and long-term outcomes of TEVAR in un-TBAD, confirming its superiority. We also aimed to investigate the relationship between the timing of TEVAR intervention and results. METHODS: We carried out a comprehensive literature search on multiple electronic databases including PubMed, Scopus, and EMBASE to collate and summarize all research evidence on the mid- and long-term outcomes of TEVAR in un-TBAD, as well as its relationship with intervention timing. RESULTS: TEVAR has proven to be a safe and effective tool in un-TBAD, offering superior mid- and long-term outcomes including all-cause and aorta-related mortality, aortic-specific adverse events, aortic remodeling, and need for reintervention. Additionally, performing TEVAR during the subacute phase of dissection seems to yield optimal results. CONCLUSION: The evidence demonstrating a survival advantage in favor TEVAR over medical therapy in un-TBAD means that with further research, particular trials and observational studies, TEVAR could become the gold-standard treatment option for un-TBAD patients.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/etiologia , Aneurisma da Aorta Torácica/etiologia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/métodos , Humanos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
J Card Surg ; 37(4): 987-992, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35083781

RESUMO

BACKGROUND: The use of thoracic endovascular aortic repair (TEVAR) for the management of uncomplicated type B aortic dissection (un-TBAD) remains controversial. There is a lack of consensus over whether pre-emptive TEVAR should be carried out in patients with un-TBAD at risk of progression to complicated TBAD. We present a review of current evidence and seek to suggest criteria where endovascular intervention in un-TBAD may prove beneficial relative to pharmacotherapy alone. METHODS AND MATERIALS: PubMed and Cochrane databases were searched using terms including: type B aortic dissection, risk factors, medical therapy, TEVAR, false lumen (FL) expansion, and mortality. Papers were selected based on title and abstract. RESULTS: Optimal medical therapy remains the mainstay treatment for patients with un-TBAD, however, patients with un-TBAD present with varying degrees of disease progression risk. Factors such as age, aortic morphology, history of connective tissue disorders, FL thrombosis, and aortic branch involvement may potentiate progression from un-TBAD to complicated TBAD. Short- and long-term outcomes associated with TEVAR for TBAD remain promising. CONCLUSION: Pre-emptive TEVAR may be beneficial in patients with un-TBAD presenting with the above factors, however, further prospective research into the optimal timing for TEVAR in un-TBAD is required.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Torácica/etiologia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
J Card Surg ; 37(12): 4256-4266, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36086999

RESUMO

OBJECTIVES: To evaluate the long-term outcomes of a conservative approach (with proximal aortic replacement with or without hemiarch replacement) versus an aggressive approach (with total aortic arch replacement) in the treatment of acute type A aortic dissection (ATAAD). METHODS: We performed a pooled analysis of Kaplan-Meier-derived individual patient data from studies with follow-up comparing the aforementioned approaches to treat patients with ATAAD. RESULTS: Eighteen studies met our eligibility criteria, comprising 5243 patients with follow-up (Conservative: 3676 patients; Aggressive: 1567 patients). We observed a statistically significant difference in overall survival favoring the aggressive approach (hazard ratios [HR] 0.86, 95% confidence interval [CI] 0.76-0.98, p = .022), but no statistically significant difference in the risk of reoperation (HR 0.89, 95% CI 0.66-1.2, p = .439) in the overall follow-up. Landmark analyses revealed that, in the first 3 months after the procedure, mortality rates were comparable between conservative and aggressive approaches (HR 1.04, 95% CI 0.88-1.24, p = .627), but the results beyond 3 months showed improved survival in patients undergoing the aggressive surgical procedure (HR 0.71, 95% CI 0.59-0.85, p < .001). The landmark analyses also revealed that, in the first 7 years after the procedure, reoperation rates were comparable between the approaches (HR 1.03, 95% CI 0.76-1.40, p = .848), but the results beyond 7 years showed a lower risk of reoperation in patients undergoing the aggressive surgical procedure (HR 0.10, 95% CI 0.01-0.75, p = .025). CONCLUSION: The aggressive approach seems to confer better long-term survival and lower risk of the need for reoperation in the follow-up of patients treated for ATAAD.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Humanos , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Doença Aguda , Estudos Retrospectivos , Dissecção Aórtica/cirurgia , Reoperação , Aneurisma da Aorta Torácica/cirurgia , Fatores de Risco , Aorta Torácica/cirurgia
6.
Eur Heart J ; 42(38): 3904-3916, 2021 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-34392353

RESUMO

The field of cardiac electrophysiology (EP) had adopted simple artificial intelligence (AI) methodologies for decades. Recent renewed interest in deep learning techniques has opened new frontiers in electrocardiography analysis including signature identification of diseased states. Artificial intelligence advances coupled with simultaneous rapid growth in computational power, sensor technology, and availability of web-based platforms have seen the rapid growth of AI-aided applications and big data research. Changing lifestyles with an expansion of the concept of internet of things and advancements in telecommunication technology have opened doors to population-based detection of atrial fibrillation in ways, which were previously unimaginable. Artificial intelligence-aided advances in 3D cardiac imaging heralded the concept of virtual hearts and the simulation of cardiac arrhythmias. Robotics, completely non-invasive ablation therapy, and the concept of extended realities show promise to revolutionize the future of EP. In this review, we discuss the impact of AI and recent technological advances in all aspects of arrhythmia care.


Assuntos
Inteligência Artificial , Fibrilação Atrial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Big Data , Eletrocardiografia , Humanos
7.
Int Heart J ; 63(4): 654-660, 2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-35831149

RESUMO

We aimed to evaluate whether the buddy balloon technique (BBT) is superior to the buddy wire technique (BWT) with regard to the accuracy of stent placement during percutaneous coronary intervention (PCI).We enrolled patients who had been identified with significant stent movement before the stent was dilated at five hospitals and were randomly converted to either the BBT or BWT technique. The primary endpoints were the incidence of technical success and major adverse cardiovascular events (cardiac death, myocardial infarction, target lesion revascularization, and in-stent restenosis) at 2 years of follow-up. The secondary endpoints were the contrast volume used for the procedure and the total procedural time.From August 2018 to July 2019, 66 patients were enrolled, with 33 patients in each group. All patients were successfully followed up to 2 years. At the primary endpoints, compared with patients treated using BWT, those in the BBT group showed significantly better technical success (93.94% versus 39.39%, respectively; P < 0.0001). There was no significant difference in the incidence of major cardiovascular adverse events (6.06% versus 12.12%, respectively; P = 0.392). At the secondary endpoints, the contrast volume used for the procedure was lower with BBT (85.97 ± 22.45 versus 115.00 ± 21.45 mL, respectively; P < 0.0001); similarly, the total procedural time was shorter with BBT (65.94 ± 12.14 versus 74.33 ± 15.36 minutes, respectively; P < 0.0001).BBT could better restrict stent movement and facilitate precise stent deployment, with significant superiority over BWT. In addition, BBT can reduce the procedural time and contrast dose.


Assuntos
Angioplastia Coronária com Balão , Intervenção Coronária Percutânea , Stents , Angioplastia Coronária com Balão/métodos , Angiografia Coronária , Reestenose Coronária/etiologia , Humanos , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Stents/efeitos adversos , Resultado do Tratamento
8.
J Endovasc Ther ; 28(1): 36-43, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32869716

RESUMO

PURPOSE: To evaluate the safety and feasibility of the in situ needle fenestration (ISNF) technique for reconstruction of the left subclavian artery (LSA) during thoracic endovascular aortic repair (TEVAR) of complicated aortic arch pathologies. MATERIALS AND METHODS: A retrospective review was conducted from January 2014 to December 2019 of 50 patients (mean age 60.2±11.1; 45 men) who underwent ISNF to revascularize the LSA during TEVAR. Twenty-one of the patients also required revascularization of the left common carotid artery (LCCA; n=19) and innominate artery (IA; n=2) using physician-modified in vitro fenestration. Overall, 73 supra-aortic branches were targeted for revascularization. RESULTS: ISNF was successful in 48 patients (96%); one LSA could not be stented and a tortuous LSA prevented the needle from fenestrating the graft. No perioperative major adverse event occurred. There were no type I and 4 type III endoleaks (8%), 3 of which occurred among the first 20 cases. Types II and IV endoleaks were found in 3 (6%) and 6 (12%) cases, respectively; all disappeared during a median follow-up of 15 months (range 3-66). One death (2%) occurred within 12 months due to cerebral hemorrhage. Two patients (4%) required open reinterventions at 6 and 62 months. CONCLUSION: ISNF for revascularization of the LSA during TEVAR seems to be feasible with acceptable midterm outcomes. The learning curve and evolving patient selection criteria affected technical success, complications, and the need for reinterventions. Long-term durability requires further evaluation.


Assuntos
Aorta Torácica , Procedimentos Endovasculares , Idoso , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/cirurgia , Resultado do Tratamento
9.
Cardiology ; 146(3): 335-344, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33780933

RESUMO

BACKGROUND: The 3-month period after hospitalization for acute cardiac failure is a vulnerable phase with the highest risk of mortality and rehospitalization. Safety and efficacy of early initiation of sacubitril/valsartan during the index hospitalization for acute decompensated heart failure (ADHF) is unclear. Therefore, we tested whether sacubitril/valsartan could result in a lower rate of a composite outcome of first hospitalization for heart failure and death from cardiovascular causes compared to inhibition of the renin-angiotensin system alone. METHODS: We enrolled patients hospitalized for ADHF and reduced ejection fraction at 4 sites; patients were divided into a sacubitril/valsartan group or an angiotensin-converting enzyme inhibitor (ACEI)/angiotensin receptor blocker (ARB) group. All patients were followed up for 3 months after discharge. The primary endpoint was outcomes as a composite of death from cardiovascular causes and rehospitalization for heart failure. RESULTS: In total, 251 patients who received sacubitril/valsartan and 251 patients who received ACEIs/ARBs had similar propensity scores and were included and compared. The primary endpoint was reached in 40 patients (15.9%) treated with sacubitril/valsartan and in 59 patients (23.5%) managed by ACEI/ARB (HR, 0.650; 95% CI: 0.435-0.971; p = 0.035). The NYHA class improved in 72.1% of patients in the sacubitril/valsartan group and in 59.8% of patients in the ACEI/ARB group (HR, 1.303; 95% CI: 1.097-1.548, p = 0.004). The key safety outcomes endpoints did not significantly differ. CONCLUSIONS: Among patients hospitalized with ADHF and reduced left ventricular ejection fraction, we observed that sacubitril/valsartan therapy led to reduction in death from cardiovascular causes and rehospitalizations for heart failure when compared to ACEI/ARB therapy alone during the vulnerable phase. Our results support that sacubitril/valsartan may be administered early in the vulnerable phase after ADHF and improves NYHA class.


Assuntos
Antagonistas de Receptores de Angiotensina , Insuficiência Cardíaca , Aminobutiratos , Antagonistas de Receptores de Angiotensina/efeitos adversos , Inibidores da Enzima Conversora de Angiotensina/efeitos adversos , Compostos de Bifenilo , Estudos de Coortes , Combinação de Medicamentos , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Estudos Prospectivos , Volume Sistólico , Tetrazóis/efeitos adversos , Resultado do Tratamento , Valsartana/efeitos adversos , Função Ventricular Esquerda
10.
Echocardiography ; 38(1): 31-38, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33146452

RESUMO

OBJECTIVE: In hypertension, indexes of midwall left ventricular (LV) function may identify patients at higher cardiovascular (CV) risk independent of normal LV ejection fraction (EF). We analyzed the association of baseline and new-onset LV midwall dysfunction with CV outcome in a large population of patients with asymptomatic aortic stenosis (AS). METHODS: One thousand four hundred seventy-eight patients with asymptomatic AS and normal EF (≥50%) at baseline in the Simvastatin Ezetimibe in Aortic Stenosis (SEAS) study were followed for a median of 4.3 years. LV systolic function was assessed by biplane EF and midwall shortening (MWS, low if <14% in men/16% in women) at baseline and annual echocardiographic examinations. RESULTS: One hundred twenty-three CV deaths and heart failure hospitalizations occurred during follow-up. In Cox analyses, adjusting for age, gender, body mass index, hypertension, EF, AS severity, LV hypertrophy and systemic arterial compliance, low baseline MWS predicted 61% higher risk of a major CV event and a twofold higher risk of death and heart failure hospitalization (P < .05). New-onset low MWS developed in 574 patients, particularly in elderly women with higher blood pressure and more severe AS (P < .05). In time-varying Cox analysis, new-onset low MWS was associated with a twofold higher risk of CV death and heart failure hospitalization, independent of changes over time in EF, AS severity, LV hypertrophy and systemic arterial compliance (P < .05). CONCLUSIONS: Low MWS develops in a large proportion of patients with AS and normal EF during valve disease progression and is a marker of increased CV risk.


Assuntos
Estenose da Valva Aórtica , Função Ventricular Esquerda , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Hipertrofia Ventricular Esquerda/complicações , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Masculino , Prognóstico , Sístole
11.
J Card Surg ; 35(12): 3467-3473, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32939836

RESUMO

BACKGROUND: Type A acute aortic dissection (TAAAD) represents a surgical emergency requiring intervention regardless of time of day. Whether such a "evening effect" exists regarding outcomes for TAAAD has not been previously studied using a large registry data. METHODS: Patients with TAAAD were identified from the International Registry of Acute Aortic Dissections (1996-2019). Outcomes were compared between patients undergoing operative repair during the daytime (D), defined as 8 am-5 pm, versus the evening (N), defined as 5 pm-8 am. RESULTS: Four thousand one-hundrd and ninety-seven surgically treated patients with TAAAD were identified, with 1824 patients undergoing daytime surgery (43.5%) and 2373 patients undergoing evening surgery (56.5%). Daytime patients were more likely to have undergone prior cardiac surgery (13.2% vs. 9.5%; p < .001) and have had a prior aortic dissection (4.8% vs. 3.4%; p = .04). Evening patients were more likely to have been transferred from a referring hospital (70.8% vs. 75.0%; p = .003). Daytime patients were more likely to undergo aortic valve sparing root procedures (23.3% vs. 19.2%; p = .035); however, total arch replacement was performed with equal frequency (19.4% vs. 18.8%; p = .751). In-hospital mortality (D: 17.3% vs. N. 16.2%; p = .325) was similar between both groups. Subgroup analysis examining the effect of weekend presentation revealed no significant mortality difference. CONCLUSIONS: A majority of TAAAD patients underwent surgical repair at night. There were higher rates of postoperative tamponade in evening patients; however, mortality was similar. The expertise of cardiac-dedicated operative and critical care teams regardless of time of day as well as training paradigms may explain similar mortality outcomes in this high risk population.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Doença Aguda , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Mortalidade Hospitalar , Humanos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
12.
Circulation ; 137(17): 1846-1860, 2018 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-29685932

RESUMO

Acute aortic dissection (AAD) is a life-threatening condition associated with high morbidity and mortality rates, and it remains a challenge to diagnose and treat. The International Registry of Acute Aortic Dissection was established in 1996 with the mission to raise awareness of this condition and provide insights to guide diagnosis and treatment. Since then, >7300 cases have been included from >51 sites in 12 countries. Although presenting symptoms and physical findings have not changed significantly over this period, the use of computed tomography in the diagnosis has increased, and more patients are managed with interventional procedures: surgery in type A AAD and endovascular therapy in type B AAD; with these changes in care, there has been a significant decrease in overall in-hospital mortality in type A AAD but not in type B AAD. Herein, we summarized the key lessons learned from this international registry of patients with AAD over the past 20 years.


Assuntos
Aneurisma Aórtico , Dissecção Aórtica , Doença Aguda , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Dissecção Aórtica/cirurgia , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Aneurisma Aórtico/cirurgia , Aortografia/métodos , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
13.
J Vasc Surg ; 70(4): 1072-1081.e2, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31147139

RESUMO

OBJECTIVE: We report the final 5-year results from the Study of Thoracic Aortic Type B Dissection Using Endoluminal Repair (STABLE I) study, a prospective, single-arm, multicenter study of the Zenith Dissection Endovascular System (William Cook Europe, Aps, Bjaeverskov, Denmark), a pathology-specific device comprising a proximal stent graft with barbs and a distal bare stainless steel stent for the treatment of patients with complicated type B aortic dissection. METHODS: The study prospectively enrolled 86 patients (mean age, 59 years; 73% male) at sites in the United States, Europe, and Australia from 2007 to 2012. Treatment occurred during the acute phase (≤14 days after symptom onset) in 55 patients and during the nonacute phase (>14 days; all treated ≤90 days) in 31 patients. Five-year clinical and imaging follow-up was available for 88.5% of eligible patients. RESULTS: The 30-day all-cause mortality rate was 5.5% (3 of 55) for acute and 3.2% (1 of 31) for nonacute patients (P > .99). The 5-year freedom from all-cause mortality was 79.9% ± 6.2% for acute and 70.1% ± 8.4% for nonacute patients (log-rank test, P = .40). The 5-year freedom from dissection-related mortality (including deaths of indeterminate relatedness to dissection repair) was 83.9% ± 5.9% for acute and 90.1% ± 5.9% for nonacute patients (log-rank test, P = .55). Complete false lumen thrombosis in the thoracic aorta increased over time and was observed in 74.1% of acute and in 58.8% of nonacute patients at 5 years. From preprocedure through 5 years, there was an overall increase in true lumen diameter and a concomitant decrease in false lumen diameter in both acute and nonacute patients at the level of the largest diameter in both the thoracic and abdominal aortas. At 5 years, 65.5% of acute and 81.3% of nonacute patients exhibited a stable or shrinking transaortic diameter in the thoracic aorta, and 48.3% of acute and 76.5% of nonacute patients had a stable or shrinking transaortic diameter in the abdominal aorta. Freedom from secondary intervention at 5 years was 65.5% ± 7.5% for acute and 71.2% ± 9.0% for nonacute patients (log-rank test, P = .71). CONCLUSIONS: Endovascular repair of complicated type B aortic dissection with a composite device design demonstrated low all-cause mortality at 30 days, as well as low dissection-related mortality throughout follow-up. Overall, the acute and nonacute cohorts appeared to respond similarly to treatment involving use of the stent-graft and bare metal stent, demonstrating similar clinical outcomes and favorable improvement in aortic remodeling in the thoracic and abdominal aortas.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Austrália , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Intervalo Livre de Progressão , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Estados Unidos
14.
Lipids Health Dis ; 18(1): 119, 2019 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-31122256

RESUMO

OBJECTIVES: The study sought to assess the impact of statin therapy on survival in patients presenting with ventricular tachyarrhythmias. BACKGROUND: Data regarding the outcome of patients with statin therapy presenting with ventricular tachyarrhythmias is limited. METHODS: A large retrospective registry was used including all consecutive patients presenting with ventricular tachycardia (VT) or fibrillation (VF) from 2002 to 2016. Patients with statin were compared to patients without statin therapy (non-statin). The primary prognostic endpoint was long-term all-cause death at 3 years. Uni- and multivariable Cox regression analyses were applied in propensity-score matched cohorts. RESULTS: A total of 424 matched patients was included. The rates of VT and VF were similar in both groups (VT: statin 71% vs. non-statin 68%; VF: statin 29% vs. 32%; p = 0.460). Statin therapy was associated with lower all-cause mortality at long-term follow-up (mortality rates 16% versus 33%; log rank, p = 0.001; HR = 0.438; 95% CI 0.290-0.663; p = 0.001), irrespective of the underlying type of ventricular tachyarrhythmia (VT/VF), left ventricular ejection fraction (LVEF) > 35%, presence of an activated implantable cardioverter defibrillator (ICD), cardiogenic shock or cardiopulmonary resuscitation (CPR). CONCLUSION: Statin therapy is independently associated with lower long-term mortality in patients presenting with ventricular tachyarrhythmias on admission. TRIAL REGISTRATION: Clinicaltrials.gov, NCT02982473 , 11/29/2016, Retrospectively registered.


Assuntos
Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Taquicardia Ventricular/tratamento farmacológico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Pontuação de Propensão , Modelos de Riscos Proporcionais , Análise de Sobrevida , Taquicardia Ventricular/mortalidade , Adulto Jovem
15.
Intern Med J ; 49(6): 711-721, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30479061

RESUMO

BACKGROUND: Ventricular tachyarrhythmias are still associated with poor clinical outcomes. Therefore, it is important to stratify high-risk patients presenting with ventricular tachyarrhythmias for their individual risk of future outcomes. AIM: To assess the impact of male sex on survival in patients presenting with ventricular tachyarrhythmias. METHODS: All consecutive patients surviving ventricular tachycardia (VT) and fibrillation (VF) on admission from 2002 to 2016 were included and stratified according to sex differences by propensity score matching. The primary prognostic end-point was all-cause mortality at 30 months. Secondary end-points were all-cause mortality at 30 days, at index hospitalisation, after discharge, the composite of recurrent ventricular tachyarrhythmias and appropriate implantable cardioverter defibrillator (ICD) therapies, and finally rehospitalisation related to ventricular tachyarrhythmias. RESULTS: A total of 784 (392 males and 392 females) matched patients was included. The rate of VT and VF was similar in both groups (VT: male 65% vs female 62%; VF: male 35% vs female 38%). Male sex was independently associated with the primary end-point of all-cause mortality at 30 months (31% vs 23%; hazard ratio (HR) = 1.432; 95% confidence interval (CI) 1.089-1.883; P = 0.010) as well as with the secondary end-point of all-cause mortality at index hospitalisation (mortality rate 31% vs 23%; log-rank P = 0.010; HR = 1.432; 95% CI 1.089-1.883; P = 0.010; mortality rate 10% vs 15%; HR = 1.685; 95% CI 1.117-2.542; P = 0.013). No differences in further secondary end-points were found. Sex differences of the primary end-point were predominantly observed in patients with VT at index (mortality rate 28% versus 20%; HR = 1.512; 95% CI 1.040-2.189; P = 0.028), without an ICD and with left ventricular ejection fraction ≥35% (log-rank values, P < 0.05). CONCLUSION: Males presenting with ventricular tachyarrhythmias on admission were associated with higher all-cause mortality at 30 months and all-cause mortality at index hospitalisation.


Assuntos
Fatores Sexuais , Taquicardia Ventricular/mortalidade , Fibrilação Ventricular/mortalidade , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Comorbidade , Desfibriladores Implantáveis , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Pontuação de Propensão , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fatores de Tempo , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia , Adulto Jovem
17.
J Vasc Surg ; 68(4): 956-964, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29602471

RESUMO

OBJECTIVE: The objective of this study was to assess the early and midterm outcomes of endovascular repair of complex aortic aneurysm cases using the Multilayer Flow Modulator (MFM; Cardiatis, Isnes, Belgium) endograft in Germany. METHODS: A retrospective study including patients presenting with abdominal aortic aneurysm (AAA), thoracic aortic aneurysm, or thoracoabdominal aortic aneurysm treated with the MFM was conducted in Germany. Mortality and morbidity (in terms of spinal cord ischemia, visceral ischemia, and stroke) at 30 days postoperatively were evaluated. In addition, during follow-up, freedom from reintervention, rupture, and failure mode were also assessed. RESULTS: Between 2009 and 2014, a total of 61 patients with AAA, thoracoabdominal aortic aneurysm, or thoracic aortic aneurysm were treated with the MFM endograft in 29 hospitals around Germany. However, data of 40 patients with a mean age of 73.4 ± 11.2 years (72.5% male; 29/40) and mean aortic aneurysm diameter of 60.3 ± 16.6 mm from 14 hospitals were available for this retrospective study. Thirty-seven (93%) patients were treated urgently. In 12 cases (12/40 [30%]), patients were treated outside instructions for use because of aortic aneurysm diameter >65 mm. A total of 69 MFM stents were used (1.7/patient). The technical success rate was 95% (38/40). Postoperatively, no patient presented with spinal cord ischemia, renal function deterioration, stroke, or intestinal ischemia, except for one patient who developed multiorgan failure because of early stent migration. The intraoperative and 30-day mortality rate was 0% and 2.5%, respectively. The mean follow-up was 12.9 months (±14.9 months), with a survival rate at 1 month, 6 months, and 12 months of 97%, 78%, and 70%, respectively. Freedom from failure mode (type I or II) at 1 month, 6 months, and 12 months was 97.5%, 88%, and 86%, respectively, and visceral vessel patency was 99.3% (155/156 available). During follow-up, 4 patients (4/39 [10%]) had an aneurysm sac rupture and 10 (10/39 [25%]) underwent a reintervention. Freedom from rupture and freedom from reintervention at 1 month, 6 months, and 12 months were 97.5% and 100%, 96% and 84%, and 86% and 75%, respectively. CONCLUSIONS: The use of the MFM for endovascular treatment of complex aortic aneurysm in urgent cases appears to be technically feasible in terms of mortality and morbidity, with moderate 30-day and acceptable midterm outcomes. Reinterventions may be needed to expand the utility of outcomes.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Intervalo Livre de Doença , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Estudos de Viabilidade , Feminino , Alemanha , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
18.
Catheter Cardiovasc Interv ; 92(4): 732-740, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29602262

RESUMO

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) has changed the management of aortic dissection by induced remodelling. Beyond reconstructing the true lumen, we describe the concept of False Lumen Intervention to promote Remodelling and Thrombosis (FLIRT) in both type A and B aortic dissection. METHODS: Between 2011 and 2017, 10 patients with aortic dissection (5 type A; 5 type B) underwent FLIRT using a combination of patent foramen ovale (PFO) or atrial septal defect (ASD) occluders, coils and glue. Patients were followed by computed tomography (CT) angiogram prior to, and 6 months following, discharge to evaluate false lumen (FL) thrombosis and aortic remodelling. Outcomes analyzed comprised successful device delivery, completeness of FL thrombosis and aortic remodelling, procedure related complications and mortality. RESULTS: FLIRT induced aortic remodelling in all cases of proximal dissection, with aortic shrinkage from 63.8 ± 7.5 pre-FLIRT, to 50.2 ± 6.6 mm (P = 0.057) and an increase in true lumen area from 5.8 ± 3.6 to 11.4 ± 2.5 cm2 (P = 0.006). In distal dissection (after previous TEVAR with residual FL flow), FLIRT successfully induced FL thrombosis in 4 of 5 cases at first attempt (1 case required additional coiling of the gutter between left subclavian artery and stent-graft for complete thrombosis). While maximal aortic diameter remained unchanged (55.6 ± 9.1 pre-FLIRT and 54.4 ± 13.7 mm at follow-up), true lumen area increased from 7.8 ± 2.3 pre-procedure, to 10.6 ± 1.5 cm2 at follow-up (P = 0.016), consistent with remodelling. CONCLUSION: Interventional FL management, using the FLIRT concept, is feasible in selected cases of aortic dissection, promotes FL thrombosis and induces successful remodelling.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Procedimentos Endovasculares , Trombose , Remodelação Vascular , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Dissecção Aórtica/fisiopatologia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Trombose/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
19.
BMC Cardiovasc Disord ; 18(1): 171, 2018 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-30126370

RESUMO

BACKGROUND: The interventional left atrial appendage closure (LAAC) is a guideline-conform alternative to oral anticoagulation (OAC) in non-valvular atrial fibrillation patients with OAC ineligibility. It was aimed to directly compare two contemporary devices in a real-world patient population. METHODS: LAAC was conducted in two centres between 2010 and 2014 as well as between 2014 and 2017, respectively, in a standard fashion based on the specific manufacturer's recommendations. Baseline characteristics, procedural data and event rates during intra-hospital and 6 months follow-up were registered in a retrospective approach, and analysed in device-related groups. RESULTS: A total of 189 patients presented for LAAC device implantation. Baseline characteristics were mostly evenly distributed. In 148 patients, a Watchman™ device (Boston Scientific, Natick, MA, USA) was successfully implanted, an Amplatzer™ Amulet™ (St. Jude Medical, St. Paul, MN, USA) in 34 patients (96.1 and 97.1%, respectively; p = 1.00). Major access site bleedings were more frequent in the Amplatzer™ Amulet™ group (8.9 versus 1.4%; p = 0.046). No intra-hospital thromboembolic event was present. During 6 months follow-up, peri-device leaks > 5 mm and thromboembolic events were uncommon (each p = n.s.). CONCLUSIONS: While procedural success was equally high with both contemporary devices, complications during follow-up were rare, and evenly distributed.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Transesofagiana , Desenho de Equipamento , Falha de Equipamento , Feminino , Alemanha , Humanos , Masculino , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
Circulation ; 134(6): 455-68, 2016 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-27486164

RESUMO

BACKGROUND: Evidence for treating hypertension in patients with asymptomatic aortic valve stenosis is scarce. We used data from the SEAS trial (Simvastatin Ezetimibe in Aortic Stenosis) to assess what blood pressure (BP) would be optimal. METHODS: A total of 1767 patients with asymptomatic aortic stenosis and no manifest atherosclerotic disease were analyzed. Outcomes were all-cause mortality, cardiovascular death, heart failure, stroke, myocardial infarction, and aortic valve replacement. BP was analyzed in Cox models as the cumulative average of serially measured BP and a time-varying covariate. RESULTS: The incidence of all-cause mortality was highest for average follow-up systolic BP ≥160 mm Hg (4.3 per 100 person-years; 95% confidence interval [CI], 3.1-6.0) and lowest for average systolic BP of 120 to 139 mm Hg (2.0 per 100 person-years; 95% CI, 1.6-2.6). In multivariable analysis, all-cause mortality was associated with average systolic BP <120 mm Hg (hazard ratio [HR], 3.4; 95% CI, 1.9-6.1), diastolic BP ≥90 mm Hg (HR, 1.8; 95% CI, 1.1-2.9), and pulse pressure <50 mm Hg (HR, 1.8; 95% CI, 1.1-2.9), with systolic BP of 120 to 139 mm Hg, diastolic BP of 70 to 79 mm Hg, and pulse pressure of 60 to 69 mm Hg taken as reference. Low systolic and diastolic BPs increased risk in patients with moderate aortic stenosis. With a time-varying systolic BP from 130 to 139 mm Hg used as reference, mortality was increased for systolic BP ≥160 mm Hg (HR, 1.7; P=0.033) and BP of 120 to 129 mm Hg (HR, 1.6; P=0.039). CONCLUSIONS: Optimal BP seems to be systolic BP of 130 to 139 mm Hg and diastolic BP of 70 to 90 mm Hg in these patients with asymptomatic aortic stenosis and no manifest atherosclerotic disease or diabetes mellitus. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00092677.


Assuntos
Anticolesterolemiantes/administração & dosagem , Estenose da Valva Aórtica/tratamento farmacológico , Pressão Sanguínea/efeitos dos fármacos , Ezetimiba/administração & dosagem , Hipertensão/tratamento farmacológico , Sinvastatina/administração & dosagem , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Pressão Sanguínea/fisiologia , Método Duplo-Cego , Seguimentos , Humanos , Hipertensão/diagnóstico por imagem , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA