Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Forensic Sci Int ; 309: 110183, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32097863

RESUMO

A round-robin test on the identification of GSR particles by SEM/EDX and involving eleven Institutes was conducted on a real sample, in order to evaluate the possibilities/limitations of using such sample to get additional information (compared to the analysis of the usual synthetic sample used within the framework of the ENFSI proficiency test) about the performances of the SEM/EDX systems. Each Institute was asked to analyse this sample following its own standard operating procedure, and by using all the systems in house, whenever available. Between each Institute, a check of the sample was performed by the organizing Institute (NICC), in order inter alia to monitor any degradation and/or contamination of the sample. A total of about 30 analyses were performed on the sample. For each particle of interest identified on the real sample, the detection effectiveness was monitored, as well as the classification allotted by each Institute. The Institutes were also asked to report some of their measurement parameters, and to send the results as they would have been communicated in their own case report. A quite good agreement was observed with regard to the classification of the particles of interest, since a broad consensus was reached for approximately 75% of these particles. A different classification risk exists for some classes, the barium/antimony classes being probably the most critical, as traces of lead may cause the particles to shift (or not) from the consistent with GSR upper-class to the characteristic of GSR upper-class; in the end, the decision to shift from one class to another strongly depends on local rules. At the end of the campaign, a survey sent to collect experience and lessons learned from this exercise showed that analysing a real sample definitively offers an added value, especially in terms of classification process (during the automatic run and when performing the manual review) of particles.

2.
J Forensic Sci ; 53(1): 162-7, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18005006

RESUMO

Within the framework of the ENFSI Expert Working Group "Firearms" a proficiency test on the detection and identification of GSR by energy-dispersive scanning electron microanalysis (SEM/EDX) is carried out in a 2 years term. The latest test was performed in 2005/2006 and was denoted as GSR2005. Seventy-five laboratories from 28 countries participated in this proficiency test and submitted in total 83 independent data-sets. The participating laboratories were requested to determine the total number of PbSbBa containing particles on a synthetic test sample following their own laboratory specific methods of automated GSR particle search and detection by SEM/EDX. Furthermore size and position of the detected particles had to be reported by the laboratories and were evaluated statistically. The results were compiled by means of z-scores according to the IUPAC and EURACHEM guidelines-assessing individual laboratory achievements (inter-laboratory) as well as intra-laboratory performance-and were compared to the results of the previous proficiency test run GSR2003 (1). The comparison shows that there is a noticeable improvement in the method's detection capability.

3.
J Forensic Sci ; 50(4): 877-82, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16078491

RESUMO

Within the framework of the ENFSI Expert Working Group "Firearms," every second year, a proficiency test on the detection and identification of GSR by SEM/EDX is carried out. This proficiency test is a development and extension of the previous proficiency test GSR2001. The test material was again designed by the organization panel and manufactured by an external company for SEM accessories. This time the participating laboratories were requested to determine the total number of PbSbBa containing particles on a test sample following their own laboratory specific methods of automated GSR particle search and detection by SEM/EDX. One synthetic particle sample (SPS) with artificial GSR particles was dispatched to all participants. This paper summarizes the results of the study and assesses the overall performance of the participating laboratories. Furthermore an extended statistical evaluation and a comparison with previous studies was carried out.

4.
Scanning ; 36(3): 362-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24170434

RESUMO

Precise patterning of inorganic materials is important for many technological applications. Often lithography processes are required on challenging substrates with respect to topography, flexibility, and surface adhesion. Here we show the fabrication of artificial gunshot residues (GSR) on adhesive tape samples by means of dip-pen lithography as an example for fine lithography on coarse substrates. We deposited lead-, barium-, and antimony-containing inks on SEM adhesive tape by direct writing with a fine tip. Single as well as multiple element structures with dimensions in the range of 10-75 µm were fabricated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA