Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Opt Soc Am A Opt Image Sci Vis ; 40(12): 2205-2214, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38086029

RESUMO

Optical properties of biological tissues, such as refractive index, are fundamental properties, intrinsically linked to a tissue's composition and structure. This study aims to investigate the variation of refractive index (RI) of human articular cartilage along the tissue depth (via collagen fibril orientation and optical density) and integrity (based on Mankin and Osteoarthritis Research Society International (OARSI) scores). The results show the relationship between RI and PG content (p=0.042), collagen orientation (p=0.037), and OARSI score (p=0.072). When taken into account, the outcome of this study suggests that the RI of healthy cartilage differs from that of pathological cartilage (p=0.072). This could potentially provide knowledge on how progressive tissue degeneration, such as osteoarthritis, affects changes in cartilage RI, which can, in turn, be used as a potential optical biomarker of tissue pathology.


Assuntos
Cartilagem Articular , Osteoartrite , Humanos , Cartilagem Articular/química , Cartilagem Articular/patologia , Refratometria/métodos , Osteoartrite/patologia , Colágeno/análise
2.
Molecules ; 27(3)2022 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-35164133

RESUMO

The aim of the study was to optimize preprocessing of sparse infrared spectral data. The sparse data were obtained by reducing broadband Fourier transform infrared attenuated total reflectance spectra of bovine and human cartilage, as well as of simulated spectral data, comprising several thousand spectral variables into datasets comprising only seven spectral variables. Different preprocessing approaches were compared, including simple baseline correction and normalization procedures, and model-based preprocessing, such as multiplicative signal correction (MSC). The optimal preprocessing was selected based on the quality of classification models established by partial least squares discriminant analysis for discriminating healthy and damaged cartilage samples. The best results for the sparse data were obtained by preprocessing using a baseline offset correction at 1800 cm-1, followed by peak normalization at 850 cm-1 and preprocessing by MSC.


Assuntos
Cartilagem/química , Processamento de Sinais Assistido por Computador , Animais , Bovinos , Feminino , Humanos , Masculino , Espectroscopia de Infravermelho com Transformada de Fourier
3.
Molecules ; 27(7)2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35408697

RESUMO

Preclassification of raw infrared spectra has often been neglected in scientific literature. Separating spectra of low spectral quality, due to low signal-to-noise ratio, presence of artifacts, and low analyte presence, is crucial for accurate model development. Furthermore, it is very important for sparse data, where it becomes challenging to visually inspect spectra of different natures. Hence, a preclassification approach to separate infrared spectra for sparse data is needed. In this study, we propose a preclassification approach based on Multiplicative Signal Correction (MSC). The MSC approach was applied on human and the bovine knee cartilage broadband Fourier Transform Infrared (FTIR) spectra and on a sparse data subset comprising of only seven wavelengths. The goal of the preclassification was to separate spectra with analyte-rich signals (i.e., cartilage) from spectra with analyte-poor (and high-matrix) signals (i.e., water). The human datasets 1 and 2 contained 814 and 815 spectra, while the bovine dataset contained 396 spectra. A pure water spectrum was used as a reference spectrum in the MSC approach. A threshold for the root mean square error (RMSE) was used to separate cartilage from water spectra for broadband and the sparse spectral data. Additionally, standard noise-to-ratio and principle component analysis were applied on broadband spectra. The fully automated MSC preclassification approach, using water as reference spectrum, performed as well as the manual visual inspection. Moreover, it enabled not only separation of cartilage from water spectra in broadband spectral datasets, but also in sparse datasets where manual visual inspection cannot be applied.


Assuntos
Luz , Água , Animais , Bovinos , Humanos , Análise de Componente Principal , Espectroscopia de Infravermelho com Transformada de Fourier/métodos
4.
Mater Today Bio ; 24: 100879, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38130429

RESUMO

Non-destructive assessments are required for the quality control of tissue-engineered constructs and the optimization of the tissue culture process. Near-infrared (NIR) spectroscopy coupled with machine learning (ML) provides a promising approach for such assessment. However, due to its nonspecific nature, each spectrum incorporates information on both neotissue and non-neotissue constituents of the construct; the effect of these constituents on the NIR-based assessments of tissue-engineered constructs has been overlooked in previous studies. This study investigates the effect of scaffolds, growth factors, and buffers on NIR-based assessments of tissue-engineered constructs. To determine if these non-neotissue constituents have a measurable effect on the NIR spectra of the constructs that can introduce bias in their assessment, nine ML algorithms were evaluated in classifying the NIR spectra of engineered cartilage according to the scaffold used to prepare the constructs, the growth factors added to the culture media, and the buffers used for storing the constructs. The effect of controlling for these constituents was also evaluated using controlled and uncontrolled NIR-based ML models for predicting tissue maturity as an example of neotissue-related properties of interest. Samples used in this study were prepared using norbornene-modified hyaluronic acid scaffolds with or without the conjugation of an N-cadherin mimetic peptide. Selected samples were supplemented with transforming growth factor-beta1 or bone morphogenetic protein-9 growth factor. Some samples were frozen in cell lysis buffer, while the remaining samples were frozen in PBS until required for NIR analysis. The ML models for classifying the spectra of the constructs according to the four constituents exhibited high to fair performances, with F1 scores ranging from 0.9 to 0.52. Moreover, controlling for the four constituents significantly improved the performance of the models for predicting tissue maturity, with improvement in F1 scores ranging from 0.09 to 0.77. In conclusion, non-neotissue constituents have measurable effects on the NIR spectra of tissue-engineered constructs that can be detected by ML algorithms and introduce bias in the assessment of the constructs by NIR spectroscopy. Therefore, controlling for these constituents is necessary for reliable NIR-based assessments of tissue-engineered constructs.

5.
J Biomech ; 169: 112135, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38744145

RESUMO

Articular cartilage exhibits site-specific biomechanical properties. However, no study has comprehensively characterized site-specific cartilage properties from the same knee joints at different stages of osteoarthritis (OA). Cylindrical osteochondral explants (n = 381) were harvested from donor-matched lateral and medial tibia, lateral and medial femur, patella, and trochlea of cadaveric knees (N = 17). Indentation test was used to measure the elastic and viscoelastic mechanical properties of the samples, and Osteoarthritis Research Society International (OARSI) grading system was used to categorize the samples into normal (OARSI 0-1), early OA (OARSI 2-3), and advanced OA (OARSI 4-5) groups. OA-related changes in cartilage mechanical properties were site-specific. In the lateral and medial tibia and trochlea sites, equilibrium, instantaneous and dynamic moduli were higher (p < 0.001) in normal tissue than in early and advanced OA tissue. In lateral and medial femur, equilibrium, instantaneous and dynamic moduli were smaller in advanced OA, but not in early OA, than in normal tissue. The phase difference (0.1-0.25 Hz) between stress and strain was significantly smaller (p < 0.05) in advanced OA than in normal tissue across all sites except medial tibia. Our results indicated that in contrast to femoral and patellar cartilage, equilibrium, instantaneous and dynamic moduli of the tibia and trochlear cartilage decreased in early OA. These may suggest that the tibia and trochlear cartilage degrades faster than the femoral and patellar cartilage. The information is relevant for developing site-specific computational models and engineered cartilage constructs.


Assuntos
Cartilagem Articular , Articulação do Joelho , Osteoartrite do Joelho , Humanos , Cartilagem Articular/fisiopatologia , Cartilagem Articular/fisiologia , Cartilagem Articular/patologia , Articulação do Joelho/fisiopatologia , Idoso , Osteoartrite do Joelho/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Fenômenos Biomecânicos , Elasticidade , Viscosidade , Tíbia/fisiopatologia , Fêmur/fisiopatologia , Fêmur/fisiologia , Idoso de 80 Anos ou mais , Adulto , Estresse Mecânico
6.
Ann Biomed Eng ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38902468

RESUMO

In order to improve the ability of clinical diagnosis to differentiate articular cartilage (AC) injury of different origins, this study explores the sensitivity of mid-infrared (MIR) spectroscopy for detecting structural, compositional, and functional changes in AC resulting from two injury types. Three grooves (two in parallel in the palmar-dorsal direction and one in the mediolateral direction) were made via arthrotomy in the AC of the radial facet of the third carpal bone (middle carpal joint) and of the intermediate carpal bone (the radiocarpal joint) of nine healthy adult female Shetland ponies (age = 6.8 ± 2.6 years; range 4-13 years) using blunt and sharp tools. The defects were randomly assigned to each of the two joints. Ponies underwent a 3-week box rest followed by 8 weeks of treadmill training and 26 weeks of free pasture exercise before being euthanized for osteochondral sample collection. The osteochondral samples underwent biomechanical indentation testing, followed by MIR spectroscopic assessment. Digital densitometry was conducted afterward to estimate the tissue's proteoglycan (PG) content. Subsequently, machine learning models were developed to classify the samples to estimate their biomechanical properties and PG content based on the MIR spectra according to injury type. Results show that MIR is able to discriminate healthy from injured AC (91%) and between injury types (88%). The method can also estimate AC properties with relatively low error (thickness = 12.7% mm, equilibrium modulus = 10.7% MPa, instantaneous modulus = 11.8% MPa). These findings demonstrate the potential of MIR spectroscopy as a tool for assessment of AC integrity changes that result from injury.

7.
J Pers Med ; 13(7)2023 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-37511649

RESUMO

Mid-infrared spectroscopy (MIR), near-infrared spectroscopy (NIR), and Raman spectroscopy are all well-established analytical techniques in biomedical applications. Since they provide complementary chemical information, we aimed to determine whether combining them amplifies their strengths and mitigates their weaknesses. This study investigates the feasibility of the fusion of MIR, NIR, and Raman spectroscopic data for characterising articular cartilage integrity. Osteochondral specimens from bovine patellae were subjected to mechanical and enzymatic damage, and then MIR, NIR, and Raman data were acquired from the damaged and control specimens. We assessed the capacity of individual spectroscopic methods to classify the samples into damage or control groups using Partial Least Squares Discriminant Analysis (PLS-DA). Multi-block PLS-DA was carried out to assess the potential of data fusion by combining the dataset by applying two-block (MIR and NIR, MIR and Raman, NIR and Raman) and three-block approaches (MIR, NIR, and Raman). The results of the one-block models show a higher classification accuracy for NIR (93%) and MIR (92%) than for Raman (76%) spectroscopy. In contrast, we observed the highest classification efficiency of 94% and 93% for the two-block (MIR and NIR) and three-block models, respectively. The detailed correlative analysis of the spectral features contributing to the discrimination in the three-block models adds considerably more insight into the molecular origin of cartilage damage.

8.
Biomed Opt Express ; 14(7): 3397-3412, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37497494

RESUMO

There is increasing research on the potential application of diffuse optical spectroscopy and hyperspectral imaging for characterizing the health of the connective tissues, such as articular cartilage, during joint surgery. These optical techniques facilitate the rapid and objective diagnostic assessment of the tissue, thus providing unprecedented information toward optimal treatment strategy. Adaption of optical techniques for diagnostic assessment of musculoskeletal disorders, including osteoarthritis, requires precise determination of the optical properties of connective tissues such as articular cartilage. As every indirect method of tissue optical properties estimation consists of a measurement step followed by a computational analysis step, there are parameters associated with these steps that could influence the estimated values of the optical properties. In this study, we report the absorption and reduced scattering coefficients of articular cartilage in the spectral band of 400-1400 nm. We assess the impact of the experimental setup parameters, including surrounding medium, sample volume, and scattering anisotropy factor on the reported optical properties. Our results suggest that the absorption coefficient of articular cartilage is sensitive to the variation in the surrounding medium, whereas its reduced scattering coefficient is invariant to the experimental setup parameters.

9.
Sci Rep ; 13(1): 11928, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37488233

RESUMO

Among numerous approaches to the study of migraine, the nitroglycerin (NTG) model occupies a prominent place, but there is relatively insufficient information about how NTG affects intracranial vessels. In this study we aim to assess the effects of NTG on blood-flow parameters in meningeal vessels measured by imaging photoplethysmography (iPPG) in animal experiments. An amplitude of the pulsatile component (APC) of iPPG waveform was assessed before and within 2.5 h after the NTG administration in saline (n = 13) or sumatriptan (n = 12) pretreatment anesthetized rats in conditions of a closed cranial window. In animals of both groups, NTG caused a steady decrease in blood pressure. In 7 rats of the saline group, NTG resulted in progressive increase in APC, whereas decrease in APC was observed in other 6 rats. In all animals in the sumatriptan group, NTG administration was accompanied exclusively by an increase in APC. Diametrically opposite changes in APC due to NTG indicate a dual effect of this drug on meningeal vasomotor activity. Sumatriptan acts as a synergist of the NTG vasodilating action. The results we obtained contribute to understanding the interaction of vasoactive drugs in the study of the headache pathophysiology and methods of its therapy.


Assuntos
Transtornos de Enxaqueca , Nitroglicerina , Ratos , Animais , Nitroglicerina/farmacologia , Nitroglicerina/uso terapêutico , Sumatriptana/farmacologia , Sumatriptana/uso terapêutico , Vasodilatadores/farmacologia , Vasodilatadores/uso terapêutico , Fotopletismografia , Transtornos de Enxaqueca/tratamento farmacológico
10.
Ann Biomed Eng ; 51(10): 2301-2312, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37328704

RESUMO

OBJECTIVE: To differentiate healthy from artificially degraded articular cartilage and estimate its structural, compositional, and functional properties using Raman spectroscopy (RS). DESIGN: Visually normal bovine patellae (n = 12) were used in this study. Osteochondral plugs (n = 60) were prepared and artificially degraded either enzymatically (via Collagenase D or Trypsin) or mechanically (via impact loading or surface abrasion) to induce mild to severe cartilage damage; additionally, control plugs were prepared (n = 12). Raman spectra were acquired from the samples before and after artificial degradation. Afterwards, reference biomechanical properties, proteoglycan (PG) content, collagen orientation, and zonal (%) thickness of the samples were measured. Machine learning models (classifiers and regressors) were then developed to discriminate healthy from degraded cartilage based on their Raman spectra and to predict the aforementioned reference properties. RESULTS: The classifiers accurately categorized healthy and degraded samples (accuracy = 86%), and successfully discerned moderate from severely degraded samples (accuracy = 90%). On the other hand, the regression models estimated cartilage biomechanical properties with reasonable error (≤ 24%), with the lowest error observed in the prediction of instantaneous modulus (12%). With zonal properties, the lowest prediction errors were observed in the deep zone, i.e., PG content (14%), collagen orientation (29%), and zonal thickness (9%). CONCLUSION: RS is capable of discriminating between healthy and damaged cartilage, and can estimate tissue properties with reasonable errors. These findings demonstrate the clinical potential of RS.


Assuntos
Cartilagem Articular , Animais , Bovinos , Análise Espectral Raman , Colágeno/metabolismo , Proteoglicanas , Aprendizado de Máquina
11.
J Biomed Opt ; 28(12): 125003, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38094709

RESUMO

Significance: Articular cartilage exhibits a zonal architecture, comprising three distinct zones: superficial, middle, and deep. Collagen fibers, being the main solid constituent of articular cartilage, exhibit unique angular and size distribution in articular cartilage zones. There is a gap in knowledge on how the unique properties of collagen fibers across articular cartilage zones affect the scattering properties of the tissue. Aim: This study hypothesizes that the structural properties of articular cartilage zones affect its scattering parameters. We provide scattering coefficient and scattering anisotropy factor of articular cartilage zones in the spectral band of 400 to 1400 nm. We enumerate the differences and similarities of the scattering properties of articular cartilage zones and provide reasoning for these observations. Approach: We utilized collimated transmittance and integrating sphere measurements to estimate the scattering coefficients of bovine articular cartilage zones and bulk tissue. We used the relationship between the scattering coefficients to estimate the scattering anisotropy factor. Polarized light microscopy was applied to estimate the depth-wise angular distribution of collagen fibers in bovine articular cartilage. Results: We report that the Rayleigh scatterers contribution to the scattering coefficients, the intensity of the light scattered by the Rayleigh and Mie scatterers, and the angular distribution of collagen fibers across tissue depth are the key parameters that affect the scattering properties of articular cartilage zones and bulk tissue. Our results indicate that in the short visible region, the superficial and middle zones of articular cartilage affect the scattering properties of the tissue, whereas in the far visible and near-infrared regions, the articular cartilage deep zone determines articular cartilage scattering properties. Conclusion: This study provides scattering properties of articular cartilage zones. Such findings support future research to utilize optical simulation to estimate the penetration depth, depth-origin, and pathlength of light in articular cartilage for optical diagnosis of the tissue.


Assuntos
Cartilagem Articular , Colágeno , Animais , Bovinos , Colágeno/química , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/química , Matriz Extracelular/química , Microscopia de Polarização , Anisotropia
12.
Ann Biomed Eng ; 51(10): 2245-2257, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37332006

RESUMO

Osteoarthritis degenerates cartilage and impairs joint function. Early intervention opportunities are missed as current diagnostic methods are insensitive to early tissue degeneration. We investigated the capability of visible light-near-infrared spectroscopy (Vis-NIRS) to differentiate normal human cartilage from early osteoarthritic one. Vis-NIRS spectra, biomechanical properties and the state of osteoarthritis (OARSI grade) were quantified from osteochondral samples harvested from different anatomical sites of human cadaver knees. Two support vector machines (SVM) classifiers were developed based on the Vis-NIRS spectra and OARSI scores. The first classifier was designed to distinguish normal (OARSI: 0-1) from general osteoarthritic cartilage (OARSI: 2-5) to check the general suitability of the approach yielding an average accuracy of 75% (AUC = 0.77). Then, the second classifier was designed to distinguish normal from early osteoarthritic cartilage (OARSI: 2-3) yielding an average accuracy of 71% (AUC = 0.73). Important wavelength regions for differentiating normal from early osteoarthritic cartilage were related to collagen organization (wavelength region: 400-600 nm), collagen content (1000-1300 nm) and proteoglycan content (1600-1850 nm). The findings suggest that Vis-NIRS allows objective differentiation of normal and early osteoarthritic tissue, e.g., during arthroscopic repair surgeries.


Assuntos
Cartilagem Articular , Osteoartrite , Humanos , Cartilagem Articular/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho , Articulação do Joelho/diagnóstico por imagem , Colágeno
13.
Opt Express ; 20(13): 13692-701, 2012 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-22714435

RESUMO

We present novel experimental method for estimation of the light penetration depth (LPD) in turbid media based on the analysis of the speckle pattern structure. Under the certain illumination conditions this structure is strongly dependent on the penetration depth. Presented theoretical model based on the Bragg diffraction from the thick holograms allows LPD estimation if only one parameter of the material, namely refractive index, of the material is known. Feasibility of the method was checked experimentally. Experimental results obtained for variety of the materials are in good agreement with the theoretical assumptions. It was shown that qualitative LPD comparison does not require knowledge of the material properties.


Assuntos
Misturas Complexas/química , Lasers , Modelos Químicos , Nefelometria e Turbidimetria/métodos , Refratometria/métodos , Simulação por Computador , Luz , Espalhamento de Radiação
14.
Appl Opt ; 51(11): 1781-7, 2012 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-22505170

RESUMO

We present a novel method for small surface defect detection based on the spatially filtered dynamic speckles. This method possesses high fidelity and versatility. Factors defining resolution of the proposed method is estimated and it is shown that resolution depends solely on the geometrical parameters of the optical system. Experimental results demonstrate feasibility of the proposed method for surface defect detection and are in good agreement with the theoretical estimations. A prototype for online detection of the defects with diameter of 400 µm is presented. Ways to improve prototype performance and the method resolution are discussed.

15.
Ann Biomed Eng ; 50(9): 1134-1142, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35802206

RESUMO

Injuries to the ligaments of the knee commonly impact vulnerable and physically active individuals. These injuries can lead to the development of degenerative diseases such as post-traumatic osteoarthritis (PTOA). Non-invasive optical modalities, such as infrared and Raman spectroscopy, provide means for quantitative evaluation of knee joint tissues and have been proposed as potential quantitative diagnostic tools for arthroscopy. In this study, we evaluate Raman spectroscopy as a viable tool for estimating functional properties of collateral ligaments. Artificial trauma was induced by anterior cruciate ligament transection (ACLT) in the left or right knee joint of skeletally mature New Zealand rabbits. The corresponding contralateral (CL) samples were extracted from healthy unoperated joints along with a separate group of control (CNTRL) animals. The rabbits were sacrificed at 8 weeks after ACLT. The ligaments were then harvested and measured using Raman spectroscopy. A uniaxial tensile stress-relaxation testing protocol was adopted for determining several biomechanical properties of the samples. Partial least squares (PLS) regression models were then employed to correlate the spectral data with the biomechanical properties. Results show that the capacity of Raman spectroscopy for estimating the biomechanical properties of the ligament samples varies depending on the target property, with prediction error ranging from 15.78% for tissue cross-sectional area to 30.39% for stiffness. The hysteresis under cyclic loading at 2 Hz (RMSE = 6.22%, Normalized RMSE = 22.24%) can be accurately estimated from the Raman data which describes the viscous damping properties of the tissue. We conclude that Raman spectroscopy has the potential for non-destructively estimating ligament biomechanical properties in health and disease, thus enhancing the diagnostic value of optical arthroscopic evaluations of ligament integrity.


Assuntos
Lesões do Ligamento Cruzado Anterior , Análise Espectral Raman , Animais , Ligamento Cruzado Anterior , Fenômenos Biomecânicos , Articulação do Joelho , Coelhos
16.
Nat Protoc ; 16(2): 1297-1329, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33462441

RESUMO

Near-infrared (NIR) spectroscopy is a powerful analytical method for rapid, non-destructive and label-free assessment of biological materials. Compared to mid-infrared spectroscopy, NIR spectroscopy excels in penetration depth, allowing intact biological tissue assessment, albeit at the cost of reduced molecular specificity. Furthermore, it is relatively safe compared to Raman spectroscopy, with no risk of laser-induced photothermal damage. A typical NIR spectroscopy workflow for biological tissue characterization involves sample preparation, spectral acquisition, pre-processing and analysis. The resulting spectrum embeds intrinsic information on the tissue's biomolecular, structural and functional properties. Here we demonstrate the analytical power of NIR spectroscopy for exploratory and diagnostic applications by providing instructions for acquiring NIR spectra, maps and images in biological tissues. By adapting and extending this protocol from the demonstrated application in connective tissues to other biological tissues, we expect that a typical NIR spectroscopic study can be performed by a non-specialist user to characterize biological tissues in basic research or clinical settings. We also describe how to use this protocol for exploratory study on connective tissues, including differentiating among ligament types, non-destructively monitoring changes in matrix formation during engineered cartilage development, mapping articular cartilage proteoglycan content across bovine patella and spectral imaging across the depth-wise zones of articular cartilage and subchondral bone. Depending on acquisition mode and experiment objectives, a typical exploratory study can be completed within 6 h, including sample preparation and data analysis.


Assuntos
Tecido Conjuntivo/metabolismo , Tecido Conjuntivo/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Animais , Cartilagem Articular/química , Células do Tecido Conjuntivo/citologia , Humanos , Proteoglicanas/química , Manejo de Espécimes/métodos
17.
Biomed Opt Express ; 12(10): 6066-6080, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34745722

RESUMO

Optical properties of biological tissues in the NIR spectral range have demonstrated significant potential for in vivo diagnostic applications and are critical parameters for modelling light interaction in biological tissues. This study aims to investigate the optical properties of articular cartilage as a function of tissue depth and integrity. The results suggest consistent wavelength-dependent variation in optical properties between cartilage depth-wise zones, as well as between healthy and degenerated tissue. Also, statistically significant differences (p<0.05) in both optical properties were observed between the different cartilage depth-wise zones and as a result of tissue degeneration. When taken into account, the outcome of this study could enable accurate modelling of light interaction in cartilage matrix and could provide useful diagnostic information on cartilage integrity.

18.
Cartilage ; 13(2_suppl): 285S-294S, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33615831

RESUMO

OBJECTIVE: Joint injuries may lead to degeneration of cartilage tissue and initiate development of posttraumatic osteoarthritis. Arthroscopic surgeries can be used to treat joint injuries, but arthroscopic evaluation of articular cartilage quality is subjective. Fourier transform infrared spectroscopy combined with fiber optics and attenuated total reflectance crystal could be used for the assessment of tissue quality during arthroscopy. We hypothesize that fiber-optic mid-infrared spectroscopy can detect enzymatically and mechanically induced damage similar to changes occurring during progression of osteoarthritis. DESIGN: Bovine patellar cartilage plugs were extracted and degraded enzymatically and mechanically. Adjacent untreated samples were utilized as controls. Enzymatic degradation was done using collagenase and trypsin enzymes. Mechanical damage was induced by (1) dropping a weight impactor on the cartilage plugs and (2) abrading the cartilage surface with a rotating sandpaper. Fiber-optic mid-infrared spectroscopic measurements were conducted before and after treatments, and spectral changes were assessed with random forest, partial least squares discriminant analysis, and support vector machine classifiers. RESULTS: All models had excellent classification performance for detecting the different enzymatic and mechanical damage on cartilage matrix. Random forest models achieved accuracies between 90.3% and 77.8%, while partial least squares model accuracies ranged from 95.8% to 84.7%, and support vector machine accuracies from 91.7% to 80.6%. CONCLUSIONS: The results suggest that fiber-optic Fourier transform infrared spectroscopy attenuated total reflectance spectroscopy is a viable way to detect minor and major degeneration of articular cartilage. Objective measures provided by fiber-optic spectroscopic methods could improve arthroscopic evaluation of cartilage damage.


Assuntos
Doenças das Cartilagens , Cartilagem Articular , Osteoartrite , Animais , Cartilagem Articular/metabolismo , Bovinos , Análise dos Mínimos Quadrados , Osteoartrite/diagnóstico por imagem , Osteoartrite/metabolismo , Espectroscopia de Infravermelho com Transformada de Fourier/métodos
19.
J Orthop Res ; 39(11): 2363-2375, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33368588

RESUMO

This study aimed to quantify the long-term progression of blunt and sharp cartilage defects and their effect on joint homeostasis and function of the equine carpus. In nine adult Shetland ponies, the cartilage in the radiocarpal and middle carpal joint of one front limb was grooved (blunt or sharp randomized). The ponies were subjected to an 8-week exercise protocol and euthanized at 39 weeks. Structural and compositional alterations in joint tissues were evaluated in vivo using serial radiographs, synovial biopsies, and synovial fluid samples. Joint function was monitored by quantitative gait analysis. Macroscopic, microscopic, and biomechanical evaluation of the cartilage and assessment of subchondral bone parameters were performed ex vivo. Grooved cartilage showed higher OARSI microscopy scores than the contra-lateral sham-operated controls (p < 0.0001). Blunt-grooved cartilage scored higher than sharp-grooved cartilage (p = 0.007) and fixed charge density around these grooves was lower (p = 0.006). Equilibrium and instantaneous moduli trended lower in grooved cartilage than their controls (significant for radiocarpal joints). Changes in other tissues included a threefold to sevenfold change in interleukin-6 expression in synovium from grooved joints at week 23 (p = 0.042) and an increased CPII/C2C ratio in synovial fluid extracted from blunt-grooved joints at week 35 (p = 0.010). Gait analysis outcome revealed mild, gradually increasing lameness. In conclusion, blunt and, to a lesser extent, sharp grooves in combination with a period of moderate exercise, lead to mild degeneration in equine carpal cartilage over a 9-month period, but the effect on overall joint health remains limited.


Assuntos
Articulações do Carpo , Doenças das Cartilagens , Cartilagem Articular , Doenças dos Cavalos , Animais , Articulações do Carpo/diagnóstico por imagem , Doenças das Cartilagens/patologia , Cartilagem Articular/patologia , Cavalos , Líquido Sinovial/metabolismo , Membrana Sinovial/patologia
20.
Opt Express ; 18(22): 23394-405, 2010 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-21164681

RESUMO

Performance of recently proposed multispectral imaging system for fast acquisition of two dimensional distribution of reflectance spectrum is experimentally studied. The system operation is based on a subspace vector model in which any reflectance spectrum is described in the compressed form as a linear combination of few spectral functions. A key element of the proposed system is a light source which includes a set of light-emitting diodes with different central wavelengths. The light source provides illumination of the object by fast-switchable sequences of spectral bands whose energy distributions are proportional to mutually orthogonal spectral functions (calculated in-advance). Object illumination is synchronized with a monochrome digital camera. The system allows us fast acquisition of reflectance spectra in a compressed form with high spatial resolution. A model of the system calibration by using standard white matte sample is proposed. Reconstruction of the reflectance spectrum from the compressed data collected after illumination of selected color samples from the Munsell book by 7 mutually orthogonal spectral functions is demonstrated. Parameters of the system, which affect the accuracy of the spectrum reconstruction, are analyzed and discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA