Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Allergy ; 77(1): 243-257, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34496033

RESUMO

BACKGROUND: SARS-CoV-2 caused one of the most devastating pandemics in the recent history of mankind. Due to various countermeasures, including lock-downs, wearing masks, and increased hygiene, the virus has been controlled in some parts of the world. More recently, the availability of vaccines, based on RNA or adenoviruses, has greatly added to our ability to keep the virus at bay; again, however, in some parts of the world only. While available vaccines are effective, it would be desirable to also have more classical vaccines at hand for the future. Key feature of vaccines for long-term control of SARS-CoV-2 would be inexpensive production at large scale, ability to make multiple booster injections, and long-term stability at 4℃. METHODS: Here, we describe such a vaccine candidate, consisting of the SARS-CoV-2 receptor-binding motif (RBM) grafted genetically onto the surface of the immunologically optimized cucumber mosaic virus, called CuMVTT -RBM. RESULTS: Using bacterial fermentation and continuous flow centrifugation for purification, the yield of the production process is estimated to be >2.5 million doses per 1000-litre fermenter run. We demonstrate that the candidate vaccine is highly immunogenic in mice and rabbits and induces more high avidity antibodies compared to convalescent human sera. The induced antibodies are more cross-reactive to mutant RBDs of variants of concern (VoC). Furthermore, antibody responses are neutralizing and long-lived. In addition, the vaccine candidate was stable for at least 14 months at 4℃. CONCLUSION: Thus, the here presented VLP-based vaccine may be a good candidate for use as conventional vaccine in the long term.


Assuntos
COVID-19 , Vacinas de Partículas Semelhantes a Vírus , Animais , Anticorpos Neutralizantes , Formação de Anticorpos , Vacinas contra COVID-19 , Controle de Doenças Transmissíveis , Humanos , Camundongos , Coelhos , SARS-CoV-2
2.
Vet Ophthalmol ; 23(2): 212-218, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31441205

RESUMO

OBJECTIVE: To analyze D-dimer concentrations in aqueous humor (AH) of rabbit eyes under physiological conditions, after induction of fibrin clots, and following fibrinolytic therapy. ANIMALS STUDIED: Prospective study measuring D-dimers in aqueous humor of rabbit eyes with induced fibrin clots (n = 44). PROCEDURES: Rabbits were purchased in two groups, which led to two temporally separated experimentation groups. Different treatment protocols were compared for their efficacy in fibrin reduction (slit-lamp examination, high-resolution ultrasound). AH was taken from left eyes before clot induction (baseline, day 1), 24 hours later after clot establishment/prior to drug administration (post-induction, day 2) and 48 hours after clot induction (post-treatment, day 3). An enzyme-linked immunosorbent assay (ELISA) was performed to measure intraocular D-dimer concentrations RESULTS: D-dimer concentrations were measurable in all samples. There were no differences in D-dimer levels across time points or treatments within the arrival groups. However, a significant difference in mean D-dimer levels was observed between the two arrival groups (group 1:3.1 µg/mL; group 2:6.1 µg/mL; P < .0001), which made a direct comparison of treatment groups impossible. Clinically, all eyes displayed fibrin clots in the anterior chamber and different treatment types led to significant differences in clot resolution (clot size reduction after intracameral treatment: 98%, topical treatment: 60%, no treatment: 40%). CONCLUSION: D-dimers were identified in all AH samples of rabbits with large variability between samples. D-dimer levels were neither predictive for differences in induced fibrin formation nor for drug efficacy.


Assuntos
Humor Aquoso/química , Produtos de Degradação da Fibrina e do Fibrinogênio/química , Fibrina/química , Ativadores de Plasminogênio/farmacologia , Coelhos , Animais , Feminino , Fibrina/metabolismo , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Fibrinolíticos , Estudos Prospectivos
3.
Clin Orthop Relat Res ; 477(5): 990-1003, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30507833

RESUMO

BACKGROUND: Biochemical MRI of hip cartilage such as delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) and T2 mapping is increasingly used to judge cartilage quality in the assessment of femoroacetabular impingement (FAI). The current evidence is sparse about which of these techniques yields a stronger correlation with histologic cartilage degeneration because of the difficulty in validating biochemical MRI techniques against histology in the clinical setting. Recently, an experimental ovine FAI model was established that induces chondrolabral damage and offers a validated platform to address these limitations. QUESTIONS/PURPOSES: In a sheep model, we asked: (1) Do dGEMRIC and/or T2 values of acetabular and femoral cartilage correlate with histologic cartilage degeneration as assessed with the Mankin score? (2) Do simultaneously measured dGEMRIC and T2 values correlate in an experimental ovine FAI model? METHODS: We performed an experimental pilot study on five female Swiss Alpine sheep (10 hips) that underwent postmortem MRI, including biochemical cartilage sequences, after a staged FAI correction had been performed on one side. No surgery was performed on the contralateral side, which served as a healthy control. In these sheep, an extraarticular intertrochanteric varus osteotomy was performed to rotate the naturally aspherical ovine femoral head into the acetabulum to induce cam-type FAI and chondrolabral damage comparable to human beings. After a 70-day ambulation period, femoral osteochondroplasty was performed and all sheep were euthanized after a total observation period of 210 days. Before they were euthanized, the sheep received a contrast agent and roamed and walked for at least 45 minutes. Hips were prepared to fit in a knee coil and MRI was performed at 3 T including a three-dimensional (3-D) dGEMRIC sequence, a two-dimensional (2-D) radial T2 mapping sequence, and a 2-D radial proton density-weighted sequence for morphologic cartilage assessment. Using specifically developed software, the 3-D dGEMRIC images and T2 maps were coregistered on the 2-D morphologic radial images. This enabled us to simultaneously measure dGEMRIC and T2 values using the identical regions of interest. dGEMRIC and T2 values of the acetabular and femoral cartilage were measured circumferentially using anatomic landmarks. After MRI, bone-cartilage samples were taken from the acetabulum and the femur and stained with toluidine blue for assessment of the histologic cartilage degeneration using the Mankin score, which was assessed in consensus by two observers. Spearman's rank correlation coefficient was used to (1) correlate dGEMRIC values and T2 values with the histologic Mankin score of femoroacetabular cartilage; and to (2) correlate dGEMRIC values and T2 values of femoroacetabular cartilage. RESULTS: A moderate to fair correlation between overall dGEMRIC values of the acetabular cartilage (R = -0.430; p = 0.003) and the femoral cartilage (R = -0.334; p = 0.003) versus the histologic Mankin score was found. A moderate correlation (R = -0.515; p = 0.010) was found among peripheral dGEMRIC values of the acetabulum, the superior femoral cartilage (R = -0.500; p = 0.034), and the histologic Mankin score, respectively. No correlation between overall and regional femoroacetabular T2 values and the histologic Mankin scores was found. No correlation between overall and regional femoroacetabular dGEMRIC values and T2 values was found. CONCLUSIONS: In this recently established sheep model, we found dGEMRIC values correlated well with histologic evidence of cartilage degeneration in the hip. This combination of a robust animal model and an accurate imaging technique appears to offer a noninvasive means to study the natural course of FAI and to compare the effectiveness of potential surgical options to treat it. CLINICAL RELEVANCE: This translational study supports the continuing use of dGEMRIC as a biomarker for prearthritic cartilage degeneration with the ultimate goal to identify patients who will benefit most from corrective FAI surgery. The value of T2 imaging of hip cartilage warrants further investigation.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Impacto Femoroacetabular/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Animais , Cartilagem Articular/patologia , Modelos Animais de Doenças , Feminino , Impacto Femoroacetabular/patologia , Articulação do Quadril/patologia , Processamento de Imagem Assistida por Computador , Ovinos
4.
BMC Vet Res ; 14(1): 327, 2018 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-30400793

RESUMO

BACKGROUND: Objective of this study is a feasibility-test comparing hock- and footpad-injection in rats with inoculated MatLyLu - adenocarcinoma tumor model. This study compares the development of an adenocarcinoma model (MatLyLu) in 12 Copenhagen rats. Two groups (n = 6) of animals were inoculated with 1 × 106 MatLyLu tumor cells solved in 0.1 ml NaCl either by footpad or hock injection. All animals were examined before tumor inoculation and before euthanasia using a 3.0 Tesla MRI. Histological evaluation of all organs was performed post mortem. RESULTS: Both types of injection were able to induce the adenocarcinoma model using MatLyLu tumor cells. The primary tumor could be visualized in MRI and confirmed histologically. Comparing the risk of reflux and the maximum injection volume during injection, the hock injection was superior to the footpad injection (less reflux, less anatomical restrictions for larger volumes). The hock injection induces a faster tumor growth compared to the footpad injection. As consequence the maximum level of long term discomfort after hock injection was reached earlier, even if it grew on a not weight bearing structure. Early lymph node tumor metastasis could not be observed macroscopically nor detected histologically. Therefore the reproducibility of the MatLyLu tumor model is questionable. CONCLUSION: Hock injection is a feasible alternative technique compared with footpad-injection in rats. It provides a save and easy injection method for various early-terminated applications with the potential to increase animal welfare during tumor models in rats.


Assuntos
Adenocarcinoma/veterinária , Modelos Animais de Doenças , , Transplante de Neoplasias/veterinária , Neoplasias da Próstata/veterinária , Tarso Animal , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Animais , Feminino , Injeções/veterinária , Imageamento por Ressonância Magnética , Masculino , Transplante de Neoplasias/diagnóstico por imagem , Transplante de Neoplasias/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Ratos
5.
Lasers Med Sci ; 33(7): 1471-1478, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29654421

RESUMO

Most industrial laser applications utilize computer and robot assistance, for guidance, safety, repeatability, and precision. In contrast, medical applications using laser systems are mostly conducted manually. The advantages can be effective only when the system is coupled to a robotic guidance, as operating by hand does not reach the required accuracy. We currently developed the first laser osteotome which offers preoperative planning based on CT data, robot guidance, and a precise execution of the laser cuts. In an animal trial, our system was used to create a grid pattern of the same depth on the inner layer of parietal bone in 12 adult sheep. The same bone cuts were done with piezoelectric osteotome on the contralateral side. The micro-CT and histological analysis showed more new mineralized bone in the laser group compared to the piezoelectric group. As well, a cutting pattern with especially a constant osteotomy depth in the laser group was demonstrated. The here presented autonomous osteotomy tool shows not only an advantage in early bone healing stage but additionally sharp bone cuts with a very high accuracy and freely selectable design cuts.


Assuntos
Osso e Ossos/anatomia & histologia , Osso e Ossos/cirurgia , Terapia a Laser , Lasers , Osteotomia/instrumentação , Robótica , Cirurgia Assistida por Computador , Animais , Osso e Ossos/citologia , Osso e Ossos/diagnóstico por imagem , Calcificação Fisiológica , Ovinos , Microtomografia por Raio-X
6.
J Shoulder Elbow Surg ; 26(5): 733-744, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28131694

RESUMO

BACKGROUND: Disturbed muscular architecture, atrophy, and fatty infiltration remain irreversible in chronic rotator cuff tears even after repair. Poly (adenosine 5'-diphosphate-ribose) polymerase 1 (PARP-1) is a key regulator of inflammation, apoptosis, muscle atrophy, muscle regeneration, and adipocyte development. We hypothesized that the absence of PARP-1 would lead to a reduction in damage to the muscle subsequent to combined tenotomy and neurectomy in a PARP-1 knockout (KO) mouse model. METHODS: PARP-1 KO and wild-type C57BL/6 (WT group) mice were analyzed at 1, 6, and 12 weeks (total n = 84). In all mice, the supraspinatus and infraspinatus muscles of the left shoulder were detached and denervated. Macroscopic analysis, magnetic resonance imaging, gene expression analysis, immunohistochemistry, and histology were used to assess the differences in PARP-1 KO and WT mice. RESULTS: The muscles in the PARP-1 KO group had significantly less retraction, atrophy, and fatty infiltration after 12 weeks than in the WT group. Gene expression of inflammatory, apoptotic, adipogenic, and muscular atrophy genes was significantly decreased in PARP-1 KO mice in the first 6 weeks. DISCUSSION: Absence of PARP-1 leads to a reduction in muscular architectural damage, early inflammation, apoptosis, atrophy, and fatty infiltration after combined tenotomy and neurectomy of the rotator cuff muscle. Although the macroscopic reaction to injury is similar in the first 6 weeks, the ability of the muscles to regenerate was much greater in the PARP-1 KO group, leading to a near-normalization of the muscle after 12 weeks.


Assuntos
Atrofia Muscular/etiologia , Poli(ADP-Ribose) Polimerases/fisiologia , Lesões do Manguito Rotador/patologia , Tecido Adiposo/patologia , Animais , Modelos Animais de Doenças , Imageamento por Ressonância Magnética , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Atrofia Muscular/diagnóstico por imagem , Atrofia Muscular/patologia , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/etiologia , Tenotomia
7.
Clin Orthop Relat Res ; 474(12): 2633-2640, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27535284

RESUMO

BACKGROUND: Osteochondroplasty of the head-neck region is performed on patients with cam femoroacetabular impingement (FAI) without fully understanding its repercussion on the integrity of the femur. Cam-type FAI can be surgically and reproducibly induced in the ovine femur, which makes it suitable for studying corrective surgery in a consistent way. Finite element models built on quantitative CT (QCT) are computer tools that can be used to predict femoral strength and evaluate the mechanical effect of surgical correction. QUESTIONS/PURPOSES: We asked: (1) What is the effect of a resection of the superolateral aspect of the ovine femoral head-neck junction on failure load? (2) How does the failure load after osteochondroplasty compare with reported forces from activities of daily living in sheep? (3) How do failure loads and failure locations from the computer simulations compare with the experiments? METHODS: Osteochondroplasties (3, 6, 9 mm) were performed on one side of 18 ovine femoral pairs with the contralateral intact side as a control. The 36 femurs were scanned via QCT from which specimen-specific computer models were built. Destructive compression tests then were conducted experimentally using a servohydraulic testing system and numerically via the computer models. Safety factors were calculated as the ratio of the maximal force measured in vivo by telemeterized hip implants during the sheep's walking and running activities to the failure load. The simulated failure loads and failure locations from the computer models were compared with the experimental results. RESULTS: Failure loads were reduced by 5% (95% CI, 2%-8%) for the 3-mm group (p = 0.0089), 10% (95% CI, 6%-14%) for the 6-mm group (p = 0.0015), and 19% (95% CI, 13%-26%) for the 9-mm group (p = 0.0097) compared with the controls. Yet, the weakest specimen still supported more than 2.4 times the peak load during running. Strong correspondence was found between the simulated and experimental failure loads (R2 = 0.83; p < 0.001) and failure locations. CONCLUSIONS: The resistance of ovine femurs to fracture decreased with deeper resections. However, under in vitro testing conditions, the effect on femoral strength remains small even after 9 mm correction, suggesting that femoral head-neck osteochondroplasty could be done safely on the ovine femur. QCT-based finite element models were able to predict weakening of the femur resulting from the osteochondroplasty. CLINICAL RELEVANCE: The ovine femur provides a seemingly safe platform for scientific evaluation of FAI. It also appears that computer models based on preoperative CT scans may have the potential to provide patient-specific guidelines for preventing overcorrection of cam FAI.


Assuntos
Simulação por Computador , Impacto Femoroacetabular/cirurgia , Fraturas do Colo Femoral/prevenção & controle , Cabeça do Fêmur/cirurgia , Colo do Fêmur/cirurgia , Análise de Elementos Finitos , Modelos Biológicos , Procedimentos Ortopédicos , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Feminino , Impacto Femoroacetabular/fisiopatologia , Fraturas do Colo Femoral/etiologia , Fraturas do Colo Femoral/fisiopatologia , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/fisiopatologia , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/fisiopatologia , Procedimentos Ortopédicos/efeitos adversos , Osteotomia , Fatores de Risco , Ovinos , Estresse Mecânico , Tomografia de Coerência Óptica , Falha de Tratamento
8.
J Mater Sci Mater Med ; 26(2): 87, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25644101

RESUMO

The aim of this study was to analyse the osseointegrative potential of phosphoserine-tethered dendrons when applied as surface functionalisation molecules on titanium implants in a sheep model after 2 and 8 weeks of implantation. Uncoated and dendron-coated implants were implanted in six sheep. Sandblasted and etched (SE) or porous additive manufactured (AM) implants with and without additional dendron functionalisation (SE-PSD; AM-PSD) were placed in the pelvic bone. Three implants per group were examined histologically and six implants were tested biomechanically. After 2 and 8 weeks the bone-to-implant contact (BIC) total values of SE implants (43.7±12.2; 53.3±9.0%) and SE-PSD (46.7±4.5; 61.7±4.9%) as well as AM implants (20.49±5.1; 43.9±9.7%) and AM-PSD implants (19.7±3.5; 48.3±15.6%) showed no statistically significant differences. For SE-PSD and AM-PSD a separate analysis of only the cancellous BIC demonstrated a statistically significant difference after 2 and 8 weeks. Biomechanical findings proved the overall increased stability of the porous implants after 8 weeks. Overall, the great effect of implant macro design on osseointegration was further supported by additional phosphoserine-tethered dendrons for SE and AM implants.


Assuntos
Osseointegração , Próteses e Implantes , Titânio , Animais , Materiais Revestidos Biocompatíveis , Dendrímeros , Feminino , Corantes Fluorescentes , Teste de Materiais , Microscopia Eletrônica de Varredura , Modelos Animais , Fosfosserina , Polilisina , Carneiro Doméstico , Propriedades de Superfície , Fatores de Tempo , Torque
9.
Sci Technol Adv Mater ; 16(3): 034606, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27877793

RESUMO

Non-healing and partially healing wounds are an important problem not only for the patient but also for the public health care system. Current treatment solutions are far from optimal regarding the chosen material properties as well as price and source. Biodegradable polyurethane (PUR) scaffolds have shown great promise for in vivo tissue engineering approaches, but accomplishment of the goal of scaffold degradation and new tissue formation developing in parallel has not been observed so far in skin wound repair. In this study, the mechanical properties and degradation behavior as well as the biocompatibility of a low-cost synthetic, pathogen-free, biocompatible and biodegradable extracellular matrix mimicking a PUR scaffold was evaluated in vitro. The novel PUR scaffolds were found to meet all the requirements for optimal scaffolds and wound dressings. These three-dimensional scaffolds are soft, highly porous, and form-stable and can be easily cut into any shape desired. All the material formulations investigated were found to be nontoxic. One formulation was able to be defined that supported both good fibroblast cell attachment and cell proliferation to colonize the scaffold. Tunable biodegradation velocity of the materials could be observed, and the results additionally indicated that calcium plays a crucial role in PUR degradation. Our results suggest that the PUR materials evaluated in this study are promising candidates for next-generation wound treatment systems and support the concept of using foam scaffolds for improved in vivo tissue engineering and regeneration.

10.
Eur Radiol ; 24(1): 12-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23881302

RESUMO

OBJECTIVES: We report a preclinical comparative study of a 96-strand braided flow diverter. METHODS: The 96-strand braided device was compared with the currently commercially available flow diverter with 48 strands. The devices were implanted across the neck of 12 elastase-induced aneurysms in New Zealand White rabbits and followed for 1 and 3 months (n = 6 respectively). Aneurysm occlusion rates, parent artery stenosis and patency of jailed branch occlusions were assessed by angiography, histology and scanning electron microscopy studies. RESULTS: It was feasible to navigate and implant the 96-strand device over the aneurysm orifice in all cases. At follow-up two aneurysms in the 48-strand vs. one in the 96-strand group were not occluded. This aneurysm from the 96-strand group however had a tracheal branch arising from the sac and showed a reverse remodelling of the vascular pouch at 3 months. In the occluded aneurysms, the parent artery was always completely reconstructed and the aneurysm orifice was sealed with neointimal tissue. No in-stent stenosis or jailed branch artery occlusion was observed. CONCLUSIONS: The 96-strand flow diverter proved to be safe, biocompatible and haemodynamically effective, induced stable occlusion of aneurysms and led to reverse remodelling of the parent artery. KEY POINTS: • Flow diversion has been introduced to improve endovascular treatment of cerebral aneurysms • A new low-permeability flow diverter is feasible for parent artery reconstruction. • The Silk 96 flow diverter appears effective at inducing aneurysm healing. • The covered branches remained patent at follow-up.


Assuntos
Aneurisma/cirurgia , Doenças das Artérias Carótidas/cirurgia , Artéria Carótida Primitiva , Stents , Aneurisma/diagnóstico por imagem , Aneurisma/patologia , Angiografia Digital , Animais , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/patologia , Modelos Animais de Doenças , Estudos de Viabilidade , Feminino , Permeabilidade , Desenho de Prótese , Coelhos
11.
Sci Rep ; 14(1): 10875, 2024 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740845

RESUMO

Three-dimensional information is essential for a proper understanding of the healing potential of the menisci and their overall role in the knee joint. However, to date, the study of meniscal vascularity has relied primarily on two-dimensional imaging techniques. Here we present a method to elucidate the intricate 3D meniscal vascular network, revealing its spatial arrangement, connectivity and density. A polymerizing contrast agent was injected into the femoral artery of human cadaver legs, and the meniscal microvasculature was examined using micro-computed tomography at different levels of detail and resolution. The 3D vascular network was quantitatively assessed in a zone-base analysis using parameters such as diameter, length, tortuosity, and branching patterns. The results of this study revealed distinct vascular patterns within the meniscus, with the highest vascular volume found in the outer perimeniscal zone. Variations in vascular parameters were found between the different circumferential and radial meniscal zones. Moreover, through state-of-the-art 3D visualization using micro-CT, this study highlighted the importance of spatial resolution in accurately characterizing the vascular network. These findings, both from this study and from future research using this technique, improve our understanding of microvascular distribution, which may lead to improved therapeutic strategies.


Assuntos
Imageamento Tridimensional , Microvasos , Microtomografia por Raio-X , Humanos , Imageamento Tridimensional/métodos , Microvasos/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Meniscos Tibiais/diagnóstico por imagem , Meniscos Tibiais/irrigação sanguínea , Menisco/diagnóstico por imagem , Masculino , Cadáver , Feminino
12.
Methods Mol Biol ; 2598: 227-263, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36355296

RESUMO

In this chapter, an introduction is given into histological techniques to research related to hyaline cartilage and subchondral bone. Emphasis is placed on the importance to investigate cartilage and bone as a unit, which includes the transition zone of the calcified cartilage and tidemark. Reasons for the appropriate selection of histological methods are presented such as when to use (decalcified) specimens for routine paraffin embedding including immunohistology, cryosections of cartilage alone, or non-decalcified specimens for embedding in polymethylmethacrylate with or without additional biomaterials. Appropriate staining methods are also outlined. Apart from detailed laboratory protocols for different embedding and staining methods including open communication about difficulties related to the various techniques, also practical instructions for state-of-the-art evaluation methods and their strengths and weaknesses are given. Sample figures for scoring methods are included.


Assuntos
Cartilagem Articular , Cartilagem Articular/patologia , Osso e Ossos
13.
J Control Release ; 358: 420-438, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37121513

RESUMO

Efficient and reproducible colonic drug delivery remains elusive. The aim of this study was to demonstrate specific colonic delivery in vivo in domestic pigs with a novel tablet formulation based on a dual release control concept using 5-aminosalicylic acid (5-ASA) and caffeine as drug substances. The developed controlled colonic release (CCR) tablet formulation employs a pH-sensitive coating based on Eudragit® FS 30 D to prevent drug release in the upper gastrointestinal tract, and a xyloglucan-based matrix to inhibit drug release after coating removal in the small intestine and to allow microbiome-triggered drug release by enzymatic action in the colon. CCR tablets were administered to domestic pigs and plasma concentration data was analyzed by physiologically based pharmacokinetic modeling to estimate absorbed amounts from small and large intestine and in vivo drug release rates by model-dependent deconvolution using immediate release (IR) tablets and intravenous solutions as reference. Peak concentration times (tmax) and values (cmax) of CCR 5-ASA and caffeine tablets indicated strongly delayed drug absorption and the deduced absorbed amount as a function of time confirmed absorption overwhelmingly from the large intestine. The microbially cleaved marker molecule sulfasalazine administered alone or together with caffeine in CCR tablets reported, in combination with telemetry measurements, gastrointestinal transit times and site of absorption. Drug release from CCR tablets was inferred to take place predominantly at the site of absorption at a release rate of caffeine that was much larger in the colon than in the small intestine indicating enzymatically triggered release by the colonic microbiome. Xyloglucanase activity in rectal and cecal samples was consistent with release data and compound recovery in fecal droppings was consistent with 5-ASA bioavailability. The results provide evidence that the developed formulation can prevent premature drug release and provide targeted colonic drug delivery. Clinical relevance based on the comparability between pig and man is discussed.


Assuntos
Cafeína , Sus scrofa , Suínos , Animais , Sistemas de Liberação de Medicamentos , Comprimidos , Preparações de Ação Retardada , Colo , Mesalamina
14.
Adv Healthc Mater ; 12(2): e2202106, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36250334

RESUMO

Inadequate mechanical compliance of orthopedic implants can result in excessive strain of the bone interface, and ultimately, aseptic loosening. It is hypothesized that a fiber-based biometal with adjustable anisotropic mechanical properties can reduce interface strain, facilitate continuous remodeling, and improve implant survival under complex loads. The biometal is based on strategically layered sintered titanium fibers. Six different topologies are manufactured. Specimens are tested under compression in three orthogonal axes under 3-point bending and torsion until failure. Biocompatibility testing involves murine osteoblasts. Osseointegration is investigated by micro-computed tomography and histomorphometry after implantation in a metaphyseal trepanation model in sheep. The material demonstrates compressive yield strengths of up to 50 MPa and anisotropy correlating closely with fiber layout. Samples with 75% porosity are both stronger and stiffer than those with 85% porosity. The highest bending modulus is found in samples with parallel fiber orientation, while the highest shear modulus is found in cross-ply layouts. Cell metabolism and morphology indicate uncompromised biocompatibility. Implants demonstrate robust circumferential osseointegration in vivo after 8 weeks. The biometal introduced in this study demonstrates anisotropic mechanical properties similar to bone, and excellent osteoconductivity and feasibility as an orthopedic implant material.


Assuntos
Materiais Biocompatíveis , Oligoelementos , Camundongos , Animais , Ovinos , Titânio , Microtomografia por Raio-X , Próteses e Implantes , Teste de Materiais , Osseointegração , Porosidade
15.
ACS Biomater Sci Eng ; 9(6): 2937-2948, 2023 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-36444758

RESUMO

Carbon monoxide (CO) is a therapeutic gas with therapeutic potential in intestinal bowel disease. Therapeutic efficacy in the gastrointestinal tract (GIT) must be paired with safe and convenient use. Therefore, we designed an oral CO releasing system (OCORS) pairing tunable CO release into the GIT while preventing the release of any other molecule from within the device, causing safety concerns. The dimensions of the device, which is manufactured from 3D printed components, are within compendial limits. This is achieved by controlling CO decarbonylation from a molybdenum complex with a FeCl3 solution. OCORS' surrounding silicon membranes control release rates, as does the loading with carbonylated molybdenum complex and FeCl3 solution. Herein we describe the development of the system, the characterization of the CO releasing molecule (CORM), and the CO release kinetics of the overall system. Neither the CORM nor isocyanoacetate as a potential reaction byproduct were cytotoxic. Finally, we demonstrated by design validation in an in vivo porcine model that, except for the release of the therapeutic CO, OCORS isolates all components during transit through the stomach. We could show that OCORS generated and released CO locally into the stomach of the animals without systemic exposure, measured as the carboxyhemoglobin content in the blood of the pigs. In conclusion, OCORS derisks oral development by limiting patient exposure to (desirable) CO while preventing contact with any further (undesirable) chemical, by-, or degradation products. CO generating devices come in reach, which now can be used by anyone, anywhere, and anytime.


Assuntos
Monóxido de Carbono , Molibdênio , Animais , Suínos , Monóxido de Carbono/uso terapêutico , Monóxido de Carbono/metabolismo
16.
BMC Musculoskelet Disord ; 13: 32, 2012 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-22400715

RESUMO

BACKGROUND: In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep. METHODS: Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically. RESULTS: Cobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials. CONCLUSION: This study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior.


Assuntos
Artroplastia de Quadril/instrumentação , Parafusos Ósseos/normas , Teste de Materiais/métodos , Metais/farmacologia , Osseointegração/fisiologia , Implantação de Prótese/métodos , Animais , Artroplastia de Quadril/métodos , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/uso terapêutico , Feminino , Metais/uso terapêutico , Modelos Animais , Carneiro Doméstico
17.
Eur Spine J ; 20(11): 1821-36, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21523457

RESUMO

The innovative BoneWelding(®) technology, where ultrasound energy bonds bioresorbable implants to bone, was tested for its feasibility in spine surgery and its local thermal effects. The three tested concepts consisted of implementation of a resorbable plating system, two converging polymer pins and suture anchors to the cervical vertebral bodies. Bioresorbable polylactide implants (PLDLLA 70/30) were inserted ventrally into the third and fourth vertebral body of seven sheep, of which six were sacrificed at 2 months and one sheep immediately after temperature measurements during implant insertion. Polymer screws were used as controls. Qualitative, semi-quantitative histological, and quantitative histomorphometrical evaluation showed excellent anchorage of the implants, new mineralized bone at the implant-bone interface, no inflammatory cell reaction or thermal damage to the adjacent bone in response to the novel insertion technology. The application of two converging pins, parallel inserted polymer pins, or fusion of the implant to the polymer plates did not affect the overall excellent tissue tolerance of the technology. Temperature increase during insertion was noticed but never exceeded 47°C for less than 1 s. The BoneWelding(®) technology was proven to be safe and easy to apply.


Assuntos
Implantes Absorvíveis , Vértebras Cervicais/cirurgia , Teste de Materiais , Animais , Estudos de Viabilidade , Feminino , Ovinos
18.
J Biomed Opt ; 26(9)2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34519191

RESUMO

SIGNIFICANCE: The highest absorption peaks of the main components of bone are in the mid-infrared region, making Er:YAG and CO2 lasers the most efficient lasers for cutting bone. Yet, studies of deep bone ablation in minimally invasive settings are very limited, as finding suitable materials for coupling high-power laser light with low attenuation beyond 2 µm is not trivial. AIM: The first aim of this study was to compare the performance of different optical fibers in terms of transmitting Er:YAG laser light with a 2.94-µm wavelength at high pulse energy close to 1 J. The second aim was to achieve deep bone ablation using the best-performing fiber, as determined by our experiments. APPROACH: In our study, various optical fibers with low attenuation (λ = 2.94 µm) were used to couple the Er:YAG laser. The fibers were made of germanium oxide, sapphire, zirconium fluoride, and hollow-core silica, respectively. We compared the fibers in terms of transmission efficiency, resistance to high Er:YAG laser energy, and bending flexibility. The best-performing fiber was used to achieve deep bone ablation in a minimally invasive setting. To do this, we adapted the optimal settings for free-space deep bone ablation with an Er:YAG laser found in a previous study. RESULTS: Three of the fibers endured energy per pulse as high as 820 mJ at a repetition rate of 10 Hz. The best-performing fiber, made of germanium oxide, provided higher transmission efficiency and greater bending flexibility than the other fibers. With an output energy of 370 mJ per pulse at 10 Hz repetition rate, we reached a cutting depth of 6.82 ± 0.99 mm in sheep bone. Histology image analysis was performed on the bone tissue adjacent to the laser ablation crater; the images did not show any structural damage. CONCLUSIONS: The findings suggest that our prototype could be used in future generations of endoscopic devices for minimally invasive laserosteotomy.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Óxido de Alumínio , Animais , Endoscópios , Fibras Ópticas , Ovinos
19.
Biomedicines ; 9(4)2021 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-33916829

RESUMO

Tendon defects require multimodal therapeutic management over extensive periods and incur high collateral burden with frequent functional losses. Specific cell therapies have recently been developed in parallel to surgical techniques for managing acute and degenerative tendon tissue affections, to optimally stimulate resurgence of structure and function. Cultured primary human fetal progenitor tenocytes (hFPT) have been preliminarily considered for allogeneic homologous cell therapies, and have been characterized as stable, consistent, and sustainable cell sources in vitro. Herein, optimized therapeutic cell sourcing from a single organ donation, industrial transposition of multi-tiered progenitor cell banking, and preliminary preclinical safety of an established hFPT cell source (i.e., FE002-Ten cell type) were investigated. Results underlined high robustness of FE002-Ten hFPTs and suitability for sustainable manufacturing upscaling within optimized biobanking workflows. Absence of toxicity or tumorigenicity of hFPTs was demonstrated in ovo and in vitro, respectively. Furthermore, a 6-week pilot good laboratory practice (GLP) safety study using a rabbit patellar tendon partial-thickness defect model preliminarily confirmed preclinical safety of hFPT-based standardized transplants, wherein no immune reactions, product rejection, or tumour formation were observed. Such results strengthen the rationale of the multimodal Swiss fetal progenitor cell transplantation program and prompt further investigation around such cell sources in preclinical and clinical settings for musculoskeletal regenerative medicine.

20.
Biomolecules ; 11(2)2021 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-33572428

RESUMO

Diverse cell therapy approaches constitute prime developmental prospects for managing acute or degenerative cartilaginous tissue affections, synergistically complementing specific surgical solutions. Bone marrow stimulation (i.e., microfracture) remains a standard technique for cartilage repair promotion, despite incurring the adverse generation of fibrocartilagenous scar tissue, while matrix-induced autologous chondrocyte implantation (MACI) and alternative autologous cell-based approaches may partly circumvent this effect. Autologous chondrocytes remain standard cell sources, yet arrays of alternative therapeutic biologicals present great potential for regenerative medicine. Cultured human epiphyseal chondro-progenitors (hECP) were proposed as sustainable, safe, and stable candidates for chaperoning cartilage repair or regeneration. This study describes the development and industrial transposition of hECP multi-tiered cell banking following a single organ donation, as well as preliminary preclinical hECP safety. Optimized cell banking workflows were proposed, potentially generating millions of safe and sustainable therapeutic products. Furthermore, clinical hECP doses were characterized as non-toxic in a standardized chorioallantoic membrane model. Lastly, a MACI-like protocol, including hECPs, was applied in a three-month GLP pilot safety evaluation in a caprine model of full-thickness articular cartilage defect. The safety of hECP transplantation was highlighted in xenogeneic settings, along with confirmed needs for optimal cell delivery vehicles and implantation techniques favoring effective cartilage repair or regeneration.


Assuntos
Cartilagem Articular/fisiologia , Transplante de Células , Terapia Baseada em Transplante de Células e Tecidos , Feto/citologia , Xenoenxertos , Medicina Regenerativa , Células-Tronco/citologia , Animais , Cabras/embriologia , Humanos , Modelos Animais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA