Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Oral Rehabil ; 42(3): 185-91, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25270097

RESUMO

The aims of this study were to examine the change of occlusal contact area following the increment of clenching intensity using silicone materials and electromyography (EMG) in normal subjects and to compare direct intra-oral examination with indirect examination using dental casts mounted by means of two impression methods. Participants were 7 men and 5 women with no more than one missing tooth per quadrant and no pain in the head and neck region. During the task, intercuspal position was maintained with minimal force, 20% maximum voluntary contraction (MVC) and 40% MVC using electromyography visual feedback. Three types of occlusal contact examinations were performed with the aid of blue silicone material in randomised order: (i) intra-oral direct occlusal contact examination (DE), (ii) indirect occlusal contact examination with dental casts using conventional impression method (IEC) and (iii) using occlusal impression method (IEO). Total occlusal contact area during DE and IEO significantly increased from baseline to 20% MVC and from baseline to 40% MVC, but not during IEC. Total occlusal contact area during DE in all tooth clenching conditions was significantly larger compared to IEO and IEC (P < 0·05). At 40% MVC, total occlusal contact area during IEO was significantly larger than during IEC (P < 0·05). These findings suggest that indirect occlusal contact examinations may not accurately reflect the intra-oral occlusal condition. If the intra-oral condition is reproduced using dental casts, these findings also suggest the occlusal impression method was more accurate compared to the conventional method (240 words).


Assuntos
Força de Mordida , Músculos da Mastigação/fisiologia , Contração Muscular/fisiologia , Adulto , Materiais para Moldagem Odontológica , Eletromiografia , Feminino , Humanos , Masculino , Adulto Jovem
2.
J Oral Rehabil ; 41(3): 218-25, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24447195

RESUMO

This study examined the influence of narrative instructions on the occlusal contact area, occlusal contact point and masticatory muscle activities in normal subjects. Twelve healthy men and 12 healthy women with no more than one missing tooth per quadrant participated. Surface EMG was recorded from the masseter and temporal muscle. As a control measurement, intercuspal position was maintained to produce a habitual clenching record (NCR) while the occlusal contact area and occlusal contact point was recorded by means of silicone material. Subsequently, the occlusal contact area was recorded with the narrative instruction for minimum clenching record (MCR), light clenching record (LCR) and strong clenching record (HCR). While the EMG activity (%MVC) increased modestly from MCR to LCR (from 9·3 ± 2·0% to 11·5 ± 1·5%), the occlusal contact area increased rapidly (from 17·2 ± 11·3 mm(2) to 26·8 ± 15·6 mm(2) ) (P < 0·05). Both EMG activity and occlusal contact area increased gradually from LCR to NCR (to 17·7 ± 2·0% and to 31·4 ± 14·2 mm(2) , respectively). Finally, EMG activity still increased from NCR to HCR (to 44·5 ± 3·7%) (P < 0·05), but the occlusal contact area remained stable (to 36·8 ± 16·6 mm(2) ). Occlusal contact points at left posterior, right posterior, anterior and total area were not significantly different between each task. This study showed that narrative instructions while recording the bite can result in largely stable occlusal contact area. An adequate narrative instruction may therefore contribute to taking a stable occlusal recording in natural dentition.


Assuntos
Força de Mordida , Músculos da Mastigação/fisiologia , Narração , Adulto , Eletromiografia , Feminino , Humanos , Masculino , Silicones , Adulto Jovem
3.
J Oral Rehabil ; 40(11): 834-43, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23889702

RESUMO

This study explored the influence of the thickness of silicone registration material on evaluation of the occlusal contact area and number of occlusal contact points, during increasing tooth clenching conditions in normal subjects. Twenty-four subjects with no more than one missing tooth per quadrant participated. Surface electro-myography was recorded from the masseter muscle. As a baseline measurement, intercuspal position was maintained with minimal force, and occlusal contact was recorded using blue silicone material. Occlusal contact was also recorded at 20% maximum voluntary contraction (MVC) and 40% MVC using visual feedback. The occlusal contact area and number of occlusal contact points were analysed using five levels of thickness of silicone registration material: Level 1 (0-149 µm); Level 2 (0-89 µm); Level 3 (0-49 µm); Level 4 (0-29 µm); and Level 5 (0-4 µm). The anterior part and the left and right posterior regions of the dental arch were analysed separately. At all detection levels, the occlusal contact area significantly increased from baseline to 20% MVC and to 40% MVC in the molar area (P < 0·05). In the anterior part, the occlusal contact area significantly increased from baseline to 20% MVC and to 40% MVC only when using Level 5. The number of occlusal contact points significantly increased from baseline to 20% MVC and to 40% MVC only when using Level 5 in the molar area (P < 0·05). It suggested that occlusal contacts may be different at low tooth clenching intensity with potential effects on the teeth or periodontal tissues.


Assuntos
Força de Mordida , Materiais para Moldagem Odontológica , Músculo Masseter/fisiologia , Silicones , Adulto , Eletromiografia , Feminino , Humanos , Masculino , Adulto Jovem
4.
J Comp Pathol ; 157(1): 57-60, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28735672

RESUMO

A 5-year-old male miniature dachshund was presented with a dermal nodule on the left forelimb that increased to 5 mm in diameter over a 2-month period. Grossly, the nodule was firm, and both the external and cut surfaces were homogeneously pale pink in colour. Microscopically, the nodule was comprised of mainly plump endothelial cells and inflammatory cells; among the latter, lymphocytes were predominant, with few scattered plasma cells, mast cells and macrophages. Lymphoid follicles with germinal centres were often observed. Mitotic figures were not observed amongst the endothelial cells. Immunohistochemically, the endothelial cells were positive for vimentin, factor VIII-related antigen and CD31, and the surrounding cells were positive for smooth muscle actin. Lymphocytes expressed CD3 or BLA36. These findings led to a diagnosis of cutaneous angiolymphoid hyperplasia. To the best of our knowledge, this is the first report of a cutaneous proliferative disorder comprising an admixture of proliferating vascular endothelial cells and lymphocytic infiltration with follicle formation in a dog.


Assuntos
Hiperplasia Angiolinfoide com Eosinofilia/veterinária , Doenças do Cão/patologia , Animais , Cães , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA