Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Radiat Oncol Biol Phys ; 59(4): 1224-8, 2004 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-15234059

RESUMO

PURPOSE: Although accelerated partial breast irradiation (APBI) as the sole radiation modality after lumpectomy has shown promising results for select breast cancer patients, published experiences thus far have provided limited information on treatment planning methodology and quality assurance measures. A novel three-dimensional computed tomography (CT)-based treatment planning method for accurate delineation and geometric coverage of the target volume is presented. A correlation between treatment volume and irradiation time has also been studied for quality assurance purposes. METHODS AND MATERIALS: Between May 2002 and January 2003, 50 consecutive patients underwent an image-guided interstitial implant followed by CT-based treatment planning and were subsequently treated with APBI with a high-dose-rate (HDR) brachytherapy remote afterloader. Target volume was defined as the lumpectomy cavity +2 cm margin modified to >/=5 mm to the skin surface. Catheter reconstruction, geometric optimization, and manual adjustment of irradiation time were done to optimally cover the target volume while minimizing hot spots. Dose homogeneity index (DHI) and percent of target volume receiving 100% of the prescription dose (32 Gy in 8 fractions or 34 Gy in 10 fractions) was determined. Additionally, the correlation between the treatment volume and irradiation time, source strength, and dose was then analyzed for manual verification of the HDR computer calculation. RESULTS: In all cases, the lumpectomy cavity was covered 100%. Target volume coverage was excellent with a median of 96%, and DHI had a median value of 0.7. For each plan, source strength times the treatment time for every unit of prescribed dose had an excellent agreement of +/-7% to the Manchester volume implant table corrected for modern units. CONCLUSIONS: CT-based treatment planning allowed excellent visualization of the lumpectomy cavity and normal structures, thereby improving target volume delineation and optimal coverage, relative to conventional orthogonal film dosimetry. Using the Manchester volume implant table calculated irradiation time can be used as quality assurance for the HDR computed time. Thus dosimetric quality assurance and adequate target volume coverage can be concurrently confirmed, allowing prospective evaluation and optimization of implants.


Assuntos
Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Braquiterapia/normas , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Terapia Combinada , Feminino , Humanos , Mastectomia Segmentar , Agulhas , Controle de Qualidade , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção
2.
Technol Cancer Res Treat ; 3(6): 639-46, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15560722

RESUMO

A novel treatment approach utilizing helical tomotherapy for partial breast irradiation for patients with early-stage breast cancer is described. This technique may serve as an alternative to high dose-rate (HDR) interstitial brachytherapy and standard linac-based approaches. Through helical tomotherapy, highly conformal irradiation of target volumes and avoidance of normal sensitive structures can be achieved. Unlike HDR brachytherapy, it is noninvasive. Unlike other linac-based techniques, it provides image-guided adaptive radiotherapy along with intensity modulation. A treatment planning CT scan was obtained as usual on a post-lumpectomy patient undergoing HDR interstitial breast brachytherapy. The patient underwent catheter placement for HDR treatment and was positioned prone on a specially designed position-supporting mattress during CT. The planning target volume (PTV) was defined as the lumpectomy bed plus a 20 mm margin. The prescription dose was 34 Gy (10 fx of 3.4 Gy) in both the CT based HDR and on the tomotherapy plan. Cumulative dose-volume histograms (DVHs) were generated and analyzed for the target, lung, heart, skin, pectoralis muscle, and chest wall for both HDR brachytherapy and helical tomotherapy. Dosimetric coverage of the target with helical tomotherapy was conformal and homogeneous. "Hot spots" (> or =150% isodose line) were present around implanted dwell positions in brachytherapy plan whereas no isodose lines higher than 109% were present in the helical tomotherapy plan. Similar dose coverage was achieved for lung, pectoralis muscle, heart, chest wall and breast skin with the two methods. We also compared our results to that obtained using conventional linac-based three dimensional (3D) conformal accelerated partial breast irradiation. Dose homogeneity is excellent with 3D conformal irradiation, and lung, heart and chest wall dose is less than for either HDR brachytherapy or helical tomotherapy but skin and pectoral muscle doses were higher than with the other techniques. Our results suggest that helical tomotherapy can serve as an effective means of delivering accelerated partial breast irradiation and may offer superior dose homogeneity compared to HDR brachytherapy.


Assuntos
Neoplasias da Mama/radioterapia , Braquiterapia , Neoplasias da Mama/patologia , Humanos , Terapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA