Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Magn Reson Med ; 88(3): 1391-1405, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35635156

RESUMO

PURPOSE: To develop a coil-based method to obtain accurate sensitivity profiles in 13 C MRI at 3T from the endogenous 23 Na. An eight-channel array is designed for 13 C MR acquisitions. As application examples, the array is used for two-fold accelerated acquisitions of both hyperpolarized 13 C metabolic imaging of pig kidneys and the human brain. METHODS: A flexible coil array was tuned optimally for 13 C at 3T (32.1 MHz), with the coil coupling coefficients matched to be nearly identical at the resonance frequency of 23 Na (33.8 MHz). This is done by enforcing a high decoupling (obtained through highly mismatched preamplifiers) and adjusting the coupling frequency response. The SNR performance is compared to reference coils. RESULTS: The measured sensitivity profiles on a phantom showed high spatial similarity for 13 C and 23 Na resonances, with average noise correlation of 9 and 11%, respectively. For acceleration factors 2, 3, and 4, the obtained maximum g-factors were 1.0, 1.1, and 2.6, respectively. The 23 Na profiles obtained in vivo could be used successfully to perform two-fold acceleration of hyperpolarized 13 C 3D acquisitions of both pig kidneys and a healthy human brain. CONCLUSION: A receive array has been developed in such a way that the 13 C sensitivity profiles could be accurately obtained from measurements at the 23 Na frequency. This technique facilitates accelerated acquisitions for hyperpolarized 13 C imaging. The SNR performance obtained at the 13 C frequency, compares well to other state-of-the-art coils for the same purpose, showing slightly better superficial and central SNR.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Animais , Encéfalo/diagnóstico por imagem , Desenho de Equipamento , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Razão Sinal-Ruído , Suínos
2.
Magn Reson Med ; 84(2): 519-534, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31960506

RESUMO

PURPOSE: To test a new parallel imaging strategy for acceleration of hyperpolarized 13 C MR acquisitions based on a 3D blipped stack-of-spirals trajectory and conjugate-gradient SENSE reconstruction with precalibrated sensitivities. METHODS: The blipped stack-of-spirals trajectory was developed for an acceleration factor of 4, based on an undersampled stack-of-spirals with gradient blips during spiral readout. The trajectory was developed with volumetric coverage of a large FOV and with high spatial resolution. High temporal resolution was attained through spectral-spatial excitation and 4 excitations per volume. The blipped stack-of-spirals was evaluated in simulations and phantom experiments. Next, the method was evaluated for kidney and cardiac imaging in 2 separate healthy pigs. RESULTS: Simulation and phantom results showed successful acquisition and reconstruction, but also revealed reconstruction challenges for certain locations and for wide signal sources. For the kidney experiment, the accelerated acquisition showed high similarity to 2 separately acquired fully sampled data sets with matched spatial and temporal resolution, respectively. For the cardiac experiment, the accelerated acquisition proved able to map each metabolite in 3 dimensions within a single cardiac cycle. CONCLUSION: The proposed method demonstrated effective mapping of metabolism in both kidneys and the heart of healthy pigs. Limitations seen in phantom experiments, may be irrelevant for most clinical applications, but should be kept in mind as well as reconstruction challenges related to residual aliasing. All in all, we show that the blipped stack-of-spirals is a relevant parallel imaging method for hyperpolarized human imaging, facilitating better insights into metabolism compared with nonaccelerated acquisition.


Assuntos
Algoritmos , Imageamento Tridimensional , Animais , Simulação por Computador , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Suínos
3.
J Cereb Blood Flow Metab ; 41(11): 2916-2927, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34013807

RESUMO

Acute ischemic stroke patients benefit from reperfusion in a short time-window after debut. Later treatment may be indicated if viable brain tissue is demonstrated and this outweighs the inherent risks of late reperfusion. Magnetic resonance imaging (MRI) with hyperpolarized [1-13C]pyruvate is an emerging technology that directly images metabolism. Here, we investigated its potential to detect viable tissue in ischemic stroke. Stroke was induced in pigs by intracerebral injection of endothelin 1. During ischemia, the rate constant of pyruvate-to-lactate conversion, kPL, was 52% larger in penumbra and 85% larger in the infarct compared to the contralateral hemisphere (P = 0.0001). Within the penumbra, the kPL was 50% higher in the regions that later infarcted compared to non-progressing regions (P = 0.026). After reperfusion, measures of pyruvate-to-lactate conversion were slightly decreased in the infarct compared to contralateral. In addition to metabolic imaging, we used hyperpolarized pyruvate for perfusion-weighted imaging. This was consistent with conventional imaging for assessment of infarct size and blood flow. Lastly, we confirmed the translatability of simultaneous assessment of metabolism and perfusion with hyperpolarized MRI in healthy volunteers. In conclusion, hyperpolarized [1-13C]pyruvate may aid penumbral characterization and increase access to reperfusion therapy for late presenting patients.


Assuntos
Infarto Encefálico/diagnóstico por imagem , AVC Isquêmico/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ácido Pirúvico/metabolismo , Reperfusão/métodos , Animais , Encéfalo/metabolismo , Infarto Encefálico/metabolismo , Infarto Encefálico/patologia , Estudos de Casos e Controles , Circulação Cerebrovascular/fisiologia , Endotelina-1/metabolismo , Feminino , Humanos , AVC Isquêmico/metabolismo , Modelos Animais , Imagem de Perfusão/métodos , Suínos
4.
J Magn Reson ; 318: 106798, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32755748

RESUMO

A quality assurance protocol for RF coils is proposed, which can be used for volume (Tx/Rx) and surface (Rx) coils. Following this protocol, a benchmarking of seven coils (from three different MR sites) dedicated to 13C MRI at 3T is reported. Coil performance is particularly important for 3T MRI at the 13C frequency, since the coil-to-sample noise ratio is typically high. The coils are evaluated experimentally using the proposed protocol based on MR spectroscopic imaging performed with two different phantoms: one head-shaped, and one with cylindrical shape and nearly twice the volume of the first one. To achieve an unbiased SNR comparison of volume and array coils, coil combination was done using sensitivity profiles extracted from the data. SNR, noise correlation matrices and example g-factor maps are reported. For globally calibrated, equal excitation angles, the measured SNR shows large differences for the volume coils of up to 115% at the phantom center for a head phantom. The arrays show lower differences in superficial SNR. The sample surface depth at which the volume coils outperform the arrays is estimated to 7 cm, and SNR furthest away from the coil surface is 28% lower for the best array compared to the best volume coil. A broad set of coils for 13C at 3T have been benchmarked. The results reported, and the method used to benchmark them, should guide the 13C community to choose the most suitable coil for a given experiment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA