Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Digit Imaging ; 26(6): 1124-30, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23579735

RESUMO

Monitoring the openness of the major temporal arcade (MTA) and how it changes over time could facilitate diagnosis and treatment of proliferative diabetic retinopathy (PDR). We present methods for user-guided semiautomated modeling and measurement of the openness of the MTA based on Gabor filters for the detection of retinal vessels, morphological image processing, and a form of the generalized Hough transform for the detection of parabolas. The methods, implemented via a graphical user interface, were tested with retinal fundus images of 11 normal individuals and 11 patients with PDR in the present pilot study on potential clinical application. A method of arcade angle measurement was used for comparative analysis. The results using the openness parameters of single- and dual-parabolic models as well as the arcade angle measurements indicate areas under the receiver operating characteristics of A z = 0.87, 0.82, and 0.80, respectively. The proposed methods are expected to facilitate quantitative analysis of the architecture of the MTA, as well as assist in detection and diagnosis of PDR.


Assuntos
Retinopatia Diabética/diagnóstico , Diagnóstico por Computador/métodos , Angiofluoresceinografia/métodos , Fundo de Olho , Processamento de Imagem Assistida por Computador/métodos , Idoso , Bases de Dados Factuais , Feminino , Humanos , Masculino , Curva ROC , Radiografia , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Artérias Temporais/diagnóstico por imagem , Interface Usuário-Computador
2.
Can J Ophthalmol ; 53(4): 309-313, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30119782

RESUMO

Deep learning is an emerging technology with numerous potential applications in Ophthalmology. Deep learning tools have been applied to different diagnostic modalities including digital photographs, optical coherence tomography, and visual fields. These tools have demonstrated utility in assessment of various disease processes including cataracts, glaucoma, age-related macular degeneration, and diabetic retinopathy. Deep learning techniques are evolving rapidly, and will become more integrated into ophthalmic care. This article reviews the current evidence for deep learning in ophthalmology, and discusses future applications, as well as potential drawbacks.


Assuntos
Aprendizado Profundo , Diagnóstico por Computador/métodos , Técnicas de Diagnóstico Oftalmológico , Oftalmopatias/diagnóstico , Oftalmologia/métodos , Humanos
3.
J Med Imaging (Bellingham) ; 3(4): 044505, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28018938

RESUMO

Retinopathy of prematurity (ROP), a disorder of the retina occurring in preterm infants, is the leading cause of preventable childhood blindness. An active phase of ROP that requires treatment is associated with the presence of plus disease, which is diagnosed clinically in a qualitative manner by visual assessment of the existence of a certain level of increase in the thickness and tortuosity of retinal vessels. The present study performs computer-aided diagnosis (CAD) of plus disease via quantitative measurement of tortuosity in retinal fundus images of preterm infants. Digital image processing techniques were developed for the detection of retinal vessels and measurement of their tortuosity. The total lengths of abnormally tortuous vessels in each quadrant and the entire image were then computed. A minimum-length diagnostic-decision-making criterion was developed to assess the diagnostic sensitivity and specificity of the values obtained. The area ([Formula: see text]) under the receiver operating characteristic curve was used to assess the overall diagnostic accuracy of the methods. Using a set of 19 retinal fundus images of preterm infants with plus disease and 91 without plus disease, the proposed methods provided an overall diagnostic accuracy of [Formula: see text]. Using the total length of all abnormally tortuous vessel segments in an image, our techniques are capable of CAD of plus disease with high accuracy without the need for manual selection of vessels to analyze. The proposed methods may be used in a clinical or teleophthalmological setting.

4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 4338-42, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26737255

RESUMO

An increase in retinal vessel tortuosity can be indicative of the presence of various diseases including retinopathy of prematurity (ROP). Accurate detection and measurement of such changes could help in computer-aided diagnosis of plus disease, which warrants treatment of ROP. We present image processing methods for detection and segmentation of retinal vessels, quantification of vessel tortuosity, and diagnostic-decision-making criteria that incorporate the clinical definition of plus-diagnosis. The obtained results using 110 retinal fundus images of preterm infants (91 without plus and 19 with plus) provide high sensitivity = 0.89 (17/19) and excellent specificity = 0.95 (86/91) in the diagnosis of plus disease.


Assuntos
Fundo de Olho , Diagnóstico por Computador , Humanos , Processamento de Imagem Assistida por Computador , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Vasos Retinianos , Retinopatia da Prematuridade
5.
Comput Biol Med ; 66: 316-29, 2015 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-26457930

RESUMO

Changes in the characteristics of retinal vessels such as width and tortuosity can be signs of the presence of several diseases such retinopathy of prematurity (ROP) and diabetic retinopathy. Plus disease is an indicator of ROP which requires treatment and is signified by an increase in posterior venular width. In this work, we present image processing techniques for the detection, segmentation, tracking, and measurement of the width of the major temporal arcade (MTA), which is the thickest venular branch in the retina. Several image processing techniques have been employed, including the use of Gabor filters to detect the MTA, morphological image processing to obtain its skeleton, Canny's method to detect and select MTA vessel-edge candidates, least-squares fitting to interpolate the MTA edges, and geometrical procedures to measure the width of the MTA. The results, obtained using 110 retinal fundus images of preterm infants, indicate a statistically highly significant difference in MTA width of normal cases as compared to cases with plus disease (p<0.01). The results provide good accuracy in computer-aided diagnosis (CAD) of plus disease with an area under the receiver operating characteristic curve of 0.76. The proposed methods may be used in CAD of plus disease and timely treatment of ROP in a clinical or teleophthalmological setting.


Assuntos
Diagnóstico por Computador/métodos , Fundo de Olho , Vasos Retinianos/patologia , Retinopatia da Prematuridade/diagnóstico , Área Sob a Curva , Bases de Dados Factuais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Curva ROC
6.
Invest Ophthalmol Vis Sci ; 55(10): 6728-35, 2014 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-25168897

RESUMO

PURPOSE: We tested the hypothesis that the openness of the major temporal arcade (MTA) changes in the presence of plus disease, by quantification via parabolic modeling of the MTA, as well as measurement of an arcade angle for comparative analysis. Such analysis could assist in the detection and treatment of progressive retinopathy of prematurity. METHODS: Digital image processing techniques were applied for the detection and modeling of the MTA via a graphical user interface (GUI) to quantify the openness of the MTA. An arcade angle measure, based on a previously proposed method, also was obtained via the GUI for comparative analysis. The statistical significance of the differences between the plus and no-plus cases for each parameter was analyzed using the P value. The area (Az) under the receiver operating characteristic curve was used to assess the diagnostic performance of each feature. RESULTS: The temporal arcade angle measure and the openness parameter of the parabolic model were used to perform discrimination of plus versus no-plus cases. Using a set of 19 cases with plus and 91 with no plus disease, Az=0.70 was obtained using the results of dual-parabolic modeling in screening for plus disease. The arcade angle measure provided comparable results with Az=0.73. CONCLUSIONS: Using our proposed image analysis techniques and software, this study demonstrates, for the first time to our knowledge, that the openness of the MTA decreases in the presence of plus disease.


Assuntos
Diagnóstico por Computador/métodos , Processamento de Imagem Assistida por Computador , Doenças do Prematuro/diagnóstico , Recém-Nascido Prematuro , Vasos Retinianos/patologia , Retinopatia da Prematuridade/diagnóstico , Feminino , Fundo de Olho , Humanos , Recém-Nascido , Masculino , Curva ROC , Reprodutibilidade dos Testes
7.
Artigo em Inglês | MEDLINE | ID: mdl-25571217

RESUMO

Diagnosis of plus disease is crucial for timely treatment and management of retinopathy of prematurity. An indicator of the presence of plus disease is an increase in the tortuosity of blood vessels in the retina. In this work, we propose a new angle-variation-based measure for quantification of tortuosity in retinal fundus images of preterm infants. The methods include the use of Gabor filters to detect vessels as well as to obtain their orientation at each pixel. Morphological image processing methods are used to obtain a skeleton image of the vessels for measurement of tortuosity. Out of 11 vessel segments, marked by an expert ophthalmologist as showing high levels of tortuosity due to plus disease, all were correctly identified using the proposed methods.


Assuntos
Artérias/anormalidades , Processamento de Imagem Assistida por Computador , Recém-Nascido Prematuro/fisiologia , Instabilidade Articular/diagnóstico , Retina/patologia , Dermatopatias Genéticas/diagnóstico , Malformações Vasculares/diagnóstico , Bases de Dados como Assunto , Humanos , Recém-Nascido , Vasos Retinianos/patologia
8.
Artigo em Inglês | MEDLINE | ID: mdl-23366171

RESUMO

Monitoring the openness of the major temporal arcade (MTA) and how it changes over time could facilitate improved diagnosis and timely treatment of proliferative diabetic retinopathy (PDR). We present methods for user-guided modeling and measurement of the openness of the MTA based on a form of the generalized Hough transform for the detection of parabolas, and to compare it with a method of arcade angle measurement. The methods, implemented via a graphical user interface, were tested with retinal fundus images of 10 normal individuals and 15 patients with PDR. The results using the openness parameters of single- and dual-parabolic models as well as the arcade angle measurements indicate areas under the receiver operating characteristics of A(z)= 0.94, 0.87, and 0.84, respectively. The proposed methods should facilitate improved quantitative analysis of the architecture of the MTA, as well as assist in detection, diagnosis, and improved treatment of PDR.


Assuntos
Retinopatia Diabética/diagnóstico , Técnicas de Diagnóstico Oftalmológico , Fundo de Olho , Interpretação de Imagem Assistida por Computador/métodos , Retina/patologia , Algoritmos , Estudos de Casos e Controles , Bases de Dados Factuais , Retinopatia Diabética/patologia , Humanos , Processamento de Imagem Assistida por Computador , Fotografação , Curva ROC , Interface Usuário-Computador
9.
Artigo em Inglês | MEDLINE | ID: mdl-21095828

RESUMO

Contours of benign breast masses and malignant tumors in mammograms differ substantially in their shape and complexity; the former are usually round and smooth, whereas the latter are typically spiculated and irregular. We demonstrate the usefulness of fractal analysis via a frequency domain approach applied to one-dimensional signatures of the two-dimensional contours of breast masses. The 1/ƒ model was applied to power spectra of signatures to estimate the fractal dimension. Tests with a dataset of 111 contours, including those of 65 benign masses and 46 malignant tumors, indicated a high classification performance of 0.89 in terms of the area under the receiver operating characteristic curve.


Assuntos
Neoplasias da Mama/diagnóstico , Mamografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
10.
Artigo em Inglês | MEDLINE | ID: mdl-19965233

RESUMO

Quantitative analysis of the vascular architecture of the retina can help in monitoring the effects of retinopathy on the visual system. Retinopathy affects the blood vessels in the retina through modification of the shape, width, tortuosity, and the angle of insertion of the temporal arcade. Monitoring the openness of the temporal arcade and changes with treatment can facilitate improved diagnosis and optimized treatment. We propose methods for the detection and parametric modeling of the temporal arcade, including gradient operators and Gabor functions to detect retinal vessels, and the Hough transform to detect parabolic forms. Results obtained with 40 images of the retina indicate accurate to acceptable results for 24 images and partial fits of the parabolic models for 11 images.


Assuntos
Fundo de Olho , Retina/patologia , Doenças Retinianas/patologia , Vasos Retinianos/patologia , Algoritmos , Simulação por Computador , Processamento Eletrônico de Dados , Humanos , Processamento de Imagem Assistida por Computador , Recém-Nascido , Modelos Estatísticos , Reconhecimento Automatizado de Padrão , Retinopatia da Prematuridade/patologia , Software , Fatores de Tempo
11.
Artigo em Inglês | MEDLINE | ID: mdl-18003502

RESUMO

The monitoring of the effects of diabetes, hypertension, and premature birth on the visual system can be assisted by quantitative analysis of the vascular architecture of the retina. The application of image analysis techniques in ophthalmology becomes possible after the desired features have been detected through the use of an appropriate method. We propose image processing techniques for the detection of blood vessels in the retina. The methods include the design of a bank of directionally sensitive Gabor filters for several values of the scale and elongation parameters. Forty images of the retina from the DRIVE database were used to evaluate the performance of the methods. High efficiency in the detection of blood vessels with the area under the receiver operating characteristics curve of up to 0.96 was achieved.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Vasos Retinianos/patologia , Humanos , Doenças Retinianas/diagnóstico , Doenças Retinianas/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA