Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Am J Cardiol ; 102(7): 916-20, 2008 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-18805122

RESUMO

Retrospective studies have shown improvement in migraines after patent foramen ovale (PFO) closure. To date, no study has evaluated whether the completeness of closure affects headache status; therefore, the objective of this study was to evaluate the impact of residual right-to-left shunt (RLS) on migraine symptoms after transcatheter PFO closure in migraineurs with and without aura. This was a small-series, single-center, retrospective analysis of late follow-up data on 77 patients with presumed paradoxical embolism and migraine who underwent PFO closure for secondary stroke prevention. Power M-mode transcranial Doppler was used to assess RLS at baseline and 6 and 12 months after closure. A standardized migraine questionnaire was administered at baseline and 6, 12, and 24 months after closure. Fifty-five (71%) patients had migraine with aura. Final closure and migraine status were available for 67 patients; 23 (34%) had incomplete PFO closure, defined as 30 embolic tracks detected at final power M-mode transcranial Doppler examination (median 366 days, 95% confidence interval 332 to 474). Migraine relief (> or = 50% reduction in frequency) was independent of closure status (77% complete closure vs 83% incomplete closure, p = 0.76) at late follow-up (540 days, 95% confidence interval 537 to 711). Migraineurs with aura were 4.5 times more likely to experience migraine relief than migraineurs without aura. In conclusion, migraine relief may occur despite residual RLS after transcatheter PFO closure, which may suggest a reduction in RLS burden below a neuronal threshold that triggers migraine; however, this warrants further investigation. Migraine with aura may be an independent predictor of relief after PFO closure.


Assuntos
Forame Oval Patente/cirurgia , Transtornos de Enxaqueca/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Cateterismo Cardíaco , Ecocardiografia , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Transtornos de Enxaqueca/diagnóstico por imagem , Sistema de Registros , Estudos Retrospectivos , Estatísticas não Paramétricas , Resultado do Tratamento , Ultrassonografia Doppler Transcraniana
2.
Am J Cardiol ; 99(9): 1312-5, 2007 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-17478164

RESUMO

The purpose of the present study was to assess clinical outcomes and closure status after the transcatheter closure of patent foramen ovale. Two hundred thirty-seven consecutive patients (mean age 53 +/- 15 years; 48% men) who underwent patent foramen ovale closure for the prevention of recurrent stroke were evaluated. Primary end points were death, recurrent stroke, and residual right-to-left shunt (RLS). Closure status was monitored at 1, 6, 12, 24, 36, and 48 months after the index procedure by power M-mode transcranial Doppler and was defined by the number of embolic tracks detected after the release of a sustained, calibrated Valsalva maneuver. During a mean follow-up period of 568 +/- 364 days, the cumulative event rate for recurrent stroke (n = 8) was 3.4%, for an estimated event-free survival of 0.94 (SE 0.03). There was a significant difference in the estimated probability of recurrent stroke for patients grouped by age (< or =55 years 1.4% vs >55 years 6.6%, p = 0.03). There were 7 deaths (3.0%), 1 secondary to and 6 unrelated to recurrent strokes, and 3 surgical explantations (1.3%). Event-free survival, defined as freedom from death, stroke, or explantation, was 0.92 (SE 0.02). The magnitude of RLS was significantly less at late follow-up compared with baseline (grade 4.6 +/- 0.7 vs 1.8 +/- 1.6, p <0.001). Complete closure or minimal residual RLS (grade 0 to II) was achieved in 66% of patients. Device type (CardioSEAL or Amplatzer) did not affect the risk for adverse events or the presence of large residual RLS. In conclusion, transcatheter patent foramen ovale closure is associated with a low recurrent stroke rate in long-term follow-up.


Assuntos
Oclusão com Balão , Cateterismo Cardíaco , Embolia Paradoxal/prevenção & controle , Comunicação Interatrial/terapia , Embolia Intracraniana/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Adulto , Idoso , Intervalo Livre de Doença , Embolia Paradoxal/etiologia , Feminino , Seguimentos , Comunicação Interatrial/complicações , Humanos , Embolia Intracraniana/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Prevenção Secundária , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
3.
J Invasive Cardiol ; 29(3): E30-E36, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28255106

RESUMO

Patients who present with both severe mitral and tricuspid regurgitation who are symptomatic despite optimal medical therapy and at prohibitive risk for surgery pose a significant therapeutic challenge. The MitraClip device (Abbott Vascular) is approved for percutaneous mitral valve repair in high-risk and non-operative patients, and has also been used for tricuspid valve repair. Imaging support for percutaneous edge-to-edge tricuspid valve repair has not been reported and is a vital part of the procedure. Here, we present a periprocedural imaging strategy for percutaneous tricuspid valve repair with the MitraClip device using a bicuspidization technique.


Assuntos
Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Tricúspide , Valva Tricúspide/diagnóstico por imagem , Idoso , Técnicas de Imagem Cardíaca , Desenho de Equipamento , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Assistência Perioperatória/métodos , Risco Ajustado/métodos , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia
4.
J Am Coll Cardiol ; 45(4): 493-5, 2005 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-15708692

RESUMO

OBJECTIVES: The purpose of this study was to determine the effects of transcatheter patent foramen ovale (PFO) closure on migraine frequency in patients with paradoxical cerebral embolism. BACKGROUND: The prevalence of migraine headache is higher in cryptogenic stroke patients with PFO than in the general population. Previous studies have suggested that closure of the PFO may reduce migrainous symptoms. METHODS: Between April 2001 and December 2003, 162 consecutive patients with paradoxical cerebral embolism underwent transcatheter PFO closure for prevention of recurrent cryptogenic stroke or transient ischemic attack. A one-year retrospective analysis of migraine symptoms before and after PFO closure was performed. RESULTS: Active migraine was present in 35% (57 of 162) of patients, and 68% (39 of 57) experienced migrainous aura; 50 patients were available for analysis at one year. Complete resolution of migraine symptoms occurred in 56% (28 of 50) of patients, and 14% (7 of 50) of patients reported a significant (>or=50%) reduction in migraine frequency. Patients reported an 80% reduction in the mean number of migraine episodes per month after PFO closure (6.8 +/- 9.6 before closure vs. 1.4 +/- 3.4 after closure, p < 0.001). Results were independent of completeness of PFO closure at one year. CONCLUSIONS: In patients with paradoxical cerebral embolism, migraine headaches are more frequent than in the general population, and transcatheter closure of the PFO results in complete resolution or marked reduction in frequency of migraine headache.


Assuntos
Cateterismo Cardíaco , Comunicação Interatrial/complicações , Comunicação Interatrial/cirurgia , Transtornos de Enxaqueca/etiologia , Transtornos de Enxaqueca/cirurgia , Embolia Paradoxal/complicações , Feminino , Seguimentos , Humanos , Embolia Intracraniana/complicações , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
J Neuroimaging ; 14(4): 342-9, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15358955

RESUMO

BACKGROUND AND PURPOSE: Transcatheter closure of patent foramen ovale (PFO) can benefit from a less invasive diagnostic method than transesophageal echocardiography (TEE). Thirty-three gate power m-mode transcranial Doppler (pmTCD) was evaluated for its accuracy in diagnosis of PFO and utility in evaluating residual intracardiac right-to-left shunt (RLS) following transcatheter closure. METHODS: The sensitivity of pmTCD and single-gate TCD (sgTCD) to detect contrast bubble emboli through RLS was compared during transcatheter PFO closure. During 100 preclosure diagnostic evaluations and in 81 postclosure assessments, embolic tracks on pmTCD were counted following intravenous contrast injections and were graded using a 6-level logarithmic scale. The accuracy of TEE and pmTCD was separately compared to PFO anatomical findings during transcatheter closures. RESULTS: There were significantly more microemboli detectable on pmTCD (322 +/- 166; 95% confidence interval [CI], 388-257) than on sgTCD (186 +/- 109; 95% CI, 229-143; P < .001). McNemar change tests suggest that the diagnostic capabilities of pmTCD and TEE for detecting PFO are comparable and correspond to the anatomical findings determined during cardiac catheterization (P = .69 and .45, respectively). During 6-month postclosure evaluation (mean = 185 days), 66% of the patients demonstrated successful closure without significant RLS (ie, grades 0, I, or II), and 34% were found to have incomplete closure with significant RLS (ie, grades III, IV, or V). CONCLUSIONS: pmTCD provides greater sensitivity to contrast bubble emboli than does sgTCD. Among candidates for transcatheter closure, pmTCD provides an improved noninvasive method for diagnosing PFO and evaluating transcatheter closure.


Assuntos
Cateterismo Cardíaco , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia , Ultrassonografia Doppler Transcraniana/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Embolia/diagnóstico por imagem , Embolia/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
J Headache Pain ; 8(4): 209-16, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17901924

RESUMO

The objective of the study was to assess differences in proportion of large right-to-left shunt (RLS) and atrial septal characteristics between migraineurs and non-migraineurs referred for transcatheter closure of patent foramen ovale (PF0). This retrospective study took place in a large metropolitan medical centre. The patients were migraineurs with aura (n=52), migraineurs without aura (n=19) and non-migraineurs (n=149). RLS was evaluated before closure using bilateral power m-mode transcranial Doppler at rest and after calibrated, sustained Valsalva manoeuvre, and graded with a validated 0-5 scale. Intracardiac echocardiography was used to assess atrial septal characteristics. Migraineurs had a higher proportion of large RLS (Grade IV or V) than nonmigraineurs at rest and after calibrated Valsalva (rest, p=0.04; Valsalva, p=0.01). Atrial septal characteristics were similar between groups. Migraine is associated with larger RLS at rest and strain; however migraine status does not predict PFO characteristics.


Assuntos
Septo Interatrial/fisiopatologia , Forame Oval Patente/complicações , Forame Oval Patente/fisiopatologia , Transtornos de Enxaqueca/etiologia , Transtornos de Enxaqueca/fisiopatologia , Fluxo Sanguíneo Regional/fisiologia , Adulto , Idoso , Septo Interatrial/patologia , Encéfalo/irrigação sanguínea , Encéfalo/fisiopatologia , Procedimentos Cirúrgicos Cardíacos , Circulação Cerebrovascular/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transtornos de Enxaqueca/diagnóstico por imagem , Enxaqueca com Aura/diagnóstico por imagem , Enxaqueca com Aura/etiologia , Enxaqueca com Aura/fisiopatologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento , Ultrassonografia Doppler Transcraniana , Manobra de Valsalva/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA