RESUMO
Chronic thromboembolic pulmonary disease (CTEPD) is an important late complication of acute pulmonary embolism, in which the thrombi transform into fibrous tissue, become integrated into the vessel wall, and lead to chronic obstructions. CTEPD is differentiated into cases without pulmonary hypertension (PH), characterized by a mean pulmonary arterial pressure up to 20âmmHg and a form with PH. Then, it is still referred to as chronic thromboembolic pulmonary hypertension (CTEPH).When there is suspicion of CTEPH, initial diagnostic tests should include echocardiography and ventilation/perfusion scan to detect perfusion defects. Subsequently, referral to a CTEPH center is recommended, where further imaging diagnostics and right heart catheterization are performed to determine the appropriate treatment.Currently, three treatment modalities are available. The treatment of choice is pulmonary endarterectomy (PEA). For non-operable patients or patients with residual PH after PEA, PH-targeted medical therapy, and the interventional procedure of balloon pulmonary angioplasty (BPA) are available. Increasingly, PEA, BPA, and pharmacological therapy are combined in multimodal concepts.Patients require post-treatment follow-up, preferably at (CTE)PH centers. These centers are required to perform a minimum number of PEA surgeries (50/year) and BPA interventions (100/year).
Assuntos
Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Doença Crônica , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/terapia , Pulmão , Artéria Pulmonar/cirurgiaRESUMO
BACKGROUND: Titanium dioxide nanoparticles (TiO2 NPs) have a wide range of applications in several industrial and biomedical domains. Based on the evidence, the workers exposed to inhaled nanosized TiO2 powder are more susceptible to the risks of developing respiratory diseases. Accordingly, this issue has increasingly attracted the researchers' interest in understanding the consequences of TiO2 NPs exposure. Regarding this, the present study was conducted to analyze the local effects of TiO2 NPs on allergic airway inflammation and their uptake in a mouse model of ovalbumin (OVA)-induced allergic airway inflammation. METHODS: For the purpose of the study, female BALB/c mice with or without asthma were intranasally administered with TiO2 NPs. The mice were subjected to histological assessment, lung function testing, scanning electron microscopy (SEM), inductively coupled plasma mass spectrometry (ICP-MS), and NP uptake measurement. In addition, T helper (Th) 1/Th2 cytokines were evaluated in the lung homogenate using the enzyme-linked immunosorbent assay. RESULTS: According to the results, the mice receiving OVA alone or OVA plus TiO2 NPs showed eosinophilic infiltrates and mucus overproduction in the lung tissues, compared to the controls. Furthermore, a significant elevation was observed in the circulating Th2 cytokines, including interleukin (IL)-4, IL-5, and IL-13 after NP exposure. The TiO2 NPs were taken up by alveolar macrophages at different time points. As the results of the SEM and ICP-MS indicated, TiO2 NPs were present in most of the organs in both asthmatic and non-asthmatic mice. CONCLUSION: Based on the findings of the current study, intranasally or inhalation exposure to high-dose nanosized TiO2 particles appears to exacerbate the allergic airway inflammation and lead to systemic uptake in extrapulmonary organs. These results indicate the very important need to investigate the upper limit of intranasally or inhalation exposure to nanosized TiO2 particles in occupational and environmental health policy.
Assuntos
Asma/induzido quimicamente , Asma/patologia , Nanopartículas/toxicidade , Titânio/toxicidade , Administração Intranasal , Animais , Hiper-Reatividade Brônquica/induzido quimicamente , Hiper-Reatividade Brônquica/fisiopatologia , Líquido da Lavagem Broncoalveolar/citologia , Citocinas/metabolismo , Eosinófilos/imunologia , Feminino , Exposição por Inalação , Camundongos , Camundongos Endogâmicos BALB C , Nanopartículas/administração & dosagem , Ovalbumina/imunologia , Testes de Função Respiratória , Linfócitos T Auxiliares-Indutores/metabolismo , Titânio/administração & dosagemRESUMO
BACKGROUND: The combination of chronic obstructive pulmonary disease (COPD) and chronic kidney disease (CKD) is associated with a higher prevalence of comorbidities and increased mortality. The impact of kidney function on patient-centered outcomes in COPD has not been evaluated. METHODS: Patients from the German COPD and Systemic Consequences - Comorbidities Network (COSYCONET) cohort COPD were analysed. CKD was diagnosed if the estimated glomerular filtration rate (eGFR) measurements were < 60 mL/min/1.73m2 at study inclusion and six month later. The effect of CKD, on comorbidities, symptoms [modified British Medical Research Council dyspnoea scale], physical capacity [six-minute walk test, and timed up and go] and St George's Respiratory Questionnaire were analysed. Restricted cubic spline models were used to evaluate a nonlinear relationship between eGFR with patient-centered outcomes, cox survival analysis was applied to evaluate mortality. RESULTS: 2274 patients were analysed, with CKD diagnosed in 161 (7.1%). Spline models adjusted for age, gender, BMI, FEV1 and cardiovascular comorbidities revealed independent associations between eGFR with modified British Medical Research Council dyspnoea scale, St George's Respiratory Questionnaire, (p < 0.001 and p = 0.011), six-minute walk test (p = 0.015) and timed up and go (p < 0.001). CKD was associated with increased mortality, independently from for other cardiovascular comorbidities (hazard ratio 2.3; p < 0.001). CONCLUSION: These data show that CKD is a relevant comorbidity in COPD patients which impacts on patient-centered outcomes and mortality. TRIAL REGISTRATION: NCT01245933.
Assuntos
Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Idoso , Estudos de Coortes , Comorbidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Insuficiência Renal Crônica/fisiopatologia , Testes de Função Respiratória/métodos , Teste de Caminhada/métodosRESUMO
Nanotechnology is showing promise in many medical applications such as drug delivery and hyperthermia. Nanoparticles administered to the respiratory tract cause local reactions and cross the blood-air barrier, thereby providing a means for easy systemic administration but also a potential source of toxicity. Little is known about how these effects are influenced by preexisting airway diseases such as asthma. Here, BALB/c mice are treated according to the ovalbumin (OVA) asthma protocol to promote allergic airway inflammation. Dispersions of polyethylene-glycol-coated (PEGylated) and citrate/tannic-acid-coated (citrated) 5 nm gold nanoparticles are applied intranasally to asthma and control groups, and (i) airway resistance and (ii) local tissue effects are measured as primary endpoints. Further, nanoparticle uptake into extrapulmonary organs is quantified by inductively coupled plasma mass spectrometry. The asthmatic precondition increases nanoparticle uptake. Moreover, systemic uptake is higher for PEGylated gold nanoparticles compared to citrated nanoparticles. Nanoparticles inhibit both inflammatory infiltrates and airway hyperreactivity, especially citrated gold nanoparticles. Although the antiinflammatory effects of gold nanoparticles might be of therapeutic benefit, systemic uptake and consequent adverse effects must be considered when designing and testing nanoparticle-based asthma therapies.
Assuntos
Asma/tratamento farmacológico , Ouro/química , Nanopartículas Metálicas/química , Nanopartículas Metálicas/uso terapêutico , Nanotecnologia/métodos , Animais , Asma/induzido quimicamente , Espectrometria de Massas , Camundongos , Camundongos Endogâmicos BALB C , Ovalbumina/toxicidade , Polietilenoglicóis/químicaRESUMO
This viewpoint reviews the perspectives for dermatology as a specialty to go beyond the substantial impact of smoking on skin disease and leverage the impact of skin changes on a person's self-concept and behavior in the design of effective interventions for smoking prevention and cessation.
Assuntos
Dermatologistas/normas , Aplicativos Móveis/estatística & dados numéricos , Envelhecimento da Pele/fisiologia , Prevenção do Hábito de Fumar/métodos , Fumar/terapia , HumanosRESUMO
OBJECTIVES: Mast cells (MCs) and nerves play an important role in allergic rhinitis (AR), but little is known about their crosstalk in AR. The aim of this study was to investigate MC-nerve interaction in the human nasal mucosa during AR. METHODS: The association between MCs and nerves, the expression of neuropeptide receptors (neurokinin 1 receptor [NK1R], neurokinin 2 receptor [NK2R], calcitonin gene-related peptide receptor [CGRPR], and MrgX2) on MCs, and protease-activated receptor 2 (PAR2) and tyrosine receptor kinase A (TrkA) on nerve fibres in the human nasal mucosa were investigated with immunofluorescence and real-time PCR. RESULTS: The association between MCs and nerves was found to be significantly increased, although the numbers of MCs and nerve fibres were unchanged during AR. MCs expressing tryptase-chymase (MCtc) were frequently associated with nerve fibres and these contacts increased significantly in AR. Neuropeptide receptors NK1R, NK2R, and CGRPR were firstly found to be largely localised on MCs. The number of MCs expressing NK1R and NK2R, but not CGRPR, was significantly increased in AR. Interestingly, MCtc mostly expressed these neuropeptide receptors. The newly discovered tachykinin receptor MrgX2 was not expressed on nasal MCs, but was expressed on gland cells and increased in AR. Additionally, tachykinergic nerve fibres were found to express PAR2 or TrkA as receptors for MCs. CONCLUSIONS: This study revealed for the first time an increase of MC-nerve association and neuropeptide receptor expression on MCs during AR as well as nerve fibres containing receptors for MCs. These results suggest that targeting or controlling airway sensory nerve function as a modulator of MCs may prevent allergic airway inflammation such as AR.
Assuntos
Mastócitos/metabolismo , Mucosa Nasal/inervação , Fibras Nervosas/metabolismo , Receptores de Neuropeptídeos/metabolismo , Rinite Alérgica/patologia , Adolescente , Adulto , Quimases/metabolismo , Feminino , Regulação da Expressão Gênica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Mucosa Nasal/metabolismo , Receptores de Peptídeo Relacionado com o Gene de Calcitonina/metabolismo , Receptores da Neurocinina-1/metabolismo , Receptores da Neurocinina-2/metabolismo , Receptores de Neuropeptídeos/genética , Substância P/metabolismo , Fatores de Transcrição/metabolismo , Triptases/metabolismo , Ubiquitina Tiolesterase/metabolismo , Adulto JovemRESUMO
Like two sides of the same coin, nanotechnology can be both boon and bane for respiratory medicine. Nanomaterials open new ways in diagnostics and treatment of lung diseases. Nanoparticle based drug delivery systems can help against diseases such as lung cancer, tuberculosis, and pulmonary fibrosis. Moreover, nanoparticles can be loaded with DNA and act as vectors for gene therapy in diseases like cystic fibrosis. Even lung diagnostics with computer tomography (CT) or magnetic resonance imaging (MRI) profits from new nanoparticle based contrast agents. However, the risks of nanotechnology also have to be taken into consideration as engineered nanomaterials resemble natural fine dusts and fibers, which are known to be harmful for the respiratory system in many cases. Recent studies have shown that nanoparticles in the respiratory tract can influence the immune system, can create oxidative stress and even cause genotoxicity. Another important aspect to assess the safety of nanotechnology based products is the absorption of nanoparticles. It was demonstrated that the amount of pulmonary nanoparticle uptake not only depends on physical and chemical nanoparticle characteristics but also on the health status of the organism. The huge diversity in nanotechnology could revolutionize medicine but makes safety assessment a challenging task.
Assuntos
Pneumopatias/terapia , Nanotecnologia/tendências , Pneumologia/tendências , Animais , Sistemas de Liberação de Medicamentos/métodos , Sistemas de Liberação de Medicamentos/tendências , Técnicas de Transferência de Genes/tendências , Humanos , Pneumopatias/genética , Nanofibras/administração & dosagem , Nanopartículas/administração & dosagem , Nanotecnologia/métodos , Estrutura Secundária de Proteína , Pneumologia/métodos , Medicamentos para o Sistema Respiratório/administração & dosagemRESUMO
Chronic thromboembolic pulmonary hypertension (CTEPH) is a rare disease, but an important late sequela after acute pulmonary embolism. Therefore, follow-up after at least three months of sufficient anticoagulation is recommended. Patients with suspected CTEPH should be referred to specialized CTEPH centers for further evaluation and treatment.Three treatment modalities are available: pulmonary endarterectomy (PEA), balloon pulmonary angioplasty (BPA) and pulmonary hypertension-targeted drugs. The indication for surgery depends mainly on the localization of the pulmonary arterial obstructions. Severe comorbidities as well as advanced age need individual evaluation, but do not present strict exclusion criteria. Multimodal treatments are common practice in inoperable CTEPH. However, treatment decision making in an experienced multidisciplinary team is mandatory.
Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Doença Crônica , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/terapia , Artéria Pulmonar , EndarterectomiaRESUMO
Extracorporeal membrane oxygenation (ECMO) is an important rescue therapy method for the treatment of severe hypoxic lung injury. In some cases, oxygen saturation and oxygen partial pressure in the arterial blood are low despite ECMO therapy. There are case reports in which patients with such instances of refractory hypoxemia received a second membrane lung, either in series or in parallel, to overcome the hypoxemia. It remains unclear whether the parallel or serial connection is more effective. Therefore, we used an improved version of our full-flow ECMO mock circuit to test this. The measurements were performed under conditions in which the membrane lungs were unable to completely oxygenate the blood. As a result, only the photometric pre- and post-oxygenator saturations, blood flow and hemoglobin concentration were required for the calculation of oxygen transfer rates. The results showed that for a pre-oxygenator saturation of 45% and a total blood flow of 10 L/min, the serial connection of two identical 5 L rated oxygenators is 17% more effective in terms of oxygen transfer than the parallel connection. Although the idea of using a second membrane lung if refractory hypoxia occurs is intriguing from a physiological point of view, due to the invasiveness of the solution, further investigations are needed before this should be used in a wider clinical setting.
RESUMO
In late 2020, during the second wave of COVID-19 in Germany, we started using the MobyBox, which is a novel fully pneumatically driven ECMO device, on a regular basis to meet the increasing demand for ECMO therapy. In this case series, we performed a retrospective chart review of seven patients with severe COVID-19-related acute respiratory distress syndrome (ARDS) requiring veno-venous (vv)-ECMO support with the MobyBox. During ECMO treatments we have observed no disadvantages in comparison to conventional ECMO systems. There were no system failures or adverse events directly attributable to the MobyBox system. Our data support that providing vv-ECMO with the MobyBox device is safe and feasible. Furthermore, our findings suggest that the MobyBox device might represent an advantage in terms of biocompatibility. Therefore, more data on this issue is needed to better understand how the pneumatically driven pump affects cellular blood components.
Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Síndrome do Desconforto Respiratório , Adulto , Oxigenação por Membrana Extracorpórea/efeitos adversos , Humanos , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/terapia , Estudos RetrospectivosRESUMO
Extracorporeal membrane oxygenation (ECMO) has become an important therapeutic approach in the COVID-19 pandemic. The development and research in this field strongly relies on animal models; however, efforts are being made to find alternatives. In this work, we present a new mock circuit for ECMO that allows measurements of the oxygen transfer rate of a membrane lung at full ECMO blood flow. The mock utilizes a large reservoir of heparinized porcine blood to measure the oxygen transfer rate of the membrane lung in a single passage. The oxygen transfer rate is calculated from blood flow, hemoglobin value, venous saturation, and post-membrane arterial oxygen pressure. Before the next measuring sequence, the blood is regenerated to a venous condition with a sweep gas of nitrogen and carbon dioxide. The presented mock was applied to investigate the effect of a recirculation loop on the oxygen transfer rate of an ECMO setup. The recirculation loop caused a significant increase in post-membrane arterial oxygen pressure (paO2). The effect was strongest for the highest recirculation flow. This was attributed to a smaller boundary layer on gas fibers due to the increased blood velocity. However, the increase in paO2 did not translate to significant increases in the oxygen transfer rate because of the minor significance of physically dissolved oxygen for gas transfer. In conclusion, our results regarding a new ECMO mock setup demonstrate that recirculation loops can improve ECMO performance, but not enough to be clinically relevant.
RESUMO
Low flow extracorporeal carbon dioxide removal (ECCO2R) is a promising approach to correct hypercapnic lung failure, facilitate lung protective ventilation in acute respiratory distress syndrome and to possibly prevent the application of invasive ventilation. However, the predominant availability of adult membrane lungs (MLs) at most intensive care units are burdens for low flow ECCO2R that intends to reduce cannula size and promote the mobility of the patients. Herein, in a mock setup, we combine the idea of a low flow ECCO2R and the use of adult MLs by installing a recirculation channel into the circuit and comparing the new setup to an already clinically established setup, "the Homburg lung." Furthermore, to make stronger reference to hypercapnic respiratory failure, we investigate the influence of CO2 partial pressure in blood on CO2 removal of both setups. A linear association between CO2 partial pressure in blood and CO2 removal of the ML in the physiologically relevant range was observed. To understand this linear dependence, a simplified mathematical model was proposed. Our new ECCO2R mock setup combines the idea of a low flow ECCO2R and an adult size ML. It shows a reasonable alternative to the current available low flow setups based on pediatric MLs.
Assuntos
Síndrome do Desconforto Respiratório , Insuficiência Respiratória , Adulto , Dióxido de Carbono , Criança , Circulação Extracorpórea , Humanos , Hipercapnia , Respiração Artificial , Síndrome do Desconforto Respiratório/terapiaRESUMO
As a consequence of the continued Covid-19 lockdown in Germany, in-hospital teaching for medical students was impossible. While lectures and other theoretical training were relatively easily converted into online sessions using platforms such as Moodle, Zoom and Microsoft Teams, this was not the case for practical skills and clinical interventions, such as bronchoscopy or colonoscopy. This study describes a workaround that was implemented at the Saarland University Hospital utilizing virtual reality equipment to convey the impressions of shadowing clinical procedures to the students without physical presence. To achieve this, 3D 180° videos of key clinical interventions of various internal medicine specialities were recorded, cut, and censored. The videos were uploaded to the e-learning YouTube channel of our institution and shared with the students via the private share function. The students could choose whether to use a VR-viewer to watch the videos immersively or to watch them without a viewer on a screen non-immersively. At the end of the course after 1 week, the students completed a questionnaire anonymously focusing on learning-success regarding the presented topics, a self-assessment, and an evaluation of the course. A total of 27 students watched the videos with a VR-Viewer and 74 watched non-immersively. Although the VR-viewer group self-assessed their expertise higher, there was no significant difference between the two groups in the learning-success test score. However, students in the VR-viewer group rated the learning atmosphere, comprehensibility, and overall recommendation of the course significantly higher. They also agreed significantly more to the statement, that they gained a better conception of the presented procedures, and that virtual reality might be an appropriate tool for online teaching. Video-assisted teaching facilitates learning and might be a valuable add-on to conventional teaching.Abbreviations: Covid-19: severe acute respiratory syndrome coronavirus 2; 3D: three-dimensional; 2D: Two-dimensional; VR: virtual reality.
Assuntos
COVID-19 , Estudantes de Medicina , Realidade Virtual , Controle de Doenças Transmissíveis , Alemanha , Hospitais , Humanos , Inquéritos e QuestionáriosRESUMO
Coronavirus disease 2019 (COVID-19) has drastically increased the number of patients requiring extracorporeal life support. We investigate the efficacy and safety of low-dose recombinant tissue-type plasminogen activator (rtPA) injection into exhausted oxygenators to delay exchange in critically ill COVID-19 patients on veno-venous extracorporeal membrane oxygenation (V-V ECMO). Small doses of rtPA were injected directly into the draining section of a V-V ECMO circuit. We compared transmembrane pressure gradient, pump head efficiency, membrane arterial partial oxygen pressure, and membrane arterial partial carbon dioxide pressure before and after the procedure. Bleeding was compared with a matched control group of 20 COVID-19 patients on V-V ECMO receiving standard anticoagulation. Four patients received 16 oxygenator instillations with rtPA at 5, 10, or 20 mg per dose. Administration of rtPA significantly reduced transmembrane pressure gradient (Δ pm = 54.8 ± 18.1 mmHg before vs . 38.3 ± 13.3 mmHg after, p < 0.001) in a dose-dependent manner (Pearson's R -0.63, p = 0.023), allowing to delay oxygenator exchange, thus reducing the overall number of consumed oxygenators. rtPA increased blood flow efficiency η (1.20 ± 0.28 ml/revolution before vs . 1.24 ± 0.27 ml/r, p = 0.002). Lysis did not affect membrane blood gases or systemic coagulation. Minor bleeding occurred in 2 of 4 patients (50%) receiving oxygenator lysis as well as 19 of 20 control patients (95%). Lysis of ECMO oxygenators effectively delays oxygenator exchange, if exchange is indicated by an increase in transmembrane pressure gradient. Application of lysis did not result in higher bleeding incidences compared with anticoagulated patients on V-V ECMO for COVID-19.
Assuntos
Tratamento Farmacológico da COVID-19 , Oxigenação por Membrana Extracorpórea , Oxigenadores de Membrana , Ativador de Plasminogênio Tecidual , Gasometria , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenação por Membrana Extracorpórea/métodos , Humanos , Ativador de Plasminogênio Tecidual/uso terapêuticoRESUMO
Extracorporeal carbon dioxide removal (ECCO2R) is an important technique to treat critical lung diseases such as exacerbated chronic obstructive pulmonary disease (COPD) and mild or moderate acute respiratory distress syndrome (ARDS). This study applies our previously presented ECCO2R mock circuit to compare the CO2 removal capacity of circular versus parallel-plated membrane lungs at different sweep gas flow rates (0.5, 2, 4, 6 L/min) and blood flow rates (0.3 L/min, 0.9 L/min). For both designs, two low-flow polypropylene membrane lungs (Medos Hilte 1000, Quadrox-i Neonatal) and two mid-flow polymethylpentene membrane lungs (Novalung Minilung, Quadrox-iD Pediatric) were compared. While the parallel-plated Quadrox-iD Pediatric achieved the overall highest CO2 removal rates under medium and high sweep gas flow rates, the two circular membrane lungs performed relatively better at the lowest gas flow rate of 0.5 L/min. The low-flow Hilite 1000, although overall better than the Quadrox i-Neonatal, had the most significant advantage at a gas flow of 0.5 L/min. Moreover, the circular Minilung, despite being significantly less efficient than the Quadrox-iD Pediatric at medium and high sweep gas flow rates, did not show a significantly worse CO2 removal rate at a gas flow of 0.5 L/min but rather a slight advantage. We suggest that circular membrane lungs have an advantage at low sweep gas flow rates due to reduced shunting as a result of their fiber orientation. Efficiency for such low gas flow scenarios might be relevant for possible future portable ECCO2R devices.
RESUMO
BACKGROUND: Extracorporeal carbon dioxide removal (ECCO2R) is a promising yet limited researched therapy for hypercapnic respiratory failure in acute respiratory distress syndrome and exacerbated chronic obstructive pulmonary disease. Herein, we describe a new mock circuit that enables experimental ECCO2R research without animal models. In a second step, we use this model to investigate three experimental scenarios of ECCO2R: (I) the influence of hemoglobin concentration on CO2 removal. (II) a potentially portable ECCO2R that uses air instead of oxygen, (III) a low-flow ECCO2R that achieves effective CO2 clearance by recirculation and acidification of the limited blood volume of a small dual lumen cannula (such as a dialysis catheter). RESULTS: With the presented ECCO2R mock, CO2 removal rates comparable to previous studies were obtained. The mock works with either fresh porcine blood or diluted expired human packed red blood cells. However, fresh porcine blood was preferred because of better handling and availability. In the second step of this work, hemoglobin concentration was identified as an important factor for CO2 removal. In the second scenario, an air-driven ECCO2R setup showed only a slightly lower CO2 wash-out than the same setup with pure oxygen as sweep gas. In the last scenario, the low-flow ECCO2R, the blood flow at the test membrane lung was successfully raised with a recirculation channel without the need to increase cannula flow. Low recirculation ratios resulted in increased efficiency, while high recirculation ratios caused slightly reduced CO2 removal rates. Acidification of the CO2 depleted blood in the recirculation channel caused an increase in CO2 removal rate. CONCLUSIONS: We demonstrate a simple and cost effective, yet powerful, "in-vitro" ECCO2R model that can be used as an alternative to animal experiments for many research scenarios. Moreover, in our approach parameters such as hemoglobin level can be modified more easily than in animal models.
RESUMO
High resting heart rate (RHR) is associated with higher mortality in the general population and in cardiovascular disease. Less is known about the association of RHR with outcome in chronic obstructive pulmonary disease (COPD). In particular, the time-updated RHR (most recent value before the event) appears informative. This is the first study to investigate the association of time-updated RHR with mortality in COPD. We compared the baseline and time-updated RHR related to survival in 2218 COPD patients of the German COSYCONET cohort (COPD and Systemic Consequences-Comorbidities Network). Patients with a baseline RHR > 72 beats per minute (bmp) had a significantly (p = 0.049) higher all-cause mortality risk (adjusted hazard ratio (HR) of 1.37 (1.00-1.87) compared to baseline RHR ≤ 72 bpm. The time-updated RHR > 72 bpm was markedly superior (HR 1.79, 1.30-2.46, p = 0.001). Both, increased baseline and time-updated RHR, were independently associated with low FEV1, low TLCO, a history of diabetes, and medication with short-acting beta agonists (SABAs). In conclusion, increased time-updated RHR is associated with higher mortality in COPD independent of other predictors and superior to baseline RHR. Increased RHR is linked to lung function, comorbidities and medication. Whether RHR is an effective treatment target in COPD, needs to be proven in controlled trials.
Assuntos
Frequência Cardíaca/fisiologia , Doença Pulmonar Obstrutiva Crônica/mortalidade , Descanso/fisiologia , Idoso , Causas de Morte/tendências , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de TempoRESUMO
BACKGROUND: Most smokers start smoking during their early adolescence, often with the idea that smoking is glamorous. Interventions that harness the broad availability of mobile phones as well as adolescents' interest in their appearance may be a novel way to improve school-based prevention. A recent study conducted in Germany showed promising results. However, the transfer to other cultural contexts, effects on different genders, and implementability remains unknown. OBJECTIVE: In this observational study, we aimed to test the perception and implementability of facial-aging apps to prevent smoking in secondary schools in Brazil in accordance with the theory of planned behavior and with respect to different genders. METHODS: We used a free facial-aging mobile phone app ("Smokerface") in three Brazilian secondary schools via a novel method called mirroring. The students' altered three-dimensional selfies on mobile phones or tablets and images were "mirrored" via a projector in front of their whole grade. Using an anonymous questionnaire, we then measured on a 5-point Likert scale the perceptions of the intervention among 306 Brazilian secondary school students of both genders in the seventh grade (average age 12.97 years). A second questionnaire captured perceptions of medical students who conducted the intervention and its conduction per protocol. RESULTS: The majority of students perceived the intervention as fun (304/306, 99.3%), claimed the intervention motivated them not to smoke (289/306, 94.4%), and stated that they learned new benefits of not smoking (300/306, 98.0%). Only a minority of students disagreed or fully disagreed that they learned new benefits of nonsmoking (4/306, 1.3%) or that they themselves were motivated not to smoke (5/306, 1.6%). All of the protocol was delivered by volunteer medical students. CONCLUSIONS: Our data indicate the potential for facial-aging interventions to reduce smoking prevalence in Brazilian secondary schools in accordance with the theory of planned behavior. Volunteer medical students enjoyed the intervention and are capable of complete implementation per protocol.
RESUMO
INTRODUCTION: Most smokers start smoking during their early adolescence, often with the idea that smoking is glamorous; the dramatic health consequences are too far in the future to fathom. We recently designed and tested an intervention that takes advantage of the broad availability of mobile phones as well as adolescents' interest in their appearance. A free photoageing mobile app (Smokerface) was implemented by medical students in secondary schools via a novel method called mirroring. The pupils' altered three-dimensional selfies on tablets were 'mirrored' via a projector in front of their whole grade. This is the first randomised trial to measure the effectiveness of the mirroring approach on smoking behaviour in secondary schools. METHODS AND ANALYSIS: The mirroring intervention, which lasts 45 min, is implemented by Brazilian medical students in at least 35 secondary school classes with 21 participants each (at least 35 classes with 21 participants for control) in February 2018 in the city of Itauna, Brazil. External block randomisation via computer is performed on the class level with a 1:1 allocation. In addition to sociodemographic data, smoking behaviour is measured via a paper-pencil questionnaire before, 3 and 6 months postintervention plus a random carbon monoxide breathing test at baseline and end line. The primary outcome is cigarette smoking in the past week at 6 months follow-up. Smoking behaviour (smoking onset, quitting) and effects on the different genders are studied as secondary outcomes. Analysis is by intention to treat. ETHICS AND DISSEMINATION: Ethical approval is obtained from the ethics committee of the University of Itauna in Brazil. Results will be disseminated at conferences, in peer-reviewed journals, throughout the Education Against Tobacco network social media channels and on our websites. TRIAL REGISTRATION NUMBER: NCT03178227.