Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int Heart J ; 65(1): 146-151, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38296568

RESUMO

A 36-year-old woman suffered from an embolic stroke of an undetermined source documented by magnetic resonance imaging with residual right arm weakness. She underwent percutaneous patent foramen ovale (PFO) closure with an 18/25 mm device in another center. One year later, the patient suffered from a transient ischemic attack with dysarthria. She asked for a second opinion at our institution and a contrast-transthoracic (cTTE) /transesophageal echocardiography showed a large residual right-to-left shunt (RLS) through a still patent tunnel after PFO closure. Written informed consent for a redo procedure was obtained from the patient. A catheter-based closure of the residual shunt was therefore planned under local anesthesia and rotational intracardiac echo monitoring. A second equally sized disc (18/18 mm) device was successfully implanted without complications. The patient was discharged home the following day in good clinical condition. Dual antiplatelet therapy was recommended for the first 2 months and then single antiplatelet therapy up to 6 months. At the 6-month follow-up, the cTTE color Doppler showed the stable position of the two nitinol double-disc devices and the c-transcranial Doppler confirmed the abolition of the residual RLS.


Assuntos
Forame Oval Patente , Ataque Isquêmico Transitório , AVC Isquêmico , Adulto , Feminino , Humanos , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Forame Oval Patente/cirurgia , Ataque Isquêmico Transitório/epidemiologia , AVC Isquêmico/epidemiologia , Resultado do Tratamento
2.
Eur Heart J ; 42(16): 1545-1553, 2021 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-33507260

RESUMO

Patent foramen ovale (PFO) is implicated in the pathogenesis of a number of medical conditions but to date only one official position paper related to left circulation thromboembolism has been published. This interdisciplinary paper, prepared with the involvement of eight European scientific societies, reviews the available evidence and proposes a rationale for decision making for other PFO-related clinical conditions. In order to guarantee a strict evidence-based process, we used a modified grading of recommendations, assessment, development, and evaluation (GRADE) methodology. A critical qualitative and quantitative evaluation of diagnostic and therapeutic procedures was performed, including assessment of the risk/benefit ratio. The level of evidence and the strength of the position statements were weighed and graded according to predefined scales. Despite being based on limited and observational or low-certainty randomised data, a number of position statements were made to frame PFO management in different clinical settings, along with suggestions for new research avenues. This interdisciplinary position paper, recognising the low or very low certainty of existing evidence, provides the first approach to several PFO-related clinical scenarios beyond left circulation thromboembolism and strongly stresses the need for fresh high-quality evidence on these topics.


Assuntos
Doença da Descompressão , Forame Oval Patente , Transtornos de Enxaqueca , Tromboembolia , Doença da Descompressão/terapia , Forame Oval Patente/complicações , Forame Oval Patente/terapia , Humanos , Síndrome , Tromboembolia/etiologia , Tromboembolia/prevenção & controle
3.
Int Heart J ; 62(6): 1403-1410, 2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34789644

RESUMO

Significant paravalvular leak regurgitation (PVLR) after transcatheter aortic valve replacement (TAVR) is a well-known complication associated with disabling symptoms related to heart failure and hemolysis or both, with poor prognostic implications. Although challenging and technically demanding, percutaneous closure is an effective treatment option for high-risk patients with symptomatic PVLR. Here, we present two cases of transcatheter PVLR closure after replacement of third-generation (one self-expandable and one balloon-expandable) transcatheter aortic valves, each with peculiar challenges, and the strategies adopted to increase the success rate of percutaneous closure.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/instrumentação , Angioplastia com Balão/métodos , Insuficiência da Valva Aórtica/etiologia , Cateterismo Cardíaco/instrumentação , Feminino , Humanos , Masculino
4.
Catheter Cardiovasc Interv ; 95(4): 855-858, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31713974

RESUMO

We report a case of antegrade transcatheter occlusion of a paravalvular leak (PVL) after bioprosthetic pulmonary valve replacement in a 31-year-old patient with tetralogy of Fallot. The leak resulted in severe pulmonary regurgitation with right ventricle volume overload. This case is the first-ever report of a successful percutaneous closure of PVL using the Occlutech paravalvular leak device.


Assuntos
Bioprótese , Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Insuficiência da Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Adulto , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Desenho de Prótese , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Recidiva , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia , Resultado do Tratamento
5.
Eur Heart J ; 40(38): 3182-3195, 2019 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-30358849

RESUMO

The presence of a patent foramen ovale (PFO) is implicated in the pathogenesis of a number of medical conditions; however, the subject remains controversial and no official statements have been published. This interdisciplinary paper, prepared with involvement of eight European scientific societies, aims to review the available trial evidence and to define the principles needed to guide decision making in patients with PFO. In order to guarantee a strict process, position statements were developed with the use of a modified grading of recommendations assessment, development, and evaluation (GRADE) methodology. A critical qualitative and quantitative evaluation of diagnostic and therapeutic procedures was performed, including assessment of the risk/benefit ratio. The level of evidence and the strength of the position statements of particular management options were weighed and graded according to predefined scales. Despite being based often on limited and non-randomised data, while waiting for more conclusive evidence, it was possible to conclude on a number of position statements regarding a rational general approach to PFO management and to specific considerations regarding left circulation thromboembolism. For some therapeutic aspects, it was possible to express stricter position statements based on randomised trials. This position paper provides the first largely shared, interdisciplinary approach for a rational PFO management based on the best available evidence.


Assuntos
Forame Oval Patente , Tromboembolia , Consenso , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico , Forame Oval Patente/fisiopatologia , Forame Oval Patente/cirurgia , Humanos , Isquemia , Guias de Prática Clínica como Assunto , Medição de Risco , Tromboembolia/complicações , Tromboembolia/diagnóstico , Tromboembolia/terapia , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 88(4): 571-581, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27029396

RESUMO

BACKGROUND: The Occlutech Figulla ASD device series (OFSO) shows an improved device design for interventional ASD closure, larger follow-up series are missing. METHODS: We retrospectively reviewed the feasibility, safety, implantation properties, results, and follow-up of ASD closure using Occlutech devices over a 5 year period by establishing a multi-institutional collaborative result registry with 16 contributing centers from 11 countries (IRFACODE). RESULTS: In 1315 patients of all age groups (female 66.9%), successful (98%) ASD closure was performed (mean age 28.9 years, weight 52 kg, height 148.6 cm). Of the defects, 47.9% showed no or only a deficient aortic rim; in 11.9%, there was more than one defect; a septum aneurysm was present in 21.5%; and the mean implanted device size was 20.5 mm. Immediate closure was achieved in 78.6%, at discharge in 83.1%, and 96.4% and 97.3% at 6 and 12 months follow-up, respectively. During a mean follow-up of 2.7 years (in total 3597 patient years), significant complications were minimal (total = 8, <1%) with secondary device embolizations in five and AV-blocks in three patients. No erosion or death was reported. CONCLUSION: ASD closure using OFSO is feasible in a large variety of patients, safe with only a minimal risk of severe side effects and especially without any aortic erosions despite a large percentage of large and complicated defects. © 2016 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Dispositivo para Oclusão Septal , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ásia , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Europa (Continente) , Estudos de Viabilidade , Feminino , Comunicação Interatrial/diagnóstico por imagem , Humanos , Lactente , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
7.
Front Cardiovasc Med ; 11: 1367515, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39015678

RESUMO

Background: Even though the optimal management of a moderate or large residual shunt following patent foramen ovale (PFO) closure is open to question, recent data confirmed that it is associated with an increased risk of stroke recurrence. Case summary: A 48-year-old woman, a migraineur with visual aura, was diagnosed with a PFO associated with a huge multifenestrated atrial septal aneurysm (mfASA) and a moderate right-to-left shunt, detectable only after a Valsalva maneuver on contrast-transthoracic echocardiography. Brain magnetic resonance imaging showed a 1-mm silent white matter lesion in the right frontal lobe. Although the indication was not supported by guidelines, a transcatheter PFO closure was performed at another center with implantation of a large, equally sized, double-disc device (Figulla UNI 33/33 mm). At 6-month follow-up, a 2D/3D transesophageal echocardiography (TEE) color Doppler showed incorrect orientation of the device, which was not parallel to the interatrial septum, with two discs failing to capture the aortic muscular rim and partially protruding in the right atrium; furthermore, a 4 mm × 7 mm ASA fenestration was documented with a residual bidirectional shunt. Thereafter, the same team performed a minimally invasive cardiac surgery under femoro-femoral cardiopulmonary bypass; however, the procedure proved ineffective and was complicated by postoperative pericarditis with pericardial effusion, requiring further rehospitalization 1 month later due to persistent pericarditis, bilateral pleuritis, phrenic nerve palsy, and atrial flutter, which was treated with amiodarone. The patient asked for a second opinion, and our multidisciplinary heart team decided to offer a percutaneous redo intervention. An uneventful implantation of a regular PFO occluder (Figulla Flex II 16/18 mm) across the septal defect was performed successfully. Twelve-month follow-up with 2D TTE color Doppler and contrast transcranial Doppler showed correct position and good interaction between the two devices, with no residual shunt. Discussion: In addition to the incorrect indication for PFO closure and the failure of minimally invasive surgery, the procedural mishap in this case could have been due to the inappropriate implantation of the first large device within the tunnel. It would have been better to deploy the same large device in the most central fenestration, covering the PFO and a greater part of the remaining mfASA at the same time.

8.
Front Cardiovasc Med ; 11: 1359711, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38450376

RESUMO

Background: Closure of paravalvular leak (PVL) regurgitation after self-expandable (SE) transcatheter aortic valve implantation (TAVI) may be more challenging than after balloon-expandable (BE) valve implantation. Case summary: An 85-year-old woman suffering from long-standing atrial fibrillation and severe symptomatic aortic stenosis underwent SE TAVI (26 mm Evolut™ R®, Medtronic Inc., MN, USA). A total of eighteen months after TAVI she was admitted for congestive heart failure and two-dimensional (2D) transesophageal echocardiography (TEE) color Doppler showed moderate-severe PVL regurgitation due to a long and heavily calcified leak located below the left coronary sinus. The patient was deemed to be at prohibitive surgical risk and a catheter-based PVL closure procedure was planned. A first attempt to cross the PVL from the femoral artery was unsuccessful due to an inappropriate angle between the catheter and the entry site of this hard-to-approach calcified leak. A Terumo hydrophilic guidewire 0.35 inch-260 cm from the right radial artery was then successfully advanced across the leak to the left ventricle (LV); however, of most of the catheters used, only a Glidecath 4-Fr could cross the leak over the hydrophilic wire. The hydrophilic guidewire was replaced with a stiffer guidewire that, after creating a loop in the LV, was advanced across the self-expandable valve into the descending aorta where it was snared and externalized through the left femoral artery, thus creating an arterio-arterial (AA) loop. A 6-Fr Multipurpose guiding catheter was advanced over the exchange wire and the leak was crossed with an additional 0.0014 coronary guidewire (PILOT, Abbott Vascular), predilated with two non-compliant balloon dilatation catheters, and finally, the PVL was engaged with a 3.0 mm × 12 mm Shockwave balloon (Shockwave Medical Inc, Santa Clara, California, USA). Intravascular lithotripsy (IVL) application to this highly calcified leak and the increased support provided by the stiff guidewire finally allowed the progression of the 6-Fr dedicated delivery sheath (ODS III) into the LV. A 5 mm square twist (ST) device (PLD, Occlutech, Helsingborg, Sweden) was successfully deployed within the leak and the final echocardiographic and angiographic control confirmed the effective PVL closure. Discussion: In patients at high surgical risk with moderate to severe regurgitation after SE TAVI due to a hard-to-approach calcified long tract, an extra AA support loop is mandatory during percutaneous PVL closure. Furthermore, IVL application greatly facilitates the progression of the delivery sheath and occluder which is key to a successful procedure.

9.
Catheter Cardiovasc Interv ; 82(1): E38-51, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-22936427

RESUMO

OBJECTIVES: To organize a common approach on the management of patent foramen ovale (PFO) and cryptogenic stroke that may be shared by different specialists. BACKGROUND: The management of PFO related to cryptogenic stroke is controversial, despite an increase in interventional closure procedures. METHODS: A consensus statement was developed by approaching Italian national cardiological, neurological, and hematological scientific societies. Task force members were identified by the president and/or the boards of each relevant scientific society or working group, as appropriate. Drafts were outlined by specific task force working groups. To obtain a widespread consensus, these drafts were merged and distributed to the scientific societies for local evaluation and revision by as many experts as possible. The ensuing final draft, merging all the revisions, was reviewed by the task force and finally approved by scientific societies. RESULTS: Definitions of transient ischemic attack and both symptomatic and asymptomatic cryptogenic strokes were specified. A diagnostic workout was identified for patients with candidate event(s) and patient foramen ovale to define the probable pathogenesis of clinical events and to describe individual PFO characteristics. Further recommendations were provided regarding medical and interventional therapy considering individual risk factors of recurrence. Finally, follow-up evaluation was appraised. CONCLUSIONS: Available data provided the basis for a shared approach to management of cryptogenic ischemic cerebral events and PFO among different Italian scientific societies. Wider international initiatives on the topic are awaited.


Assuntos
Cardiologia/normas , Forame Oval Patente/terapia , Ataque Isquêmico Transitório/terapia , Neurologia/normas , Acidente Vascular Cerebral/terapia , Consenso , Comportamento Cooperativo , Diagnóstico por Imagem/normas , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico , Humanos , Comunicação Interdisciplinar , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/etiologia , Itália , Equipe de Assistência ao Paciente/normas , Valor Preditivo dos Testes , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Terminologia como Assunto , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 82(1): 122-9, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-23788390

RESUMO

OBJECTIVES: To organize a common approach on the management of patent foramen ovale (PFO) and cryptogenic stroke that may be shared by different specialists. BACKGROUND: The management of PFO related to cryptogenic stroke is controversial, despite an increase in interventional closure procedures. METHODS: A consensus statement was developed by approaching Italian national cardiological, neurological, and hematological scientific societies. Task force members were identified by the president and/or the boards of each relevant scientific society or working group, as appropriate. Drafts were outlined by specific task force working groups. To obtain a widespread consensus, these drafts were merged and distributed to the scientific societies for local evaluation and revision by as many experts as possible. The ensuing final draft, merging all the revisions, was reviewed by the task force and finally approved by scientific societies. RESULTS: Definitions of transient ischemic attack and both symptomatic and asymptomatic cryptogenic strokes were specified. A diagnostic workout was identified for patients with candidate event(s) and patient foramen ovale to define the probable pathogenesis of clinical events and to describe individual PFO characteristics. Further recommendations were provided regarding medical and interventional therapy considering individual risk factors of recurrence. Finally, follow-up evaluation was appraised. CONCLUSIONS: Available data provided the basis for a shared approach to management of cryptogenic ischemic cerebral events and PFO among different Italian scientific societies. Wider international initiatives on the topic are awaited.


Assuntos
Cardiologia/normas , Forame Oval Patente/terapia , Ataque Isquêmico Transitório/terapia , Neurologia/normas , Acidente Vascular Cerebral/terapia , Consenso , Comportamento Cooperativo , Diagnóstico por Imagem/normas , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico , Humanos , Comunicação Interdisciplinar , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/etiologia , Itália , Equipe de Assistência ao Paciente/normas , Valor Preditivo dos Testes , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Terminologia como Assunto , Resultado do Tratamento
11.
J Stroke Cerebrovasc Dis ; 22(7): e219-26, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23352683

RESUMO

BACKGROUND: Percutaneous patent foramen ovale (PFO) closure is accepted as treatment for cryptogenic ischemic stroke/transient ischemic attack in young subjects. However, a thorough evaluation of residual right-to-left shunt (rRLS) after PFO closure is needed. Our aims were to analyze the characteristics related to PFO diagnosis and closure, focusing on rRLS and clinical recurrences until 24-month follow-up. Data were extrapolated from the 12-month Italian PFO Survey. METHODS: In all, 1035 patients were included. PFO diagnosis and right-to-left shunt (RLS) were assessed by contrast-enhanced transesophageal and/or transthoracic echocardiography and/or transcranial Doppler. RESULTS: PFO diagnosis with RLS data were available in 894 of 1035 (86.4%) patients. rRLS was investigated in 49.6% (6 months), 27.1% (12 months), and 3.5% (24 months), and observed in 19.5% (6 months) and 18.2% (12 months) of subjects. Large permanent rRLS was observed in less than 3% of RLS-positive patients after 1 year. Eleven of 14 and 3 of 14 neurological recurrences were observed in 10 of 444 (2.25%) and 2 of 243 (0.8%) patients within the 6- and 12-month follow-up, respectively. Among these, no large rRLS was reported. There were no neurological events at 2-year follow-up. Forty of 444 subjects had non-neurological complications, mostly cardiac arrhythmias within the sixth month. CONCLUSIONS: PFO closure is a safe procedure. rRLS is not uncommon but large rRLS is rare. Clinical complications, mostly related to cardiac arrhythmias, are not unusual. Evaluation of the data of the whole survey is underway.


Assuntos
Forame Oval Patente/cirurgia , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Seguimentos , Forame Oval Patente/diagnóstico por imagem , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Resultado do Tratamento , Ultrassonografia
12.
Front Cardiovasc Med ; 10: 1095661, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37063961

RESUMO

Background: Percutaneous suture-mediated patent foramen ovale (PFO) closure has recently been used with the aim of avoiding double-disc nitinol device implantation. This novel technique has been carried out successfully in several centers offering PFO closure with an effective closure rate comparable to conventional double-disc devices. Case summary: A 50-year-old man, a pentathlon athlete, suffering from a previous left-sided ischemic stroke, underwent percutaneous closure of a permanent right-to-left shunt via PFO with a large fenestrated septum primum aneurysm at another institution. The NobleStitch® system was successfully implanted using local anesthesia and under angiographic-fluoroscopic monitoring. He was discharged home on aspirin 100 mg daily with a moderate residual shunt on contrast transthoracic echocardiography (cTTE) that persisted unaltered at subsequent controls. After 7 months, unable to resume sporting activity because of physical discomfort and dyspnea on exertion, the patient asked for a second opinion at our Heart and Brain clinic. Two-dimensional (2D) TTE showed septum primum laceration next to a radiopaque polypropylene knot with a moderate bidirectional shunt located at the fenestrated septum primum far from the PFO site. A catheter-based closure of the septal defect was therefore planned under local anesthesia and rotational intracardiac echo monitoring. An equally sized discs 28.5 mm × 28.5 mm Flex II UNI occluder (Occlutech GmbH, Jena, Germany) was successfully implanted across the atrial septal defect without complications. The patient was discharged in good clinical conditions; dual antiplatelet therapy (aspirin 100 mg/daily and clopidogrel 75 mg/daily) was recommended for 2 months and then single antiplatelet therapy (aspirin100 mg/daily) up to 6 months. Abolition of the residual shunt was confirmed at 1- and 6-month follow-up by contrast transcranial Doppler and 2D color Doppler cTTE. Discussion: Closing a PFO with a suture-base system, without leaving a device implant behind, may be a cutting-edge technology and potential alternative to traditional devices. Nevertheless, meticulous selection of the PFO anatomies by 2D TEE is key to a successful closure procedure in order to avoid complications that must be managed again with a second percutaneous procedure or by surgery.

13.
J Clin Med ; 12(18)2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-37762729

RESUMO

INTRODUCTION: The aim of this study was to assess clinical outcomes and quality of life after PFO closure in patients with previous stroke/TIA of undetermined cause and in patients with other complex PFO-associated clinical conditions. METHODS: Between July 2009 and December 2019 at our University Cardiology Department, 118 consecutive patients underwent a thorough diagnostic work-up including standardized history taking, clinical evaluation, full neurological examination, screening for thrombophilia, brain magnetic resonance imaging (MRI), ultrasound-Doppler sonography of supra-aortic vessels and 24 h ECG Holter monitoring. Anatomo-morphological evaluation using 2D transthoracic/transesophageal echocardiography (TTE/TEE) color Doppler and functional assessment using contrast TTE (cTTE) in the apical four-chamber view and contrast transcranial Doppler (cTCD) using power M-mode modality were performed to verify the presence, location and amount of right-to-left shunting via PFO or other extracardiac source. Completed questionnaires based on the Quality-of-Life Short Form-36 (QoL SF-36) and Migraine Disability Assessment (MIDAS) were obtained from the patients before PFO closure and after 12 months. Contrast TTE/TEE and cTCD were performed at dismission, 1, 6 and 12 months and yearly thereafter. Brain MRI was performed at 1-year follow-up in 54 patients. RESULTS: Transcatheter PFO closure was performed in 106 selected symptomatic patients (mean age 41.7 ± 10.7 years, range 16-63, 65% women) with the following conditions: ischemic stroke (n = 23), transient ischemic attack (n = 22), peripheral and coronary embolism (n = 2), MRI lesions without cerebrovascular clinical events (n = 53), platypnea-orthodeoxia (n = 1), decompression sickness (n = 1) and refractory migraine without ischemic cerebral lesions (n = 4). The implanted devices were Occlutech Figulla Flex I/II PFO (n = 99), Occlutech UNI (n = 3), Amplatzer PFO (n = 3) and CeraFlex PFO occluders (n = 1). Procedures were performed under local anesthesia and rotational intracardiac monitoring (Ultra ICE) alone. The devices were correctly implanted in all patients. The mean fluoroscopy time was 15 ± 5 min (range = 10-45 min) and the mean procedural time was 55 ± 20 min (range = 35-90 min). The total occlusion rate at follow-up (mean 50 months, range 3-100) was 98.1%. No recurrent neurological events were observed in the long-term follow-up. CONCLUSIONS: The data collected in this study demonstrate that percutaneous PFO closure is a safe and effective procedure, showing long-term prevention of recurrent cerebrovascular events, significant reduction in migraine symptoms and substantial improvement in quality of life.

14.
EuroIntervention ; 19(5): e442-e449, 2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37128805

RESUMO

BACKGROUND: Data regarding the safety and long-term effectiveness of percutaneous closure of paravalvular leak (PVL) after transcatheter aortic valve implantation (TAVI) are scarce. AIMS: This study aims to present a large multicentre international experience of percutaneous post-TAVI PVL closure. METHODS: All patients who underwent percutaneous post-TAVI PVL closure in 14 hospitals across Europe and North America between January 2018 and October 2022 were included. RESULTS: Overall, 45 patients (64% male) were enrolled. The median age was 80 years (75-84). Among them, 67% and 33% had self-expanding and balloon-expandable valve implantations, respectively. Baseline post-TAVI PVL was severe in 67% of cases and moderate in the rest. The time from index TAVI to PVL closure procedure was 16.1 (8.7-34.8) months. Most patients were in NYHA Class III and IV (73%) before the procedure, and 40% had referred hospitalisations for heart failure between TAVI and the PVL closure procedure. Successful PVL closure was achieved in 94%, reducing regurgitation to ≤mild in 91% and moderate in the rest. The Amplatzer Valvular Plug III was the most frequently used device (27 cases), followed by the Amplatzer Valvular Plug 4. The incidence of severe adverse events was 11%. None of the patients died during the index hospitalisation. During long-term follow-up (21.7±16.2 months), the all-cause mortality rate was 14%, and patients presented improvement in functional status and a significant reduction in the rate of hospitalisation for heart failure (from 40% to 6%). CONCLUSIONS: Percutaneous PVL closure is a feasible and safe option for treating post-TAVI leaks. Successful PVL reduction to mild or less could be associated with acute and long-lasting improvements in clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Sistema de Registros , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia
15.
Front Cardiovasc Med ; 9: 839159, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35833184

RESUMO

Background: Aortic paravalvular leak (APVL) after surgical valve replacement (AVR) is an ominous complication with a high risk of morbidity and mortality. Approximately 1-5% of PVLs can lead to serious clinical consequences, including congestive heart failure and/or hemolytic anemia. Case Summary: A 69-year-old man with multiple comorbidities underwent surgical replacement of the aortic valve with a mechanical tilting disc prosthetic valve (Medtronic Starlight 27 mm). Several years later, recurrent episodes of congestive heart failure and hemolytic anemia developed due to a large crescent-shaped aortic PVL located at non coronary cusp (NCC) 9-12 o'clock, with moderate-to-severe regurgitation. The patient was deemed at prohibitive surgical risk due to significant multiple comorbidities and a transcatheter PVL closure (TPVLc) was planned. The huge PVL was partially closed by a first specifically designed paravalvular leak device (PLD). The procedure was complicated by transient interference of the second PLD with mechanical prosthetic valve function. This issue has however been solved with correct manipulation, orientation and downsizing of the second device implanted. At 3-month and 13-month follow-up, the patient showed a relevant clinical improvement and good quality of life. 2D TTE color Doppler confirmed the stable position of the two PLDs with trace residual leak. Discussion: Surgical redo has been considered the treatment of choice for symptomatic patients with PVLs. Notwithstanding, TPVLc is a less invasive alternative, particularly in patients at high surgical risk in whom early diagnosis and prompt interventional treatment are crucial for improving expectancy and quality of life. Dedicated devices, appropriate procedural techniques, and the close interaction between imaging modalities, allowed to deal successfully with a challenging case of severe symptomatic aortic PVL.

16.
J Clin Med ; 11(11)2022 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-35683375

RESUMO

Moderate to severe paravalvular-leak (PVL) regurgitation after surgical aortic-valve replacement or after transcatheter valve implantation represents a well-known complication associated with symptoms related to heart failure, hemolysis, or both in patients with multiple comorbidities and with poor prognostic outcomes. The transcatheter closure of aortic paravalvular leaks (APVLs) is currently considered a valid alternative to cardiac surgery. Nevertheless, careful patient selection, optimal cardiac imaging for intraprocedural guidance, and expert operators are key for success. Although technically demanding, particularly in APVLs after transcatheter valve implantation, catheter-based closure is an effective, less invasive, and often the only option for high-risk patients with symptomatic PVL regurgitation.

17.
Front Neurol ; 13: 1079959, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36588875

RESUMO

A pulmonary arteriovenous fistula (PAVM) is an abnormal blood vessel that creates a direct connection between a pulmonary artery and its tributary vein bypassing capillary filter, establishing as a consequence of a low-resistance right-to-left shunting (RLS). The vast majority of PAVMs are congenital appearing more often in females than in males. A great number of patients with PAVMs is suffering concurrently from hereditary hemorrhagic telangiectasia (HHT) whose incidence is around 1 in 5,000. Very few cases of acquired PAVMs have been described in the literature. Paradoxical embolism through PAVMs can cause systemic desaturation, cyanosis, and serious cerebrovascular ischemic events (transient ischemic attacks, strokes, and intracranial abscess), even when the abnormal blood vessel is small (diameter <3 mm). Notably, it has been reported a high prevalence of aura migraine (MHA) symptoms in patients with PAVMs and concomitant HHT. We described in this study the case of a young aura migraineur female patient without HHT in whom isolated PAVM below the detection limit of pulmonary angiography and chest computed tomography angiography (CTA) has been documented by contrast Transthoracic and Transesophageal Echocardiography (cTTE/TEE) showing a delayed (>17 s) RLS coming from left pulmonary veins to left atrium while a patent foramen ovale (PFO), small atrial septal defects or septum primum fenestration could not be detected despite several attempts. Contrast Transcranial Doppler (cTCD) confirmed a delayed (>16 s) RLS with two short "shower" patterns corroborating the diagnosis of an extra-cardiac RLS. During the right heart catheterization and pulmonary angiography, it was impossible to cross the interatrial septum with a multipurpose catheter. The patient was finally discharged with off-label thienopyridine agents (clopidogrel 75 mg die) in terms of primary prophylaxis for paradoxical right-to-left embolization of thrombotic material ultimately. Aura migraine symptoms were nearly abolished by P2Y12 platelet inhibition, suggesting a platelet-based mechanism. During 2 years of clinical follow-up on thienopyridine therapy, the resolution of aura migraine episodes was definitively accomplished with significant improvement in her quality of life.

18.
J Clin Med ; 11(5)2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35268418

RESUMO

Widespread catheter-based interventions for structural heart disease have overtaken the treatment of paravalvular leaks (PVL). Multimodality imaging techniques play a crucial role in accurate diagnosis, procedure planning and performance. However, PVL closure is often technically challenging due to the complex anatomy of the defects and their relation to surrounding anatomical structures. The application of echocardiography and fluoroscopy imaging fusion (EFF) may simplify challenging imaginative three-dimensional reconstruction of the intracardiac anatomy and facilitate the procedure. To master new technology, personnel must make cognitive changes, overcome a learning curve, and obtain adequate theoretical knowledge. Main aim of this manuscript is to present basic recommendations for EFF application in practice, alongside, each scenario is supported by technically challenging clinical examples. We may conclude that our manuscript may provide useful information for physicians on EEF application in clinical practice.

19.
J Clin Med ; 11(17)2022 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-36078929

RESUMO

BACKGROUND: There is a lack of studies where the outcomes of mitral paravalvular leak treatment were compared between surgery and catheter-based closure. The aim of this study was to compare the outcomes of re-do surgery with transapical catheter-based paravalvular leak closure. METHODS: This is a retrospective observational study at a single institution; 76 patients were included. According to the treatment, two groups were formed: the "Surgical" group (49 patients after re-do surgery) and the "Catheter" group (27 patients after transapical catheter-based treatment). RESULTS: In-hospital myocardial infarction occurred in 9 (18%) cases in the "Surgical" group and none in the "Catheter" group, p = 0.018. Procedure-related life-threatening bleeding occurred in 9 (18%) patients in the "Surgical" group and none in the "Catheter" group, p = 0.018. Nine (18%) patients died in 30 days in the "Surgical" group, and none died in the "Catheter" group, p = 0.039. A mean follow-up was 3.3 years. No difference was found between the groups by the degree of residual paravalvular regurgitation either at discharge or at follow-up. During the follow-up, 19 (39%) patients died in the "Surgical" group and 2 (7%) among the "Catheter" patients. CONCLUSIONS: Transapical catheter-based closure of mitral paravalvular leak seems to be a safer treatment procedure than conventional re-do surgery, and the effectiveness of these procedures does not differ.

20.
J Clin Med ; 12(1)2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36614920

RESUMO

Prosthetic paravalvular leaks (PVLs) are associated with congestive heart failure and hemolysis. Surgical PVL closure carries high risks. Transcatheter implantation of occluding devices in PVL is a lower risk but challenging procedure. Of the available devices, only two have been specifically approved in Europe for transcatheter PVL closure (tPVLc): the Occlutech® Paravalvular Leak Device (PLD) and Amplatzer™ ParaValvular Plug 3 (AVP 3). Here, we review the various tools and devices used for tPVLc, based on three observational registries including 748 tPVLc procedures performed in 2005-2021 at 33 centres in 11 countries. In this case, 12 registry investigators with over 20 tPVLc procedures each described their practical tips and tricks regarding imaging, approaches, delivery systems, and devices. They considered three-dimensional echocardiography to be the cornerstone of PVL assessment and procedure guidance. Anterograde trans-septal mitral valve and retrograde aortic approaches were used in most centres, although some investigators preferred the transapical approach. Hydrophilic-coated low-profile sheaths were used most often for device deployment. The AVP 3 and PLD devices were chosen for 89.0% of procedures. Further advances in design and materials are awaited. These complex procedures require considerable expertise, and experience accumulated over a decade has no doubt contributed to improve practices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA