RESUMO
AIMS: After primary radiotherapy, biochemical recurrence is defined according to the Phoenix criteria as a prostate-specific antigen (PSA) value >2 ng/ml relative to the nadir. Several studies have shown that prostate-specific membrane antigen (PSMA)-ligand positron emission tomography/computed tomography (PET/CT) can help in detecting recurrence in patients with low PSA values. This study aimed to assess the detection rate and patterns of PSMA-ligand PET/CT uptake in patients with suspected biochemical recurrence after primary radiotherapy and with PSA levels below the Phoenix threshold. MATERIALS AND METHODS: The meta-analysis was carried out in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Articles providing data on patients with suspected prostate cancer recurrence after primary radiotherapy with a PSA value below the Phoenix threshold and who underwent PSMA-ligand PET/CT were included. Quality assessment was carried out using the Quality Assessment of Diagnostic Accuracy Studies-2 tool (QUADAS-2). RESULTS: In total, five studies were included, recruiting 909 patients (202 with PSA ≤2 ng/ml). The PSMA-ligand detection rate in the patients with ≤2 ng/ml ranged from 66 to 83%. The most frequent source of PSMA-ligand PET/CT uptake was local recurrence, followed by lymph node metastasis and bone metastasis. PSMA-ligand PET/CT uptake due to local-only recurrence was more likely in patients with PSA ≤2 ng/ml compared with PSA > 2 ng/ml: risk ratio 0.72 (95% confidence interval 0.58-0.89), P = 0.003. No significant differences were observed in the detection of PSMA-ligand uptake in other areas. Limitations include a lack of biopsy confirmation, cohort reports with small sample sizes and a potentially high risk of bias. CONCLUSION: A significant detection of PSMA-ligand-avid disease was observed in patients with PSA levels below the Phoenix threshold. There was a higher likelihood of detecting local-only uptake when the PSA value was ≤2 ng/ml. The findings suggest that a critical review of the Phoenix criteria may be warranted in the era of PSMA-ligand PET/CT and highlight the need for further prospective trials.
Assuntos
Antígeno Prostático Específico , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Próstata/patologia , Ligantes , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Estudos RetrospectivosRESUMO
OBJECTIVES: To validate and analyse the clinical usefulness of a predictive model of prostate cancer that incorporates the biomarker «[-2] pro prostate-specific antigen¼ using the prostate health index (PHI) in decision making for performing prostate biopsies. MATERIAL AND METHODS: We isolated serum from 197 men with an indication for prostate biopsy to determine the total prostate-specific antigen (tPSA), the free PSA fraction (fPSA) and the [-2] proPSA (p2PSA). The PHI was calculated as p2PSA/fPSA×âtPSA. We created 2 predictive models that incorporated clinical variables along with tPSA or PHI. The performance of PHI was assessed with a discriminant analysis using receiver operating characteristic curves, internal calibration and decision curves. RESULTS: The areas under the curve for the tPSA and PHI models were 0.71 and 0.85, respectively. The PHI model showed a better ability to discriminate and better calibration for predicting prostate cancer but not for predicting a Gleason score in the biopsy ≥7. The decision curves showed a greater net benefit with the PHI model for diagnosing prostate cancer when the probability threshold was 15-35% and greater savings (20%) in the number of biopsies. CONCLUSIONS: The incorporation of p2PSA through PHI in predictive models of prostate cancer improves the accuracy of the risk stratification and helps in the decision-making process for performing prostate biopsies.