1.
Diabetes Technol Ther ; 26(4): 238-245, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38156961

RESUMO

Background: Heating of the arm and/or hand ("arterialization") is sometimes used in continuous glucose monitoring (CGM) performance studies with the reported aim of reducing differences between venous and capillary glucose concentrations. In this study, the effect of heating on venous glucose concentrations and CGM accuracy was investigated. Methods: A heating pad set to 50°C (122°F) was used with 20 participants to heat either the dominant or nondominant arm and hand. Venous and capillary samples were obtained every 15 min on both arms throughout each of three 6-h glucose challenges. CGM sensors were worn on each upper arm for each of the three visits. Results: Heating of the arm led to a median increase in venous glucose concentrations of +1.4%. No similar effect on capillary concentrations was observed. As a result, the median capillary to venous difference decreased from +5.9% in the nonheated arm to +4.2% in the heated arm. CGM accuracy observed in this study was affected by the selection of heated venous, nonheated venous, or capillary glucose concentrations as comparator data. The heating effect was more pronounced with rapidly decreasing glucose concentrations. Temperatures on the skin did not exceed 40°C (104°F). No adverse events or protocol deviations were associated with the use of the heating pad. Conclusions: Heating of the arm led to a small increase in venous glucose concentrations, but venous concentrations did not reach the level of capillary glucose concentrations. CGM accuracy observed in this study varied depending on the selected comparator data. This study was registered at the German Clinical Trials Register (DRKS00031197).


Assuntos
Automonitorização da Glicemia , Glicemia , Humanos , Automonitorização da Glicemia/métodos , Monitoramento Contínuo da Glicose , Veias , Pele
2.
J Diabetes Sci Technol ; : 19322968241267765, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39158983

RESUMO

BACKGROUND: Nocturnal hypoglycaemia is a burden for people with diabetes, particularly when treated with multiple daily injections (MDI) therapy. However, the characteristics of nocturnal hypoglycaemic events in this patient group are only poorly described in the literature. METHOD: Continuous glucose monitoring (CGM) data from 185 study participants with type 1 diabetes using MDI therapy were collected under everyday conditions for up to 13 weeks. Hypoglycaemic events were identified as episodes of consecutive CGM readings <70 mg/dl or <54 mg/dl for at least 15 minutes. Subsequently, the time <54 mg/dl (TB54), time below range (TBR), time in range (TIR), time above range (TAR), glucose coefficient of variation (CV), and incidence of hypoglycaemic events were calculated for diurnal and nocturnal periods. Furthermore, the effect of nocturnal hypoglycaemic events on glucose levels the following day was assessed. RESULTS: The incidence of hypoglycaemic events <70 mg/dl was significantly lower during the night compared to the day, with 0.8 and 3.8 events per week, respectively, while the TBR, TB54, and incidence of events with CGM readings <54 mg/dl was not significantly different. Nocturnal hypoglycaemic events <70 mg/dl were significantly longer (60 vs 35 minutes) and enveloped by less rapidly changing glucose levels. On days following nights containing hypoglycaemic events, there was a decrease in TAR, mean CGM glucose level and morning glucose levels and an increase in TB54, TBR, and CV. CONCLUSIONS: The results showed that nocturnal hypoglycaemic events are a common occurrence in persons with type 1 diabetes using MDI with significant differences between the characteristics of nocturnal and diurnal events.