Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Retina ; 42(8): 1433-1441, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35333841

RESUMO

PURPOSE: To evaluate the degenerative findings including cistern formation in the premacular vitreous using optical coherence tomography. METHODS: A novel enhanced vitreous imaging method by which four A-scans at each position were averaged before the Fourier transform increased the image quality per frame so that subsequent image registration for averaging could occur. Analysis of B-scans and volume-rendered images of eyes in subjects of various ages was performed. RESULTS: There were 43 eyes of 23 subjects ranging in age from 23 to 68 years. The texture in the vitreous images suggests specific orientations of the vitreous fibers in the macular region; there were fibers circumferential to the retina immediately anterior to the premacular bursa. The pattern of the vitreous fibers seemed less well-defined internal to the zone of circumferential fibers. In younger eyes, there were striations oriented in a roughly inferior to superior direction in this zone. In older eyes, there were striations in the same orientation but actually were alternating zones of vitreous synchysis and syneresis. In these same eyes, numerous cisterns appeared at various levels in the vitreous gel. With extensive vitreous condensation and synchysis, definition of the premacular bursa was lost. CONCLUSION: With this novel method of enhanced vitreous imaging, the vitreous seemed to have stereotypic patterns of degeneration. The formation of vitreous syneresis and synchysis may be related to organization architecture of the vitreous, including the pattern of vitreous collagen deposition, and the effects of eye motion through decades of time.


Assuntos
Tomografia de Coerência Óptica , Corpo Vítreo , Adulto , Idoso , Voluntários Saudáveis , Humanos , Pessoa de Meia-Idade , Retina , Tomografia de Coerência Óptica/métodos , Corpo Vítreo/diagnóstico por imagem , Adulto Jovem
2.
Retina ; 41(6): 1314-1317, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34001833

RESUMO

PURPOSE: To describe imaging produced by machine learning-based segmentation of high-resolution optical coherence tomography imaging of the intermediate capillary plexus and deep capillary plexus, layers of vessels not imaged well by dye-based angiography. METHODS: Three healthy subjects with no ocular problems were imaged with spectral domain optical coherence tomography using an instrument with a scanning speed of 85,000 A-scans per second and 3 µm axial optical resolution. A random forest segmentation strategy was used to segment the intermediate capillary plexus and deep capillary plexus. The depth-resolved imaging data was visualized with the help of volume rendering. RESULTS: The high-resolution optical coherence tomography showed the intermediate capillary plexus and deep capillary plexus at the outer borders of the inner nuclear layer. These vessels could be visualized with unprecedented detail in three dimensions. There were multiple bridging vessels connecting to the whorl-like patterns of capillary mesh of the deep capillary plexus, a feature only previously imaged in histologic evaluation of excised eyes. CONCLUSION: High-resolution optical coherence tomography, machine learning, and advanced image display techniques have wide relevancy in studying the retina in health and disease. Application of this approach has provided images of the deeper vascular layers of the eye that approximate histologic imaging, but noninvasively.


Assuntos
Capilares/diagnóstico por imagem , Aprendizado de Máquina , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Voluntários Saudáveis , Humanos
3.
Ophthalmic Res ; 63(2): 77-87, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31352462

RESUMO

Novel diagnostic tools to measure retinal function and structure are rapidly being developed and introduced into clinical use. Opportunities exist to use these informative and robust measures as endpoints for clinical trials to determine efficacy and to monitor safety of therapeutic interventions. In order to inform researchers and clinician-scientists about these new diagnostic tools, a workshop was organized by the European Vision Institute. Invited speakers highlighted the recent advances in state-of-the-art technologies for outcome measures in the field of retina. This review highlights the workshop's presentations in the context of published literature.


Assuntos
Academias e Institutos , Grupos Focais , Avaliação de Resultados em Cuidados de Saúde , Retina/diagnóstico por imagem , Doenças Retinianas/diagnóstico , Tomografia de Coerência Óptica/métodos , Europa (Continente) , Humanos
4.
Ophthalmic Res ; 63(2): 88-96, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31935739

RESUMO

Glaucoma is the leading cause of irreversible blindness worldwide, with an increasing prevalence. The complexity of the disease has been a major challenge in moving the field forward with regard to both pathophysiological insight and treatment. In this context, discussing possible outcome measures in glaucoma trials is of utmost importance and clinical relevance. A recent meeting of the European Vision Institute (EVI) special interest focus group was held on "New Technologies for Outcome Measures in Retina and Glaucoma," addressing both functional and structural outcomes, as well as translational hot topics in glaucoma and retina research. In conjunction with the published literature, this review summarizes the meeting focusing on glaucoma.


Assuntos
Academias e Institutos , Grupos Focais , Glaucoma/fisiopatologia , Nervo Óptico/fisiopatologia , Avaliação de Resultados em Cuidados de Saúde , Visão Ocular/fisiologia , Europa (Continente) , Humanos , Nervo Óptico/patologia , Células Ganglionares da Retina/patologia
5.
Invest Ophthalmol Vis Sci ; 65(6): 9, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38837167

RESUMO

Purpose: Optical coherence tomography (OCT) representations in clinical practice are static and do not allow for a dynamic visualization and quantification of blood flow. This study aims to present a method to analyze retinal blood flow dynamics using time-resolved structural OCT. Methods: We developed novel imaging protocols to acquire video-rate time-resolved OCT B-scans (1024 × 496 pixels, 10 degrees field of view) at four different sensor integration times (integration time of 44.8 µs at a nominal A-scan rate of 20 kHz, 22.4 µs at 40 kHz, 11.2 µs at 85 kHz, and 7.24 µs at 125 kHz). The vessel centers were manually annotated for each B-scan and surrounding subvolumes were extracted. We used a velocity model based on signal-to-noise ratio (SNR) drops due to fringe washout to calculate blood flow velocity profiles in vessels within five optic disc diameters of the optic disc rim. Results: Time-resolved dynamic structural OCT revealed pulsatile SNR changes in the analyzed vessels and allowed the calculation of potential blood flow velocities at all integration times. Fringe washout was stronger in acquisitions with longer integration times; however, the ratio of the average SNR to the peak SNR inside the vessel was similar across all integration times. Conclusions: We demonstrated the feasibility of estimating blood flow profiles based on fringe washout analysis, showing pulsatile dynamics in vessels close to the optic nerve head using structural OCT. Time-resolved dynamic OCT has the potential to uncover valuable blood flow information in clinical settings.


Assuntos
Fluxo Sanguíneo Regional , Vasos Retinianos , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Humanos , Vasos Retinianos/fisiologia , Vasos Retinianos/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Disco Óptico/irrigação sanguínea , Disco Óptico/diagnóstico por imagem , Razão Sinal-Ruído , Masculino , Feminino , Adulto , Pessoa de Meia-Idade
6.
Transl Vis Sci Technol ; 11(1): 28, 2022 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-35044444

RESUMO

Purpose: The lateral resolution of an optical coherence tomography (OCT) instrument was considered to be equal to the illumination spot size on the retina. To evaluate the potential lateral resolution of the Spectralis OCT, an instrument calculated to have a 14 µm resolution. Methods: The lateral point spread function (PSF) was evaluated using diamond abrasive powder 0 to 1 µm in diameter in silicone elastomer and a validated target with 800 nm FeO particles in urethane. The amplitude transfer function was calculated from human OCT images. Finally, resolution was measured using the 1951 USAF target. Results: Measurement of the lateral PSF from 1215 diamond particle images yielded a full-width half maximum (FWHM) to be 5.11 µm and for 732 FeO particles, 4.9 µm. From the amplitude transfer function, the FWHM of the diffraction limited PSF was calculated to be 5.0 µm. The USAF target imaging showed a lateral resolution of 4.6 µm. Conclusions: Although a calculation of the spot size of the illumination beam was reported in the past as the lateral resolution of the OCT instrument, the actual lateral resolution is better by a factor of at least 2.5 times. The clinically used A-scan spacing was derived from the calculated, and not the true resolution, and results in under sampling. This set of findings likely apply to all commercial clinical instruments. Translational Relevance: The scan density parameters of past and present commercial OCT instruments were based on earlier translational concepts, which now appear to have been incorrect.


Assuntos
Retina , Tomografia de Coerência Óptica , Humanos
SELEÇÃO DE REFERÊNCIAS