Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Echogr ; 34(2): 85-89, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39086698

RESUMO

Aortic intramural hematoma (IMH) accounts for approximately 10%-25% of acute aortic syndromes (AAS), and multi-slice computed tomography and magnetic resonance imaging are the leading techniques for diagnosis and classification. In this context, endovascular strategies provide a valid alternative to traditional open surgery and transesophageal echocardiography (TEE) could play a role in therapeutic decision-making and in endovascular repair procedure guidance. A 57-year-old female patient with IMH extending from the left subclavian artery to the upper tract of the abdominal aorta, underwent endovascular aortic repair using an unibody single-branched stent grafting in the aortic arch and descending aorta with a side branch inserted in the left common carotid artery. To restore proper flow in the left axillary artery, a carotid-subclavian bypass graft was performed. The procedure was guided by angiography and TEE. Intraoperative TEE revealed aortic IMH with a significant fluid component in the middle tunic of the aorta with a wall thickness of over 13 mm. TEE was useful in monitoring of all steps of the procedure, showing the presence of the guidewires into the true lumen, the advancement of the prosthesis, and the phases of release and anchoring. This case highlights the importance of using multimodality imaging techniques to evaluate AAS and demonstrates the growing potential of TEE in guiding endovascular repairs.

2.
Curr Probl Cardiol ; 49(5): 102491, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38428553

RESUMO

An 84-year-old man with extensive calcified atherosclerosis of the infrarenal abdominal aorta was diagnosed with severe aortic valve stenosis, presenting with dyspnea. To facilitate transfemoral approach during the TAVI procedure, IVUS-guided intravascular lithotripsy was successfully performed using Kissing Shockwave Balloon Technique.


Assuntos
Aorta Abdominal , Estenose da Valva Aórtica , Masculino , Humanos , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico
3.
Front Cardiovasc Med ; 11: 1309840, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38510196

RESUMO

Penetrating aortic ulcer (PAU) represents a subset of acute aortic syndromes characterized by high rupture risk and management challenges, particularly in elderly patients with significant comorbidities. This case report showcases a 75-year-old patient with a history of coronary artery bypass graft (CABG) and with multiple PAUs involving the aortic arch, deemed unfit for conventional open surgery. A branched aortic endograft with a pre-cannulated side component for the left subclavian artery (LSA) was employed to preserve the patency of the previous CABG. Two computational fluid dynamics (CFD) simulations and a morphological analysis were performed on the pre- and post-intervention aortic configurations to evaluate changes in flow rate and pressure drop at LSA level and differences in the lumen size. The results revealed a decrease in the flow rate equal to 2.38% after the intervention and an increase in pressure drop of 4.48 mmHg, while the maximum differences in LSA cross-sectional areas and diameters were 1.49 cm2 and 0.64 cm, respectively. Minimal alteration in LSA blood flow due to the chosen intervention approach confirmed the effectiveness of the selected unibody design endograft with LSA preservation, ensuring myocardial perfusion. Therefore, CFD simulations demonstrate to be a powerful tool to evaluate the hemodynamic consequences of interventions by accurately estimating the main fluid dynamic parameters.

4.
Curr Probl Cardiol ; 49(9): 102689, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38844267

RESUMO

INTRODUCTION: Since 2019, Braile Biomédica® introduced a novel custom-made abdominal endograft tailored to the aorta's anatomy, featuring sizing every 3 mm and a diameter change from 50 mm to 8 mm. This design permits uncovered fenestrations around a single Z stent, eliminating the need for bridging stents to visceral vessels. Utilizing triple stent technology, optimal neck fixation is ensured, enabling treatment of necks shorter than 2 mm, with three 360° fenestrations optimizing graft fixation. This paper aims to analyze the initial experience with this custom-made infrarenal graft for abdominal aorta aneurysm (AAA), concerning procedural success and post-procedural short-term outcomes. RESULTS: Among 12 patients treated from May 2022 to January 2024, technical success was achieved in 91.7 %, with only one intra-procedural complication. Follow-up CT scans at 1-3 months revealed resolution of an intraoperative endoleak and two late complications: a late type III endoleak and right renal artery occlusion. CONCLUSIONS: The recent experience with Braile Biomédica® custom-made abdominal endograft demonstrates promising outcomes, particularly in treating AAAs with challenging anatomical features.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Desenho de Prótese , Stents , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Implante de Prótese Vascular/métodos , Implante de Prótese Vascular/instrumentação , Itália , Masculino , Feminino , Idoso , Resultado do Tratamento , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Fatores de Tempo , Complicações Pós-Operatórias
5.
Artigo em Inglês | MEDLINE | ID: mdl-38862370

RESUMO

BACKGROUND: Smoker's paradox usually refers to the observation of a favorable outcome of smoking patients in acute myocardial infarction. METHODS: From April 2006 to December 2018 a population of 2456 patients with ST segment elevation myocardial infarction (STEMI) treated with primary percutaneous coronary intervention (pPCI) were prospectively enrolled in the MATRIX registry. Ischemic time, clinical, demographics, angiographic data, and 1-year follow-up were collected. RESULTS: Among 2546 patients admitted with STEMI, 1007 (41 %) were current smokers. Smokers were 10 years younger and had lower crude in-hospital and 1-year mortality (1.5 % vs 6 %, p < 0.0001 and 5 % vs 11 %, p < 0.0001), shorter ischemic time (203 [147-299] vs 220 [154-334] minutes, p = 0.002) and shorter decision time (60 [30-135] vs 70 [36-170] minutes, p = 0.0063). Smoking habit [OR:0.37(95 % CI:0.18-0.75)-p < 0.01], younger age [OR 1.06 (95%CI:1.04-1.09)-p < 0.001] and shorter ischemic time [OR:1.01(95%CI:1.01-1.02)-p < 0.05] were associated to lower in-hospital mortality. Only smoking habit [HR:0.65(95 % CI: 0.44-0.9)-p = 0.03] and younger age [HR:1.08 (95%CI:1.06-1.09)-p < 0.001] were also independently associated to lower all-cause death at 1-year follow-up. After propensity matching, age, cardiogenic shock and TIMI flow <3 were associated with in-hospital mortality, while smoking habit was still associated with reduced mortality. Smoking was also associated with reduced mortality at 1-year follow-up (HR 0.54, 95 % CI [0.37-0.78]; p < 0.001). CONCLUSIONS: Smoking patients show better outcome after PCI for STEMI at 1-year follow-up. Although "Smoking paradox" could be explained by younger age of patients, other factors may have a role in the explanation of the phenomenon.

6.
J Cardiovasc Echogr ; 33(3): 148-152, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38161772

RESUMO

Thoracic endovascular aortic repair (TEVAR) plays a central role in managing acute and chronic aortic pathologies. With the advancement of transcatheter structural heart procedures, echocardiography has become a key in procedural guidance. Despite consensus on its use for cardiac interventions, ultrasound assistance in aortic procedures is not widely standardized. A 71-year-old obese man with chronic type B aortic dissection underwent a TEVAR procedure, using a single-branched aortic stent graft (Endovastec™ Castor™) and with transesophageal ultrasound guidance. The preprocedural assessment confirmed the presence of aortic dissection of the descending thoracic aorta with a posterior true lumen (TL) and an anterior false lumen (FL), normal aortic valve anatomy and function, normal left ventricular function, absence of intracavity thrombus, and absence of aortic plaques that could prevent the optimal implantation of the stent graft. During the procedure, a transesophageal echocardiogram (TEE) monitored the positioning of the guide wires, the arrival of the catheter of the thoracic endoprosthesis, and then the implantation of this at the level of the aortic arch and the descending thoracic aorta. Postprocedure TEE evaluation underlined full stent-graft deployment without leaks and successful exclusion of FL with the beginning of thrombosis. Angiography confirms the exclusion of the aneurysm and the absence of endoleaks. This clinical case demonstrates how transesophageal echocardiographic guidance can improve the TEVAR procedure by minimizing fluoroscopy time, contrast medium use, and enabling a better assessment of the dissection anatomy with real-time monitoring of both the TL and the FL. In conclusion, TEE can serve as an auxiliary intraoperative imaging tool to provide good information before, during, and after the procedure, increasing the success and safety of the TEVAR.

7.
J Clin Med ; 12(24)2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38137662

RESUMO

In the context of thoracic endovascular aortic repair (TEVAR), the reconstruction of the left subclavian artery (LSA) has emerged as a crucial component in establishing a sufficient proximal landing zone. However, the technical difficulty of these procedures raises the possibility of endoleaks and neurological consequences. Single-branched stent grafts offer good anchoring and LSA flow for these patients. This study evaluates the feasibility of utilizing novel single-branched stent grafts in the treatment of distal aortic arch disease, identifying good results in the short and medium term. From September 2019 to March 2023, TEVAR and revascularized LSA were performed on ten patients at the Ospedale del Cuore-FTGM in Massa, Italy, using Castor single-branched thoracic aortic stent grafts (Microport Medical, Shanghai, China). The authors' first findings demonstrated that, after an average follow-up of one year, the Castor branching aortic stent graft system was safe and achieving an appropriate proximal landing zone and maintaining sufficient LSA perfusion was possible. With regard to the endovascular treatment of distal aortic arch diseases, this product offers a compelling substitute for surgery. For the purpose of assessing the long-term effectiveness of this approach, the follow-up period should be extended.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA