Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 32(6): 4046-4055, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35066633

RESUMO

OBJECTIVES: To evaluate the diagnostic value of computer-aided diagnosis (CAD) software on ultrasound in distinguishing benign and malignant breast masses and avoiding unnecessary biopsy. METHODS: This prospective, multicenter study included patients who were scheduled for pathological diagnosis of breast masses between April 2019 and November 2020. Ultrasound images, videos, CAD analysis, and BI-RADS were obtained. The AUC, accuracy, sensitivity, specificity, PPV, and NPV were calculated and compared with radiologists. RESULTS: Overall, 901 breast masses in 901 patients were enrolled in this study. The accuracy, sensitivity, specificity, PPV and NPV of CAD software were 89.6%, 94.2%, 87.0%, 80.4%, and 96.3, respectively, in the long-axis section; 89.0%, 91.4%, 87.7%, 80.8%, and 94.7%, respectively, in the short-axis section. With BI-RADS 4a as the cut-off value, CAD software has a higher AUC (0.906 vs 0.734 vs 0.696, all p < 0.001) than both experienced and less experienced radiologists. With BI-RADS 4b as the cut-off value, CAD software showed better AUC than less experienced radiologists (0.906 vs 0.874, p < 0.001), but not superior to experienced radiologists (0.906 vs 0.883, p = 0.057). After the application of CAD software, the unnecessary biopsy rate of BI-RADS categories 4 and 5 was significantly decreased (33.0% vs 11.9%, 37.8% vs 14.5%), and the malignant rate of biopsy in category 4a was significantly increased (11.6% vs 40.7%, 7.4% vs 34.9%, all p < 0.001). CONCLUSIONS: CAD software on ultrasound can be used as an effective auxiliary diagnostic tool for differential diagnosis of benign and malignant breast masses and reducing unnecessary biopsy. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov (NCT03887598) KEY POINTS: • Prospective multicenter study showed that computer-aided diagnosis software provides greater diagnostic confidence for differentiating benign and malignant breast masses. • Computer-aided diagnosis software can help radiologists reduce unnecessary biopsy. • The management of patients with breast masses becomes more appropriate.


Assuntos
Neoplasias da Mama , Mama , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Computadores , Diagnóstico por Computador/métodos , Feminino , Humanos , Estudos Prospectivos , Sensibilidade e Especificidade , Ultrassonografia Mamária/métodos
2.
Zhongguo Dang Dai Er Ke Za Zhi ; 21(1): 6-10, 2019 Jan.
Artigo em Zh | MEDLINE | ID: mdl-30675856

RESUMO

OBJECTIVE: To investigate the incidence of neonatal asphyxia and possible contributing factors for the development of severe asphyxia in Hubei Enshi Tujia and Miao Autonomous Prefecture, China. METHODS: A total of 16 hospitals in Hubei Enshi Tujia and Miao Autonomous Prefecture were selected as research centers. A retrospective analysis was performed for the clinical data of 22 294 live births in these 16 hospitals from January to December, 2016 to investigate the incidence rate of neonatal asphyxia and possible contributing factors for the development of severe asphyxia. RESULTS: Of the 22 294 neonates born alive, 733 (3.29%) were diagnosed with neonatal asphyxia, among whom 627 had mild asphyxia and 106 had severe asphyxia. The neonates with low maternal education level, maternal anemia during pregnancy, chorioamnionitis, abnormal amniotic fluid, abnormal umbilical cord, placenta previa, placental abruption, Tujia Minority, preterm birth, and low birth weight had a higher incidence of severe asphyxia (P<0.05). CONCLUSIONS: The incidence rate of neonatal asphyxia in Hubei Enshi Tujia and Miao Autonomous Prefecture is higher. Low maternal education level, maternal anemia during pregnancy, chorioamnionitis, abnormal amniotic fluid, abnormal umbilical cord, placenta previa, placental abruption, Tujia Minority, preterm birth, and low birth weight may be related to the development of severe neonatal asphyxia.


Assuntos
Asfixia Neonatal , Asfixia Neonatal/epidemiologia , China , Humanos , Incidência , Recém-Nascido , Estudos Retrospectivos
3.
Front Oncol ; 11: 779612, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34858859

RESUMO

OBJECTIVE: This study aimed to explore the value of elasticity score (ES) and strain ratio (SR) combined with conventional ultrasound in distinguishing benign and malignant breast masses and reducing biopsy of BI-RADS (Breast Imaging Reporting and Data System) 4a lesions. METHODS: This prospective, multicenter study included 910 patients from nine different hospitals. The acquisition and analysis of conventional ultrasound and strain elastography (SE) were obtained by radiologists with more than 5 years of experience in breast ultrasound imaging. The diagnostic sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under curve (AUC) of conventional ultrasound alone and combined tests with ES and/or SR were calculated and compared. RESULTS: The optimal cutoff value of SR for differentiating benign from malignant masses was 2.27, with a sensitivity of 60.2% and a specificity of 84.8%. When combined with ES and SR, the AUC of the new BI-RADS classification increased from 0.733 to 0.824 (p < 0.001); the specificity increased from 48.1% to 68.5% (p < 0.001) without a decrease in the sensitivity (98.5% vs. 96.4%, p = 0.065); and the PPV increased from 52.2% to 63.7% (p < 0.001) without a loss in the NPV (98.2% vs. 97.1%, p = 0.327). All three combinations of conventional ultrasound, ES, and SR could reduce the biopsy rate of category 4a lesions without reducing the malignant rate of biopsy (from 100% to 68.3%, 34.9%, and 50.4%, respectively, all p < 0.001). CONCLUSIONS: SE can be used as a useful and non-invasive additional method to improve the diagnostic performance of conventional ultrasound by increasing AUC and specificity and reducing the unnecessary biopsy of BI-RADS 4a lesions.

4.
Medicine (Baltimore) ; 99(4): e18803, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31977872

RESUMO

RATIONALE: Intestinal hypoganglionosis most commonly presents in infancy or childhood, with only a few cases reported in adults. Those are mainly diagnosed after elective surgery for long-standing constipation and megacolon. PATIENT CONCERNS: We report a case of a 48-year-old female from China who presented with symptoms of discontinuation of bowel movements for 2 months. A hard, round mass could be felt in her right lower abdomen. DIAGNOSIS: The following examination methods diagnosed acquired segmental sigmoid hypoganglionosis. An abdominal computed tomography revealed a dilatation of the colon and suspicious wall thickening of the sigmoid colon. Anorectal manometry revealed relaxation of the anal sphincter. Histological examination revealed lower numbers and the degeneration of ganglion cells. INTERVENTIONS: Sigmoidectomy and transverse colostomy. OUTCOMES: The patient recovered well from surgery. Three months after the surgery, barium enema revealed a recovery in colorectal dilatation. LESSONS: This case could help raise awareness of acquired segmental hypoganglionosis. Resection of TZ and enterostomy presents an effective remission strategy for patients at risk of anastomotic leakage due to poor intestinal conditions.


Assuntos
Colo Transverso/diagnóstico por imagem , Constipação Intestinal/diagnóstico por imagem , Doenças do Colo Sigmoide/diagnóstico por imagem , Canal Anal/inervação , Colo Transverso/cirurgia , Colostomia , Constipação Intestinal/cirurgia , Feminino , Humanos , Megacolo/diagnóstico por imagem , Pessoa de Meia-Idade , Doenças do Colo Sigmoide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA