Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Rep Pract Oncol Radiother ; 27(1): 97-103, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35402019

RESUMO

Background: This study aims to explore the role of four-dimensional (4D) transperineal ultrasound (TPUS) in the contouring of prostate gland with planning computed tomography (CT) images, in the absence of magnetic resonance imaging (MRI). Materials and methods: Five radiation oncologists (ROs) performed two rounds of prostate gland contouring (single-blinded) on CT-alone and CT/TPUS datasets obtained from 10 patients who underwent TPUS-guided external beam radiotherapy. Parameters include prostate volume, DICE similarity coefficient (DSC) and centroid position. Wilcoxon signed-rank test assessed the significance of inter-modality differences, and the intraclass correlation coefficient (ICC ) reflected inter- and intra-observer reliability of parameters. Results: Inter-modality analysis revealed high agreement (based on DSC and centroid position) of prostate gland contours between CT-alone and CT/TPUS. Statistical significant difference was observed in the superior-inferior direction of the prostate centroid position (p = 0.011). All modalities yielded excellent inter-observer reliability of delineated prostate volume with ICC > 0.9, mean DSC > 0.8 and centroid position: CT-alone (ICC = 1.000) and CT/TPUS (ICC = 0.999) left-right (L/R); CT-alone (ICC = 0.999) and CT/TPUS (ICC = 0.998) anterior-posterior (A/P); CT-alone (ICC = 0.999) and CT/TPUS (ICC = 1.000) superior-inferior (S/I). Similarly, all modalities yielded excellent intra-observer reliability of delineated prostate volume, ICC > 0.9 and mean DSC > 0.8. Lastly, intra-observer reliability was excellent on both imaging modalities for the prostate centroid position, ICC > 0.9. Conclusion: TPUS does not add significantly to the amount of anatomical information provided by CT images. However, TPUS can supplement planning CT to achieve a higher positional accuracy in the S/I direction if access to CT/MRI fusion is limited.

2.
Strahlenther Onkol ; 196(7): 657-663, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31932995

RESUMO

BACKGROUND AND OBJECTIVE: The magnitude of intra-fractional prostate displacement (change from initial position over time) is associated with the duration of the patient lying on the radiotherapy treatment couch. This study reports a minute-by-minute association and calculates the impact of this displacement on duration-dependent margins using real-time intra-fractional position data monitored by four-dimensional transperineal ultrasound (4D TPUS). MATERIALS AND METHODS: A total of 55 patients were recruited prospectively. Intra-fractional position of the prostate was monitored in real-time using a 4D TPUS Clarity® system. A total of 1745 monitoring sessions were analysed. Van Herk's margin recipe (2.5∑ + 1.64((σ2 + σp2)1/2 - σp)) was used to estimate the duration-dependant margins for every minute, up to the 15th minute. Linear regression analysis was then performed on the overall margins against time and direction. RESULTS: The mean intra-fractional position was 0.76 mm Inferior (Inf), 0 mm Lateral (Lat) and 0.94 mm Posterior (Post) at the 15th minute. A minimum margin expansion of 2.42 mm (Superior/Inf), 1.02 mm (Left/Right) and 2.65 mm (Anterior/Post) was required for an 8­minute treatment compared to 4.29 mm (Sup/Inf), 1.84 mm (Lt/Rt) and 4.63 mm (Ant/Post) for a 15-minute treatment. The required margin expansion increased linearly (R2 = 0.99) in all directions (p < 0.01). However, while there was no statistically significant difference (p = 0.10) in the required margin expansion in the Sup/Inf and Ant/Post directions respective of the time duration, the margins were much bigger compared to those in the Lt/Rt direction (p < 0.01). CONCLUSION: We report our experience in deriving the minimum duration-dependant margin to generate the required planning target volume for prostate radiotherapy. The required margin increases linearly in all directions within the 15-min duration; thus, the margin will depend on the duration of the technique chosen (IMRT/VMAT/3DCRT/proton).


Assuntos
Adenocarcinoma/radioterapia , Artefatos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Erros de Configuração em Radioterapia/prevenção & controle , Radioterapia de Intensidade Modulada , Ultrassonografia/métodos , Adenocarcinoma/diagnóstico por imagem , Sistemas Computacionais , Humanos , Masculino , Movimento (Física) , Posicionamento do Paciente , Períneo , Neoplasias da Próstata/diagnóstico por imagem , Fatores de Tempo
3.
Phys Med Biol ; 68(15)2023 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-37437590

RESUMO

Objective. Automatic deformable image registration (DIR) is a critical step in adaptive radiotherapy. Manually delineated organs-at-risk (OARs) contours on planning CT (pCT) scans are deformably registered onto daily cone-beam CT (CBCT) scans for delivered dose accumulation. However, evaluation of registered contours requires human assessment, which is time-consuming and subjects to high inter-observer variability. This work proposes a deep learning model that allows accurate prediction of Dice similarity coefficients (DSC) of registered contours in prostate radiotherapy.Approach. Our dataset comprises 20 prostate cancer patients with 37-39 daily CBCT scans each. The pCT scans and planning contours were deformably registered to each corresponding CBCT scan to generate virtual CT (vCT) scans and registered contours. The DSC score, which is a common contour-based validation metric for registration quality, between the registered and manual contours were computed. A Siamese neural network was trained on the vCT-CBCT image pairs to predict DSC. To assess the performance of the model, the root mean squared error (RMSE) between the actual and predicted DSC were computed.Main results. The model showed promising results for predicting DSC, giving RMSE of 0.070, 0.079 and 0.118 for rectum, prostate, and bladder respectively on the holdout test set. Clinically, a low RMSE implies that the predicted DSC can be reliably used to determine if further DIR assessment from physicians is required. Considering the event where a registered contour is classified as poor if its DSC is below 0.6 and good otherwise, the model achieves an accuracy of 92% for the rectum. A sensitivity of 0.97 suggests that the model can correctly identify 97% of poorly registered contours, allowing manual assessment of DIR to be triggered.Significance. We propose a neural network capable of accurately predicting DSC of deformably registered OAR contours, which can be used to evaluate eligibility for plan adaptation.


Assuntos
Neoplasias de Cabeça e Pescoço , Masculino , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador/métodos , Algoritmos
4.
Cardiooncology ; 8(1): 4, 2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35287756

RESUMO

BACKGROUND: Androgen deprivation therapy (ADT) and radiotherapy (RT) are the mainstay treatment for localized prostate cancer and recurrence after surgery. Cardiovascular (CV) toxicity of ADT is increasingly recognized, and the risk relates to pre-existing risk factors and ADT modalities. Despite ethnic differences in the prevalence of CV risk factors and variations of CV mortality, data on ADT-related cardiotoxicities in the Asian population remain inconclusive. Our registry-based study investigated ADT-related major adverse cardiovascular events (MACE) after primary or salvage RT. METHODS: Our study combined two prospectively established registry databases from National Cancer Center Singapore and National Heart Center Singapore. The primary endpoint is time to first MACE after treatment. MACE is defined as myocardial infarction, stroke, unstable angina, or cardiovascular death. Two types of propensity score adjustments, including ADT propensity score as a covariate in the multivariable regression model and propensity score weighting, were applied to balance baseline features and CV risk factors between RT alone and RT + ADT groups. RESULTS: From 2000 to 2019, 1940 patients received either RT alone (n = 494) or RT + ADT (n = 1446) were included. After a median follow-up of 10 years (RT) and 7.2 years (RT+ ADT), the cumulative incidence of MACE at 1, 3 and 9 years was 1.2, 5 and 16.2% in RT group, and 1.1, 5.2 and 17.6% in RT + ADT group, respectively. There were no differences in the incidence of MACE between 2 groups (HR 1.01, 95% CI 0.78-1.30, p = 0.969). Pre-treatment CV risk factors were common (80%), and CV disease (15.9%) was the second leading cause of death after prostate cancer (21.1%). On univariate analysis, older age, Indians and Malays, pre-existing CV risk factors, and history of MACE were associated with higher MACE risk. After propensity score adjustments, there remained no significant differences in MACE risk between RT + ADT and RT group on multivariable analysis. CONCLUSIONS: In our registry-based study, ADT is not associated with increased risk of major cardiovascular events among Southeast Asian men with prostate cancer after curative radiotherapy.

5.
J Med Radiat Sci ; 68(2): 196-202, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33017863

RESUMO

This technical evaluation aims to provide practice 'how to' guidelines for radiation therapists (RTs) when positioning a transperineal ultrasound (TPUS) probe during prostate radiotherapy. Recommendations and practical tips will be provided for the best practice in TPUS-guided workflow to obtain optimal ultrasound images for accurate interpretation and registration of the prostate gland. This will assist the RTs in making consistent and accurate clinical decision in an ultrasound-guided radiotherapy workflow for prostate treatment. The implementation process and the associated successes and challenges will also be described to assist institutions who may be investigating the potential of implementing this system.


Assuntos
Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Ultrassonografia
6.
Pract Radiat Oncol ; 11(6): 463-469, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34411756

RESUMO

PURPOSE: Permanent tattoo marks used in radiation therapy remain for the duration of treatment and essentially for the rest of the patient's life. This study compared the initial positioning setup errors and body image perception between patients with ultraviolet (UV) and conventional dark ink tattoos. METHODS AND MATERIALS: Thirty-four patients from February 2018 to March 2019, who underwent radiation therapy (RT) to the breast or chest wall for ductal carcinoma in situ or breast cancer were prospectively recruited and randomized (1:1) to receive either conventional dark ink or UV ink tattoos. Each patient received the assigned tattoos during computed tomography (CT) simulation and initial treatment setup shifts were compared. A 9-item body-image survey was administered to all patients at 3 time points: CT simulation, last week of RT, and 6 weeks post-RT. Feedback from CT and treatment staff in terms of setup time and challenges were collated. RESULTS: The median age of the patient cohort was 46 years old. No statistically significant difference was observed between the mean setup errors for the conventional dark ink group (0.11 cm inferior, 0.01 cm left, 0.11 cm posterior) and UV ink group (0.01 cm superior, 0.01 cm right, 0.06 cm posterior; P = NS). Similar responses were observed in the body-image survey between the 2 groups across all time points (P = NS). The majority of the patients (dark ink 82.3% vs UV ink 88.2%) did not feel less sexually attractive as a result of the tattoo at 6 weeks post-RT. At 6 weeks post-RT, patients in both groups were satisfied with the appearance of the tattoo and did not feel cautious about their choice of clothes (82.4% vs 88.2%; P = NS). In addition, 88.6% of staff (n = 35) felt minimum effect of UV ink on the overall setup time, and 94.3% found no difficulty localizing the UV ink tattoos during patient positioning. CONCLUSIONS: No difference in setup accuracy was found using UV ink tattoos, and it could be implemented clinically with minimal effect on the existing workflow. Patients expressed high satisfaction and self-confidence with the use of UV ink tattoos.


Assuntos
Tatuagem , Humanos , Tinta , Pessoa de Meia-Idade , Estudos Prospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
7.
Artigo em Inglês | MEDLINE | ID: mdl-32128458

RESUMO

Perception of the radiation oncologists (ROs) and radiation therapists (RTTs) on site-specific advanced practice (SSAP) roles for RTTs, the establishment of SSAP in radiotherapy and the possible implication on current services in Singapore were assessed. Opinions of ROs and RTTs on management support, driving forces, restraints and implication upon successful establishment of SSAP were obtained. Main findings include strong RO's support for SSAP development and RTTs' requisition for fair opportunities on role development. Other potential benefits include RTTs' career advancement, job satisfaction and retention. Enhancement of inter-professional relationship, service quality and patient satisfaction is anticipated with greater communication and collaboration.

8.
Diagnostics (Basel) ; 10(11)2020 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-33212793

RESUMO

A commercial deep learning (DL)-based automated segmentation tool (AST) for computed tomography (CT) is evaluated for accuracy and efficiency gain within prostate cancer patients. Thirty patients from six clinics were reviewed with manual- (MC), automated- (AC) and automated and edited (AEC) contouring methods. In the AEC group, created contours (prostate, seminal vesicles, bladder, rectum, femoral heads and penile bulb) were edited, whereas the MC group included empty datasets for MC. In one clinic, lymph node CTV delineations were evaluated for interobserver variability. Compared to MC, the mean time saved using the AST was 12 min for the whole data set (46%) and 12 min for the lymph node CTV (60%), respectively. The delineation consistency between MC and AEC groups according to the Dice similarity coefficient (DSC) improved from 0.78 to 0.94 for the whole data set and from 0.76 to 0.91 for the lymph nodes. The mean DSCs between MC and AC for all six clinics were 0.82 for prostate, 0.72 for seminal vesicles, 0.93 for bladder, 0.84 for rectum, 0.69 for femoral heads and 0.51 for penile bulb. This study proves that using a general DL-based AST for CT images saves time and improves consistency.

9.
Phys Imaging Radiat Oncol ; 5: 102-107, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33458378

RESUMO

BACKGROUND AND PURPOSE: During radiotherapy, prostate motion changes over time. Quantifying and accounting for this motion is essential. This study aimed to assess intra-fraction prostate motion and derive duration-dependent planning margins for two treatment techniques. MATERIAL AND METHODS: A four-dimension (4D) transperineal ultrasound Clarity® system was used to track prostate motion. We analysed 1913 fractions from 60 patients undergoing volumetric-modulated arc therapy (VMAT) to the prostate. The mean VMAT treatment duration was 3.4 min. Extended monitoring was conducted weekly to simulate motion during intensity-modulated radiation therapy (IMRT) treatment (an additional seven minutes). A motion-time trend analysis was conducted and the mean intra-fraction motion between VMAT and IMRT treatments compared. Duration-dependent margins were calculated and anisotropic margins for VMAT and IMRT treatments were derived. RESULTS: There were statistically significant differences in the mean intra-fraction motion between VMAT and the simulated IMRT duration in the inferior (0.1 mm versus 0.3 mm) and posterior (-0.2 versus -0.4 mm) directions respectively (p ≪ 0.01). An intra-fraction motion trend inferiorly and posteriorly was observed. The recommended minimum anisotropic margins are 1.7 mm/2.7 mm (superior/inferior); 0.8 mm (left/right), 1.7 mm/2.9 mm (anterior/posterior) for VMAT treatments and 2.9 mm/4.3 mm (superior/inferior), 1.5 mm (left/right), 2.8 mm/4.8 mm (anterior/posterior) for IMRT treatments. Smaller anisotropic margins were required for VMAT compared to IMRT (differences ranging from 1.2 to 1.6 mm superiorly/inferiorly, 0.7 mm laterally and 1.1-1.9 mm anteriorly/posteriorly). CONCLUSIONS: VMAT treatment is preferred over IMRT as prostate motion increases with time. Larger margins should be employed in the inferior and posterior directions for both treatment durations. Duration-dependent margins should be applied in the presence of prolonged imaging and verification time.

10.
Artigo em Inglês | MEDLINE | ID: mdl-32095569

RESUMO

BACKGROUND AND PURPOSE: Inconsistent bladder and rectal volumes have been associated with motion uncertainties during prostate radiotherapy. This study investigates the impact of these volumes to determine the optimal bladder volume. MATERIALS AND METHODS: 60 patients from two Asian hospitals were recruited prospectively. 1887 daily cone-beam computed tomography (CBCT) images were analysed. Intra-fraction motion of the prostate was monitored real-time using a four-dimension transperineal ultrasound (4D TPUS) Clarity® system. The impact of planned bladder volume, adequacy of daily bladder filling, and rectum volume on mean intra-fraction motion of the prostate was analysed. Patients' ability to comply with the full bladder hydration protocol and level of frustration was assessed using a questionaire. Acute side effects were assessed using the Common Terminology Criteria for Adverse Events (CTCAE) version 3.0 and quality of life (QoL) assessed using the International Prostate Symptom Score (IPSS). RESULTS: The mean (SD) bladder and rectum volumes achieved during daily treatment were 139.7 cm3 (82.4 cm3) and 53.3 cm3 (18 cm3) respectively. Mean (SD) percentage change from planned CT volumes in bladder volume was reduced by 8.2% (48.7%) and rectum volume was increased by 12.4% (42.2%). Linear Mixed effect model analysis revealed a reduction in intra-fraction motion in both the Sup/Inf (p = 0.008) and Ant/Post (p = 0.0001) directions when the daily bladder was filled between 82 and 113% (3rd Quartiles) of the planned CT volumes. A reduction in intra-fraction motion of the prostate in the Ant/Post direction (z-plane) (p = 0.03) was observed when the planned bladder volume was greater than 200 ml. Patients complied well with the hydration protocol with minimal frustration (mean (SD) scores of 2.1 (1.4) and 1.8 (1.2) respectively). There was a moderate positive correlation (0.496) between mean bladder volume and IPSS reported post-treatment urinary straining (p = 0.001). CONCLUSIONS: A planned bladder volume >200 cm3 and daily filling between 82 and 113%, reduced intra-fraction motion of the prostate. The hydration protocol was well tolerated.

11.
Adv Radiat Oncol ; 2(2): 125-131, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28740923

RESUMO

PURPOSE: Our purpose was to investigate interfraction setup error of the immobilization device required to implement transperineal ultrasound compared with the current, standard immobilization device. Patient comfort and radiation therapist (RT) satisfaction were also assessed. METHODS AND MATERIALS: Cone beam computed tomography images were acquired before 4069 fractions from 111 patients (control group, n = 56; intervention group, n = 55) were analyzed. The intervention group was immobilized using the Clarity Immobilization System (CIS), comprising a knee rest with autoscan probe kit and transperineal ultrasound probe (n = 55), and control group using a leg immobilizer (LI) (n = 56). Interfraction setup errors were compared for both groups. Weekly questionnaires using a 10-point visual analog scale were administered to both patient groups to measure and compare patient comfort. RT acceptance for both devices was also compared using a survey. RESULTS: There was no significant difference in the magnitude of interfraction cone beam computed tomography-derived setup shifts in the lateral and anteroposterior direction between the LI and CIS (P = .878 and .690, respectively). However, a significant difference (P = .003) was observed in the superoinferior direction between the 2 groups of patients. Patient-reported level of comfort and stability demonstrated no significant difference between groups (P = .994 and .132). RT user acceptance measures for the LI and CIS were ease of handling (100% vs 53.7%), storage (100% vs 61.1%), and cleaning of the devices (100% vs 64.8%), respectively. CONCLUSIONS: The CIS demonstrated stability and reproducibility in prostate treatment setup comparable to LI. The CIS device had no impact on patient comfort; however, RTs indicated a preference for LI over the CIS mainly because of its weight and bulkiness.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA