Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Assunto principal
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
World Neurosurg ; 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39147021

RESUMO

BACKGROUND/OBJECTIVE: Broad-based sidewall aneurysms of the carotid artery are primarily treated endovascularly. However, recurrence or rupture after treatment still poses a significant risk. Hence, reliable animal models mimicking this aneurysm type are essential for to evaluate the performance of new advanced endovascular devices. METHODS: Experimental aneurysms were created in 12 New Zealand white rabbits (2.5-3.5 kg). The human carotid siphon was mimicked with an end-to-end anastomosis of both common carotid arteries. A venous pouch was sutured on the convexity to mimic a broad-based side wall aneurysm. Patency and configuration were investigated 4 weeks postoperatively by 3-T magnetic resonance angiography. To compare flow conditions of broad-based sidewall aneurysms in rabbits and humans, exemplary computational fluid dynamics simulations were performed using species-specific blood viscosity values. RESULTS: We were able to achieve 0% peri- or postoperative mortality. Patency was confirmed by 3-T magnetic resonance angiography in 11 of 12 aneurysms (91.7%). Aneurysm lengths ranged from 6.4 to 9.8 mm and aneurysm necks from 7.3 to 9.8 mm. Computational fluid dynamics showed simple flow profiles with one vortex in rabbit as well as in human aneurysms. Wall shear stress rates were comparable using species-specific blood viscosity values (rabbit mean 1.65 Pa vs. human mean 1.7 Pa). CONCLUSIONS: The broad-based curved sidewall aneurysm model mimicking the carotid siphon showed high aneurysm patency rates with low morbidity. High comparability with human flow patterns and human intranaeurysmal biomechanical forces was shown using simulations.

2.
J Vis Exp ; (199)2023 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-37747223

RESUMO

Giant aneurysms are dangerous lesions requiring endovascular treatment, with high rates of aneurysm recanalization and re-rupture. Reliable in vivo models are rare but are required for testing new endovascular devices. We demonstrate the technical aspects of the creation of giant bifurcation aneurysms in New Zealand white rabbits (2.5-5.5 kg). A 25-30 mm long venous pouch is taken from the external jugular vein, and a bifurcation between both carotid arteries is created microsurgically. The pouch is sutured in the bifurcation to mimic a giant aneurysm. This protocol summarizes our previously published standard technique for venous pouch true arterial bifurcation aneurysms and highlights its essential modification steps for giant aneurysms. Using this modified technique, we were able to create an animal model for giant aneurysms with high comparability to humans regarding the hemodynamics and coagulation systems. Furthermore, low morbidity and high aneurysm patency rates were achieved. The proposed giant aneurysm model offers an excellent possibility for testing new endovascular devices.


Assuntos
Aneurisma , Humanos , Coelhos , Animais , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Coagulação Sanguínea , Veias Jugulares , Modelos Animais , Veia Subclávia
3.
Artigo em Inglês | MEDLINE | ID: mdl-35453161

RESUMO

Meningeal metastasis has been reported as a very rare cause of chronic subdural hematoma (CSH). Here, we report a female patient who had undergone initial burr hole drainage of a CSH at an outside hospital. Postoperatively, the patient additionally suffered from visual impairment due to bilateral papilledema and the patient was eventually transferred to our neurosurgical department for additional treatment. A craniotomy was performed and due to intraoperative suspicious findings, histopathologic samples were obtained that revealed a metastasis of thus far undiagnosed triple negative breast cancer. Furthermore, the patient was suspected to have a partial cerebral venous thrombosis (CVT). Our case report addresses this extremely rare clinical constellation. We provide a detailed overview on our patient's clinical and radiologic course, and discuss the potential association of CSH with meningeal metastasis and bilateral papilledema.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA