RESUMO
BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%-3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4-22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P=0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P=1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P=0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1-4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P=0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P=0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P=0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03383445.
Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Acidente Vascular Cerebral/etiologiaRESUMO
PURPOSE OF REVIEW: Invasive cardiologists are exposed to large amounts of ionizing radiation. This review aims to summarize the main occupational risks in a radiation-exposed cardiology practice. RECENT FINDINGS: We carried out a literature review on the subject. The studies reviewed allowed us to list six main health risk categories possibly associated with radiation exposure among cardiologists: deoxyribonucleic acid (DNA) and biochemical damages; cancers; ocular manifestations; olfaction, vascular, and neuropsychological alterations; musculoskeletal problems; and reproductive risks. Our descriptive analysis demonstrates higher risks of DNA damage and lens opacities among radiation-exposed cardiology staff. Surveys and questionnaires have demonstrated a higher risk of musculoskeletal disease in exposed workers. Studies reported no difference in cancer frequency between radiation-exposed workers and controls. Changes in olfactory performance, neuropsychological aspects, and vascular changes have also been reported. Limited literature supports the security of continuing radiation-exposed work during pregnancy. Therefore, there is an urgent need to increase knowledge of the occupational risks of radiation exposure and to adopt technologies to reduce them.
Assuntos
Cardiologistas , Exposição Ocupacional , Exposição à Radiação , Humanos , Exposição Ocupacional/efeitos adversos , Exposição à Radiação/efeitos adversos , Lesões por Radiação/etiologia , Doenças Profissionais/etiologia , Radiação Ionizante , Fatores de Risco , Dano ao DNA/efeitos da radiaçãoRESUMO
BACKGROUND: Peanut specific IgE (sIgE) can lead to false-positive results. OBJECTIVE: We aimed to assess whether peanut sIgE to total IgE (tIgE) ratio improves accuracy in predicting clinical reactivity to peanut compared to peanut sIgE alone, which has not been explored in the adult population so far. METHOD: A retrospective chart review was performed for adults who underwent peanut oral food challenge (OFC) and/or oral immunotherapy (OIT) at the Centre Hospitalier de l'Université de Montréal's allergy clinic between January 2017 and July 2021. Patients with positive peanut OFC and/or undergoing OIT were considered peanut-allergic. Patients with negative OFC were considered peanut-tolerant. Peanut sIgE to tIgE ratios were calculated and performance characteristics of the sIgE to tIgE ratio were compared to sIgE alone by using receiver operator characteristics curves. RESULTS: Forty-two patients were included (52% male) with a median age of 26 years (range 14-54). Forty-five percent had atopic dermatitis. Median sIgE levels were 2.64 kUA/L (range 0.1-100), median tIgE levels were 154 kUA/L (range 19-3,400), and median sIgE to tIgE ratio was 0.66% (range 0.04-38.3). Twenty-four patients (57%) were classified as peanut-allergic and 18 (43%) as peanut tolerant. The area under the curve for peanut sIgE was 0.921 compared to 0.926 for peanut sIgE/tIgE (p not statistically significant). CONCLUSIONS: We found that there was no significant benefit in using peanut sIgE to tIgE ratio over sIgE alone to predict peanut reactivity in an adult population. Larger prospective studies are needed to further confirm these findings.
Assuntos
Arachis , Hipersensibilidade a Amendoim , Adolescente , Adulto , Alérgenos , Feminino , Humanos , Imunoglobulina E , Masculino , Pessoa de Meia-Idade , Hipersensibilidade a Amendoim/diagnóstico , Estudos Retrospectivos , Adulto JovemRESUMO
BACKGROUND: Bronchoscopy is a safe procedure which is frequently performed for the investigation of respiratory diseases. Current guidelines recommend to delay bronchoscopy for 4-6 weeks after acute coronary syndrome (ACS), as this period is theoretically considered at risk for new onset of ACS. We therefore aimed to evaluate the safety and the tolerance of bronchoscopy in patients with ACS (≤30 days) and to compare outcomes with matched controls. METHODS: All consecutive patients who had a bronchoscopy performed in the first 30 days after an ACS in the bronchoscopy suite were included. A group of patients with ACS who did not undergo bronchoscopy (controls) were also included and matched for age, sex, type of ACS, and severity of ACS (GRACE score). RESULTS: Of the 13,646 patients who underwent bronchoscopy between 2010 and 2019, 2,181 had an history of ACS and among those, 87 patients had an ACS (19 with STEMI, 52 with NSTEMI, and 16 unstable angina). Mean interval between ACS and bronchoscopy was of 10.1 ± 8.9 days. Systolic blood pressure and heart rate significantly increased and oxygen saturation significantly decreased during bronchoscopy. The most frequent adverse event was desaturation which occurred in 26% of patients. Reinfarction rate (1.1% vs. 2.3% p = 1.00) and all-cause 30-day mortality (2.3% vs. 4.6%; p = 0.68) were similar in patients who underwent bronchoscopy and in matched controls (n = 87). CONCLUSION: Our study reinforces the safety of bronchoscopy after ACS. When clinically indicated with potential benefits outweighing risks, ACS should not contraindicate bronchoscopy.
Assuntos
Síndrome Coronariana Aguda , Angina Instável , Broncoscopia/efeitos adversos , HumanosRESUMO
BACKGROUND: In patients undergoing left atrial appendage (LAA) closure, an accurate sizing of the LAA is key to optimize device sizing, procedural success and reduce complications. Previous studies have shown that intraprocedural volume loading increases LAA dimensions and improves device sizing. However, the safety and effects on LAA and device sizing of administering a fluid bolus during pre-procedural transesophageal echocardiography (TEE) are unknown. The aim of this study was to determine the safety and impact on LAA dimensions and device sizing of an intravenous (IV) fluid bolus administered during TEE in the setting of the pre-procedural work-up for LAA closure. METHODS: The study included a total of 72 patients who underwent TEE to assess suitability for LAAC and received a 500 ml IV bolus of normal saline. The LAA landing zone (LZ) and depth were measured by TEE before and after volume loading, and these measurements were used to predict the device size implanted during a subsequent percutaneous LAAC procedure. RESULTS: There were no complications associated with volume loading. The baseline mean LZ was 19.6 ± 3.6 mm at 90o, and 20.2 ± 4.1 mm at 135o. Following fluid bolus, the maximum diameter increased 1.5 ± 1.0 mm at 90o (p<0.001), and 1.3 ± 1.0 mm at 135o (p<0.001). The baseline mean depth of the LAA was 26.5 ± 5.5 mm at 90o, and 23.9 ± 5.8 mm at 135o. After fluid bolus, the mean depth increased by 1.5 ± 1.8 mm (p<0.001) and 1.6 ± 2.0 (p<0.001), at 90o and 135o, respectively. Sizing based on post-bolus measurements of the LZ significantly improved the agreement with the final device size selection during the procedure in 71.0% of cases (vs. 42.0% with pre-bolus measurements). CONCLUSIONS: Volume loading during ambulatory TEE as part of the pre-procedural work-up of LAAC is safe and significantly increases LAA dimensions. This strategy may become the new standard, particularly in centers performing LAAC with no TEE guidance, as it improves LAA sizing and more accurately predicts the final device size.
Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia Transesofagiana/métodos , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Feminino , Humanos , Masculino , Período Pré-Operatório , Reprodutibilidade dos Testes , Estudos RetrospectivosRESUMO
BACKGROUND: Although there have been several reports documenting complications related with transesophageal echocardiography (TEE) manipulation following cardiac surgery, there is a paucity of data regarding the safety of TEE used to guide catheter-based interventions. The aim of this study was to determine the prevalence, types and risk factors of complications associated with procedures requiring active TEE guidance. METHODS: This study included 1249 consecutive patients undergoing either transcatheter aortic valve implantation (TAVI), Mitraclip, left atrial appendage occlusion (LAAO) or paravalvular leak closure (PVLC). Patients were divided into 2 cohorts based on the degree of probe manipulation required to guide the procedure and the risk of developing a TEE-related complication: low-risk (TAVI, nâ¯=â¯1037) and high-risk (Mitraclip, LAAO and PVLC, nâ¯=â¯212). Patients were further analyzed according to the occurrence of major and minor TEE-related complications. RESULTS: The overall incidence of TEE-related complications was 0.9% in the TAVI group and 6.1% in the rest of the cohort (Pâ¯<â¯.001). Patients in the high-risk cohort had also a higher incidence of major-complications (2.8% vs 0.6%, Pâ¯=â¯.008), and factors associated with an increased risk were being underweight, having a prior history of gastrointestinal bleeding and the use of chronic steroids/immunosuppressive medications. Procedural time under TEE-manipulation was longer in patients exhibiting complications and was an independent predictor of major complications (ORâ¯=â¯1.13, 95% CI 1.01-1.25, for each 10 minutes increments in imaging time). Patients with major complications undergoing Mitraclip had the longest median time under TEE-manipulation (297 minutes) and a risk of developing a major-complication that was 10.64 times higher than the rest of the cohort (95% CI 3.30-34.29, Pâ¯<â¯.001). CONCLUSION: The prevalence of TEE-related complications associated with interventional procedures is higher than previously reported. Undergoing a prolonged procedure, particularly in the setting of Mitraclip, was the main factor linked to TEE-related complications.
Assuntos
Cateterismo Cardíaco/métodos , Transtornos de Deglutição/epidemiologia , Ecocardiografia Transesofagiana/efeitos adversos , Esôfago/lesões , Hemorragia Gastrointestinal/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/cirurgia , Transfusão de Sangue , Perfuração Esofágica/epidemiologia , Perfuração Esofágica/etiologia , Feminino , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Humanos , Lacerações/epidemiologia , Lacerações/etiologia , Masculino , Valva Mitral/cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Cirurgia Assistida por Computador , Fatores de TempoRESUMO
AIMS: This study sought to determine the timing and evolution over time of advanced conduction disturbances (CDs) in patients with baseline right bundle branch block (RBBB) undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: One hundred and ten consecutive patients with pre-existing RBBB were included (out of 1341, 8.2%). All arrhythmias during the hospitalization period were recorded. Follow-up was performed at 30 days, 1 year, and yearly thereafter. Conduction recovery and ventricular pacing percentage (VPP) was evaluated at 30 days in those patients with permanent pacemaker implantation (PPMI). Sixty-one (55.5%) patients suffered advanced CDs [97% complete or high-degree atrioventricular block (CHB/HAVB)], and the vast majority (98%) occurred within the first 3 days post-procedure (intraprocedural: 85%). Fifty-two (47.3%) patients had PPMI (vs. 11.0% in non-RBBB patients, P < 0.001). Ventricular pacing percentage at 1 month was higher in patients with persistent-intraprocedural CHB/HAVB compared to those with transient-intraprocedural or post-procedural CHB/HAVB [99 (interquartile range, IQR 97-100)% vs. 72 (IQR 30-99)%, P = 0.02]. Complete recovery (VPP < 1%) was observed in only one patient (2%) with CHB/HAVB. After hospital discharge, no symptomatic bradyarrhythmias or sudden death occurred within 30 days. Patients with pre-existing RBBB exhibited a higher risk of PPMI at 4-year follow-up (26% vs. 8% in non-RBBB patients, P < 0.001). CONCLUSION: In patients with pre-existing RBBB, the vast majority of advanced CDs occurred within the 3 days following TAVR, and most did not recover at 1-month, particularly those with intra-procedural persistent CHB/HAVB. These results should help to determine the hospitalization length and timing of PPMI in RBBB patients undergoing TAVR.
Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Eletrocardiografia , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoAssuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Hemodinâmica , Resultado do Tratamento , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco , Desenho de PróteseRESUMO
OBJECTIVES: To report on the feasibility and technical differences between coronary procedures performed before and after TAVR with the balloon-expandable Edwards-SAPIEN or the SAPIEN XT valves. BACKGROUND: Coronary artery disease (CAD) and aortic stenosis often coexist. Transcatheter aortic valve replacement (TAVR) is emerging as a treatment for younger and lower surgical risk patients who might not present with clinically evident CAD before TAVR. The demand for performing post-TAVR coronary angiograms (CAs) and percutaneous coronary interventions (PCIs) will thus increase, posing new technical challenges. METHODS: Over 1000 TAVRs were performed at the Quebec Heart and Lung Institute, of which 616 with the abovementioned valves. Of these, 28 patients had an analyzable pre- and post-TAVR CAs and 13 patients had pre- and post-TAVR PCIs performed. Procedural characteristics were gathered from all coronary procedures and subsequently compared amongst the same type of procedure performed at these two distinct time periods. RESULTS: Neither CAs-nor PCIs-performed after valve implantation revealed significant differences regarding arterial access site, catheter diameter, number of diagnostic or guiding catheters used, procedural duration, fluoroscopy time, or achievement of selective coronary injection. Lesion location and classification, as well as the preference of using a drug-eluting stent, remained unchanged. During post-TAVR CA, the amount of contrast delivered and the radiation dose area product were significantly lower compared with pre-TAVR CA values. CONCLUSIONS: Performance of CA and PCI after TAVR with a balloon-expandable valve appears unaffected by its presence.
Assuntos
Valvuloplastia com Balão , Angiografia Coronária , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Doses de RadiaçãoRESUMO
BACKGROUND: Significant mitral regurgitation (MR) is associated with poorer outcomes in patients undergoing transcatheter aortic valve replacement (TAVR). Factors associated with MR improvement have not been studied thoroughly. METHODS: Retrospective analysis of consecutive patients treated with TAVR with more than mild MR at baseline. MR evolution was assessed at 1-3 and 6-12 months after intervention. MR severity and mechanisms were assessed by echocardiography. Mitral annulus calcification (MAC) was quantified using preoperative cardiac CT. RESULTS: From 674 consecutive TAVR recipients, 78 with more than mild MR had a 6-12 months follow-up. Following TAVR, MR improved in 34 patients (43%), remained stable in 38 (49%) and worsened in 6 (8%). Patients with MR improvement had greater tenting area (141 ± 56 vs. 99 ± 40 mm2 , P < 0.01), tenting height (7.2 ± 1.9 vs. 5.6 ± 1.9 mm, P < 0.01) and lower ejection fraction (43 ± 16 vs. 52 ± 14%, P = 0.01). MAC was frequent (87.7% of patients) and a trend in greater MAC was observed in patients without MR improvement (3560 ± 5587 vs. 2053 ± 2800, P = 0.16). In multivariable analysis, tenting area (OR per 10 mm2 increase: 1.012, 95% CI, 1.001-1.024 P = 0.039) and annulus calcifications associated with leaflet restriction (OR = 0.108, 95% CI, 0.012-0.956, P = 0.045) were independently associated with MR outcome after TAVR. CONCLUSION: Larger mitral valve tenting area was associated with more improvement of MR after TAVR whereas extensive MAC associated with leaflet restriction was associated with less improvement. This may help in the clinical decision-making process of TAVR candidates with concomitant MR.
Assuntos
Ecocardiografia/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Insuficiência da Valva Mitral/fisiopatologia , Complicações Pós-Operatórias/fisiopatologia , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do TratamentoRESUMO
BACKGROUND: At present, there are no objective data specifically examining the clinical impact of variations in exercise capacity post-transcatheter aortic valve replacement (TAVR). We describe the changes in exercise capacity between baseline and 6 months post-TAVR, and ascertain factors associated with and clinical implications of a lack of improvement in exercise capacity post-TAVR. METHODS: A total of 305 patients (mean age, 79±9 years; 44% men; Society of Thoracic Surgeons predicted risk mortality score, 6.7±4.2%) undergoing TAVR completed both baseline and follow-up exercise capacity assessments at 6 months post-TAVR. Exercise capacity was evaluated by the 6-minute walk test (6MWT). Clinical outcomes were compared between patients displaying greater than (n=152; improving group) versus less than (n=153; nonimproving group) the median percentage change in distance walked between baseline and 6-month follow-up examinations. The primary outcome measure was clinical event rates, measured from the 6-month post-TAVR period onward. Further dichotomization according to baseline 6MWT distance (less than versus more than median walking distance, or slow walker versus fast walker) was also assessed. RESULTS: The mean overall distances walked pre- and post-TAVR (6 months post-TAVR) were 204±119 and 263±116 m, respectively (Δ6MWT=60±106 m), with 219 (72%) patients demonstrating an increase in their walking distance (median percentage increase of the entire population was 20% [interquartile range, 0%-80%]). Factors independently correlated with reduced exercise capacity improvement included a range of baseline clinical characteristics (older age, female sex, chronic obstructive pulmonary disease; P<0.05 for all), periprocedural major or life-threatening bleeding (P=0.009) and new-onset anemia at 6 months post-TAVR (P=0.009). Failure to improve the 6MWT distance by at least 20% was independently associated with all-cause mortality (P=0.002) and cardiovascular death or rehospitalization for cardiovascular causes (P=0.001). Baseline slow walkers who were able to improve the 6MWT distance presented with significantly better outcomes than nonimprovers (P=0.01 for all-cause mortality; P=0.001 for cardiovascular end point). CONCLUSIONS: Approximately one-third of patients undergoing TAVR did not improve their exercise capacity postprocedure. The lack of functional improvement post-TAVR was predicted by a mix of baseline and periprocedural factors translating into poorer clinical outcomes. These results suggest that systematically implementing exercise capacity assessment pre- and post-TAVR may help to improve patient risk stratification.
Assuntos
Estenose da Valva Aórtica/cirurgia , Terapia por Exercício , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/terapia , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Análise Multivariada , Prognóstico , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter , Resultado do TratamentoRESUMO
OBJECTIVES: To assess the clinical characteristics, management, and outcomes of patients diagnosed with infective endocarditis (IE) after edge-to-edge mitral valve repair with the MitraClip device. BACKGROUND: Transcatheter edge-to-edge mitral valve repair has emerged as an alternative to surgery in high-risk patients. However, few data exist on IE following transcatheter mitral procedures. METHODS: Four electronic databases (PubMed, Google Scholar, Embase, and Cochrane Library) were searched for original published studies on IE after edge-to-edge transcatheter mitral valve repair from 2003 to 2017. RESULTS: A total of 10 publications describing 12 patients with definitive IE (median age 76 years, 55% men) were found. The mean logistic EuroSCORE/EuroSCORE II were 41% and 45%, respectively. The IE episode occurred early (within 12 months post-procedure) in nine patients (75%; within the first month in five patients). Staphylococcus aureus was the most frequent (60%) causal microorganism, and severe mitral regurgitation was present in all cases but one. Surgical mitral valve replacement (SMVR) was performed in most (67%) patients, and the mortality associated with the IE episode was high (42%). CONCLUSIONS: IE following transcatheter edge-to-edge mitral valve repair is a rare but life-threatening complication, usually necessitating SMVR despite the high-risk profile of the patients. These results highlight the importance of adequate preventive measures and a prompt diagnosis and treatment of this serious complication.
Assuntos
Endocardite Bacteriana/microbiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas/efeitos adversos , Valva Mitral/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Endocardite Bacteriana/mortalidade , Endocardite Bacteriana/fisiopatologia , Endocardite Bacteriana/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/microbiologia , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/microbiologia , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/fisiopatologia , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
This article is a continuation of our previously published annual reviews of transcatheter aortic valve replacement (TAVR). In 2017, TAVR further established a foothold in the management of intermediate risk patients with the publication of SURTAVI trial. Randomized trials also addressed the use of cerebral protection during TAVR and single versus dual antiplatelet therapy after TAVR. Newer generation valve systems continued to be studied for their efficacy and safety. This paper summarizes the major studies published in 2017.
Assuntos
Estenose da Valva Aórtica , Complicações Pós-Operatórias/prevenção & controle , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Prognóstico , Risco Ajustado , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodosRESUMO
OBJECTIVES: We report the initial experience of percutaneous left atrial appendage (LAA) closure with the Ultraseal device. BACKGROUND: LAA closure is an alternative to oral anticoagulation for stroke prevention in patients with nonvalvular atrial fibrillation (NVAF) and high risk of bleeding. The Ultraseal device is a new LAA closure prosthesis that consists of a distal soft bulb and a proximal sail attached by an articulating joint that allows a high degree of device conformability to the different variations of the LAA anatomy. METHODS: We included 12 consecutive patients with NVAF who underwent LAA closure with the Ultraseal device between January and December 2015 in our center. Patients had clinical and transesophageal echocardiography (TEE) examinations at baseline and at 45 days following LAA closure. RESULTS: The device was successfully implanted in all patients, with no periprocedural complications. There were no episodes of bleeding, stroke, pericardial effusion, or device embolization at 45-day follow-up. No cases with residual leaks >5 mm were observed at TEE. One patient presented a device related thrombus without clinical consequences. CONCLUSIONS: This initial experience with the Ultraseal LAA closure device demonstrates preliminary safety and feasibility. Further larger studies with longer follow-up are warranted. © 2016 Wiley Periodicals, Inc.
Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Humanos , Masculino , Dados Preliminares , Desenho de Prótese , Radiografia Intervencionista , Fatores de Tempo , Resultado do TratamentoRESUMO
Transcatheter aortic valve replacement (TAVR) continued to make major strides in 2016, simultaneously expanding its application to lower risk patients as well as more technically challenging subsets of patients with aortic stenosis (AS). The two major accomplishments this year were the establishment of TAVR as the preferred treatment strategy over surgical aortic valve replacement (SAVR) in intermediate risk patients, and initial signals that TAVR and SAVR may be clinically equivalent in low-risk populations. Meanwhile, there is continued expansion of TAVR to challenging clinical subsets (bicuspid aortic valve [BAV], patients with concomitant advanced coronary artery disease [CAD], and failed surgical bioprostheses), and encouraging initial experiences with newer transcatheter heart valve systems. This paper summarizes the major research studies published on TAVR in 2016.
Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , HumanosRESUMO
PURPOSE: Although the uptake of active surveillance (AS) appears to be increasing in published series, the uptake in most geographic regions remains largely unknown. Our aim was to examine practice patterns around the use of AS in low-risk prostate cancer in Canada. In addition, we examined regional variations in AS uptake, predictors of AS uptake, and persistent use for 12 months. METHODS: This is a retrospective multicentre review of low-risk patients who underwent a prostate biopsy in 2010 in six centres in four provinces (BC, QC, MB and ON). AS was identified based on chart review and required a minimum of 6 months of follow-up after diagnosis without any active treatment. RESULTS: Of 986 patients, 781 patients (mean age 64 years) were incident cases and over three-quarters (77.3 %) chose AS at diagnosis. There were significant differences in uptake of AS by centre (range 65.0-98.0 %, p ≤ 0.05). Key multivariate predictors of pursuing AS included older age (OR 1.34, p = 0.044), centre (p = 0.021), lower number of cores (OR 1.09, p = 0.025), lower number of positive biopsy cores (OR 0.52, p < 0.001), and lower percent core involvement (OR 0.84, p < 0.001). In total, 516 (85.4 %) men remained on AS over 12 months. Maintenance with AS over 12 months differed by centre, ranging from 64.1 to 93.9 % (p = 0.001). Predictors of maintenance with AS over 12 months included older age, centre, and lower number of positive cores. CONCLUSIONS: Active surveillance is widely practiced across Canada, but important regional differences were observed. Further analyses are required to understand the root causes of differences and to determine whether AS uptake is changing over time.
Assuntos
Neoplasias da Próstata/terapia , Conduta Expectante/estatística & dados numéricos , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Biópsia com Agulha de Grande Calibre , Canadá , Gerenciamento Clínico , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Gradação de Tumores , Razão de Chances , Neoplasias da Próstata/patologia , Estudos RetrospectivosRESUMO
BACKGROUND: This study sought to evaluate the prevalence of previously undiagnosed arrhythmias in candidates for transcatheter aortic valve replacement (TAVR) and to determine the impact on therapy changes and arrhythmic events after the procedure. METHODS AND RESULTS: A total of 435 candidates for TAVR underwent 24-hour continuous ECG monitoring the day before the procedure. Newly diagnosed arrhythmias were observed in 70 patients (16.1%) before TAVR: paroxysmal atrial fibrillation (AF)/atrial tachycardia (AT) in 28, advanced atrioventricular block or severe bradycardia in 24, nonsustained ventricular tachycardia in 26, and intermittent left bundle-branch block in 3 patients. All arrhythmic events but one were asymptomatic and led to a therapy change in 43% of patients. In patients without known AF/AT, the occurrence of AF/AT during 24-hour ECG recording was associated with a higher rate of 30-day cerebrovascular events (7.1% versus 0.4%; P=0.030). Among the 53 patients with new-onset AF/AT after TAVR, 30.2% had newly diagnosed paroxysmal AF/AT before the procedure. In patients who needed permanent pacemaker implantation after the procedure (n=35), 31.4% had newly diagnosed advanced atrioventricular block or severe bradycardia before TAVR. New-onset persistent left bundle-branch block after TAVR occurred in 37 patients, 8.1% of whom had intermittent left bundle-branch block before the procedure. CONCLUSIONS: Newly diagnosed arrhythmias were observed in approximately a fifth of TAVR candidates, led to a higher rate of cerebrovascular events, and accounted for a third of arrhythmic events after the procedure. This high arrhythmia burden highlights the importance of an early diagnosis of arrhythmic events in such patients to implement the appropriate therapeutic measures earlier.
Assuntos
Estenose da Valva Aórtica/diagnóstico , Arritmias Cardíacas/diagnóstico , Efeitos Psicossociais da Doença , Eletrocardiografia Ambulatorial/tendências , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/tendências , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Arritmias Cardíacas/fisiopatologia , Compreensão , Feminino , Humanos , Masculino , Cuidados Pré-Operatórios/tendências , Resultado do TratamentoRESUMO
Transcatheter aortic valve replacement (TAVR) is an emerging technology for the management of patients with severe aortic stenosis (AS). First reported in 2002, TAVR has made remarkable progress in the past decade with completion of major randomized clinical trials, multiple observational registries, and evolution of several new devices. This article is a brief introductory overview of the TAVR procedure, devices, trials and registries, and newer developments in the field.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Seleção de Pacientes , Ensaios Clínicos Controlados Aleatórios como AssuntoRESUMO
BACKGROUND: Coexistence of moderate aortic stenosis (AS) in patients with heart failure (HF) with reduced ejection fraction is not uncommon. Moderate AS increases afterload, whereas pharmacologic reduction of afterload is a pillar of contemporary HF management. HYPOTHESIS: Unloading the left ventricle by reducing the transaortic gradient with transfemoral transcatheter aortic valve replacement (TAVR) may improve clinical outcomes in patients with moderate AS and HF with reduced ejection fraction. STUDY DESIGN: The TAVR UNLOAD (NCT02661451) is an international, multicenter, randomized, open-label, clinical trial comparing the efficacy and safety of TAVR with the Edwards SAPIEN 3 Transcatheter Heart Valve in addition to optimal heart failure therapy (OHFT) vs OHFT alone in patients with moderate AS (defined by a mean transaortic gradient ≥20 mm Hg and <40 mm Hg, and an aortic valve area >1.0 cm2 and ≤1.5 cm2 at rest or after dobutamine stress echocardiography) and reduced ejection fraction. A total of 600 patients will be randomized in a 1:1 fashion. Clinical follow-up is scheduled at 1, 6, and 12 months, and 2 years after randomization. The primary end point is the hierarchical occurrence of all-cause death, disabling stroke, hospitalizations related to HF, symptomatic aortic valve disease or nondisabling stroke, and the change in the Kansas City Cardiomyopathy Questionnaire at 1 year. Secondary end points capture effects on clinical outcome, biomarkers, echocardiographic parameters, and quality of life. SUMMARY: The TAVR UNLOAD trial aims to test the hypothesis that TAVR on top of OHFT improves clinical outcomes in patients with moderate AS and HF with reduced ejection fraction.
Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Ecocardiografia sob Estresse/métodos , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Índice de Gravidade de Doença , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodosRESUMO
BACKGROUND: Transcatheter mitral valve implantation (TMVI) for severely calcified native mitral valve disease recently emerged as a treatment option in patients deemed inoperable by conventional techniques. Yet no systematic appraisal currently exists characterizing this novel treatment paradigm. METHODS: A systematic literature review summarizing the clinical, anatomical, peri- and post-procedural characteristics underscoring the technical feasibility of this procedure was performed. RESULTS: Nine publications describing 11 patients [mean age 68 ± 10 years, 82% female, 82% severe mitral stenosis (MS), 18% severe mitral regurgitation (MR)] were identified. Mean STS score, trans-mitral gradient and effective orifice area were 10.5 ± 4.6%, 12 ± 2.4 mm Hg and 0.93 ± 0.06 cm(2) respectively. All patients had severe, circumferential mitral annular calcification on imaging. Dedicated balloon-expanding transcatheter aortic valves were used in 10/11 cases, with 8/11 cases involving a true percutaneous approach with peri-procedural 3D trans-esophageal echocardiographic guidance; 3/11 cases involved an open left atrial approach. Following initial balloon inflation and valve deployment, procedural success rate was 73%, without residual paravalvular leaks (PVL). Successful immediate re-deployment of a 2nd valve was needed in 2 instances following significant PVL detection. Residual trans-valvular gradients ranged from 3 to 7 mm Hg, with no patient demonstrating >grade 2 MR. All patients survived the procedure, with 2 reported deaths on days 10- and 41 post-TMVI being non-cardiac-related. Mid-term clinical follow-up, reported in 8 patients, revealed 6 patients to be alive at 3-months with much improved functional status. CONCLUSIONS: TMVI for native severely calcified mitral valve disease appears technically feasible with acceptable initial acute and mid-term hemodynamic and clinical outcomes. The outcomes of an ongoing, dedicated global Sapien TMVI registry will shed further light on this evolving treatment paradigm.