RESUMO
PURPOSE: To describe the use of large-diameter balloon-expandable stent-grafts (BeGraft aortic stent-graft, Bentley InnoMed GmbH, Hechingen, Germany) in the treatment of infrarenal penetrating aortic ulcer (iPAU). MATERIALS AND METHODS: Retrospective analysis of patients undergoing endovascular treatment with the BeGraft aortic stent-graft in 8 European centers from January 2017 to October 2020. Demographics, perioperative data, and midterm outcomes were collected. Endpoints of the study were technical feasibility, early mortality, and morbidity. RESULTS: A total of 40 patients were included. The mean age was 73.9±7.05 years and 63.2% were male. Indications for treatment included size and morphology (65%), presence of symptoms (29.5%), and contained ruptures (5.5%). Urgent treatment was performed in 5% of cases. Technical success was 97.5%. Median operation time was 58 minutes (19-170 minutes), with 27.5% of patients having additional procedures during the main intervention (1 additional repair with a C-TAG (W.L. Gore & Associates, Inc, Flagstaff, AZ, USA) thoracic endoprosthesis, 5 covered endovascular reconstruction of aortic bifurcation procedures, 3 extensions with proximal cuffs, and 2 percutaneous angioplasties of the common iliac arteries). Percutaneous femoral access was used in 72.5%, while groin cut-down was performed in 27.5%. Repair was successful with only 1 stent in 45% of cases, while 37.5% required 2 stents and nearly 17.5% required 3/4 stent-grafts. The 30-day mortality was 0%, with a 2.5% reintervention rate (1 patient required evacuation of an intra-abdominal hematoma). Median follow-up was 13.9 months (2-39 months), during which no vascular-related reinterventions or deaths were reported. In 4 patients, a type II endoleak was observed. No cases of graft migration, thrombosis, or stent-fracture were observed. CONCLUSIONS: The treatment of iPAU with the BeGraft aortic stent-graft in a selective patient group is feasible with low rate of perioperative morbidity and mortality. Balloon-expandable stent-grafts offer the option to repair iPAUs with a shorter coverage of the aorta using low-profile sheath, that enables treatment in the presence of calcified access vessels and small diameter aortic bifurcations.
Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Stents , Resultado do Tratamento , Úlcera/diagnóstico por imagem , Úlcera/cirurgiaRESUMO
Early graft failure after CABG surgery may lead to severe adverse events and death. Because the cause of the graft failure can vary, rapid diagnostic management is mandatory in order to address these complications appropriately. In the present 2 cases, patients who underwent CABG procedures showed typical electrocardiograms and serology of a perioperative myocardial ischemia shortly after surgery. In the first case, a rapidly performed coronary angiogram revealed a torqued right CABG, which was detorqued and, in order to avoid further torsion, fixated to the pericardium in a redo procedure. In the second case, the patient underwent a revascularization by means of percutaneous coronary intervention with stent implantation for severe stenosis due to a localized dissection of the vein graft, diagnosed on coronary angiogram. The further postoperative course of both patients was smooth and both could be discharged on day 8 and 11 after initial surgery, respectively.