Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Exp Biol ; 224(19)2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34581401

RESUMO

An unavoidable consequence of aerobic metabolism is the production of reactive oxygen species (ROS). Mitochondria have historically been considered the primary source of ROS; however, recent literature has highlighted the uncertainty in primary ROS production sites and it is unclear how variation in mitochondrial density influences ROS-induced damage and protein turnover. Fish skeletal muscle is composed of distinct, highly aerobic red muscle and anaerobic white muscle, offering an excellent model system in which to evaluate the relationship of tissue aerobic capacity and ROS-induced damage under baseline conditions. The present study used a suite of indices to better understand potential consequences of aerobic tissue capacity in red and white muscle of the pinfish, Lagodon rhomboides. Red muscle had a 7-fold greater mitochondrial volume density than white muscle, and more oxidative damage despite also having higher activity of the antioxidant enzymes superoxide dismutase and catalase. The dominant protein degradation system appears to be tissue dependent. Lysosomal degradation markers and autophagosome volume density were greater in white muscle, while ubiquitin expression and 20S proteasome activity were significantly greater in red muscle. However, ubiquitin ligase expression was significantly higher in white muscle. Red muscle had a more than 2-fold greater rate of translation and total ATP turnover than white muscle, results that may be due in part to the higher mitochondrial density and the associated increase in oxidative damage. Together, these results support the concept that an elevated aerobic capacity is associated with greater oxidative damage and higher costs of protein turnover.


Assuntos
Músculo Esquelético , Estresse Oxidativo , Trifosfato de Adenosina/metabolismo , Animais , Mitocôndrias Musculares/metabolismo , Músculo Esquelético/metabolismo , Oxirredução , Espécies Reativas de Oxigênio/metabolismo
2.
JAMA ; 326(22): 2299-2311, 2021 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-34905026

RESUMO

IMPORTANCE: Acute appendicitis is the most common abdominal surgical emergency in the world, with an annual incidence of 96.5 to 100 cases per 100 000 adults. OBSERVATIONS: The clinical diagnosis of acute appendicitis is based on history and physical, laboratory evaluation, and imaging. Classic symptoms of appendicitis include vague periumbilical pain, anorexia/nausea/intermittent vomiting, migration of pain to the right lower quadrant, and low-grade fever. The diagnosis of acute appendicitis is made in approximately 90% of patients presenting with these symptoms. Laparoscopic appendectomy remains the most common treatment. However, increasing evidence suggests that broad-spectrum antibiotics, such as piperacillin-tazobactam monotherapy or combination therapy with either cephalosporins or fluroquinolones with metronidazole, successfully treats uncomplicated acute appendicitis in approximately 70% of patients. Specific imaging findings on computed tomography (CT), such as appendiceal dilatation (appendiceal diameter ≥7 mm), or presence of appendicoliths, defined as the conglomeration of feces in the appendiceal lumen, identify patients for whom an antibiotics-first management strategy is more likely to fail. CT findings of appendicolith, mass effect, and a dilated appendix greater than 13 mm are associated with higher risk of treatment failure (≈40%) of an antibiotics-first approach. Therefore, surgical management should be recommended in patients with CT findings of appendicolith, mass effect, or a dilated appendix who are fit for surgery, defined as having relatively low risk of adverse outcomes or postoperative mortality and morbidity. In patients without high-risk CT findings, either appendectomy or antibiotics can be considered as first-line therapy. In unfit patients without these high-risk CT findings, the antibiotics-first approach is recommended, and surgery may be considered if antibiotic treatment fails. In unfit patients with high-risk CT findings, perioperative risk assessment as well as patient preferences should be considered. CONCLUSIONS AND RELEVANCE: Acute appendicitis affects 96.5 to 100 people per 100 000 adults per year worldwide. Appendectomy remains first-line therapy for acute appendicitis, but treatment with antibiotics rather than surgery is appropriate in selected patients with uncomplicated appendicitis.


Assuntos
Antibacterianos/uso terapêutico , Apendicectomia , Apendicite , Doença Aguda , Adulto , Algoritmos , Antibacterianos/efeitos adversos , Apendicectomia/efeitos adversos , Apendicite/complicações , Apendicite/diagnóstico , Apendicite/tratamento farmacológico , Apendicite/cirurgia , Humanos , Recidiva , Ruptura Espontânea , Avaliação de Sintomas , Tomografia Computadorizada por Raios X , Ultrassonografia
4.
Radiology ; 275(2): 332-42, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25906301

RESUMO

This is a review of small-bowel obstruction written primarily for residents. The review focuses on radiography and computed tomography (CT) for diagnosing small-bowel obstruction and CT for determining complications. (©) RSNA, 2015.


Assuntos
Obstrução Intestinal/diagnóstico por imagem , Intestino Delgado , Tomografia Computadorizada por Raios X , Árvores de Decisões , Humanos , Obstrução Intestinal/complicações , Obstrução Intestinal/etiologia , Intestino Delgado/irrigação sanguínea , Isquemia/complicações , Isquemia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
5.
AJR Am J Roentgenol ; 204(6): W640-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25730444

RESUMO

OBJECTIVE: The purpose of this article is to provide the reader with a comprehensive overview of dual-energy MDCT applications for imaging renal masses. CONCLUSION: Dual-energy MDCT has the potential to substantially improve the ability of radiologists to diagnose renal masses compared with conventional MDCT, potentially streamlining patients' clinical management.


Assuntos
Nefropatias/diagnóstico por imagem , Rim/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Adulto , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
Abdom Imaging ; 40(8): 3257-64, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26329977

RESUMO

OBJECTIVE: The purpose of this study is to describe our experience with the role of CT-guided percutaneous drainage of loculated intra-abdominal collections consisting entirely of gas. MATERIALS AND METHODS: An IRB-approved retrospective study analyzing patients with air-only intra-abdominal collections over an 8-year period was undertaken. Seven patients referred for percutaneous drainage were included. Size of collections, subsequent development of fluid, and microbiological yield were determined. Clinical outcome was also analyzed. RESULTS: Out of 2835 patients referred for percutaneous drainage between 2004 and 2012, seven patients (5M, 2F; average age 63, range 54-85) met criteria for inclusion with CT showing air-only collections. Percutaneous drain placement (five 8 Fr, one 10 Fr, and one 12 Fr) using Seldinger technique was performed. Four patients (57%) had recently undergone surgery (2 Whipple, 1 colectomy, 1 hepatic resection) while two (29%) had a remote surgery (1 abdominoperineal resection, 1 sigmoidectomy). Despite the lack of detectable fluid on the original CT, 6 patients (86%) had air and fluid aspirated at drainage, 5 (83%) of the aspirates developed positive microbacterial cultures. Four patients (57%) presented with fever at the time of the initial scan, all of whom had positive cultures from aspirated fluid. Four patients (57%) had leukocytosis, all of whom had positive cultures from aspirated fluid. CONCLUSIONS: Although relatively rare in occurrence, patients with air-only intra-abdominal collections with signs of infection should be considered for percutaneous management similar to that of conventional infected fluid collections. Although fluid is not visible on CT, these collections can produce fluid that contains organisms.


Assuntos
Abdome/cirurgia , Ar , Drenagem , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Catéteres , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
7.
Abdom Imaging ; 40(8): 2932-44, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26482048

RESUMO

Disease involving the pancreas can be a significant diagnostic challenge to the interpreting radiologist. Moreover, the majority of disease processes involving the pancreas carry high significant morbidity and mortality either due to their natural process or related to their treatment options. As such, it is critical for radiologists to not only provide accurate information from imaging to guide patient management, but also deliver that information in a clear manner so as to aid the referring physician. This is no better exemplified than in the case of pre-operative staging for pancreatic adenocarcinoma. Furthermore, with the changing healthcare landscape, it is now more important than ever to ensure that the value of radiology service to other providers is high. In this review, we will discuss how the radiologist can add value to the referring physician by employing novel imaging techniques in the pre-operative evaluation as well as how the information can be conveyed in the most meaningful manner through the use of structured reporting. We will also familiarize the radiologist with the imaging appearance of common complications that occur after pancreatic surgery.


Assuntos
Adenocarcinoma/diagnóstico , Imageamento por Ressonância Magnética , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico , Tomografia Computadorizada por Raios X , Meios de Contraste , Humanos , Intensificação de Imagem Radiográfica , Neoplasias Pancreáticas
8.
Radiology ; 270(2): 535-47, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24126364

RESUMO

PURPOSE: To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. MATERIALS AND METHODS: The institutional review board approved this HIPAA-compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0-16 years; weight range, 2-80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDI(vol)). The relationships between CTDI(vol)-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. RESULTS: For organs within the image coverage, CTDI(vol)-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R(2) > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%-32%) mainly because of the effect of overranging. CONCLUSION: It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDI(vol). These CTDI(vol)-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice.


Assuntos
Tomografia Computadorizada Multidetectores/métodos , Doses de Radiação , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Imageamento Tridimensional , Lactente , Recém-Nascido , Masculino , Método de Monte Carlo , Radiografia Abdominal , Radiografia Torácica , Estudos Retrospectivos
9.
Radiology ; 272(3): 767-76, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24844472

RESUMO

PURPOSE: To investigate whether dual-energy multi-detector row computed tomography (CT) with virtual monochromatic imaging can overcome renal cyst pseudoenhancement in a phantom experiment and a clinical study. MATERIALS AND METHODS: This retrospective single-center HIPAA-compliant study was approved by the institutional review board, with waiver of informed consent. Four renal compartments inserted into torso phantoms were filled with saline to simulate the unenhanced state and with iodinated solutions to simulate the three levels of renal parenchyma enhancement (140, 180, and 240 HU). Saline-filled spheres simulating renal cysts (15 and 18 mm in diameter) were serially suspended in the renal compartments and imaged with dual-energy and single-energy multi-detector row CT at four different energy levels (80, 100, 120, and 140 kVp). In addition, 28 patients (mean age, 66 years ± 10; mean body mass index, 31.3 kg/m(2) ± 6.2) with 34 intrarenal cysts were included. Virtual monochromatic images were reconstructed in 10-keV increments at energy levels ranging from 40 to 140 keV. Phantom and clinical data were analyzed by using multivariate regression analysis. RESULTS: In the phantom experiment, all polychromatic image data sets showed pseudoenhancement (postcontrast attenuation increase >10 HU) in all investigated conditions, with a significant effect on cyst size (P <.001), location (P <.001), and renal background attenuation level (P <.001). Virtual monochromatic images at energy levels ranging from 80 to 140 keV did not show pseudoenhancement, with the minimum attenuation increase (mean, 6.1 HU ± 1.6; range, 1.6-7.7 HU) on 80-keV images. In patients, pseudoenhancement never occurred on virtual monochromatic images at energy levels ranging from 90 to 140 keV. Patient body size had a significant effect (P = .007) on selection of the optimal monochromatic energy level. CONCLUSION: Dual-energy multi-detector row CT with reconstruction of virtual monochromatic images at an optimal energy level can overcome renal cyst pseudoenhancement.


Assuntos
Algoritmos , Doenças Renais Císticas/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Tomografia Computadorizada Multidetectores/instrumentação , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
10.
Korean J Radiol ; 25(6): 559-564, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38807337

RESUMO

Incidental pancreatic cystic lesions are a common challenge encountered by diagnostic radiologists. Specifically, given the prevalence of benign pancreatic cystic lesions, determining when to recommend aggressive actions such as surgical resection or endoscopic ultrasound with sampling is difficult. In this article, we review the common types of cystic pancreatic lesions including serous cystadenoma, intraductal papillary mucinous neoplasm, and mucinous cystic neoplasm with imaging examples of each. We also discuss high-risk or worrisome imaging features that warrant a referral to a surgeon or endoscopist and provid several examples of these features. These imaging features adhere to the latest guidelines from the International Consensus Guidelines, American Gastroenterological Association (2015), American College of Gastroenterology (2018), American College of Radiology (2010, 2017), and European Guidelines (2013, 2018). Our focused article addresses the imaging dilemma of managing incidental cystic pancreatic lesions, weighing the options between imaging follow-up and aggressive interventions.


Assuntos
Achados Incidentais , Cisto Pancreático , Neoplasias Pancreáticas , Humanos , Cisto Pancreático/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Diagnóstico Diferencial , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Tomografia Computadorizada por Raios X/métodos
11.
AJR Am J Roentgenol ; 201(5): W712-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24147501

RESUMO

OBJECTIVE: This article reviews the CT and MRI patterns of primary and secondary renal lymphomas and discusses the role of percutaneous biopsy in diagnosis and management. CONCLUSION: Renal lymphoma has a variable imaging spectrum and may mimic renal cell carcinoma. An awareness of the typical and atypical imaging features of both primary and secondary renal lymphomas can help the radiologist to suggest these diagnoses and recommend biopsy when appropriate.


Assuntos
Neoplasias Renais/diagnóstico , Linfoma/diagnóstico , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Diagnóstico Diferencial , Humanos , Interpretação de Imagem Assistida por Computador , Neoplasias Renais/diagnóstico por imagem , Linfoma/diagnóstico por imagem , Imagem Multimodal
12.
AJR Am J Roentgenol ; 201(6): W867-76, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24261394

RESUMO

OBJECTIVE: This article will review the multimodality imaging spectrum of medullary thyroid carcinoma (MTC) with an emphasis on anatomic and functional imaging. Recent advances in the molecular cytogenetics of this tumor and the impact on diagnosis, prognosis, and development of novel targeted therapy will be discussed. CONCLUSION: MTC is a neuroendocrine tumor with unique clinicopathologic and radiologic features compared with other thyroid malignancies. Imaging plays an important role in the optimal management of this malignancy.


Assuntos
Carcinoma Medular/diagnóstico , Diagnóstico por Imagem , Neoplasias da Glândula Tireoide/diagnóstico , Biomarcadores Tumorais/análise , Carcinoma Medular/terapia , Diagnóstico Diferencial , Humanos , Prognóstico , Neoplasias da Glândula Tireoide/terapia
13.
AJR Am J Roentgenol ; 201(3): 651-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23971460

RESUMO

OBJECTIVE: The purpose of this study was to compare CT with conventional and simulated reduced-tube current in the evaluation for acute appendicitis in children. MATERIALS AND METHODS: Validated noise-addition (tube current-reduction) software was used to create 50% and 75% tube current reductions in 60 CT examinations performed for suspected appendicitis, resulting in 180 image sets. Three blinded pediatric radiologists scored the randomized studies for the following factors: presence of the normal appendix or appendicitis (5-point scale; 1=definitely absent and 5=definitely present), presence of alternate diagnoses, and overall image quality (1=nondiagnostic and 5=excellent). Truth was defined by the interpretation of the conventional examination. RESULTS: For conventional examinations, the total number of reviews (60 cases×3 readers=180) in which the normal appendix was identified was 120 of 180 (66.7%), compared with 108 of 180 (60%) in the 50% (p=0.19) and 91 of 180 (50.6%) in the 75% (p=0.002) tube current-reduction groups. Appendicitis was identified in a total of 39 of 180 (21.7%), 38 of 180 (21.1%), and 37 of 180 (20.6%) examinations, respectively (p>0.05). This translates to sensitivities of 97% and 95% for the 50% and 75% tube current-reduction groups, respectively. Alternate diagnoses were detected in 14%, 16%, and 13% of scans, respectively. Compared with conventional-tube current examinations, reader confidence and assessment of image quality were significantly decreased for both tube current-reduction groups. CONCLUSION: Simulated tube current-reduction technology provides for systematic evaluation of diagnostic thresholds. Application of this technology in the setting of suspected appendicitis shows that tube current can be reduced by at least 50% without significantly affecting diagnostic quality, despite a decrease in reader confidence and assessment of image quality.


Assuntos
Apendicite/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Pré-Escolar , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Doses de Radiação , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos , Software
14.
Abdom Imaging ; 38(6): 1373-82, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23775388

RESUMO

Solid pseudo-papillary tumors are rare pancreatic tumors, which occur in females and are typically indolent neoplasms. However, atypical, aggressive variants can occur with locally advanced disease or metastases. They have characteristic imaging features, which vary according to size. This article provides a current update on the molecular biology, histopathology, clinico-radiological features, and management of these tumors.


Assuntos
Carcinoma Papilar/diagnóstico , Diagnóstico por Imagem , Neoplasias Pancreáticas/diagnóstico , Carcinoma Papilar/patologia , Carcinoma Papilar/terapia , Meios de Contraste , Humanos , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/terapia
15.
J Cannabis Res ; 5(1): 29, 2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37496090

RESUMO

BACKGROUND: Hemp-derived delta-9 tetrahydrocannabinol (∆9 THC) products are freely available for sale across much of the USA, but the federal legislation allowing their sale places only minimal requirements on companies. Products must contain no more than 0.3% ∆9 THC by dry weight, but no limit is placed on overall dosage and there is no requirement that products are tested. However, some states-such as Colorado-specifically prohibit products created by "chemically modifying" a natural hemp component. METHODS: Fifty-three ∆9 THC products were ordered and submitted to InfiniteCAL laboratory for analysis. The lab analysis considered potency, the presence of impurities, and whether the ∆9 THC present was natural or converted from CBD. The presence of age verification, company-conducted testing, and warning labels was also considered. RESULTS: While 96.2% of products were under the legal ∆9 THC limit, 66.0% differed from their stated dosage by more than 10%, and although 84.9% provided a lab report to customers, 71.1% of these did not check for impurities. Additionally, 49% of products converted CBD to THC to achieve their levels, and only 15.1% performed age verification at checkout. CONCLUSIONS: Despite some positive findings, the results show that hemp ∆9 THC companies offer inaccurately labeled products that contain more THC than would be allowed in adult-use states. This raises serious issues around consumer safety, and consent when consuming intoxicating products. Steps to boost accountability for companies must be considered by either the industry or lawmakers if intoxicating hemp products are to remain on the market safely.

16.
Radiology ; 262(2): 475-84, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22106356

RESUMO

PURPOSE: To retrospectively determine whether extrinsic warming of the low-osmolality contrast material iopamidol to 37°C prior to intravenous administration at computed tomography (CT) affects extravasation and allergic-like reaction rates. MATERIALS AND METHODS: The need to obtain informed patient consent was waived for this HIPAA-compliant and institutional review board-approved analysis. All adverse events related to the intravenous administration of iopamidol during CT examinations occurring 200 days before (period 1) and 200 days after (period 2) the cessation of extrinsic contrast material warming (37°C) for intravenous injections of less than 6 mL/sec at Duke University Medical Center (Durham, NC) were retrospectively reviewed. Adverse event rates were compared by using χ2 statistics. RESULTS: There were 12,682 injections during period 1 (10,831 injections of iopamidol 300 and 1851 injections of iopamidol 370) and 12,138 injections (10, 064 injections of iopamidol 300 and 2074 injections of iopamidol 370) during period 2. Adverse event rates for iopamidol 300 were not affected by extrinsic warming (extravasation rates: 0.30% [32 of 10,831] in period 1 vs 0.23% [23 of 10,064] in period 2, P=.64; allergic-like reaction rates: 0.39% [42 of 10,831] in period 1 vs 0.46% [46 of 10,064] in period 2, P=.74; overall adverse events: 0.68% [74 of 10,831] in period 1 vs 0.69% [69 of 10,064] in period 2, P=.99). Discontinuation of extrinsic warming was associated with significantly increased extravasation and overall adverse event rates for iopamidol 370 (extravasation rates: 0.27% [five of 1851] vs 0.87% [18 of 2074], P=.05; allergic-like reaction rates: 0.16% [three of 1851] vs 0.39% [eight of 2074], P=.42; overall adverse events: 0.43% [eight of 1851] vs 1.25% [26 of 2074], P=.02). CONCLUSION: Extrinsic warming (to 37°C) does not appear to affect adverse event rates for intravenous injections of iopamidol 300 of less than 6 mL/sec but is associated with a significant reduction in extravasation and overall adverse event rates for the more viscous iopamidol 370.


Assuntos
Hipersensibilidade a Drogas/epidemiologia , Hipersensibilidade a Drogas/prevenção & controle , Extravasamento de Materiais Terapêuticos e Diagnósticos/epidemiologia , Extravasamento de Materiais Terapêuticos e Diagnósticos/prevenção & controle , Iodo , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adolescente , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Meios de Contraste , Feminino , Temperatura Alta , Humanos , Lactente , Masculino , Michigan/epidemiologia , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Fatores de Risco , Gestão de Riscos , Adulto Jovem
17.
Med Phys ; 39(11): 6550-71, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23127050

RESUMO

PURPOSE: In computed tomography (CT), organ dose, effective dose, and risk index can be estimated from volume-weighted CT dose index (CTDI(vol)) or dose-length product (DLP) using conversion coefficients. Studies have investigated how these coefficients vary across scanner models, scan parameters, and patient size. However, their variability across CT protocols has not been systematically studied. Furthermore, earlier studies of the effect of patient size have not included obese individuals, which currently represent more than one-third of U.S. adults. The purpose of this study was to assess the effects of protocol and obesity on dose and risk conversion coefficients in adult body CT. METHODS: Whole-body computational phantoms were created from clinical CT images of six adult patients (three males, three females), representing normal-weight patients and patients of three obesity classes. Body CT protocols at our institution were selected and categorized into ten examination categories based on anatomical region examined. A validated Monte Carlo program was used to estimate organ dose. Organ dose estimates were normalized by CTDI(vol) and size-specific dose estimate (SSDE) to obtain organ dose conversion coefficients (denoted as h and h(ss) factors, respectively). Assuming each phantom to be 20, 40, and 60 years old, effective dose and risk index were calculated and normalized by DLP to obtain effective dose and risk index conversion coefficients (denoted as k and q factors, respectively). Coefficient of variation was used to quantify the variability of each conversion coefficient across examination categories. The effect of obesity was assessed by comparing each obese phantom with the normal-weight phantom of the same gender. RESULTS: For a given organ, the variability of h factor across examination categories that encompassed the entire organ volume was generally within 15%. However, k factor varied more across examination categories (15%-27%). For all three ages, the variability of q factor was small for male (<10%), but large for female phantoms (21%-43%). Relative to the normal-weight phantoms, the reduction in h factor (an average across fully encompassed organs) was 17%-42%, 17%-40%, and 51%-63% for obese-class-I, obese-class-II, and obese-class-III phantoms, respectively. h(ss) factor was not independent of patient diameter and generally decreased with increasing obesity. Relative to the normal-weight phantoms, the reduction in k factor was 12%-40%, 14%-46%, and 44%-59% for obese-class-I, obese-class-II, and obese-class-III phantoms, respectively. The respective reduction in q factor was 11%-36%, 17%-42%, and 48%-59% at 20 years of age and similar at other ages. CONCLUSIONS: In adult body CT, dose to an organ fully encompassed by the primary radiation beam can be estimated from CTDI(vol) using a protocol-independent conversion coefficient. However, fully encompassed organs only account for 50% ± 19% of k factor and 46% ± 24% of q factor. Dose received by partially encompassed organs is also substantial. To estimate effective dose and risk index from DLP, it is necessary to use conversion coefficients specific to the anatomical region examined. Obesity has a significant effect on dose and risk conversion coefficients, which cannot be predicted using body diameter alone. SSDE-normalized organ dose is not independent of diameter. SSDE itself generally overestimates organ dose for obese patients.


Assuntos
Obesidade , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Neoplasias Induzidas por Radiação/etiologia , Imagens de Fantasmas , Radiometria , Risco , Tomografia Computadorizada por Raios X/efeitos adversos , Irradiação Corporal Total
18.
AJR Am J Roentgenol ; 198(4): 840-5, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22451549

RESUMO

OBJECTIVE: The purpose of our study was to investigate whether virtual unenhanced adrenal nodule attenuation values can replace true noncontrast attenuation values. MATERIALS AND METHODS: Twenty-three incidentally discovered adrenal nodules (19 adenomas and four metastases) were identified in 19 patients (11 men and eight women; mean age, 65 years; age range, 38-84 years) who underwent unenhanced single-energy CT followed by contrast-enhanced dual-energy CT on the same scanner. A virtual unenhanced imaging dataset was generated from each dual-energy CT dataset. CT attenuation of each adrenal nodule was measured at the same location on virtual unenhanced images and true unenhanced images by three radiologists and mean values compared using the Student t test. Correlation between virtual unenhanced and true unenhanced values was determined using linear regression analysis. The mean difference and percentage of diagnostic agreement were also determined. Interreader variability was assessed using the intraclass correlation coefficient (ICC). RESULTS: The mean ± SD attenuation values for virtual unenhanced images and true unenhanced images were 14.7 ± 15.1 HU and 12.9 ± 13.4 HU, respectively (p = 0.2). Strong positive correlation was observed between virtual unenhanced images and true unenhanced images (R = 0.83-0.87). The mean difference between virtual unenhanced images and true unenhanced images was 1.8 ± 1.7 HU. Diagnostic agreement between virtual unenhanced images and true unenhanced images was 83-91% for three radiologists. No malignant nodules were misclassified as benign on virtual unenhanced images. The ICC was 0.88 and 0.96 for virtual unenhanced images and true unenhanced images, respectively, indicating high interreader agreement. CONCLUSION: Virtual unenhanced and true unenhanced attenuation measurements of adrenal nodules were not significantly different and showed strongly positive linear correlation. This finding resulted in substantial diagnostic agreement between virtual unenhanced images and true unenhanced images for distinguishing benign from malignant nodules.


Assuntos
Doenças das Glândulas Suprarrenais/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Achados Incidentais , Iopamidol , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Técnica de Subtração
19.
Ann Vasc Surg ; 26(5): 685-92, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22305864

RESUMO

BACKGROUND: Once thought to have unresectable disease, pancreatic cancer patients with portal venous involvement are now reported to have comparable survival after pancreaticoduodenectomy (PD) with vascular reconstruction (VR) as compared with patients without vascular involvement. We hypothesize that a multidisciplinary approach involving a vascular surgeon will minimize morbidity and improve patency of VRs. METHODS: We identified 204 patients who underwent PD for pancreatic adenocarcinoma from 1997 to 2008. Patients who underwent PD with VR (N = 42) were compared with those who underwent standard PD (N = 162). VRs were performed by a vascular surgeon and involved primary repair (N = 8), vein patch (N = 25), or interposition grafting (N = 9) with femoral or other venous conduit. RESULTS: Patients undergoing PD with VR had larger tumors (3.0 cm vs. 2.5 cm, P < 0.01) but did not have different rates of tumor-free margins (73% vs. 72%, P = 0.84) or lymph nodes metastases (50% vs. 38%, P = 0.14). The VR group had higher median blood loss (875 mL vs. 550 mL, P = 0<0.01), but no differences in mortality, complication rates, length of stay, or readmission rates were found in a median follow-up of 29 months. Overall survival rates were similar. Predictors of mortality on multivariate analysis included increasing histological grade (P = 0.01), positive lymph nodes (P = 0.01), and increasing tumor size (P = 0.01), but not VR (P = 0.28). When evaluated by computed tomography scans within 6 months postoperatively, 97% of reconstructions remained patent. CONCLUSIONS: The need for VR is not a contraindication to potentially curative resection in patients with pancreatic adenocarcinoma. Assistance of a vascular surgeon during VR may allow moderate-volume centers to achieve outcomes comparable with high-volume centers.


Assuntos
Adenocarcinoma/cirurgia , Comportamento Cooperativo , Neoplasias Pancreáticas/cirurgia , Pancreaticoduodenectomia , Equipe de Assistência ao Paciente , Procedimentos de Cirurgia Plástica , Veia Porta/cirurgia , Procedimentos Cirúrgicos Vasculares , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/mortalidade , Adenocarcinoma/secundário , Adulto , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Invasividade Neoplásica , North Carolina , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/mortalidade , Neoplasias Pancreáticas/patologia , Pancreaticoduodenectomia/efeitos adversos , Pancreaticoduodenectomia/mortalidade , Seleção de Pacientes , Veia Porta/diagnóstico por imagem , Veia Porta/patologia , Modelos de Riscos Proporcionais , Procedimentos de Cirurgia Plástica/efeitos adversos , Procedimentos de Cirurgia Plástica/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade
20.
Radiology ; 259(1): 173-83, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21292866

RESUMO

PURPOSE: To determine whether dual-energy multidetector CT enables detection of renal lesion enhancement by using calculated nonenhanced images with spectral-based extraction in a non-body weight-restricted patient population. MATERIALS AND METHODS: Between January 2008 and December 2009, 139 patients were enrolled in this prospective HIPAA-compliant, institutional review board-approved study. Written informed consent was obtained from all patients. After single-energy nonenhanced 120-kVp CT images were acquired, contrast material-enhanced dual-energy multidetector CT images were acquired at 80 and 140 kVp. Calculated nonenhanced images were generated by using spectral-based iodine extraction. Lesion attenuation was measured on the acquired nonenhanced, calculated nonenhanced, and 140-kVp contrast-enhanced nephrographic images. Enhancement, defined as a 15-HU or greater increase in attenuation on the nephrographic images, was assessed by using the baseline attenuation on the acquired and calculated nonenhanced images. Acquired nonenhanced versus calculated nonenhanced image attenuation, as well as enhancement values, were compared by using paired Student t tests and Bland-Altman plots. RESULTS: Hypoattenuating (n = 66) and hyperattenuating (n = 28) cysts, angiomyolipomas (n = 18), and solid enhancing lesions (n = 27) were detected. Mean attenuation values for hypoattenuating cysts on the acquired and calculated nonenhanced CT images were 6.5 HU ± 5.8 (standard deviation) and 8.1 HU ± 3.1 (P = .13), respectively, with corresponding enhancement values of 1.1 HU ± 5.2 and -0.5 HU ± 6.2 (P = .12), respectively. Mean values for hyperattenuating cysts were 29.4 HU ± 5.6 on acquired images and 31.7 HU ± 5.1 on calculated images (P = .39) (corresponding enhancement, 4.7 HU ± 3.3 and 2.3 HU ± 4.1, respectively; P = .09). Mean values for fat-containing enhancing lesions were -90.6 HU ± 24.7 on acquired images and -85.9 HU ± 23.7 on calculated images (P = .57) (corresponding enhancement, 18.2 HU ± 10.1 and 13.6 HU ± 10.7, respectively; P = .19). Mean attenuation values for solid enhancing lesions were 26.0 HU ± 15.0 on acquired images and 27.7 HU ± 14.9 on calculated images (P = .45) (corresponding enhancement, 60.3 HU ± 13.1 and 58.3 HU ± 15.5, respectively; P = .38). CONCLUSION: Dual-energy CT acquisitions with spectral-based postprocessing enabled accurate detection of renal lesion enhancement across the attenuation spectrum of frequently encountered renal lesions in a non-body habitus-restricted patient population.


Assuntos
Iopamidol , Doenças Renais Císticas/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA