Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Small Methods ; : e2300923, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693090

RESUMO

A novel optically induced dielectrophoresis (ODEP) system that can operate under flow conditions is designed for automatic trapping of cells and subsequent induction of 2D multi-frequency cell trajectories. Like in a "ping-pong" match, two virtual electrode barriers operate in an alternate mode with varying frequencies of the input voltage. The so-derived cell motions are characterized via time-lapse microscopy, cell tracking, and state-of-the-art machine learning algorithms, like the wavelet scattering transform (WST). As a cell-electrokinetic fingerprint, the dynamic of variation of the cell displacements happening, over time, is quantified in response to different frequency values of the induced electric field. When tested on two biological scenarios in the cancer domain, the proposed approach discriminates cellular dielectric phenotypes obtained, respectively, at different early phases of drug-induced apoptosis in prostate cancer (PC3) cells and for differential expression of the lectine-like oxidized low-density lipoprotein receptor-1 (LOX-1) transcript levels in human colorectal adenocarcinoma (DLD-1) cells. The results demonstrate increased discrimination of the proposed system and pose an additional basis for making ODEP-based assays addressing cancer heterogeneity for precision medicine and pharmacological research.

2.
Nanotechnology ; 21(25): 255601, 2010 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-20508312

RESUMO

High densities of self-catalyzed Si nanowires have been grown at temperatures down to 320 degrees C on different Si substrates, whose surfaces have been roughened by simple physical or chemical treatments. The particular substrates are Si(110) cleavage planes, chemically etched Si(111) surfaces and microcrystalline Si obtained by laser annealing thin amorphous Si layers. The NW morphology depends on the growth surface. Transmission electron microscopy indicates that the NWs are made of pure Si with a crystalline core structure. Reflectivity measurements confirm this latter finding.

3.
Sci Rep ; 10(1): 12556, 2020 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-32724098

RESUMO

Colloidal quantum dots (CQDs) have been recently investigated as promising building blocks for low-cost and high-performance gas sensors due to their large effective surface-to-volume ratio and their suitability for versatile functionalization through surface chemistry. In this work we report on lead sulphide CQDs based sensors for room temperature NO2 detection. The sensor response has been measured for different pollutant gases including NO2, CH4, CO and CO2 and for different concentrations in the 2.8-100 ppm range. For the first time, the influence of the QDs film thickness on the sensor response has been investigated and optimized. Upon 30 ppm NO2 release, the best room temperature gas response is about 14 Ω/Ω, with response and recovery time of 12 s and 26 min, respectively. A detection limit of about 0.15 ppb was estimated from the slope of the sensor response and its electric noise. The gas sensors exhibit high sensitivity to NO2, remarkable selectivity, repeatability and full recovery after exposure.

4.
Materials (Basel) ; 12(20)2019 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-31618862

RESUMO

This work describes the development of a new method for ion implantation induced crystal damage recovery using multiple XeCl (308 nm) laser pulses with a duration of 30 ns. Experimental activity was carried on single phosphorus (P) as well as double phosphorus and aluminum (Al) implanted 4H-SiC epitaxial layers. Samples were then characterized through micro-Raman spectroscopy, Photoluminescence (PL) and Transmission Electron Microscopy (TEM) and results were compared with those coming from P implanted thermally annealed samples at 1650-1700-1750 °C for 1 h as well as P and Al implanted samples annealed at 1650 °C for 30 min. The activity outcome shows that laser annealing allows to achieve full crystal recovery in the energy density range between 0.50 and 0.60 J/cm2. Moreover, laser treated crystal shows an almost stress-free lattice with respect to thermally annealed samples that are characterized by high point and extended defects concentration. Laser annealing process, instead, allows to strongly reduce carbon vacancy (VC) concentration in the implanted area and to avoid intra-bandgap carrier recombination centres. Implanted area was almost preserved, except for some surface oxidation processes due to oxygen leakage inside the testing chamber. However, the results of this experimental activity gives way to laser annealing process viability for damage recovery and dopant activation inside the implanted area.

5.
Sci Rep ; 8(1): 16717, 2018 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-30425252

RESUMO

The understanding of brain processing requires monitoring and exogenous modulation of neuronal ensembles. To this end, it is critical to implement equipment that ideally provides highly accurate, low latency recording and stimulation capabilities, that is functional for different experimental preparations and that is highly compact and mobile. To address these requirements, we designed a small ultra-flexible multielectrode array and combined it with an ultra-compact electronic system. The device consists of a polyimide microelectrode array (8 µm thick and with electrodes measuring as low as 10 µm in diameter) connected to a miniaturized electronic board capable of amplifying, filtering and digitalizing neural signals and, in addition, of stimulating brain tissue. To evaluate the system, we recorded slow oscillations generated in the cerebral cortex network both from in vitro slices and from in vivo anesthetized animals, and we modulated the oscillatory pattern by means of electrical and visual stimulation. Finally, we established a preliminary closed-loop algorithm in vitro that exploits the low latency of the electronics (<0.5 ms), thus allowing monitoring and modulating emergent cortical activity in real time to a desired target oscillatory frequency.


Assuntos
Encéfalo/fisiologia , Estimulação Elétrica , Eletrofisiologia/instrumentação , Encéfalo/citologia , Cinética , Microeletrodos , Software
6.
Dent Mater J ; 37(5): 835-842, 2018 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-29998941

RESUMO

Aim of this in vitro study was to analyze structural properties of two different polymeric orthodontic aligners, Exceed30 (EX30) and Smart Track (LD30), before and after use. Forty patterns of aligners were randomly selected: 20 LD30 and 20 EX30, worn intra-orally for 14±3 days, 22 h/day. From each aligner, 10 specimens were prepared from buccal surfaces of the incisor region by the cutting of samples 5×5 mm under a stereomicroscope. All samples were subjected to Fourier transform infrared spectroscopy, micro-Raman spectroscopy, X-ray diffraction, tensile and indentation strength test. LD30 appeared more homogeneous, with a crystalline fraction lower than EX30 and exhibited a higher elastic behavior and a lower tendency to warp after use than EX30. LD30 demonstrated better adaptability to the dental arch and greater consistency of application of orthodontic forces than produced with EX30. However, both materials showed structural modifications that resulted in increased sample hardness and hyper-plasticity.


Assuntos
Desenho de Aparelho Ortodôntico , Aparelhos Ortodônticos Removíveis , Elasticidade , Dureza , Humanos , Técnicas In Vitro , Teste de Materiais , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral Raman , Propriedades de Superfície , Resistência à Tração , Difração de Raios X
7.
Adv Healthc Mater ; 5(5): 575-83, 2016 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-26717420

RESUMO

The direct integration of disordered arranged and randomly oriented silicon nanowires (SiNWs) into ultraflexible and transferable electronic circuits for electrochemical biosensing applications is proposed. The working electrode (WE) of a three-electrode impedance device, fabricated on a polyimide (PI) film, is modified with SiNWs covered by a thin Au layer and functionalized to bind the sensing element. The biosensing behavior is investigated through the ligand-receptor binding of biotin-avidin system. Impedance measurements show a very efficient detection of the avidin over a broad range of concentrations from hundreds of micromolar down to the picomolar values. The impedance response is modeled through a simple equivalent circuit, which takes into account the unique WE morphology and its modification with successive layers of biomolecules. This approach of exploiting highly disordered SiNW ensemble in biosensing proves to be very promising for the following three main reasons: first, the system morphology allows high sensing performance; second, these nanostructures can be built via scalable and transferable fabrication methodology allowing an easy integration on non-conventional substrates; third, reliable modeling of the sensing response can be developed by considering the morphological and surface characteristics over an ensemble of disordered NWs rather than over individual NWs.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Nanofios/química , Silício/química , Impedância Elétrica , Eletrodos , Ouro/química , Nanofios/ultraestrutura
8.
IEEE Trans Neural Syst Rehabil Eng ; 23(3): 342-50, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25073174

RESUMO

Electrocorticography (ECoG) is becoming a common tool for clinical applications, such as preparing patients for epilepsy surgery or localizing tumor boundaries, as it successfully balances invasiveness and information quality. Clinical ECoG arrays use millimeter-scale electrodes and centimeter-scale pitch and cannot precisely map neural activity. Higher-resolution electrodes are of interest for both current clinical applications, providing access to more precise neural activity localization and novel applications, such as neural prosthetics, where current information density and spatial resolution is insufficient to suitably decode signals for a chronic brain-machine interface. Developing such electrodes is not trivial because their small contact area increases the electrode impedance, which seriously affects the signal-to-noise ratio, and adhering such an electrode to the brain surface becomes critical. The most straightforward approach requires increasing the array conformability with flexible substrates while improving the electrode performance using materials with superior electrochemical properties. In this paper, we propose an ultra-flexible and conformable polyimide-based micro-ECoG array of submillimeter recording sites electrochemically coated with high surface area conductive polymer-carbon nanotube composites to improve their brain-electrical coupling capabilities. We characterized our devices both electrochemically and by recording from rat somatosensory cortex in vivo. The performance of the coated and uncoated electrodes was directly compared by simultaneously recording the same neuronal activity during multiwhisker deflection stimulation. Finally, we assessed the effect of electrode size on the extraction of somatosensory evoked potentials and found that in contrast to the normal high-impedance microelectrodes, the recording capabilities of our low-impedance microelectrodes improved upon reducing their size from 0.2 to 0.1 mm.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Eletroencefalografia/instrumentação , Nanotubos de Carbono , Polímeros , Animais , Encéfalo/fisiologia , Mapeamento Encefálico , Interfaces Cérebro-Computador , Impedância Elétrica , Técnicas Eletroquímicas , Eletrodos , Fenômenos Eletrofisiológicos , Potenciais Somatossensoriais Evocados , Masculino , Microeletrodos , Estimulação Física , Ratos , Ratos Long-Evans , Razão Sinal-Ruído , Vibrissas/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA