Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Kidney Int ; 105(2): 338-346, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37918791

RESUMO

Precise determination of circulating parathyroid hormone (PTH) concentration is crucial to diagnose and manage various disease conditions, including the chronic kidney disease-mineral and bone disorder. However, the lack of standardization in PTH assays is challenging for clinicians, potentially leading to medical errors because the different assays do not provide equivalent results and use different reference ranges. Here, we aimed to evaluate the impact of recalibrating PTH immunoassays by means of a recently developed LC-MS/MS method as the reference. Utilizing a large panel of pooled plasma samples with PTH concentrations determined by the LC-MS/MS method calibrated with the World Health Organization (WHO) 95/646 International Standard, five PTH immunoassays were recalibrated. The robustness of this standardization was evaluated over time using different sets of samples. The recalibration successfully reduced inter-assay variability with harmonization of PTH measurements across different assays. By recalibrating the assays based on the WHO 95/646 International Standard, we demonstrated the feasibility for standardizing PTH measurement results and adopting common reference ranges for PTH assays, facilitating a more consistent interpretation of PTH values. The recalibration process aligns PTH results obtained from various immunoassays with the LC-MS/MS method, providing more consistent and reliable measurements. Thus, establishing true standardization across all PTH assays is crucial to ensure consistent interpretation and clinical decision-making.


Assuntos
Distúrbio Mineral e Ósseo na Doença Renal Crônica , Insuficiência Renal Crônica , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem , Hormônio Paratireóideo , Insuficiência Renal Crônica/diagnóstico
2.
Clin Chem Lab Med ; 61(10): 1700-1707, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37128992

RESUMO

Immunocapture is now a well-established method for sample preparation prior to quantitation of peptides and proteins in complex matrices. This short review will give an overview of some clinical applications of immunocapture methods, as well as protocols with and without enzymatic digestion in a clinical context. The advantages and limitations of both approaches are discussed in detail. Challenges related to the choice of mass spectrometer are also discussed. Top-down, middle-down, and bottom-up approaches are discussed. Even though immunocapture has its limitations, its main advantage is that it provides an additional dimension of separation and/or isolation when working with peptides and proteins. Overall, this short review demonstrates the potential of such techniques in the field of proteomics-based clinical medicine and paves the way for better personalized medicine.


Assuntos
Peptídeos , Proteínas , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas , Proteínas/análise
3.
Clin Chem Lab Med ; 61(9): 1561-1566, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-36995129

RESUMO

OBJECTIVES: The exploration of the metabolites in the degradation pathways of vitamin D (VTD) has gained importance in recent years and simultaneous quantitation of twenty-five-hydroxy vitamin D (25(OH)D) mass concentration together with 24,25-dihydroxyvitamin D (24,25(OH)2D) has been proposed as a newer approach to define VTD deficiency. Yet, no data are available on 24,25(OH)2D biological variation (BV). In this study, we evaluated 24,25(OH)2D's BV on the European Biological Variation Study (EuBIVAS) cohort samples to determine if analytical performance specifications (APS) for 24,25(OH)2D could be generated. METHODS: Six European laboratories recruited 91 healthy participants. 25(OH)D and 24,25(OH)2D concentrations in K3-EDTA plasma were examined weekly for up to 10 weeks in duplicate with a validated LC-MS/MS method. The Vitamin D Metabolite Ratio (24,25(OH)2D divided by 25(OH)D × 100) was also calculated at each time point. RESULTS: Linear regression of the mean 24,25(OH)2D concentrations at each blood collection showed participants were not in steady state. Variations of 24,25(OH)2D over time were significantly positively associated with the slopes of 25(OH)D concentrations over time and the concentration of 25(OH)D of the participant at inclusion, and negatively associated with body mass index (BMI), but not with age, gender, or location of the participant. The variation of the 24,25(OH)2D concentration in participants over a 10 weeks period was 34.6%. Methods that would detect a significant change linked to the natural production of 24,25(OH)2D over this period at p<0.05 would need a relative measurement uncertainty (u%)<14.9% while at p<0.01, relative measurement uncertainty should be <10.5%. CONCLUSIONS: We have defined for the first time APS for 24,25(OH)2D examinations. According to the growing interest in this metabolite, several laboratories and manufacturers might aim to develop specific methods for its determination. The results presented in this paper are thus necessary prerequisites for the validation of such methods.


Assuntos
Espectrometria de Massas em Tandem , Deficiência de Vitamina D , Humanos , Cromatografia Líquida/métodos , Incerteza , Espectrometria de Massas em Tandem/métodos , Vitamina D , Deficiência de Vitamina D/diagnóstico , Vitaminas
4.
Clin Lab ; 69(3)2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36912296

RESUMO

BACKGROUND: D4-androstenedione (D4ASD) is an intermediate hormone of androgen biosynthesis by the gonads and the adrenal glands. The interest in D4ASD concentration assessment resides in diagnostics of androgenic hyperproduction pathologies. Currently, many D4ASD quantification methods are available on the market including immunological methods that remain problematic due to the possible cross-reactivity with endogenous or exogenous steroids. METHODS: Recently Roche® launched a new fully automated instrument for the measurement of D4ASD concentration. In this paper, the criteria of analytical performance (repeatability and intermediate precision) of the D4ASD Roche® assay were assessed and compared with 2 different methods including a radioimmunoassay (RIA) as well as a liquid chromatography tandem mass spectrometry (LC-MS/MS) method. RESULTS: Repeatability and intermediate precision of the D4ASD Roche® were acceptable according to the prede-fined RICOS standard (CV ≤ 7.9%) and the assay showed a good correlation with other assays considering the 95% CI obtained for the slope and the y-intercept. CONCLUSIONS: This method demonstrates acceptable criteria of analytical performance with an intermediate imprecision and a trueness within the fixed acceptance limits.


Assuntos
Androstenodiona , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Radioimunoensaio/métodos , Esteroides
5.
Clin Chem Lab Med ; 60(1): 74-81, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-34727586

RESUMO

OBJECTIVES: In-house developed liquid-chromatography mass spectrometry (LC-MS/MS) methods are used more and more frequently for the simultaneous quantification of vitamin D metabolites. Among these, 24,25-dihydroxyvitamin D3 (24,25(OH)2D3) is of clinical interest. This study assessed the agreement of this metabolite in two validated in-house LC-MS/MS methods. METHODS: 24,25(OH)2D3 was measured in 20 samples from the vitamin D external quality assurance (DEQAS) program and in a mixed cohort of hospital patients samples (n=195) with the LC-MS/MS method at the Medical University of Graz (LC-MS/MS 1) and at the University of Liège (LC-MS/MS 2). RESULTS: In DEQAS samples, 24,25(OH)2D3 results with LC-MS/MS 1 had a proportional bias of 1.0% and a negative systemic difference of -0.05%. LC-MS/MS 2 also showed a proportional bias of 1.0% and the negative systemic bias was -0.22%. Comparing the EQA samples with both methods, no systemic bias was found (0.0%) and the slope was 1%. The mean difference of 195 serum sample measurements between the two LC-MS/MS methods was minimal (-0.2%). Both LC-MS/MS methods showed a constant bias of 0.31 nmol/L and a positive proportional bias of 0.90%, respectively. CONCLUSIONS: This study is the first to assess the comparability of 24,25(OH)2D3 concentrations in a mixed cohort of hospitalized patients with two fully validated in-house LC-MS/MS methods. Despite different sample preparation, chromatographic separation and ionization, both methods showed high precision measurements of 24,25(OH)2D3. Furthermore, we demonstrate the improvement of accuracy and precision measurements of 24,25(OH)2D3 in serum samples and in the DEQAS program.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , 24,25-Di-Hidroxivitamina D 3 , Cromatografia Líquida/métodos , Humanos , Manejo de Espécimes , Espectrometria de Massas em Tandem/métodos
6.
Acta Oncol ; 60(5): 567-574, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33295823

RESUMO

BACKGROUND AND PURPOSE: Reducing breathing motion in radiotherapy (RT) is an attractive strategy to reduce margins and better spare normal tissues. The objective of this prospective study (NCT03729661) was to investigate the feasibility of irradiation of non-small cell lung cancer (NSCLC) with visually guided moderate deep inspiration breath-hold (IBH) using nasal high-flow therapy (NHFT). MATERIAL AND METHODS: Locally advanced NSCLC patients undergoing photon RT were given NHFT with heated humidified air (flow: 40 L/min with 80% oxygen) through a nasal cannula. IBH was monitored by optical surface tracking (OST) with visual feedback. At a training session, patients had to hold their breath as long as possible, without and with NHFT. For the daily cone beam CT (CBCT) and RT treatment in IBH, patients were instructed to keep their BH as long as it felt comfortable. OST was used to analyze stability and reproducibility of the BH, and CBCT to analyze daily tumor position. Subjective tolerance was measured with a questionnaire at 3 time points. RESULTS: Of 10 included patients, 9 were treated with RT. Seven (78%) completed the treatment with NHFT as planned. At the training session, the mean BH length without NHFT was 39 s (range 15-86 s), and with NHFT 78 s (range 29-223 s) (p = .005). NHFT prolonged the BH duration by a mean factor of 2.1 (range 1.1-3.9s). The mean overall stability and reproducibility were within 1 mm. Subjective tolerance was very good with the majority of patients having no or minor discomfort caused by the devices. The mean inter-fraction tumor position variability was 1.8 mm (-1.1-8.1 mm;SD 2.4 mm). CONCLUSION: NHFT for RT treatment of NSCLC in BH is feasible, well tolerated and significantly increases the breath-hold duration. Visually guided BH with OST is stable and reproducible. We therefore consider this an attractive patient-friendly approach to treat lung cancer patients with RT in BH.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Suspensão da Respiração , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Humanos , Neoplasias Pulmonares/radioterapia , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes
7.
Clin Chem Lab Med ; 58(2): 197-201, 2020 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-31804956

RESUMO

Background Simultaneous measurement of 25(OH)D and 24,25(OH)2D is a new tool for predicting vitamin D deficiency and allows evaluating CYP24A1 lack of function. Interpretation of 24,25(OH)2D should be performed according to 25(OH)D levels and a ratio, called the vitamin D metabolite ratio (VMR) has been proposed for such a purpose. Unfortunately, the VMR can be expressed in different ways and cannot be used if 24,25(OH)2D concentrations are undetectable. Here, we propose evaluating the enzyme activity taking into consideration the probability that a normal population presents undetectable 24,25(OH)2D concentrations according to 25(OH)D levels. We thus retrospectively measured 25(OH)D and 24,25(OH)2D in a population of 1200 young subjects to evaluate the 25(OH)D threshold above which the enzyme was induced. Methods Serum samples from 1200 infants, children, adolescent and young adults were used to simultaneously quantify 25(OH)D and 24,25(OH)2D by LCMS/MS. Results Median (interquartile range [IQR]) levels were 20.6 (14.4-27.2) ng/mL for 25(OH)D. 172 subjects (14.3%) presented 24,25(OH)2D values below the LOQ. When 25(OH)D values were <11 ng/mL, 63.1% of subjects presented undetectable 24,25(OH)2D concentrations. Percentage decreased with increasing 25(OH)D values to become 19.7% for 25(OH)D comprised between 12 and 15 ng/mL, 5.1% for 25(OH)D between 16 and 20 and 0.7% for 25(OH)D >21 ng/mL. Conclusions We suggest using a statistical approach to evaluate CYP24A1 function according to 25(OH)D concentrations. Our results also show that vitamin D deficiency, as defined biochemically, could be around 20 ng/mL in infants, children, adolescent and young adults and that vitamin D deficiency could be evaluated on a more individual basis.


Assuntos
24,25-Di-Hidroxivitamina D 3/análise , Calcifediol/análise , Deficiência de Vitamina D/patologia , Vitamina D3 24-Hidroxilase/genética , Adolescente , Criança , Pré-Escolar , Cromatografia Líquida de Alta Pressão , Feminino , Humanos , Lactente , Limite de Detecção , Masculino , Polimorfismo de Nucleotídeo Único , Estudos Retrospectivos , Espectrometria de Massas em Tandem , Deficiência de Vitamina D/genética , Adulto Jovem
8.
Clin Chem Lab Med ; 58(6): 1002-1009, 2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-32069223

RESUMO

Historically, the determination of low concentration analytes was initially made possible by the development of rapid and easy-to-perform immunoassays (IAs). Unfortunately, typical problems inherent to IA technologies rapidly appeared (e.g. elevated cost, cross-reactivity, lot-to-lot variability, etc.). In turn, liquid chromatography tandem mass spectrometry (LC-MS/MS) methods are sensitive and specific enough for such analyses. Therefore, they would seem to be the most promising candidates to replace IAs. There are two main choices when implementing a new LC-MS/MS method in a clinical laboratory: (1) Developing an in-house method or (2) purchasing ready-to-use kits. In this paper, we discuss some of the respective advantages, disadvantages and mandatory requirements of each choice. Additionally, we also share our experiences when developing an in-house method for cortisol determination and the implementation of an "ready-to-use" (RTU) kit for steroids analysis.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Humanos , Limite de Detecção
9.
Acta Oncol ; 56(4): 541-547, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28358665

RESUMO

PURPOSE: It is unknown whether the dose-response relation of the primary tumor in NSCLC is different from that of the involved lymph nodes (LN). As the recurrence rate is much lower in LN, we hypothesized that LN need a lower radiation dose. MATERIAL AND METHODS: A retrospective analysis of prospective data was performed on patients with locally advanced NSCLC treated with (chemo)radiotherapy. The impact of EQD2,T prescription dose on relapse was analyzed using Cox regression modeling correcting for baseline diameter. RESULTS: From 2006 to 2010, 75 consecutive patients were included, resulting in 142 lymph nodes in the analysis. Any relapse (locoregional/distant) occurred in 58 patients (77%), while involved nodal relapse (INR) was observed in 13% of patients. No dose-response relationship was observed for INR (p = .22). Primary tumor progression was seen in 40% of patients together with a significant dose-response relationship (p = .033). Baseline nodal diameter was not associated with INR (p = .76), while primary tumor diameter was a highly significant predictor for relapse (p = .0031). CONCLUSIONS: These results suggest that LN control may be achieved at lower radiation doses than needed for the primary tumor. Prospective dose de-escalation studies on LN are warranted to decrease the incidence of severe esophagitis without compromising local tumor control.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Metástase Linfática/radioterapia , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/patologia , Quimiorradioterapia/métodos , Relação Dose-Resposta à Radiação , Feminino , Humanos , Estimativa de Kaplan-Meier , Neoplasias Pulmonares/mortalidade , Neoplasias Pulmonares/patologia , Metástase Linfática/patologia , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Estudos Retrospectivos
10.
Acta Oncol ; 55(12): 1450-1455, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27732127

RESUMO

BACKGROUND: The gross tumor volume (GTV) definition for malignant pleural mesothelioma (MPM) is ill-defined. We therefore investigated which imaging modality is optimal: computed tomography (CT) with intravenous contrast (IVC), positron emission tomography-CT (PET/CT) or magnetic resonance imaging (MRI). MATERIAL AND METHODS: Sixteen consecutive patients with untreated stage I-IV MPM were included. Patients with prior pleurodesis were excluded. CT with IVC, 18FDG-PET/CT and MRI (T2 and contrast-enhanced T1) were obtained. CT was rigidly co-registered with PET/CT and with MRI. Three sets of pleural GTVs were defined: GTVCT, GTVCT+PET/CT and GTVCT+MRI. Quantitative and qualitative evaluations of the contoured GTVs were performed. RESULTS: Compared to CT-based GTV definition, PET/CT identified additional tumor sites (defined as either separate nodules or greater extent of a known tumor) in 12/16 patients. Compared to either CT or PET/CT, MRI identified additional tumor sites in 15/16 patients (p = .7). The mean GTVCT, GTVCT+PET/CT and GTVCT+MRI [±standard deviation (SD)] were 630.1 cm3 (±302.81), 640.23 cm3 (±302.83) and 660.8 cm3 (±290.8), respectively. Differences in mean volumes were not significant. The mean Jaccard Index was significantly lower in MRI-based contours versus all the others. CONCLUSION: As MRI identified additional pleural disease sites in the majority of patients, it may play a role in optimal target volume definition.


Assuntos
Neoplasias Pulmonares/patologia , Pulmão/efeitos da radiação , Mesotelioma/patologia , Imagem Multimodal/métodos , Tratamentos com Preservação do Órgão , Neoplasias Pleurais/patologia , Radioterapia de Intensidade Modulada/métodos , Idoso , Simulação por Computador , Feminino , Fluordesoxiglucose F18 , Seguimentos , Humanos , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/radioterapia , Imageamento por Ressonância Magnética , Masculino , Mesotelioma/metabolismo , Mesotelioma/radioterapia , Mesotelioma Maligno , Estadiamento de Neoplasias , Neoplasias Pleurais/metabolismo , Neoplasias Pleurais/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Prognóstico , Estudos Prospectivos , Compostos Radiofarmacêuticos , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Taxa de Sobrevida , Carga Tumoral
11.
Clin Chem Lab Med ; 54(8): 1347-55, 2016 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-26741345

RESUMO

BACKGROUND: In this study, we provide a short analytical evaluation of the new Fujirebio Lumipulse®G non-competitive immunoassay for 25(OH)D. Clinical performance was compared with three commercial competitive automated immunoassays against a Vitamin D Standardization Program (VDSP)-traceable liquid chromatography-tandem mass spectrometry (LC-MS/MS) in six different clinically relevant populations. METHODS: Lumipulse®G 25(OH)D precision, measurement uncertainty, recovery, limit of quantification were assessed, as well as 25(OH)D2 and C3-epimer recovery. For method comparison, 250 serum samples obtained in healthy Caucasians and Africans, osteoporotic, hemodialyzed and intensive care patients and 3rd trimester pregnant women were analyzed by all methods. Correlation was studied using Passing-Bablok and Bland-Altman analysis. Concordance correlation coefficient (CCC) was calculated to evaluate agreement between immunoassays and the LC-MS/MS. RESULTS: The Lumipulse®G 25(OH)D assay presented interesting analytical features and showed excellent correlation to the LC-MS/MS results (y=1.00×-1.35 ng/mL), as obtained in healthy Caucasian individuals. In the other special populations, Lumipulse®G presented a concordance with LC-MS/MS which was generally higher than competitors, even if all methods significantly under-recovered 25(OH)D in hemodialyzed patients. Intra-assay CV ranged from 12.1% at 9.6 ng/mL to 2.1% at 103.7 ng/mL and inter-assay CV ranged from 16.2 to 3.7% at the same concentrations, respectively. Measurement uncertainty, with a probability of 95%, were respectively 33.1 and 7.6% at these concentrations. LOQ was found to be at 4.6 ng/mL. Mean (95% CI) 25(OH)D2 revovery was 77% (74-81) and no cross-reactivity was observed with C3-epimer. CONCLUSIONS: Fujirebio Lumipulse®G 25-OH Vitamin D Total assay is therefore considered suitable for assessment of vitamin D status in clinical routine.


Assuntos
População Negra , Cuidados Críticos , Imunoensaio , Osteoporose/sangue , Terceiro Trimestre da Gravidez/sangue , Diálise Renal , Vitamina D/análogos & derivados , Cromatografia Líquida , Feminino , Voluntários Saudáveis , Humanos , Gravidez , Espectrometria de Massas em Tandem , Vitamina D/sangue , População Branca
12.
Carcinogenesis ; 36(2): 256-71, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25586992

RESUMO

The chromosomal passenger complex (CPC) plays a pivotal role in the regulation of cell division. Therefore, inherited CPC variability could influence tumor development. The present candidate gene approach investigates the relationship between single nucleotide polymorphisms (SNPs) in genes encoding key CPC components and breast cancer risk. Fifteen SNPs in four CPC genes (INCENP, AURKB, BIRC5 and CDCA8) were genotyped in 88 911 European women from 39 case-control studies of the Breast Cancer Association Consortium. Possible associations were investigated in fixed-effects meta-analyses. The synonymous SNP rs1675126 in exon 7 of INCENP was associated with overall breast cancer risk [per A allele odds ratio (OR) 0.95, 95% confidence interval (CI) 0.92-0.98, P = 0.007] and particularly with estrogen receptor (ER)-negative breast tumors (per A allele OR 0.89, 95% CI 0.83-0.95, P = 0.0005). SNPs not directly genotyped were imputed based on 1000 Genomes. The SNPs rs1047739 in the 3' untranslated region and rs144045115 downstream of INCENP showed the strongest association signals for overall (per T allele OR 1.03, 95% CI 1.00-1.06, P = 0.0009) and ER-negative breast cancer risk (per A allele OR 1.06, 95% CI 1.02-1.10, P = 0.0002). Two genotyped SNPs in BIRC5 were associated with familial breast cancer risk (top SNP rs2071214: per G allele OR 1.12, 95% CI 1.04-1.21, P = 0.002). The data suggest that INCENP in the CPC pathway contributes to ER-negative breast cancer susceptibility in the European population. In spite of a modest contribution of CPC-inherited variants to the total burden of sporadic and familial breast cancer, their potential as novel targets for breast cancer treatment should be further investigated.


Assuntos
Proteínas Cromossômicas não Histona/genética , Predisposição Genética para Doença , Receptores de Estrogênio/metabolismo , Regiões 3' não Traduzidas/genética , Aurora Quinase B/genética , Neoplasias da Mama/genética , Neoplasias da Mama/patologia , Estudos de Casos e Controles , Proteínas de Ciclo Celular/genética , Feminino , Estudo de Associação Genômica Ampla , Humanos , Proteínas Inibidoras de Apoptose/genética , Polimorfismo de Nucleotídeo Único , Risco , Survivina , População Branca/genética
13.
Lancet Oncol ; 15(13): e620-e624, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25456380

RESUMO

As the prognosis of lung cancer patients improves, more patients are at risk of developing local recurrence or a new primary tumour in previously irradiated areas. Technological advances in radiotherapy and imaging have made treatment of patients with high-dose re-irradiation possible, with the aim of long-term disease-free survival and even cure. However, high-dose re-irradiation with overlapping volumes of previously irradiated tissues is not without risks. Late, irreversible, and potentially serious normal tissue damage may occur because of injury to surrounding thoracic structures and organs at risk. In this Review, we aimed to report the efficacy and toxic effects of high-dose re-irradiation for locoregional recurrent non-small-cell lung cancer. Our findings indicate that high-dose re-irradiation might be beneficial in selected patients; however, patients and physicians should be aware of the scarcity of high-quality data when considering this treatment.


Assuntos
Braquiterapia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Humanos , Retratamento
14.
Artigo em Inglês | MEDLINE | ID: mdl-38039597

RESUMO

Cardiovascular diseases have cast a significant negative impact on the lives of millions worldwide. Over the years, extensive efforts have been dedicated to enhancing diagnostic and prognostic tools for these diseases. A growing body of evidence indicates that the angiotensin convertase enzyme (ACE) and the angiotensin convertase enzyme 2 (ACE2), and angiotensin peptide levels could hold a pivotal role in assisting clinicians with the management of cardiovascular conditions, notably hypertension and heart failure. However, despite the considerable body of knowledge in this domain, a void remains in the field of analytical methodologies for these molecules. In this study, we present a fully validated LC-MS/MS method for the precise quantitation of plasma angiotensin (1-7), (1-8), (1-9), and (1-10), following the guidelines set by the Clinical and Laboratory Standards Institute (CLSI). Our method not only enables the accurate quantification of angiotensin peptides but also provides a means to assess ACE and ACE2 activity. Remarkably, our method achieved a Lower Limit of Measurement Interval (LLMI) as low as 5 pg/mL. This has enabled the detection of angiotensin (1-7), (1-8), (1-9) and (1-10) and the accurate quantitation of angiotensin (1-7), (1-8) and (1-10) in all analyzed groups, including healthy controls, patients with high blood pressure, and patients with chronic kidney disease. To our knowledge, our method represents the most sensitive approach allowing for simultaneous quantitation of these four angiotensin peptides. A distinct advantage of our method, when compared to immunoassays, is its high sensitivity combined with comprehensive chromatographic separation of all currently known angiotensin peptides. This combination translates to an exceptional level of selectivity, underscoring the value and potential of our methodology in advancing cardiovascular disease research.


Assuntos
Doenças Cardiovasculares , Espectrometria de Massa com Cromatografia Líquida , Fragmentos de Peptídeos , Humanos , Cromatografia Líquida/métodos , Enzima de Conversão de Angiotensina 2 , Espectrometria de Massas em Tandem/métodos , Angiotensina I , Peptídeos , Angiotensina II
15.
Radiother Oncol ; 190: 110048, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38070686

RESUMO

AIM: The current work aimed to investigate the clinical benefit of radiotherapy in patients with metastatic non-small cell lung cancer (NSCLC) developing acquired resistance to immune checkpoint inhibitors. METHOD: We report on a pooled, two-institution, phase II single-arm prospective cohort study. The study included patients with stage IV NSCLC who showed progression of one or more measurable lesions under anti-PD-(L)1 inhibition alone, after initially having achieved at least stable disease. Hypofractionated radiotherapy (hRT) of one to four metastases was performed, while one or more lesions were kept untreated. Following hRT, treatment with immune checkpoint inhibitors was continued unchanged until further evidence of tumor progression or unacceptable toxicity. Primary endpoint of the pooled analysis was progression-free survival (PFS), secondary endpoints included overall survival (OS) and toxicity. RESULTS: A total of 48 patients were enrolled: mean age was 67.1 ± 9.3 years, 50 % were male and 72.9 % were PD-L1 positive. Immunotherapy was in 95.8 % of patients the first or second line therapy at time of enrollment. hRT was performed to one (93.8 % of cases) or more lesions (median total dose: 27.5 Gy, median 6.5 Gy/fraction). Forty-five patients (93.8 %) were able to continue immunotherapy for a median of 6.2 months following hRT. Median PFS was 4.4 months, with 62.5 % disease control at three months and 37.5 % at six months. Median OS was 14.9 months. Severe adverse events (grade ≥ 2) were reported in 12 cases (25 %), of which none were radiotherapy-related and four were immunotherapy-related. Salvage therapy consisted of chemotherapy (48.8 %) or repeated irradiation (21.9 %). No further tumor treatment was performed in 29.3 % of patients. CONCLUSIONS: The current pooled analysis is a prospective evaluation of the role of radiation therapy for metastatic NSCLC in the setting of newly acquired immunotherapy resistance. Hypofractionated radiotherapy can support the outcome of immune checkpoint inhibitors and thus allow continuation of treatment for a relevant amount of time despite initial tumor progression.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/tratamento farmacológico , Inibidores de Checkpoint Imunológico/efeitos adversos , Estudos Prospectivos , Imunoterapia/efeitos adversos , Antígeno B7-H1/metabolismo , Ensaios Clínicos Fase II como Assunto
16.
Acta Oncol ; 52(7): 1405-10, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23957564

RESUMO

BACKGROUND: Radiation-induced lung damage (RILD) is an important problem. Although physical parameters such as the mean lung dose are used in clinical practice, they are not suited for individualised radiotherapy. Objective, quantitative measurements of RILD on a continuous instead of on an ordinal, semi-quantitative, semi-subjective scale, are needed. METHODS: Hounsfield unit (HU) changes before versus three months post-radiotherapy were correlated per voxel with the radiotherapy dose in 95 lung cancer patients. Deformable registration was used to register pre- and post-CT scans and the density increase was quantified for various dose bins. The dose-response curve for increased HU was quantified using the slope of a linear regression (HU/Gy). The end-point for the toxicity analysis was dyspnoea ≥ grade 2. RESULTS: Radiation dose was linearly correlated with the change in HU (mean R(2) = 0.74 ± 0.28). No differences in HU/Gy between groups treated with stereotactic radiotherapy, conventional radiotherapy alone, sequential or concurrent chemo- radiotherapy were observed. In the whole patient group, 33/95 (34.7%) had dyspnoea ≥ G2. Of the 48 patients with a HU/Gy below the median, 16 (33.3%) developed dyspnoea ≥ G2, while in the 47 patients with a HU/Gy above the median, 17 (36.1%) had dyspnoea ≥ G2 (not significant). Individual patients showed a nearly 21-fold difference in radiosensitivity, with HU/Gy ranging from 0 to 10 HU/Gy. CONCLUSIONS: HU changes identify objectively the whole range of individual radiosensitivity on a continuous, quantitative scale. CT density changes may allow more robust and accurate radiogenomics studies.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Dispneia/diagnóstico por imagem , Genômica , Neoplasias Pulmonares/radioterapia , Pneumonite por Radiação/diagnóstico por imagem , Radioterapia/efeitos adversos , Carcinoma de Pequenas Células do Pulmão/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/patologia , Dispneia/etiologia , Dispneia/patologia , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Pneumonite por Radiação/etiologia , Pneumonite por Radiação/patologia , Radiografia Torácica , Dosagem Radioterapêutica , Estudos Retrospectivos , Carcinoma de Pequenas Células do Pulmão/patologia , Tomografia Computadorizada por Raios X
17.
Radiother Oncol ; 183: 109594, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36870610

RESUMO

PURPOSE: In this study we describe the clinical introduction and evaluation of radiotherapy in mediastinal lymphoma in breath hold using surface monitoring combined with nasal high flow therapy (NHFT) to prolong breath hold duration. MATERIALS AND METHODS: 11 Patients with mediastinal lymphoma were evaluated. 6 Patients received NHFT, 5 patients were treated in breath hold without NHFT. Breath hold stability as measured by a surface scanning system was evaluated, as well as internal movement based on cone beam computed tomography (CBCT) before and after treatment. Based on internal movement, margins were determined. In a parallel planning study we compared free breathing plans with breath hold plans using the determined margins. RESULTS: Average inter breath hold stability was 0.6 mm for NHFT treatments, and 0.5 mm for non-NHFT treatments (p > 0.1). Intra breath hold stability was 0.8 vs. 0.6 mm (p > 0.1) on average. Using NHFT, average breath hold duration increased from 34 s to 60 s (p < 0.01). Residual CTV motion derived from CBCTs before and after each fraction was 2.0 mm for NHFT vs 2.2 mm for non-NHFT (p > 0.1). Combined with inter-fraction motion, a uniform mediastinal margin of 5 mm appears to be sufficient. In breath hold, mean lung dose is reduced by 2.6 Gy (p < 0.001), while mean heart dose is reduced by 2.0 Gy (p < 0.001). CONCLUSION: Treatment of mediastinal lymphoma in breath hold is feasible and safe. The addition of NHFT approximately increases breath hold durations with a factor two while stability is maintained. By reducing breathing motion, margins can be decreased to 5 mm. A considerable dose reduction in heart, lungs, esophagus, and breasts can be achieved with this method.


Assuntos
Linfoma , Neoplasias do Mediastino , Humanos , Suspensão da Respiração , Planejamento da Radioterapia Assistida por Computador/métodos , Respiração , Pulmão , Neoplasias do Mediastino/diagnóstico por imagem , Neoplasias do Mediastino/radioterapia , Dosagem Radioterapêutica , Linfoma/diagnóstico por imagem , Linfoma/radioterapia
18.
Artigo em Inglês | MEDLINE | ID: mdl-37634391

RESUMO

Since the late 1990s, cathepsin K cleavage sites in type I collagen have been extensively studied due to its ability to release bone resorption biomarkers such as CTX and NTX. However, gel-based methods and N-sequencing used in these studies lack sensitivity, especially for small to medium peptides. In this work, we propose a degradomics mass spectrometry-based workflow that combines protein digestion, Nano-LC-UDMSE, and several software tools to identify cathepsin K cleavage sites. This workflow not only identified previously known cleavage sites, but also discovered new ones. Multiple cleavage hotspots were found and described in type I α1 and type I α2 collagen, many of which coincided with pyridinoline crosslinks, known to stabilize the triple helix. Our results allowed us to establish a chronology of digestion and conclude that cathepsin K preferentially cleaves the extremities of type I collagen before the helical part. We also found that cathepsin K preferentially cleaves amino acid residues with long and hydrophobic lateral chains at the beginning of digestion, whereas no preferred amino acid residues were identified later in the digestion. In conclusion, our workflow successfully identified new cleavage sites and can be easily applied to other proteins or proteases.


Assuntos
Aminoácidos , Colágeno Tipo I , Catepsina K , Fluxo de Trabalho , Espectrometria de Massas
19.
J Am Soc Mass Spectrom ; 34(6): 1056-1064, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37130062

RESUMO

A growing body of literature describes the potential effects of circadian disruption on human health. Indeed, psychiatric diseases, metabolic syndrome, and cancers may be linked to disturbance of the circadian rhythm. Currently, the best practice to assess circadian rhythm is the measurement of melatonin levels. Our goal was thus to develop and validate a highly sensitive LC-MS/MS method to follow salivary melatonin levels throughout the day and night. Our method reached a lower limit of the measuring interval (LLMI) of 0.8 pg/mL. To our knowledge, it is the most sensitive method allowing quantitation of melatonin in saliva. Saliva, obtained from passive drooling or salivette, was extracted by an efficient and quick liquid-liquid extraction with no further cleanup needed. The method was validated according to the European Medicines Agency (EMA) guidelines and provided excellent results regarding accuracy, precision, linearity, selectivity, and specificity. Comparison between radioimmunoassay and our method was performed and showed differences at low levels, most likely due to cross-reactivity with other indols. To assess daytime melatonin levels in humans, salivary melatonin levels of ten volunteers were monitored throughout the day and showed lower daytime levels than reported in previous studies.


Assuntos
Melatonina , Saliva , Humanos , Cromatografia Líquida/métodos , Saliva/metabolismo , Melatonina/metabolismo , Espectrometria de Massas em Tandem/métodos , Ritmo Circadiano
20.
Phys Imaging Radiat Oncol ; 27: 100459, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37397874

RESUMO

Background and purpose: Efficient workflows for adaptive proton therapy are of high importance. This study evaluated the possibility to replace repeat-CTs (reCTs) with synthetic CTs (sCTs), created based on cone-beam CTs (CBCTs), for flagging the need of plan adaptations in intensity-modulated proton therapy (IMPT) treatment of lung cancer patients. Materials and methods: Forty-two IMPT patients were retrospectively included. For each patient, one CBCT and a same-day reCT were included. Two commercial sCT methods were applied; one based on CBCT number correction (Cor-sCT), and one based on deformable image registration (DIR-sCT). The clinical reCT workflow (deformable contour propagation and robust dose re-computation) was performed on the reCT as well as the two sCTs. The deformed target contours on the reCT/sCTs were checked by radiation oncologists and edited if needed. A dose-volume-histogram triggered plan adaptation method was compared between the reCT and the sCTs; patients needing a plan adaptation on the reCT but not on the sCT were denoted false negatives. As secondary evaluation, dose-volume-histogram comparison and gamma analysis (2%/2mm) were performed between the reCT and sCTs. Results: There were five false negatives, two for Cor-sCT and three for DIR-sCT. However, three of these were only minor, and one was caused by tumour position differences between the reCT and CBCT and not by sCT quality issues. An average gamma pass rate of 93% was obtained for both sCT methods. Conclusion: Both sCT methods were judged to be of clinical quality and valuable for reducing the amount of reCT acquisitions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA