RESUMO
BACKGROUND AND PURPOSE: Although cognitive impairment (CI) is frequent in multiple sclerosis (MS) patients, few studies (and with conflicting results) have evaluated early predictors of CI in the long term. We aimed at determining associations between early clinical/neuroradiological variables with reference to CI after 20 years of MS. METHODS: We investigated in 170 MS patients the relationship between clinical/magnetic resonance imaging (MRI) data at diagnosis and cognitive status almost 20 years after MS onset. Among others, number and volume of both white matter lesions (WMLs) and cortical lesions (CLs) were evaluated at diagnosis and after 2 years. All MS patients were followed over time and underwent a comprehensive neuropsychological assessment at the end of study. Advanced statistical methods (unsupervised cluster analysis and random forest model) were conducted. RESULTS: CI patients showed higher focal cortical pathology at diagnosis compared to cognitively normal subjects (p < 0.001). Volumes of both WMLs and CLs emerged as the MRI metrics most associated with long-term CI. Moreover, number of CLs (especially ≥3) was also strongly associated with long-term CI (≥3 CLs: odds ratio [OR] = 3.7, 95% confidence interval = 1.8-7.5, p < 0.001), more than number of WMLs; the optimal cutoff of three CLs (area under the curve = 0.67, specificity = 75%, sensitivity = 55%) was estimated according to the risk of developing CI. CONCLUSIONS: These results highlight the impact of considering both white and gray matter focal damage from early MS stages. Given the low predictive value of WML number and the poor clinical applicability of lesion volume estimation in the daily clinical context, the evaluation of number of CLs could represent a reliable prognostic marker of CI.
Assuntos
Disfunção Cognitiva , Esclerose Múltipla , Humanos , Esclerose Múltipla/complicações , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Disfunção Cognitiva/etiologia , Disfunção Cognitiva/complicações , Substância Cinzenta/diagnóstico por imagem , Substância Cinzenta/patologia , Imageamento por Ressonância Magnética/métodos , Testes Neuropsicológicos , Córtex Cerebral/patologia , Encéfalo/patologiaRESUMO
INTRODUCTION: Ocrelizumab (OCR) and Fingolimod (FGL) are two high-efficacy treatments in multiple sclerosis which, besides their strong anti-inflammatory activity, may limit neurodegeneration. AIM: To compare the effect of OCR and FGL on clinical and MRI endpoints. METHODS: 95 relapsing-remitting patients (57 OCR, 38 FGL) clinically followed for 36 months underwent a 3-Tesla MRI at baseline and after 24 months. The annualized relapse rate, EDSS, new cortical/white matter lesions and regional cortical and deep grey matter volume loss were evaluated. RESULTS: OCR reduced the relapse rate from 0.48 to 0.04, FGL from 0.32 to 0.05 (both p < 0.001). Compared to FGL, OCR-group experienced fewer new white matter lesions (12% vs 32%, p = 0.005), no differences in new cortical lesions, lower deep grey matter volume loss (- 0.12% vs - 0.66%; p = 0.002, Cohen's d = 0.54), lower global cortical thickness change (- 0.45% vs - 0.70%; p = 0.036; d = 0.42) and reduced cortical thinning/volume loss in several regions of interests, including those of parietal gyrus (d-range = 0.65-0.71), frontal gyrus (d-range = 0.47-0.60), cingulate (d-range = 0.41-0.72), insula (d = 0.36), cerebellum (cortex d = 0.72, white matter d = 0.44), putamen (d = 0.35) and thalamus (d = 0.31). The effect on some regional thickness changes was confirmed in patients without focal lesions. CONCLUSIONS: When compared with FGL, patients receiving OCR showed greater suppression of focal MRI lesions accumulation and lower cortical and deep grey matter volume loss.
Assuntos
Anticorpos Monoclonais Humanizados , Cloridrato de Fingolimode , Substância Cinzenta , Imageamento por Ressonância Magnética , Esclerose Múltipla Recidivante-Remitente , Humanos , Feminino , Masculino , Adulto , Substância Cinzenta/diagnóstico por imagem , Substância Cinzenta/patologia , Substância Cinzenta/efeitos dos fármacos , Anticorpos Monoclonais Humanizados/farmacologia , Anticorpos Monoclonais Humanizados/administração & dosagem , Anticorpos Monoclonais Humanizados/uso terapêutico , Esclerose Múltipla Recidivante-Remitente/tratamento farmacológico , Esclerose Múltipla Recidivante-Remitente/diagnóstico por imagem , Esclerose Múltipla Recidivante-Remitente/patologia , Pessoa de Meia-Idade , Cloridrato de Fingolimode/farmacologia , Cloridrato de Fingolimode/uso terapêutico , Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/patologia , Córtex Cerebral/efeitos dos fármacos , Moduladores do Receptor de Esfingosina 1 Fosfato/farmacologia , Fatores Imunológicos/farmacologia , Fatores Imunológicos/administração & dosagem , SeguimentosRESUMO
PURPOSE: Intracardiac transcatheter interventions allow for reducing trauma and hospitalization stays as compared to standard surgery. In the treatment of mitral regurgitation, the most widely adopted transcatheter approach consists in deploying a clip on the mitral valve leaflets by means of a catheter that is run through veins from a peripheral access to the left atrium. However, precise manipulation of the catheter from outside the body while copying with the path constraints imposed by the vessels remains challenging. METHODS: We proposed a path tracking control framework that provides adequate motion commands to the robotic steerable catheter for autonomous navigation through vascular lumens. The proposed work implements a catheter kinematic model featuring nonholonomic constraints. Relying on the real-time measurements from an electromagnetic sensor and a fiber Bragg grating sensor, a two-level feedback controller was designed to control the catheter. RESULTS: The proposed method was tested in a patient-specific vessel phantom. A median position error between the center line of the vessel and the catheter tip trajectory was found to be below 2 mm, with a maximum error below 3 mm. Statistical testing confirmed that the performance of the proposed method exhibited no significant difference in both free space and the contact region. CONCLUSION: The preliminary in vitro studies presented in this paper showed promising accuracy in navigating the catheter within the vessel. The proposed approach enables autonomous control of a steerable catheter for transcatheter cardiology interventions without the request of calibrating the intuitive parameters or acquiring a training dataset.
Assuntos
Cardiologia , Insuficiência da Valva Mitral , Robótica , Humanos , Catéteres , Valva MitralRESUMO
The impact of disease-modifying therapies (DMTs) on the immune response to coronavirus disease-2019 (COVID-19) vaccines in persons with multiple sclerosis (pwMS) needs further elucidation. We investigated BNT162b2 mRNA COVID-19 vaccine effects concerning antibody seroconversion, inflammatory mediators' level and immunophenotype assessment in pwMS treated with cladribine (c-pwMS, n = 29), fingolimod (f-pwMS, n = 15) and ocrelizumab (o-pwMS, n = 54). Anti-spike immunoglobulin (Ig)-G detection was performed by an enzyme immunoassay; molecular mediators (GrB, IFN-γ and TNF-α) were quantified using the ELLA platform, and immunophenotype was assessed by flow cytometry. ANCOVA, Student's t-test and Pearson correlation analyses were applied. Only one o-pwMS showed a mild COVID-19 infection despite most o-pwMS lacking seroconversion and showing lower anti-spike IgG titers than c-pwMS and f-pwMS. No significant difference in cytokine production and lymphocyte count was observed in c-pwMS and f-pwMS. In contrast, in o-pwMS, a significant increase in GrB levels was detected after vaccination. Considering non-seroconverted o-pwMS, a significant increase in GrB serum levels and CD4+ T lymphocyte count was found after vaccination, and a negative correlation was observed between anti-spike IgG production and CD4+ T cells count. Differences in inflammatory mediators' production after BNT162b2 vaccination in o-pwMS, specifically in those lacking anti-spike IgG, suggest a protective cellular immune response.