Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(24)2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38139670

RESUMO

This paper presents a novel technique for the mass flow rate determination of particulate solids called the "Sliding Mass Technique". The mass flow rate is a measure of the mass of a substance that passes through a given cross-sectional area per unit time. Its calculation requires simultaneous detection of the concentration and velocity of the Material Under Test. A novel measurement technique is designed for determining the concentration of the mass flow without the necessity for density evaluation. The mass flow rate is determined by fusing the established concentration results with velocity results obtained from "Microwave Spatial Filtering Velocimetry". A new metamaterial-based mass flow sensor for particulate solids was designed, realized and measured in an industrial environment. A Software-Defined Radio (Ettus Research™'s USRP B210) was utilized as a sensor electronic system for DAQ purposes. A MATLAB app was developed to operate the SDR. Measurements were carried out on-site using a state-of-the-art wood pellet heating system with wood pellets with different moisture contents. The measurement results were found to be in very good agreement with the expected results, which strengthens the feasibility of this newly proposed measurement technique.

2.
Sensors (Basel) ; 23(7)2023 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-37050531

RESUMO

We present the characterization of a Zero-bias Schottky diode-based Terahertz (THz) detector up to 5.56 THz. The detector was operated with both a table-top system until 1.2 THz and at a Free-Electron Laser (FEL) facility at singular frequencies from 1.9 to 5.56 THz. We used two measurement techniques in order to discriminate the sub-ns-scale (via a 20 GHz oscilloscope) and the ms-scale (using the lock-in technique) responsivity. While the lock-in measurements basically contain all rectification effects, the sub-ns-scale detection with the oscilloscope is not sensitive to slow bolometric effects caused by changes of the IV characteristic due to temperature. The noise equivalent power (NEP) is 10 pW/Hz in the frequency range from 0.2 to 0.6 THz and 17 pW/Hz at 1.2 THz and increases to 0.9 µW/Hz at 5.56 THz, which is at the state of the art for room temperature zero-bias Schottky diode-based THz detectors with non-resonant antennas. The voltage and current responsivity of ∼500 kV/W and ∼100 mA/W, respectively, is demonstrated over a frequency range of 0.2 to 1.2 THz with the table-top system.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA