Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(5): 741-750, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38451154

RESUMO

BACKGROUND: The GCA is a well performing device in terms of efficacy despite complex anatomies (aortic rim <5 mm and ASD diameter >17 mm) with a good safety profile. AIMS: To evaluate atrial septal defect (ASD) features impacting on right disc device thrombosis in patients who underwent Gore Cardioform ASD Occluder (GCA) implantation. METHODS: A total of 44 consecutive patients undergoing percutaneous ASD with GCA device from January 2020 to September 2022 at our tertiary care Center were evaluated. The minimum follow-up was 6 months. RESULTS: The patients were stratified in two groups according to a cut-off value of ASD diameter equal to 20 mm at sizing balloon, derived from ROC analysis (AUC = 0.894; p = 0.024). Baseline characteristics were comparable between groups in terms of age, sex, weight, height, and interatrial septum dimensions. Patients with ASD > 20 mm (n = 9) had a higher ASD/device dimension ratio, both at echocardiography (p = 0.009) and at sizing balloon (p = 0.001), longer fluoroscopic time (p = 0.022), and higher incidence of device thrombosis (0.006). Right disc thrombosis was observed in three patients of the ASD > 20 mm group, always in the inferior portion of the right disc. On univariate analysis, ASD diameter at sizing balloon (OR 1.360; p = 0.036) was the only positive predictor of device thrombosis. CONCLUSIONS: Right disc thrombosis of the GCA device may be under-recognized at follow-up, hence deserving clinical attention, especially in those patients with larger ASD diameters.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Ecocardiografia Transesofagiana , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia
2.
Catheter Cardiovasc Interv ; 89(3): 480-483, 2017 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-27515784

RESUMO

INTRODUCTION: Patent foramen ovale (PFO) closure is a widely performed procedure. Understanding the anatomy is mandatory in order to perform the procedure successfully. The degree of overlap between the septum primum and secundum is called the tunnel. In particular, long and stiff tunnels may prevent the correct positioning of devices that have a fixed distance between the right and left atrial discs. PATIENTS AND METHODS: We evaluated retrospectively 361 patients with PFO closure between January 2012 and June 2014 in our institution and were treated due to previous history of ischemic stroke. By TEE, the overlap between septum primum and secundum is usually better seen on the bicaval view that is obtained at 75-90° midesophageal views. Tunnel length and PFO opening were measured. Twelve subjects (median age 35 years; range 30-58 years; three females) showed a long (median 22 mm; range 15-32 mm) and rigid tunnel (median opening 2 mm; range 1-4 mm). RESULTS: Angioplasty of the tunnel was performed by using peripheral angioplasty balloons with a length ranging from 4 to 8 cm and a diameter between 8 and 12 mm. After angioplasty, the tunnel appeared shorter (12 mm; range 8-16 mm) and less rigid (median opening 8 mm; range 7-12 mm). The following devices were implanted: 25 mm Amplatzer PFO occluder in three patients; 25 mm Gore septal occluder in nine subjects. Median fluoroscopy time was 8 min (range 6-10 min). No complications occurred. At a median follow-up of 12 months (range 2-18 months), no problems occurred and all subjects but one (trivial residual shunting) showed a complete closure. CONCLUSIONS: Angioplasty of a PFO rigid and stiff tunnel is a feasible and safe option. © 2016 Wiley Periodicals, Inc.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Forame Oval Patente/terapia , Dispositivo para Oclusão Septal , Adulto , Angioplastia Coronária com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Fluoroscopia , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia Intervencionista , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
3.
Eur Heart J Suppl ; 18(Suppl E): E22-E26, 2016 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-28533712

RESUMO

The right timing to replace the pulmonary valve in a patient with dysfunction of the right ventricular outflow tract is unknown. Both percutaneous pulmonary valve and surgical prosthesis are suitable options. In every patient, the right ventricle (RV) remodels and recovers differently after pulmonary replacement. Therefore, it is difficult to identify the best treatment option and to predict the long-term results. In the last few years, we focused our research on optimizing the characterization of these patients through advanced cardiovascular imaging in order to find possible variables, parameters, and reproducible measurements that can help us in the decision-making process. The aim of the present article is to present our ongoing research lines that focus on the characterization and optimal treatment approach to the dysfunction of the RVOT.

4.
Catheter Cardiovasc Interv ; 86(3): 432-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25645254

RESUMO

BACKGROUND: Intravascular stenting is the procedure of choice in the treatment of vascular stenoses. However, in infants and small children large sheaths are needed, and adult-size stents cannot be implanted. The Valeo Biliary Lifestent (Edwards Lifesciences Irvine, CA) is low profile and can be dilated up to 18-20 mm. We aimed to report on early and mid-term results with the use of Valeo stents in infants and children with congenital heart disease. METHODS: Twenty-five subjects were treated in our experience. Mean age and weight were 39 ± 35 months (range 1-132) and 10.4 ± 6.7 kg (range 3-30), respectively. Two groups of patients were: Group A: patients with pulmonary artery stenosis (21 subjects); Group B subjects in whom stenting was applied in other vessel or heart sites (four subjects). RESULTS: A total of 35 stents were successfully used. Fluoroscopy time was 32 ± 11 min. No intra-operative death or hospital mortality was recorded. Stent post dilatation was performed in nine patients. The incidence of complication was 12% (3/25) (two subjects developed transient hypotension and bradycardia which required inotropic treatment, 1 patient developed mild lung bleeding). There was a significant improvement of angiographic appearance and RV pressure (RV/AO systolic pressure ratio before 1 ± 02 (range 0.8-1.5) versus after the procedure 0.6 ± 0.2 (range 0.4-0.9) P < 0.001). In group B stents were successfully implanted in aortic recoarctation, interatrial septum and in two modified BT shunts. At a median follow-up of 18 months (range 1-24 months) results remained stable and no complications occurred. In particular no stent fractures were seen. Furthermore, redilation was performed safely and successfully in three subjecs up to 18 months after the first implantation. CONCLUSIONS: In our series, Valeo Lifestents have proven to be effective and with low incidence of complication in various anatomical settings, in low weight infants and in early post-operative course. Large series and longer follow-up are mandatory.


Assuntos
Cardiopatias Congênitas/terapia , Cuidados Paliativos , Stents , Criança , Pré-Escolar , Feminino , Fluoroscopia , Humanos , Lactente , Recém-Nascido , Masculino , Desenho de Prótese , Stents/efeitos adversos , Resultado do Tratamento
5.
Echocardiography ; 32 Suppl 1: S38-52, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24646193

RESUMO

The right ventricle (RV) is of lesser importance in acquired heart disease, but its role is of increasing importance in congenital heart disease (CHD). Despite major progress being made, precise measurements of the RV are challenging because of its peculiar anatomical structure that is not adaptable to any planar geometrical assumption. This is particularly true in adult patients with CHD where the RV shape eludes any standardization, it may assume various morphologies, and its modality of contraction depends on previous surgical treatment and/or pathophysiological conditions. However, reliable and repeatable quantification of RV dimensions and function for these patients are essential to provide appropriate timing for intervention to optimize outcomes. In this population, echocardiographic evaluation should not be limited to an observational and subjective functional assessment of the RV but must provide quantitative values repeatable and clinically reliable to help the decision-making process. The aim of this review was to discuss the echocardiographic approach to the RV in adult patients with CHD in general and in specific cases of pressure or volume overload.


Assuntos
Ecocardiografia Doppler/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita/fisiologia , Adulto , Ecocardiografia Tridimensional/métodos , Feminino , Cardiopatias Congênitas/diagnóstico , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/diagnóstico por imagem , Humanos , Contração Miocárdica/fisiologia , Volume Sistólico/fisiologia , Tetralogia de Fallot/diagnóstico , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Direita/diagnóstico
6.
Cardiol Young ; 25(4): 790-3, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24909180

RESUMO

Percutaneous treatment of aortic coarctation is a widely used option. Covered stents have increased the profile of efficacy and safety of this procedure. Here we report on a 32-year-old woman with significant aortic recoarctation associated with aortic wall aneurysm and close proximity of both lesions to the origin of both the subclavian arteries. It was decided to manually and partially uncover the proximal part of the stent to have a hybrid stent that could act as a bare stent at the level of the origin of the subclavian arteries and as a covered stent at the level of the aneurysm.


Assuntos
Coartação Aórtica/cirurgia , Adulto , Aneurisma Aórtico/complicações , Aneurisma Aórtico/cirurgia , Coartação Aórtica/complicações , Coartação Aórtica/diagnóstico , Feminino , Humanos , Imageamento por Ressonância Magnética , Platina , Stents , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 83(6): 953-63, 2014 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-24459104

RESUMO

BACKGROUND: Bare stents has become the first line therapy for aortic coarctation. Covered stents has been reported more recently in clinical practice. OBJECTIVES: The present study, reports comparatively 15-year experience of bare and covered stent implantation for aortic coarctation in a single tertiary referral center. METHODS: From 1997 to 2011, 143 patients with native or postoperative aortic coarctation were treated at our institution. Seventy-one subjects (median age 17 years (range from 4 to 70 years) underwent bare stent implantation (Group 1) while 72 patients (median age of 17.5 years (range from 6 to 68 years) underwent covered stent implantation (Group 2). RESULTS: Success rate in the whole group was 95%. More complex and tighter coarctations were treated using covered stents. Incidence of related-procedure adverse events was higher in Group 1 than in group 2 (21.1% vs. 8.3% P = 0.035). Aortic wall complications occurred in 7% of patients in Group 1 (one death) and 0% in Group 2 (P = 0.028). Subjects in Group 1 had a longer follow-up (median 85 vs. 35 months; P < 0.001). Independent predictors associated with reintervention included the presence of complex lesions (HR: 2.70; CI: 1.15-6.32), balloon diameter used <14 mm (HR: 3.76; CI: 1.48-9.55), and immediate residual gradient >10 mm Hg (HR: 4.30; CI: 1.96-9.47). CONCLUSIONS: Both bare and covered stent implantation for aortic coarctation is a safe and efficacious treatment. By using covered stent implantation the spectrum of patients treated has increased with lower rates of acute and late complications.


Assuntos
Coartação Aórtica/terapia , Procedimentos Endovasculares/instrumentação , Stents , Adolescente , Adulto , Idoso , Coartação Aórtica/diagnóstico , Aortografia , Criança , Pré-Escolar , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Retratamento , Estudos Retrospectivos , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
8.
Radiol Med ; 119(6): 400-7, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24307165

RESUMO

PURPOSE: To measure the magnetic resonance (MR) artefact produced by a percutaneous pulmonary valve stent and to evaluate the changes in volumetric and functional right ventricle (RV) parameters due to percutaneous pulmonary valve implantation (PPVI). MATERIALS AND METHODS: A Melody valve was studied in vitro using clinical cardiac MR (CMR) sequences. In vivo, we analysed the CMR examinations obtained before and after PPVI of 27 consecutive patients. The echocardiography pressure gradient (PG) and catheter PG were measured. The Wilcoxon test was used for comparisons. RESULTS: In vitro, the least difference between artefact extent and actual valve size (0.1 mm) was obtained with a steady-state free precession (SSFP) sequence. In vivo, RV end-diastolic volume (ml/m(2)), end-systolic volume (ml/m(2)) and ejection fraction (%) were 79 ± 42, 43 ± 41 and 49 ± 13 before PPVI and 64 ± 21 (p = 0.054), 30 ± 14 (p = 0.021), and 54 ± 12 (p = 0.018) 6 months after PPVI, respectively. The PG and regurgitation fraction (RF) were 36 ± 15 mmHg and 14 ± 18 % before PPVI and 13 ± 15 mmHg (p < 0.001) and 2 ± 5 % (p = 0.013) after PPVI, respectively. No significant differences were found comparing the PG measured with CMR, echocardiography and catheter. CONCLUSIONS: We showed in vitro that the SSFP sequence produced the most accurate valve measurement. After PPVI, CMR showed a strong decrease of PG and RF with a significant improvement of RV function.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/métodos , Imageamento por Ressonância Magnética/métodos , Valva Pulmonar/cirurgia , Adulto , Artefatos , Cateterismo Cardíaco , Ecocardiografia , Feminino , Humanos , Masculino , Imagens de Fantasmas , Estudos Retrospectivos
9.
Diagnostics (Basel) ; 14(5)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38472942

RESUMO

We describe a case of a voluminous rhabdomyoma (R) detected by fetal echocardiography at 32 weeks' gestation (w.g.) obstructing the left ventricular inflow and aortic outflow tract, with a moderate aortic gradient at birth, not needing immediate surgery. At follow-up, the mass progressively regressed, leaving the aortic valve partly damaged, with a gradient that increased to a maximum of 100 mmHg at 9 years. The girl was then operated on successfully by a plasty of the aortic valve. The literature regarding R is discussed.

10.
Catheter Cardiovasc Interv ; 82(6): 950-8, 2013 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-23804551

RESUMO

INTRODUCTION: Initial transcatheter Percutaneous patent foramen ovale (PFO) closure attempt may be incomplete and result in persistent residual shunting. The optimal treatment strategy for these patients remains unknown. PATIENTS AND METHODS: Twenty-seven patients were diagnosed to have a moderate-large residual shunt at least 12 months after initial PFO closure associated or not to a recurrent ischemic event and underwent a second procedure. Residual shunt characteristics were classified in two types: Type I: tunnel-like or between the disk defect (11 patients); Type II: accessory defect next to a device rim or accessory defect (16 patients). RESULTS: Fourteen subjects had a recurrent transient ischemic attack/stroke (52%). Median time between the first and the second PFO closure procedure was 17 months (range 12-60 months). Deployment of a second device was successful in 92% (25/27) patients. A Type I defect was closed by using a coil or Amplatzer Vascular Plugs. In two patients a surgical option was chosen as a first option. A Type II defect was closed by using a double disc device. At a median follow-up of 36 months (range 12-60 months), two subjects showed significant residual shunting between the two disks of the device (Type I) at 12 months follow-up and were sent to surgery. CONCLUSIONS: Significant residual shunts can be successfully closed by using a second device. Care is required to select an optimal device depending on anatomy and original device. In some subjects, lack of endothelial covering account for the persistence of a significant residual shunting.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Circulação Cerebrovascular , Forame Oval Patente/terapia , Ataque Isquêmico Transitório/etiologia , Acidente Vascular Cerebral/etiologia , Adulto , Idoso , Cateterismo Cardíaco/instrumentação , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico , Forame Oval Patente/fisiopatologia , Humanos , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/fisiopatologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Recidiva , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
11.
Catheter Cardiovasc Interv ; 81(2): 310-6, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22718682

RESUMO

BACKGROUND AND AIMS: Percutaneous implantation of pulmonary valve has been recently introduced in the clinical practice. Our aim was to analyze data of patients treated in Italy by using the Melody Medtronic valve. METHODS: Prospective, observational, multi-centric survey by means of a web-based database registry of the Italian Society of Pediatric Cardiology (SICP). RESULTS: Between October 2007 and October 2010, 63 patients were included in the registry (median age: 24 years; range 11-65 years). Forty subjects were in NYHA class I-II while 23 were in NYHA class III-IV. Patients included had a history of a median three previous surgeries (range 1-5) and a median of one previous cardiac catheterization (range 0-4). A cono-truncal disease was present in 39 patients, previous Ross operation in 9, and other diagnosis in 15. Indication to valve implantation was pure stenosis in 21 patients, pure regurgitation in 12, association of stenosis and regurgitation in 30. Implantation was performed in 61 subjects (97%). Pre-stenting was performed in 85% of cases. Median procedure time was 170 minutes (range 85-360). No significant regurgitation was recorded after procedure while the trans-pulmonary gradient reduced significantly. Early major complications occurred in seven subjects (11%). One death occurred in the early post-operative period in a severely ill subject. At a median follow-up of 30 months (range 12-48 months), three patients died due to underlying disease. Major complications occurred in six patients during follow-up (external electric cardioversion: one patient; herpes virus encephalitis: two patients; Melody valve endocarditis needing surgical explant: two patients; major fractures of the stent and need second Melody valve implantation: two patients). Freedom from valve failure at latest follow-up was 81.4% ± 9%. CONCLUSION: Early results of the SICP registry on transcatheter Melody pulmonary valve implantation show that the procedure is safe and successful. Major concerns are related to the occurrence of stent fracture and bacterial endocarditis. Longer follow-up and larger series are needed.


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar/terapia , Estenose da Valva Pulmonar/terapia , Adolescente , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Criança , Remoção de Dispositivo , Ecocardiografia Doppler em Cores , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/cirurgia , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Itália , Estimativa de Kaplan-Meier , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico , Insuficiência da Valva Pulmonar/mortalidade , Estenose da Valva Pulmonar/diagnóstico , Estenose da Valva Pulmonar/mortalidade , Sistema de Registros , Sociedades Médicas , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
12.
Catheter Cardiovasc Interv ; 78(1): 84-90, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21234922

RESUMO

OBJECTIVES: The aim of this article is to report a 16-year experience with percutaneous balloon aortic valvuloplasty (BAVP) in newborns and young infants up to 3 months of age in a tertiary care cardiac reference center in a developing country and to determine its value in postponing open heart surgery. BACKGROUND: Congenital aortic stenosis (AS) is a potentially life threatening disorder. BAVP and surgical procedures have similar short and medium-term efficacy. METHODS: Thirty-one consecutive newborns and young infants with critical AS underwent BAVP in our department from 1991 to 2007. Mean patient age at time of the procedure was 22 days (range 2-92 days) and mean weight was 3,310 g (1,840-4,400 g). RESULTS: There was a significant reduction in mean Doppler-derived peak gradient across the aortic valve immediately after the procedure (75.1 ± 22 versus 32.2 ± 13.02, P < 0.001), and this finding was maintained throughout follow-up. Since 2003, when the carotid approach became routine practice, no major vascular complications were observed. Mean time of follow-up was 81 months (5 days-196 months) with only two deaths (7.4%). Only 24% patients required surgical reintervention on the aortic valve during follow-up. Survival free from aortic valve surgery was 80% at 24 months, 66% at 63 months, and 50% at 80 months. CONCLUSION: Percutaneous intervention for relief of critical aortic stenosis in newborns in a tertiary center of a developing country is safe and has excellent short and long-term results comparable to other centers throughout the world.


Assuntos
Estenose da Valva Aórtica/terapia , Artérias Carótidas , Cateterismo/métodos , Artéria Femoral , Estenose da Valva Aórtica/congênito , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Brasil , Procedimentos Cirúrgicos Cardíacos , Cateterismo/efeitos adversos , Cateterismo/mortalidade , Países em Desenvolvimento , Intervalo Livre de Doença , Ecocardiografia Doppler , Feminino , Hemodinâmica , Mortalidade Hospitalar , Humanos , Lactente , Recém-Nascido , Estimativa de Kaplan-Meier , Masculino , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
13.
Echocardiography ; 28(7): 730-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21615485

RESUMO

To evaluate acute change of right and left ventricle after percutaneous closure of isolated atrial septal defect (ASD) 21 adult patients (13 F; 8 M) aged 28 ± 9.5 range 18-49 years have been examined by echocardiography before and 24 hours after percutaneous closure of ASD. Twenty-one normal adult subjects, as control group were included. A MyLab25 echo machine equipped with a multifrequency 2.5-3.5 MHz transducer was used. Offline computer-based analysis for strain and SR were performed using XStrain software based on a feature tracking algorithm. All patients had ASD OS2 with right ventricular dilatation and diastolic areas were larger than in controls: P = 0.0158. Global right ventricular longitudinal strain was higher P = 0.0438. Twenty-four hours after ASD closure, right ventricular diastolic and systolic areas were significantly reduced. Right ventricular global longitudinal systolic strain decreased: P = 0.00016, as well as global right ventricular longitudinal SR -1.56/sec ± 0.57 vs. -1.28/sec ± 0.31, P = 0.02646. At the mean time left ventricular end diastolic volume and left ventricular cardiac output measured by two-dimensional echocardiography both increased significantly P = 0.002145 and 0.013409. Global circumferential strain at mitral level augmented significantly -20.3%± 4.64 vs. -25.39%± 5.22, P = 0.00003. Longitudinal strain of the right ventricle works as indicator of right ventricular function dependent on loading conditions while SR seems to be less dependent on it. Circumferential strain could be used as an indicator of left ventricular response to normalized loading conditions.


Assuntos
Ecocardiografia/métodos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Comunicação Interatrial/cirurgia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Adolescente , Adulto , Algoritmos , Estudos de Casos e Controles , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Software , Estatísticas não Paramétricas , Resultado do Tratamento
14.
J Matern Fetal Neonatal Med ; 34(4): 547-554, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31106637

RESUMO

Objective: To analyze the more recent outcomes of fetuses with different laterality defects.Material and methods: Out of 1508 fetuses with congenital heart disease (CHD) diagnosed by echocardiography between January 1995 and December 2015, 94 (6.3%) presented abnormal visceroatrial situs: 42 till December 2002 (group 1, analyzed retrospectively) and 52 since then until December 2015 (group 2, analyzed prospectively). Twenty-one had left isomerism (Lisom), 22 right isomerism (Risom), 16 situs inversus- dextrocardia (SVI-dx), 5 situs inversus- levocardia (SVI-levo), and 30 situs solitus-dextrocardia (SSol-dx).Results: Seventy-six cases (81%) had CHD, more frequently complex atrioventricular defect. Eighteen cases showed normal heart: half of subgroups SVI-dx and SVI-levo, a third of SSol-dx. Postoperative mortality in continuing pregnancy in group 2 was 43.7 versus 40% in group 1, lower in SVs-dx (0 versus 50%) and Lisom (33.3 versus 66.7%), worse in Risom (71.4 versus 25%). Total mortality in group 2 was 48.3 versus 55% in group 1, better in Ssol-dx (37.5 versus 50%) and in Lisom (27.4 versus 71.4%). In isolated forms all but one case are alive.Conclusions: Our fetal cases presented a relevant mortality in both periods. The outcomes were slightly better in a more recent era in SSol and Lisom.What is known about this topic?Out of laterality defects, the heterotaxies (i.e. left and right isomerism) are known to be associated to a relevant mortality in fetal and neonatal cases.Heterotaxies have a variable position of the heart, but some authors evaluated only those with dextrocardia in their studies on different laterality defects.Controversial data are presented in the literature for the outcomes of fetuses with laterality defects. Many large studies analyzed the data of a very long time period in which it is opinable to compare the results of the treatment, because of a recent improved management and surgical techniques.What does this study add?Our study presents an experience of a single center with cases of different types of laterality defects observed during a routine fetal echocardiography, not only heterotaxies.The knowledge of different laterality defects and of their characteristics (association with cardiac and extracardiac anomalies or with normal heart) is useful for the prenatal counseling.We compare the postoperative and total mortality in more recent period (since 2003) with respect to the previous era (1995-2002).


Assuntos
Cardiopatias Congênitas , Síndrome de Heterotaxia , Situs Inversus , Ecocardiografia , Feminino , Feto , Cardiopatias Congênitas/diagnóstico por imagem , Síndrome de Heterotaxia/diagnóstico por imagem , Síndrome de Heterotaxia/epidemiologia , Humanos , Recém-Nascido , Gravidez , Estudos Retrospectivos
15.
Catheter Cardiovasc Interv ; 75(2): 246-55, 2010 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-19908328

RESUMO

BACKGROUND: The incidence of residual ventricular septal defects (VSDs) after surgery is 5-25%. Redo surgery is associated with higher risks. METHODS: Between January 2000 to December 2008, 170 patients underwent percutaneous VSD closure in our centre: 22(16M) of these had 23 closures for residual VSDs. Median age was 32.5 yrs (1.4-79). All patients had echocardiographic signs of left ventricle volume overload (Q(p)/Q(s) >or= 1.5). Nine patients had previous VSD closure, 6 tetralogy of Fallot repair, and 7, other procedures. There were 15 muscular, 6 perimembranous and 2 apical VSDs. RESULTS: Amplatzer VSD devices were used in all. Median VSD size was 8 mm (4.3-16). Median fluoroscopy time was 33 minutes (15-130). There were three adverse events: 1 ventricular fibrillation requiring DC cardioversion; 1 transient complete atrio-ventricular block reverting to sinus rhythm at 24-hours; one patient had transient atrial flutter during the procedure. All procedures were successful; no additional procedures were required. Trivial residual shunts were seen in 3 patients at follow-up. There were no late events. One patient experienced arrhythmic death 5-yrs after procedure. One patient was reoperated due to dehiscence of VSD patch 2-yrs after the second successful percutaneous closure. CONCLUSIONS: Transcatheter closure of postsurgical residual VSD is safe and efficacious management option and obviates the need for further surgery and by-pass.


Assuntos
Cateterismo Cardíaco , Comunicação Interventricular/terapia , Procedimentos Cirúrgicos Vasculares , Adolescente , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Criança , Pré-Escolar , Ecocardiografia Transesofagiana , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Humanos , Lactente , Modelos Logísticos , Pessoa de Meia-Idade , Razão de Chances , Modelos de Riscos Proporcionais , Desenho de Prótese , Radiografia , Reoperação , Medição de Risco , Dispositivo para Oclusão Septal , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Adulto Jovem
16.
J Cardiovasc Med (Hagerstown) ; 21(9): 654-659, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32740498

RESUMO

OBJECTIVE: By the end of February 2020, the COVID-19 pandemic infection had spread in Northern Italy, with thousands of patients infected. In Lombardy, the most affected area, the majority of public and private hospitals were dedicated to caring for COVID-19 patients and were organized following the 'Hub-and-Spoke' model for other medical specialties, like cardiac surgery and interventional procedures for congenital cardiac disease (CHD). Here, we report how the congenital cardiac care system was modified in Lombardy and the first results of this organization. METHODS: We describe a modified 'Hub-and-Spoke' model - that involves 59 birthplaces and three specialized Congenital Cardiac Centers -- and how the hub center organized his activity. We also reported the data of the consecutive cases hospitalized during this period. RESULTS: From 9 March to 15 April, we performed: a total of 21 cardiac surgeries, 4 diagnostic catheterizations, 3 CT scans, and 2 CMR. In three cases with prenatal diagnosis, the birth was scheduled. The spoke centers referred to our center six congenital cardiac cases. The postop ExtraCorporeal Membrane Oxygenation support was required in two cases; one case died. None of these patients nor their parents or accompanying person was found to be COVID-19-positive; 2 pediatric intensivists were found to be COVID-19-positive, and needed hospitalization without mechanical ventilation; 13 nurses had positive COVID swabs (4 with symptoms), and were managed and isolated at home. CONCLUSION: Our preliminary data suggest that the model adopted met the immediate needs with a good outcome without increased mortality, nor COVID-19 exposure for the patients who underwent procedures.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Serviço Hospitalar de Cardiologia , Infecções por Coronavirus , Cardiopatias Congênitas , Controle de Infecções , Pandemias , Assistência Perinatal , Pneumonia Viral , Betacoronavirus/isolamento & purificação , COVID-19 , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Serviço Hospitalar de Cardiologia/organização & administração , Serviço Hospitalar de Cardiologia/tendências , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/prevenção & controle , Feminino , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/cirurgia , Humanos , Recém-Nascido , Controle de Infecções/métodos , Controle de Infecções/organização & administração , Itália/epidemiologia , Masculino , Modelos Organizacionais , Inovação Organizacional , Pandemias/prevenção & controle , Assistência Perinatal/métodos , Assistência Perinatal/organização & administração , Pneumonia Viral/epidemiologia , Pneumonia Viral/prevenção & controle , Cuidados Pós-Operatórios/métodos , Gravidez , SARS-CoV-2
17.
J Cardiovasc Med (Hagerstown) ; 20(4): 253-260, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30676496

RESUMO

AIMS: The aim of this study was to assess the impact of a transition clinic model on adolescent congenital heart disease (CHD) patients' health perception outcomes. The transition clinic model consists of multidisciplinary standardized interventions to educate and support CHD patients and represents a key element in the adequate delivery of care to these individuals during their transition from childhood to adulthood. Currently, empirical data regarding the impact of transition clinic models on the improvement of health perceptions in CHD adolescent patients are lacking. METHODS: A quasi-experimental design was employed. Quality of life, satisfaction, health perceptions and knowledge were assessed at the time of enrolment (T0) and a year after enrolment (T1), respectively. During the follow-up period, the patients enrolled (aged 11-18 years) were involved in the CHD-specific transition clinic model (CHD-TC). RESULTS: A sample of 224 CHD adolescents was enrolled (60.7% boys; mean age: 14.84 ±â€Š1.78 years). According to Warnes' classification, 22% of patients had simple heart defect, 56% showed moderate complexity and 22% demonstrated severe complexity. The overall results suggested a good impact of the CHD-TC on adolescents' outcomes, detailing in T1 the occurrence of a reduction of pain (P < 0.001) and anxiety (P < 0.001) and an improvement of knowledge (P < 0.001), life satisfaction (P < 0.001), perception of health status (P < 0.001) and quality of life (P < 0.001). CONCLUSION: The CHD-TC seems to provide high-quality care to the patient by way of a multidisciplinary team. The results of the present study are encouraging and confirm the need to create multidisciplinary standardized interventions in order to educate and support the delivery of care for CHD adolescents and their families.


Assuntos
Comportamento do Adolescente , Serviços de Saúde do Adolescente/organização & administração , Comportamento Infantil , Serviços de Saúde da Criança/organização & administração , Prestação Integrada de Cuidados de Saúde/organização & administração , Comportamentos Relacionados com a Saúde , Conhecimentos, Atitudes e Prática em Saúde , Cardiopatias Congênitas/terapia , Transferência de Pacientes/organização & administração , Adaptação Psicológica , Adolescente , Fatores Etários , Criança , Feminino , Nível de Saúde , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/psicologia , Humanos , Masculino , Equipe de Assistência ao Paciente/organização & administração , Educação de Pacientes como Assunto/organização & administração , Participação do Paciente , Satisfação do Paciente , Percepção , Qualidade de Vida
18.
Am Heart J ; 156(4): 706-12, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18926151

RESUMO

BACKGROUND: Percutaneous closure of atrial septal defect (ASD) is a valid alternative to surgical approach. Current device has significantly improved the success rate also in complex cases. The aim of this study is to assess the impact of age, defect size, and morphologic features on successfully percutaneous ASD closure. METHODS: Between January 2000 and September 2004, 1,013 consecutive patients underwent closure of an isolated type II ASD at our institution. The following outcomes have been evaluated: (1) role of percutaneous ASD closure as alternative to surgical repair, in current daily practice; (2) impact of age on the selected closure approach; (3) analysis of morphologic variety of ASD and its effect on the closure technique; (4) possible role of specific device selection according to ASD morphology to improve procedural success. RESULTS: During the study period, up to 80% of secundum ASDs were suitable for percutaneous closure with the currently available devices. Need for surgical ASD closure was more common in pediatric patients, likely reflecting the more frequent diagnosis of larger and complex defects at a young age. Accurate ADS morphology assessment and appropriate device selection are key elements to obtain procedural success. In particular, among all the ASD characteristics, the rim absence is the main limiting factor to a successful percutaneous ASD closure. A trend of reduction in peri-procedural adverse events was observed during the study period, with complications needing immediate cardiac surgery occurred only in 1% of cases. CONCLUSIONS: Percutaneous ASD closure is feasible and associated with low complication rate. A thorough analysis of morphologic aspects is mandatory in order to select the appropriate device and the optimal approach. Surgical closure remains the treatment of choice in selected patients.


Assuntos
Comunicação Interatrial/patologia , Comunicação Interatrial/terapia , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Angiografia Coronária , Ecocardiografia Transesofagiana , Feminino , Comunicação Interatrial/diagnóstico por imagem , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Próteses e Implantes , Desenho de Prótese , Resultado do Tratamento
19.
G Ital Cardiol (Rome) ; 19(6): 386-393, 2018 Jun.
Artigo em Italiano | MEDLINE | ID: mdl-29912228

RESUMO

BACKGROUND: The multidisciplinary standardized interventions to educate and support patients with congenital heart disease (CHD) are described as "Transition Clinic" (TC). TC represents a key element to deliver care for patients during the transition from childhood to adulthood. So far, there is a lack of empirical evidence regarding the impact of TC models on the improvement of health perception in adolescent patients with CHD (CHD-specific TC model). For this reason, the aim of this study is assess the impact of the TC model on CHD adolescent patients' health perception outcomes. METHODS: This study has a quasi-experimental design. Quality of life, satisfaction and health perception were assessed in T0 and after 1 year from enrollment (T1). During the follow-up period, the patients enrolled (aged 14 to 21 years) were involved in the CHD-specific TC model. RESULTS: The results are referred to the first 100 patients enrolled (mean age 14.79 ± 1.85 years; 60% male), as they have already completed the follow-up. The overall study is currently ongoing. According to Warnes' classification, 29% of patients had simple heart defects, 46% showed moderate complexity, and 25% showed severe complexity. The comparison between T0 and T1 showed statistically significant improvement in T1 regarding pain/discomfort, anxiety/depression and perception of health status (EQ-5D), general satisfaction and quality of life (LAS QoL). CONCLUSIONS: The preliminary results showed in this study are encouraging, and confirm the need to create a multidisciplinary standardized intervention of education and support to deliver care for adolescent patients with CHD.


Assuntos
Nível de Saúde , Cardiopatias Congênitas/epidemiologia , Qualidade de Vida , Cuidado Transicional/organização & administração , Adolescente , Atenção à Saúde/organização & administração , Feminino , Seguimentos , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/psicologia , Humanos , Comunicação Interdisciplinar , Masculino , Educação de Pacientes como Assunto/métodos , Satisfação do Paciente , Índice de Gravidade de Doença , Inquéritos e Questionários , Adulto Jovem
20.
Am Heart J ; 154(4): 795-800, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17893011

RESUMO

BACKGROUND: There are limited data in the literature about the use of covered stent in patients with aortic coarctation. METHODS: Between January 2004 and September 2006, we implanted covered Cheatham-Platinum stents in 33 patients with complex aortic coarctation (23 men, median age 13 years, range 6-66 years). Twenty subjects had native aortic coarctation, whereas 13 had recoarctation. All procedures were performed under general anesthesia and orotracheal intubation. RESULTS: The stents used ranged from 22 to 45 mm in length. The mean fluoroscopy and procedure times were 14 +/- 6 and 74 +/- 15 minutes, respectively. After implantation, the gradient across the stenosis decreased significantly (pre stent: median value 39 mm Hg [range 20-75 mm Hg] vs post stent: median value 0 mm Hg [range 0-12 mm Hg] [P < .0001]). Vessel diameter increased from a median value of 5 mm (range 0-11) to a median value of 15 mm (range 10-25) (P < .0001). The stents were placed in the correct position in all subjects. No complications occurred, and on angiographic control, the stenoses had been relieved and the aneurysms completely excluded. During a median follow-up of 12 months (1-40 months), the results were stable without complications. One patient developed intrastent restenosis due to a significant endothelial proliferation that was successfully treated by high-pressure balloon angioplasty. CONCLUSIONS: Covered Cheatham-Platinum stents are promising tools for the treatment of complex aortic coarctation.


Assuntos
Coartação Aórtica/cirurgia , Stents , Adolescente , Adulto , Angioplastia com Balão , Coartação Aórtica/complicações , Criança , Aneurisma Coronário/complicações , Aneurisma Coronário/cirurgia , Feminino , Fluoroscopia , Humanos , Intubação Intratraqueal , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Recidiva , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA