Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 2024 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-39299922

RESUMO

BACKGROUND AND AIMS: Prophylactic implantable cardioverter-defibrillators (ICDs) are not recommended until left ventricular ejection fraction (LVEF) has been reassessed 40 to 90 days after an acute myocardial infarction. In the current therapeutic era, the prognosis of sustained ventricular arrhythmias (VAs) occurring during this early post-infarction phase (i.e. within 3 months of hospital discharge) has not yet been specifically evaluated in post-myocardial infarction patients with impaired LVEF. Such was the aim of this retrospective study. METHODS: Data analysis was based on a nationwide registry of 1032 consecutive patients with LVEF ≤ 35% after acute myocardial infarction who were implanted with an ICD after being prescribed a wearable cardioverter-defibrillator (WCD) for a period of 3 months upon discharge from hospital after the index infarction. RESULTS: ICDs were implanted either because a sustained VA occurred while on WCD (VA+/WCD, n = 72) or because LVEF remained ≤35% at the end of the early post-infarction phase (VA-/WCD, n = 960). The median follow-up was 30.9 months. Sustained VAs occurred within 1 year after ICD implantation in 22.2% and 3.5% of VA+/WCD and VA-/WCD patients, respectively (P < .0001). The adjusted multivariable analysis showed that sustained VAs while on WCD independently predicted recurrence of sustained VAs at 1 year (adjusted hazard ratio [HR] 6.91; 95% confidence interval [CI] 3.73-12.81; P < .0001) and at the end of follow-up (adjusted HR 3.86; 95% CI 2.37-6.30; P < .0001) as well as 1-year mortality (adjusted HR 2.86; 95% CI 1.28-6.39; P = .012). CONCLUSIONS: In patients with LVEF ≤ 35%, sustained VA during the early post-infarction phase is predictive of recurrent sustained VAs and 1-year mortality.

2.
Int J Mol Sci ; 25(17)2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39273588

RESUMO

Our research explores leucine-based pseudo-proteins (LPPs) for advanced wound dressings, focusing on their effects on wound healing in an in vitro model. We assessed three types of LPP films for their ability to enhance wound closure rates and modulate cytokine production. They all significantly improved wound closure compared to traditional methods, with the 8L6 and copolymer films showing the most pronounced effects. Notably, the latter exhibited an optimal cytokine profile: an initial burst of pro-inflammatory TNF-α, followed by a controlled release of IL-6 during the proliferative phase and a significant increase in anti-inflammatory IL-10 during remodeling. This balanced cytokine response suggests that the copolymer film not only accelerates wound closure but also supports a well-regulated healing process, potentially reducing fibrosis and abnormal scarring, underscoring the potential of copolymer LPPs as advanced wound dressing materials. Future research will aim to elucidate the specific signaling pathways activated by the copolymer LPP to better understand its mechanism of action. Overall, LPP films offer a promising approach to improving wound care and could lead to more effective treatments for complex wounds.


Assuntos
Leucina , Cicatrização , Cicatrização/efeitos dos fármacos , Leucina/farmacologia , Humanos , Bandagens , Citocinas/metabolismo , Animais
3.
Anal Chem ; 95(9): 4395-4403, 2023 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-36788139

RESUMO

Cell heterogeneity is a crucial parameter for understanding the complexity of numerous biomedical issues. Trajectory inference-based approaches are recent tools developed for single-cell transcriptomics (scRNA-seq) data analysis. They aim to reconstruct evolving pathways from the variety of cell states that coexist simultaneously in a cell population. We propose to expand this concept to Raman spectroscopy, a label-free modality that probes the global molecular nature of a sample, by investigating the dynamics of adipocyte differentiation.


Assuntos
Perfilação da Expressão Gênica , Análise de Célula Única , Análise de Célula Única/métodos , Perfilação da Expressão Gênica/métodos , Diferenciação Celular , Análise Espectral Raman , Análise de Sequência de RNA/métodos
4.
Analyst ; 148(16): 3909-3917, 2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37466305

RESUMO

Colorectal cancer is a global public health problem with one of the highest death rates. It is the second most deadly type of cancer and the third most frequently diagnosed in the world. The present study focused on metastatic colorectal cancer (mCRC) patients who had been treated with chemotherapy-based regimen for which it remains uncertainty about the efficacy for all eligible patients. This is a major problem, as it is not yet possible to test different therapies in view of the consequences on the health of the patients and the risk of progression. Here, we propose a method to predict the efficacy of an anticancer treatment in an individualized way, using a deep learning model constructed on the retrospective analysis of the primary tumor of several patients. Histological sections from tumors were imaged by standard hematoxylin and eosin (HE) staining and infrared spectroscopy (IR). Images obtained were then processed by a convolutional neural network (CNN) to extract features and correlate them with the subsequent progression-free survival (PFS) of each patient. Separately, HE and IR imaging resulted in a PFS prediction with an error of 6.6 and 6.3 months respectively (28% and 26% of the average PFS). Combining both modalities allowed to decrease the error to 5.0 months (21%). The inflammatory state of the stroma seemed to be one of the main features detected by the CNN. Our pilot study suggests that multimodal imaging analyzed with deep learning methods allow to give an indication of the effectiveness of a treatment when choosing.


Assuntos
Neoplasias do Colo , Neoplasias Colorretais , Aprendizado Profundo , Neoplasias Retais , Humanos , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/diagnóstico , Projetos Piloto , Estudos Retrospectivos , Coloração e Rotulagem
5.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37021342

RESUMO

AIMS: While elevated resting heart rate measured at a single point of time has been associated with cardiovascular outcomes, utility of continuous monitoring of nocturnal heart rate (NHR) has never been evaluated. We hypothesized that dynamic NHR changes may predict, at short term, impending cardiovascular events in patients equipped with a wearable cardioverter-defibrillator (WCD). METHODS AND RESULTS: The WEARIT-France prospective cohort study enrolled heart failure patients with WCD between 2014 and 2018. Night-time was defined as midnight to 7 a.m. NHR initial trajectories were classified into four categories based on mean NHR in the first week (High/Low) and NHR evolution over the second week (Up/Down) of WCD use. The primary endpoint was a composite of cardiovascular death and heart failure hospitalization. A total of 1013 [61 (interquartile range, IQR 53-68) years, 16% women, left ventricular ejection fraction 26% (IQR 22-30)] were included. During a median WCD wear duration of 68 (IQR 44-90) days, 58 patients (6%) experienced 69 events. After considering potential confounders, High-Up NHR trajectory was significantly associated with the primary endpoint compared to Low-Down [adjusted hazard ratio (HR) 6.08, 95% confidence interval (CI) 2.56-14.45, P < 0.001]. Additionally, a rise of >5 bpm in weekly average NHR from the preceding week was associated with 2.5 higher composite event risk (HR 2.51, 95% CI 1.22-5.18, P = 0.012) as well as total mortality (HR 11.21, 95% CI 3.55-35.37, P < 0.001) and cardiovascular hospitalization (HR 2.70, 95% CI 1.51-4.82, P < 0.001). CONCLUSION: Dynamic monitoring of NHR may allow timely identification of impending cardiovascular events, with the potential for 'pre-emptive' action. REGISTRATION NUMBER: Clinical Trials.gov Identifier: NCT03319160.


Assuntos
Insuficiência Cardíaca , Dispositivos Eletrônicos Vestíveis , Humanos , Feminino , Masculino , Estudos de Coortes , Frequência Cardíaca , Estudos Prospectivos , Volume Sistólico/fisiologia , Função Ventricular Esquerda , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Desfibriladores
6.
Anal Chem ; 94(46): 16050-16059, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-36346912

RESUMO

Dimensional reduction of highly multidimensional datasets such as those acquired by Fourier transform infrared spectroscopy (FTIR) is a critical step in the data analysis workflow. To achieve this goal, numerous feature selection methods have been developed and applied in a supervised context, i.e., using a priori knowledge about data usually in the form of labels for classification or quantitative values for regression. For this, genetic algorithms have been largely exploited due to their flexibility and global optimization principle. However, few applications in an unsupervised context have been reported in infrared spectroscopy. The aim of this article is to propose a new unsupervised feature selection method based on a genetic algorithm using a validity index computed from KMeans partitions as a fitness function. Evaluated on a simulated dataset and validated and tested on three real-world infrared spectroscopic datasets, our developed algorithm is able to find the spectral descriptors improving clustering accuracy and simplifying the spectral interpretation of results.


Assuntos
Algoritmos , Análise por Conglomerados , Espectroscopia de Infravermelho com Transformada de Fourier , Espectrofotometria Infravermelho
7.
Circ Res ; 127(2): 301-309, 2020 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-32833581

RESUMO

Emerging evidence suggests that atrial fibrillation (AF) may be associated with an increased risk of sudden cardiac death (SCD). However, AF shares risk factors with numerous cardiac conditions, including coronary heart disease and heart failure-the 2 most common substrates for SCD-making the AF-SCD relationship particularly challenging to address. A careful consideration of confounding factors is essential, since interventions for AF will be effective in reducing SCD only if there is a causal association between these 2 conditions. In this translational review, we detail the plausible underlying pathophysiological mechanisms through which AF may promote or lead to SCD, as well as the existing epidemiological evidence supporting an association between AF and SCD. While the role of AF in predicting SCD in the general population appears limited and not established, AF might be integrated to improve risk stratification in some specific phenotypes. Optimal AF management, including that of its associated conditions, appears to be of interest to prevent AF-related SCD, especially because the AF-SCD relationship is in part driven by heart failure.


Assuntos
Fibrilação Atrial/etiologia , Morte Súbita Cardíaca/etiologia , Fibrilação Atrial/epidemiologia , Morte Súbita Cardíaca/epidemiologia , Humanos
8.
Europace ; 24(2): 202-210, 2022 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-34374759

RESUMO

AIMS: The 4S-AF scheme [Stroke risk, Symptom severity, Severity of atrial fibrillation (AF) burden, Substrate severity] has recently been described as a novel approach to in-depth characterization of AF. We aim to determine if the 4S-AF scheme would be useful for AF characterization and provides prognostic information in real-world AF patients. METHODS AND RESULTS: The Spanish and French cohorts of the EORP-AF Long-Term General Registry were included. The baseline 4S-AF scheme was calculated and related to the primary management strategy (rhythm or rate control). Follow-up was performed at 1-year with all-cause mortality and the composite of ischaemic stroke/transient ischaemic attack/systemic embolism, major bleeding, and all-cause death, as primary endpoints. A total of 1479 patients [36.9% females, median age 72 interquartile range (IQR 64-80) years] were included. The median 4S-AF scheme score was 5 (IQR 4-7). The 4S-AF scheme, as continuous and as categorical, was associated with the management strategy decided for the patient (both P < 0.001). The predictive performances of the 4S-AF scheme for the actual management strategy were appropriate in its continuous [c-index 0.77, 95% confidence interval (CI) 0.75-0.80] and categorical (c-index 0.75, 95% CI 0.72-0.78) forms. Cox regression analyses showed that 'red category' classified patients in the 4S-AF scheme had a higher risk of all-cause death (aHR 1.75, 95% CI 1.02-2.99) and composite outcomes (aHR 1.60, 95% CI 1.05-2.44). CONCLUSION: Characterization of AF by using the 4S-AF scheme may aid in identifying AF patients that would be managed by rhythm or rate control and could also help in identifying high-risk AF patients for worse clinical outcomes in a 'real-world' setting.


Assuntos
Fibrilação Atrial , Isquemia Encefálica , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle
9.
Int J Cosmet Sci ; 44(5): 588-601, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35916243

RESUMO

OBJECTIVE: The objective of our research was to investigate the heat-protecting effect of a product ex vivo and in vivo on human hair fibres. METHODS: A preparatory study was carried out in order to determine an optimal threshold of thermal stress. For this, the structure of cross-sections of the hair fibre was observed by optical microscopy. Then, Scanning Electron Microscopy (SEM) and Confocal Raman Spectroscopy (CRS) were applied to analyse ex vivo and in vivo morphological and molecular damage in hair structure after heat stress. Finally, in vivo tests were used to collect consumer perception. RESULTS: The preparatory study enabled us to determine an optimal stress threshold of 10 heating cycle for SEM and 5 heating cycle for CRS. Based on spectral hierarchical classification using Ward's clustering algorithm, the ex vivo Raman results show that the spectral signature of the hair treated and heated is very close to the negative control. This shows that the product preserves the keratin structure after thermal stress. These results were also confirmed by an in vivo Raman analysis performed on hair samples from 5 donors. In concordance with Raman results, SEM shows that treated hair presents lesser "bubbles" and "crackling" on the hair surface. Finally, the in vivo studies proved that hair was more protected from heat. CONCLUSION: The authors concluded that the product shows protective properties with respect to morphological and molecular heat damage. We also demonstrate that the product promotes the α-helix keratin conformation and preserves the S-S disulfide bands.


OBJECTIF: L'objectif de notre étude est d'évaluer ex vivo et in vivo l'effet thermoprotecteur d'un produit sur les fibres capillaires humaines. MÉTHODES: Une étude préparatoire a été réalisée afin de déterminer un seuil optimal du stress thermique. Pour cela, la structure des coupes transversales des cheveux a été observée par microscopie optique. Ensuite, la microscopie électronique à balayage (MEB) et la spectroscopie confocale Raman (SCR) ont été appliquées pour analyser les dommages morphologiques et moléculaires (ex vivo et in vivo) de la structure du cheveu après un stress thermique. Enfin, des tests in vivo ont été réalisés pour recueillir la perception des consommateurs. RÉSULTATS: L'étude préparatoire nous a permis de déterminer un seuil de stress thermique optimal correspondant à 10 cycles de chauffage pour la MEB et 5 cycles de chauffage pour la SCR. Basés sur une classification hiérarchique utilisant l'algorithme de Ward, les résultats Raman « ex vivo ¼ montrent que la signature spectrale des cheveux traités et chauffés est très proche du témoin négatif. Cela montre que le produit préserve la structure de la kératine après un stress thermique. Ces résultats ont également été confirmés par une analyse Raman « in vivo ¼ réalisée sur des échantillons de cheveux de 5 donneurs. En concordance avec les résultats Raman, la MEB montre que les cheveux traités présentent moins de « bulles ¼ et de « craquelures ¼ à la surface des cheveux. Enfin, l'étude in vivo a prouvé que les cheveux sont mieux protégés de la chaleur. CONCLUSION: Les auteurs ont conclu que le produit présente des propriétés protectrices vis-à-vis des dommages thermiques morphologiques et moléculaires. Nous avons démontré également que le produit favorise la conformation de la kératine en hélice-α et préserve les bandes disulfures S-S.


Assuntos
Preparações para Cabelo , Queratinas Específicas do Cabelo , Cabelo/química , Humanos , Queratinas Específicas do Cabelo/análise , Microscopia Eletrônica de Varredura , Análise Espectral Raman/métodos
10.
Anal Chem ; 93(8): 3750-3761, 2021 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-33590761

RESUMO

The transfer of mid-infrared spectral histopathology to the clinic will be possible provided that its application in clinical practice is simple. Rapid analysis of formalin-fixed paraffin-embedded (FFPE) tissue section is thus a prerequisite. The chemical dewaxing of these samples before image acquisition used by the majority of studies is in contradiction with this principle. Fortunately, the in silico analysis of the images acquired on FFPE samples is possible using extended multiplicative signal correction (EMSC). However, the removal of pure paraffin pixels is essential to perform a relevant classification of tissue spectra. So far, this task was possible only if using manual and subjective histogram analysis. In this article, we thus propose a new automatic and multivariate methodology based on the analysis of optimized combinations of EMSC regression coefficients by validity indices and KMeans clustering to separate paraffin and tissue pixels. The validation of our method is performed using simulated infrared spectral images by measuring the Jaccard index between our partitions and the image model, with values always over 0.90 for diverse baseline complexity and signal-to-noise ratio. These encouraging results were also validated on real images by comparing our method with classical ones and by computing the Jaccard index between our partitions and the KMeans partitions obtained on the infrared image acquired on the same samples but after chemical dewaxing, with values always over 0.84.


Assuntos
Técnicas Histológicas , Parafina , Análise por Conglomerados , Formaldeído , Humanos , Inclusão em Parafina , Razão Sinal-Ruído , Espectroscopia de Infravermelho com Transformada de Fourier , Fixação de Tecidos
11.
Europace ; 23(3): 389-394, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33257986

RESUMO

AIMS: FRench Attitude reGistry in case of ICD LEad replacement (FRAGILE) registry was set-up to describe the attitude in different French institutions in case of implantable cardioverter-defibrillator (ICD) lead replacement, extraction, or abandonment and to compare outcomes in both groups. METHODS AND RESULTS: Prospective observational study comparing two attitudes in case of ICD lead replacement, extraction, or abandonment. Primary endpoint describes the attitude in different French centres, collect parameters that may influence the decision. Secondary endpoint compares early and mid-term (2 years) complications in both groups.Between April 2013 and April 2017, 552 patients were included in 32 centres. 434 (78.6%) were male, mean patient's age was 60.3 ± 14.4 years. In 56.9% of the cases, the decision was to explant the lead. Patients in the extraction group were younger than in the abandonment group (56.7 ± 14.5 vs. 65 ± 12.7 P < 0.0001) and less likely to have comorbidities (46.5% vs. 58.3% of the patients P = 0.022). The mean lead dwelling time was significantly longer in the abandonment group as compared with the extraction group (7.6 ± 3.9 vs. 5.2 ± 3.1 years, P < 0.0001). There was no statistical difference between both groups concerning early and 2 years complications. CONCLUSION: In this registry, the strategy in case of non-infected ICD lead replacement was mainly influenced by patient's age and comorbidities and lead dwelling time. No difference was observed in outcomes in both strategies.


Assuntos
Desfibriladores Implantáveis , Idoso , Atitude , Remoção de Dispositivo , Cardioversão Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros
12.
Europace ; 23(1): 73-81, 2021 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-33257972

RESUMO

AIMS: We aimed to provide contemporary real-world data on wearable cardioverter-defibrillator (WCD) use, not only in terms of effectiveness and safety but also compliance and acceptability. METHODS AND RESULTS: Across 88 French centres, the WEARIT-France study enrolled retrospectively patients who used the WCD between May 2014 and December 2016, and prospectively all patients equipped for WCD therapy between January 2017 and March 2018. All patients received systematic education session through a standardized programme across France at the time of initiation of WCD therapy and were systematically enrolled in the LifeVest Network remote services. Overall, 1157 patients were included (mean age 60 ± 12 years, 16% women; 46% prospectively): 82.1% with ischaemic cardiomyopathy, 10.3% after implantable cardioverter-defibrillator explant, and 7.6% before heart transplantation. Median WCD usage period was 62 (37-97) days. Median daily wear time of WCD was 23.4 (22.2-23.8) h. In multivariate analysis, younger age was associated with lower compliance [adjusted odds ratio (OR) 0.97, 95% confidence interval (CI) 0.95-0.99, P < 0.01]. A total of 18 participants (1.6%) received at least one appropriate shock, giving an incidence of appropriate therapy of 7.2 per 100 patient-years. Patient-response button allowed the shock to be aborted in 35.7% of well-tolerated sustained ventricular arrhythmias and in 95.4% of inappropriate ventricular arrhythmia detection, finally resulting in an inappropriate therapy in eight patients (0.7%). CONCLUSION: Our real-life findings reinforce previous studies on the efficacy and safety of the WCD in the setting of transient high-risk group in selected patients. Moreover, they emphasize the fact that when prescribed appropriately, in concert with adequate patient education and dedicated follow-up using specific remote monitoring system, compliance with WCD is high and the device well-tolerated by the patient.


Assuntos
Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Idoso , Estudos de Coortes , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
13.
Skin Res Technol ; 27(6): 1100-1109, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34114267

RESUMO

BACKGROUND: Monitoring the transcutaneous permeation of exogenous molecules using conventional techniques generally requires long pre-analytical preparation or labelling of samples. However, Raman spectroscopy is a label-free and non-destructive method which provides spatial distribution of tracked actives in skin. The aim of our study was to prove the interest of Raman imaging coupled with multivariate curve resolution alternating least square (MCR-ALS) analysis in monitoring retinol penetration into frozen and living human skin. MATERIALS AND METHODS: After topical treatment of skin samples by free or encapsulated retinol, thin cross sections were analysed by Raman imaging (up to 100 µm depth). Mann-Whitney test was used to identify retinol spectroscopic markers in skin. MCR-ALS was used to estimate retinol contribution in Raman spectral images. Heat maps were constructed to compare the distribution of free and encapsulated retinol in skin models. RESULTS: We identified the bands at 1158, 1196 and 1591 cm-1 as specific features for monitoring retinol in skin. Moreover, our MCR-ALS results showed an improvement of retinol penetration (up to 30 µm depth) with the encapsulated form as well as storage reservoir formation in stratum corneum, for each skin model. Finally, greater retinol penetration into living skin was observed. CONCLUSION: This study shows a proof of concept for the evaluation of retinol penetration in skin using Raman imaging coupled with MCR-ALS. This concept needs to be validated on more subjects to include inter-individual variability but also other factors affecting skin permeation (age, sex, pH, etc). Our study can be extended to other actives.


Assuntos
Pele , Vitamina A , Humanos , Análise dos Mínimos Quadrados , Análise Multivariada , Pele/diagnóstico por imagem , Análise Espectral Raman
14.
Anal Chem ; 92(5): 4053-4064, 2020 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-32045217

RESUMO

Surface-enhanced Raman scattering (SERS) is a powerful and sensitive technique for the detection of fingerprint signals of molecules and for the investigation of a series of surface chemical reactions. Many studies introduced quantitative applications of SERS in various fields, and several SERS methods have been implemented for each specific application, ranging in performance characteristics, analytes used, instruments, and analytical matrices. In general, very few methods have been validated according to international guidelines. As a consequence, the application of SERS in highly regulated environments is still considered risky, and the perception of a poorly reproducible and insufficiently robust analytical technique has persistently retarded its routine implementation. Collaborative trials are a type of interlaboratory study (ILS) frequently performed to ascertain the quality of a single analytical method. The idea of an ILS of quantification with SERS arose within the framework of Working Group 1 (WG1) of the EU COST Action BM1401 Raman4Clinics in an effort to overcome the problematic perception of quantitative SERS methods. Here, we report the first interlaboratory SERS study ever conducted, involving 15 laboratories and 44 researchers. In this study, we tried to define a methodology to assess the reproducibility and trueness of a quantitative SERS method and to compare different methods. In our opinion, this is a first important step toward a "standardization" process of SERS protocols, not proposed by a single laboratory but by a larger community.

15.
Analyst ; 145(8): 2945-2957, 2020 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-32110793

RESUMO

Raman spectroscopy is a candidate technique for diagnosis applications in medicine due to its high molecular specificity. Optimizing the pre-treatment applied for Raman data is important for exploiting Raman signals and ensuring their relevance in medical diagnosis. One of the crucial steps in data pre-processing, normalization, can affect significantly the result interpretation. To select the appropriate normalization method, a strategy based on validity indices (VI) is proposed in this study. VI are based on measuring the quality of data partitioning without involving a full sequence of supervised classification. The approach was tested on Raman data acquired from control and in vitro glycated proteins (albumin and collagen). Protein glycation is a process involved in the molecular ageing of tissues that leads to the formation of products altering the functional and structural properties of proteins. Different methods of normalization were applied on the data sets: integrated intensity of the phenylalanine band, integrated intensity of the amide I band, standard normal variate (SNV), multiplicative signal correction (MSC), and extended multiplicative signal correction (EMSC) that performs simultaneously baseline correction and normalization. Following normalization, principal component analysis (PCA) was applied and VI were calculated from PCA scores resulting from each of the normalization methods mentioned. Based on VI quantitative values, our experiments permit to illustrate the effect of normalization on the data separability of control and glycated samples, and to determine the most appropriate normalization and simultaneously the most discriminant principal components to exploit vibrational information associated with glycation-induced modifications. In parallel, principal component analysis - linear discriminant analysis (PCA-LDA) was carried out for positioning the interest of VI in regard to a common chain of data processing.


Assuntos
Colágeno Tipo I/análise , Produtos Finais de Glicação Avançada/análise , Albumina Sérica Humana/análise , Animais , Análise Discriminante , Humanos , Análise de Componente Principal , Ratos , Análise Espectral Raman
16.
Analyst ; 145(8): 3157, 2020 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-32202269

RESUMO

Correction for 'Towards normalization selection of Raman data in the context of protein glycation: application of validity indices to PCA processed spectra' by Fatima Alsamad et al., Analyst, 2020, DOI: 10.1039/c9an02155h.

17.
Analyst ; 145(13): 4699-4700, 2020 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-32490439

RESUMO

Correction for 'Confocal Raman microspectroscopy for skin characterization: a comparative study between human skin and pig skin' by Sana Tfaili et al., Analyst, 2012, 137, 3673-3682, DOI: .

18.
Eur Heart J ; 40(26): 2121-2127, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31046090

RESUMO

AIMS: The very long-term outcome of patients who survive the first few years after receiving cardiac resynchronization therapy (CRT) has not been well described thus far. We aimed to provide long-term outcomes, especially with regard to the occurrence of sudden cardiac death (SCD), in CRT patients without (CRT-P) and with defibrillator (CRT-D). METHODS AND RESULTS: A total of 1775 patients, with ischaemic or non-ischaemic dilated cardiomyopathy, who were alive 5 years after CRT implantation, were enrolled in this multicentre European observational cohort study. Overall long-term mortality rates and specific causes of death were assessed, with a focus on late SCD. Over a mean follow-up of 30 months (interquartile range 10-42 months) beyond the first 5 years, we observed 473 deaths. The annual age-standardized mortality rates of CRT-D and CRT-P patients were 40.4 [95% confidence interval (CI) 35.3-45.5] and 97.2 (95% CI 85.5-109.9) per 1000 patient-years, respectively. The adjusted hazard ratio (HR) for all-cause mortality was 0.99 (95% CI 0.79-1.22). Twenty-nine patients in total died of late SCD (14 with CRT-P, 15 with CRT-D), corresponding to 6.1% of all causes of death in both device groups. Specific annual SCD rates were 8.5 and 5.8 per 1000 patient-years in CRT-P and CRT-D patients, respectively, with no significant difference between groups (adjusted HR 1.0, 95% CI 0.45-2.44). Death due to progressive heart failure represented the principal cause of death (42.8% in CRT-P patients and 52.6% among CRT-D recipients), whereas approximately one-third of deaths in both device groups were due to non-cardiovascular death. CONCLUSION: In this first description of very long-term outcomes among CRT recipients, progressive heart failure death still represented the most frequent cause of death in patients surviving the first 5 years after CRT implant. In contrast, SCD represents a very low proportion of late mortality irrespective of the presence of a defibrillator.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Morte Súbita Cardíaca/epidemiologia , Idoso , Estudos de Coortes , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Fatores de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Fatores de Tempo
19.
Molecules ; 25(18)2020 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-32927716

RESUMO

Saliva is a biofluid that can be considered as a "mirror" reflecting our body's health status. Vibrational spectroscopy, Raman and infrared, can provide a detailed salivary fingerprint that can be used for disease biomarker discovery. We propose a systematic literature review based on the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines to evaluate the potential of vibrational spectroscopy to diagnose oral and general diseases using saliva as a biological specimen. Literature searches were recently conducted in May 2020 through MEDLINE-PubMed and Scopus databases, without date limitation. Finally, over a period of 10 years, 18 publications were included reporting on 10 diseases (three oral and seven general diseases), with very high diagnostic performance rates in terms of sensitivity, specificity, and accuracy. Thirteen articles were related to six different cancers of the following anatomical sites: mouth, nasopharynx, lung, esophagus, stomach, and breast. The other diseases investigated and included in this review were periodontitis, Sjögren's syndrome, diabetes, and myocardial infarction. Moreover, most articles focused on Raman spectroscopy (n = 16/18) and more specifically surface-enhanced Raman spectroscopy (n = 12/18). Interestingly, vibrational spectroscopy appears promising as a rapid, label-free, and non-invasive diagnostic salivary biometric tool. Furthermore, it could be adapted to investigate subclinical diseases-even if developmental studies are required.


Assuntos
Biomarcadores , Biometria , Técnicas de Diagnóstico Molecular , Saliva/química , Análise Espectral Raman , Animais , Biometria/métodos , Humanos , Metabolômica/métodos , Sensibilidade e Especificidade , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral Raman/métodos
20.
Europace ; 21(7): 1063-1069, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30891608

RESUMO

AIMS: Current guidelines do not propose any age cut-off for the primary prevention implantable cardioverter-defibrillator (ICD). However, the risk/benefit balance in the very elderly population has not been well studied. METHODS AND RESULTS: In a multicentre French study assessing patients implanted with an ICD for primary prevention, outcomes among patients aged ≥80 years were compared with <80 years old controls matched for sex and underlying heart disease (ischaemic and dilated cardiomyopathy). A total of 300 ICD recipients were enrolled in this specific analysis, including 150 patients ≥80 years (mean age 81.9 ± 2.0 years; 86.7% males) and 150 controls (mean age 61.8 ± 10.8 years). Among older patients, 92 (75.6%) had no more than one associated comorbidity. Most subjects in the elderly group got an ICD as part of a cardiac resynchronization therapy procedure (74% vs. 46%, P < 0.0001). After a mean follow-up of 3.0 ± 2 years, 53 patients (35%) in the elderly group died, including 38.2% from non cardiovascular causes of death. Similar proportion of patients received ≥1 appropriate therapy (19.4% vs. 21.6%; P = 0.65) in the elderly group and controls, respectively. There was a trend towards more early perioperative events (P = 0.10) in the elderly, with no significant increase in late complications (P = 0.73). CONCLUSION: Primary prevention ICD recipients ≥80 years in the real world had relatively low associated comorbidity. Rates of appropriate therapies and device-related complications were similar, compared with younger subjects. Nevertheless, the inherent limitations in interpreting observational data on this particular competing risk situation call for randomized controlled trials to provide definitive answers. Meanwhile, a careful multidisciplinary evaluation is needed to guide patient selection for ICD implantation in the elderly population.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Prevenção Primária , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA