1.
Childs Nerv Syst ; 39(8): 1995-1997, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37162522

RESUMO

OBJECTIVE: Due to evidence for proton beam therapy (PBT) in pediatric central nervous system (CNS) tumors, compact proton therapy systems became commercially available to allow better integration in a hospital setting. However, these systems have a non-zero magnetic field at the level of the patient. Often, these patients have a cerebrospinal fluid shunt, and most of them are adjustable through a magnet. Whether the induced magnetic fields could interfere with adjustable shunts is unknown. METHODS: In the first five CNS tumor patients with adjustable shunts who underwent PBT, the shunt setting was controlled before, during, and after treatment with PBT. Additionally, we used an ex vivo adjustable shunt to check if the settings could be altered by the magnetic field. RESULTS: We did not observe unintentional changes in shunt settings in vivo during treatment. In ex vivo testing, the shunt settings were altered directly cranial to the exit window of PBT due to the magnetic field. CONCLUSION: Although we did not observe any shunt setting alteration during PBT in this small cohort, caution is warranted. Given the lack of high-volume data, there should be a low threshold for checking the shunt setting at the end of PBT therapy or in a symptomatic patient.


Assuntos
Neoplasias do Sistema Nervoso Central , Terapia com Prótons , Criança , Humanos , Derivações do Líquido Cefalorraquidiano , Campos Magnéticos , Próteses e Implantes
2.
J Appl Clin Med Phys ; 22(9): 59-72, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34318996

RESUMO

PURPOSE: The integration of auto-segmentation and automated treatment planning methods on a fast-rotating O-ring linac may improve the time efficiency of online adaptive radiotherapy workflows. This study investigates whether automated treatment planning of prostate SBRT with focal boosting on the O-ring linac could generate plans that are of similar quality as those obtained through manual planning on clinical C-arm linacs. METHODS: For 20 men with prostate cancer, reference treatment plans were generated on a TrueBeam STx C-arm linac with HD120 MLC and a TrueBeam C-arm linac with Millennium 120 MLC using 6 MV flattened dual arc VMAT. Manual planning on the Halcyon fast-rotating O-ring linac was performed using 6 MV FFF dual arc VMAT (HA2-DL10) and triple arc VMAT (HA3-DL10) to investigate the performance of the dual-layer MLC system. Automated planning was performed for triple arc VMAT on the Halcyon linac (ET3-DL10) using the automated planning algorithms of Ethos Treatment Planning. The prescribed dose was 35 Gy to the prostate and 30 Gy to the seminal vesicles in five fractions. The iso-toxic focal boost to the intraprostatic tumor nodule(s) was aimed to receive up to 50 Gy. Plan deliverability was verified using portal image dosimetry measurements. RESULTS: Compared to the C-arm linacs, ET3-DL10 shows increased seminal vesicles PTV coverage (D99% ) and reduced high-dose spillage to the bladder (V37Gy ) and urethra (D0.035cc ) but this came at the cost of increased high-dose spillage to the rectum (V38Gy ) and a higher intermediate dose spillage (D2cm). No statistically significant differences were found when benchmarking HA2-DL10 and HA3-DL10 with the C-arm linacs. All plans passed the patient-specific QA tolerance limit. CONCLUSIONS: Automated planning of prostate SBRT with focal boosting on the fast-rotating O-ring linac is feasible and achieves similar plan quality as those obtained on clinical C-arm linacs using manual planning.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Masculino , Próstata , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
3.
BMC Cancer ; 20(1): 457, 2020 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-32448171

RESUMO

BACKGROUND: Patients diagnosed with metastatic castration-refractory prostate cancer (mCRPC) rely on a limited number of therapeutic agents resulting in a median survival of 2-3 years. A subgroup of those patients with mCRPC presents with oligoprogressive disease, with a limited number of progressive lesions while other metastases are still controlled by ongoing systemic treatment. METHODS: In this single arm prospective phase II trial, we aim to include 18 patients with oligoprogressive mCRPC (1-3 metastases and/or local recurrence) who will be treated with metastasis-directed therapy to all visible progressive lesions. Progression is based on conventional imaging, as the use of PSMA PET-CT is considered investigational. However all patients will undergo PSMA PET-CT and the images will be blinded until progression. Primary endpoint is the postponement of the start of next-line systemic treatment (NEST) and the additional clinical value of PSMA PET-CT. Recruitment of patients for this trial started in January 2020 and will be completed approximately by December 2020. DISCUSSION: In this phase 2 trial on oligoprogressive mCRPC, we will investigate the benefit of progression-directed therapy while continuing ongoing systemic treatment. We hypothesize that progression-directed therapy (PDT) with surgery or stereotactic body radiation therapy for these oligoprogressive lesions will postpone the start of next-line systemic treatment and therefore serve as a new or add-on therapy in the spectrum of treatments available for mCRPC. The results of this trial will serve as guidance for a later randomized phase 3 trial. All participants are given an information sheet and are required to give written informed consent. Results will be published in a peer-reviewed journal. TRIAL REGISTRATION: This study is registered at ClinicalTrials.gov: NCT04222634 (December 18th 2019).


Assuntos
Recidiva Local de Neoplasia/terapia , Neoplasias de Próstata Resistentes à Castração/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Seguimentos , Humanos , Masculino , Metastasectomia , Pessoa de Meia-Idade , Metástase Neoplásica , Recidiva Local de Neoplasia/patologia , Ensaios Clínicos Controlados não Aleatórios como Assunto , Prognóstico , Estudos Prospectivos , Neoplasias de Próstata Resistentes à Castração/patologia , Projetos de Pesquisa , Adulto Jovem
4.
J Appl Clin Med Phys ; 15(1): 4437, 2014 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-24423838

RESUMO

The Vero SBRT system was benchmarked in a planning study against the Novalis SRS system for quality of delivered dose distributions to intracranial lesions and assessing the Vero system's capacity for SRS. A total of 27 patients with one brain lesion treated on the Novalis system, with 3 mm leaf width MLC and C-arm gantry, were replanned for Vero, with a 5 mm leaf width MLC mounted on an O-ring gantry allowing rotations around both the horizontal and vertical axis. The Novalis dynamic conformal arc (DCA) planning included vertex arcs, using 90° couch rotation. These vertex arcs cannot be reproduced with Vero due to the mechanical limitations of the O-ring gantry. Alternative class solutions were investigated for the Vero. Additionally, to distinguish between the effect of MLC leaf width and different beam arrangements on dose distributions, the Vero class solutions were also applied for Novalis. In addition, the added value of noncoplanar IMRT was investigated in this study. Quality of the achieved dose distributions was expressed in the conformity index (CI) and gradient index (GI), and compared using a paired Student's t-test with statistical significance for p-values ≤ 0.05. For lesions larger than 5 cm3, no statistical significant difference in conformity was observed between Vero and Novalis, but for smaller lesions, the dose distributions showed a significantly better conformity for the Novalis (ΔCI = 13.74%, p = 0.0002) mainly due to the smaller MLC leaf width. Using IMRT on Vero reduces this conformity difference to nonsignificant levels. The cutoff for achieving a GI around 3, characterizing a sharp dose falloff outside the target volume was 4 cm3 for Novalis and 7 cm3 for Vero using DCA technique. Using noncoplanar IMRT, this threshold was reduced to 3 cm3 for the Vero system. The smaller MLC and the presence of the vertex fields allow the Novalis system to better conform the dose around the lesion and to obtain steeper dose falloff outside the lesion. Comparable dosimetric characteristics can be achieved with Vero for lesions larger than 3 cm3 and using IMRT.


Assuntos
Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional/métodos , Algoritmos , Simulação por Computador , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética , Prognóstico , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
5.
Adv Radiat Oncol ; 8(6): 101258, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37305069

RESUMO

Purpose: To report on the accuracy of automated delineation, treatment plan quality, and duration of an in-silico "scan-(pre)plan-treat" (SPT) workflow for vertebral bone metastases using a 1 × 8 Gy regimen. Method and Materials: The cloud-based emulator system of the Ethos therapy system was used to adapt an organ-at-risk-sparing preplan created on the diagnostic CT to the anatomy-of-the-day using the cone beam CT made before treatment. Results: SPT using the Ethos emulator system resulted in relatively good coverage of the PTV and acceptable dose to the OAR. Delivery time and plan homogeneity was the best for 7-field IMRT plan template. Conclusions: A SPT workflow formula results in a highly conformal treatment delivery while maintaining an acceptable timeframe for the patient on the treatment couch.

6.
Phys Med Biol ; 68(21)2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37844576

RESUMO

Objective:This study evaluates a compact Monte Carlo (MC) model of a pencil beam scanning clinical proton beam using TOPAS to estimate the dose out-of-field (OOF). Compact modelling means that the model starts from a pristine proton beam at the nozzle exit, customised based on acceptance and commissioning data, instead of modelling the full treatment head and room.Approach: First, in-field validation tests were performed. Then, the OOF dose was validated in an RW3 phantom with bubble detectors for personal neutron dosimetry (measuring the neutron dose equivalent) and thermoluminiescent detectors (measuring the absorbed dose by protons and gammas). Measurements were performed at 15 and 35 cm from the distal edge of the field for five different irradiation plans, covering different beam orientations, proton energies and a 40 mm range shifter. TOPAS simulations were performed with QGSP Binary Cascade HP (BIC) and QGSP Bertini HP (Bertini) hadron physics lists.Main results: In-field validation shows that MC simulations agree with point dose measurements within -2.5 % and +1.5 % at locations on- and off-axis and before, in and after the Bragg peak or plateau. The gamma passing rate 2%/3mm of four simulated treatment plans compared to the dose distribution calculated by the TPS exceeds 97 % agreement score. OOF dose simulations showed an average overestimation of 27 % of the neutron dose equivalent for the BIC hadron physics list and an average underestimation of 20 % for the Bertini hadron physics list. The simulated absorbed dose of protons and gammas showed a systematic underestimation which was on average 21 % and 51 % for BIC and Bertini respectively.Significance: Our study demonstrates that a compact MC model can reliably produce in-field data, while out-of-field dose data are within the uncertainties of the detector systems and MC simulations nuclear models, and do so with shorter modelling and faster calculation time.


Assuntos
Terapia com Prótons , Prótons , Dosagem Radioterapêutica , Radiometria , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador , Imagens de Fantasmas
7.
Phys Med Biol ; 67(19)2022 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-36041437

RESUMO

Objective.Protons offer a more conformal dose delivery compared to photons, yet they are sensitive to anatomical changes over the course of treatment. To minimize range uncertainties due to anatomical variations, a new CT acquisition at every treatment session would be paramount to enable daily dose calculation and subsequent plan adaptation. However, the series of CT scans results in an additional accumulated patient dose. Reducing CT radiation dose and thereby decreasing the potential risk of radiation exposure to patients is desirable, however, lowering the CT dose results in a lower signal-to-noise ratio and therefore in a reduced quality image. We hypothesized that the signal-to-noise ratio provided by conventional CT protocols is higher than needed for proton dose distribution estimation. In this study, we aim to investigate the effect of CT imaging dose reduction on proton therapy dose calculations and plan optimization.Approach.To verify our hypothesis, a CT dose reduction simulation tool has been developed and validated to simulate lower-dose CT scans from an existing standard-dose scan. The simulated lower-dose CTs were then used for proton dose calculation and plan optimization and the results were compared with those of the standard-dose scan. The same strategy was adopted to investigate the effect of CT dose reduction on water equivalent thickness (WET) calculation to quantify CT noise accumulation during integration along the beam.Main results.The similarity between the dose distributions acquired from the low-dose and standard-dose CTs was evaluated by the dose-volume histogram and the 3D Gamma analysis. The results on an anthropomorphic head phantom and three patient cases indicate that CT imaging dose reduction up to 90% does not have a significant effect on proton dose calculation and plan optimization. The relative error was employed to evaluate the similarity between WET maps and was found to be less than 1% after reducing the CT imaging dose by 90%.Significance.The results suggest the possibility of using low-dose CT for proton therapy dose estimation, since the dose distributions acquired from the standard-dose and low-dose CTs are clinically equivalent.


Assuntos
Terapia com Prótons , Humanos , Imagens de Fantasmas , Terapia com Prótons/métodos , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Água
8.
Eur Urol Oncol ; 4(2): 305-309, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-31558422

RESUMO

In metastatic castration-refractory prostate cancer (mCRPC), state-of-the-art treatment consists of androgen biosynthesis inhibition (abiraterone), inhibition of the androgen receptor (enzalutamide), chemotherapy, or radium-223 in combination with androgen deprivation therapy (ADT). A subgroup of these patients show oligoprogression, with the progression of only a limited number of metastatic spots, while all other metastases remain controlled by ongoing systemic therapy. In a bi-institutional retrospective study, we tested the hypothesis that progression-directed therapy (PDT) targeting oligoprogressive lesions might defer the initiation of next-line systemic treatment (NEST). A total of 30 patients were diagnosed with mCRPC and experienced oligoprogression, defined as a total of three or fewer progressive lesions either at known metastatic sites and/or the appearance of new metastasis and/or local recurrence. All patients were under active ADT with or without second-line systemic treatment. All patients received PDT targeting the oligoprogressive lesions, while ongoing systemic treatment was maintained. There was median NEST-free survival of 16mo (95% confidence interval [CI] 10-22) and progression-free survival of 10mo (95% CI 6-15) with only minor radiotherapy- or surgery-related toxicity. These findings encourage further prospective trials. PATIENT SUMMARY: In patients with metastatic castration-refractory prostate cancer, surgical treatment or high-dose radiation therapy directed to only the limited number of progressive metastatic spots, while all other metastases remained controlled by ongoing systemic therapy, led to substantial postponement of next-line systemic treatment in our study.


Assuntos
Antagonistas de Androgênios , Neoplasias de Próstata Resistentes à Castração , Antagonistas de Androgênios/uso terapêutico , Humanos , Masculino , Feniltioidantoína/uso terapêutico , Neoplasias de Próstata Resistentes à Castração/terapia , Estudos Retrospectivos
9.
Radiother Oncol ; 156: 10-18, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33264640

RESUMO

BACKGROUND AND PURPOSE: Both gating and tracking can mitigate the deteriorating dosimetric impact of intrafraction translation during prostate stereotactic body radiotherapy (SBRT). However, their ability to manage intrafraction rotation has not yet been thoroughly investigated. The dosimetric accuracy of gating, MLC tracking and couch tracking to manage intrafraction prostate rotation was investigated. MATERIALS AND METHODS: Treatment plans for end-to-end tests of prostate SBRT with focal boosting were generated for a dynamic anthropomorphic pelvis phantom. The phantom applied internal lateral rotation (up to 25°) and coupled vertical and longitudinal translation of a radiochromic film stack that was used for dose measurements. Dose was delivered for each plan while the phantom applied motion according to three typical prostate motion traces without compensation (i), with gating (ii), with MLC tracking (iii) or with couch tracking (iv). Measured doses for the four motion compensation strategies were compared with the planned dose in terms of γ-index analysis, target coverage and organs at risk (OAR) sparing. RESULTS: Intrafraction rotation reduced the 3%(global)/2mm γ-index passing rate (γPR) for the prostate target volume by median (range) -33.2% (-68.6%, -4.1%) when no motion compensation was applied. The use of motion compensation improved the γPR by 13.2% (-0.4%, 32.9%) for gating, by 6.0% (-0.8%, 27.7%) for MLC tracking and by 11.1% (1.2%, 22.9%) for couch tracking. The three compensation techniques improved the target coverage in most cases. Gating showed better OAR sparing than MLC tracking or couch tracking. CONCLUSIONS: Compensation of intrafraction prostate rotation with gating, MLC tracking and couch tracking was investigated experimentally for the first time. All three techniques improved the dosimetric accuracy, but residual motion-related dose errors remained due to the lack of rotation correction.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Movimento , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Rotação
10.
Med Phys ; 46(1): 328-339, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30417523

RESUMO

PURPOSE: A fast-rotating O-ring dedicated intensity modulated radiotherapy (IMRT)/volumetric modulated arc therapy (VMAT) delivery system, the Halcyon, is delivered by default with a fully preconfigured photon beam model in the treatment planning system (TPS). This work reports on the validation and achieved IMRT/VMAT delivery quality on the system. METHODS: Acceptance testing followed the vendor's installation product acceptance and was supplemented with mechanical QA. The dosimetric calibration was performed according to the IAEA TRS-398 code-of-practice, delivering 600 cGy/min at 10 cm depth, a 90 cm source-surface distance, and a 10 × 10 cm² field size. The output factors, multileaf collimator (MLC) transmission and dosimetric leaf gap (DLG) were validated by comparing measurements with the modeled values in the TPS. Validation of IMRT/VMAT was conducted following AAPM reports (MPPG 5.a, TG-119). Next, dose measurements were performed for end-to-end (E2E) checks in heterogeneous anthropomorphic phantoms using radiochromic film in multiple planes and using ionization chambers (IC) point measurements. E2E checks were performed for VMAT (cranial, rectum, spine, and head and neck) and IMRT (lung). Additionally, IROC Houston mailed dosimetry audits were performed for the beam calibration and E2E measurements using a thorax phantom (IMRT) and a head and neck phantom (VMAT). Lastly, extensive patient-specific QA was performed for the first patients of each new indication, 26 in total (nrectum = 2, nspine = 5, nlung = 5, nesophagus = 2, nhead and neck = 7, ncranial = 5), treated on the fast-rotating O-ring linac. The patient-specific QA followed the AAPM TG-218 guidelines and comprised of portal dosimetry, ArcCHECK diode array, radiochromic film dosimetry in a MultiCube phantom, and IC point measurements. RESULTS: The measured output factors showed an agreement <1% for fields ≥3 × 3 cm². Field sizes ≤2 × 2 cm² had a difference of <2%. The measured single-layer MLC transmission was 0.42 ± 0.01% and the measured DLG was 0.27 ± 0.22 mm. The AAPM MPPG 5.a measurements were fully compliant with the guideline criteria. Dose differences larger than 2% were found for the PDD at large depths (>25 cm). TG-119's confidence limits were achieved for the VMAT point dose measurements and for both the IMRT and VMAT radiochromic film measurements. The TG-119 confidence limits were not achieved for IMRT point dose measurements in both the target (5.9%) and the avoidance structure (6.4%). All E2E tests had point differences below 2.3% and gamma agreement scores above 90.6%. The IROC beam calibration audit showed agreement of <1%. The IROC lung IMRT audit and head and neck VMAT audit had results compliant with the IROC Houston's credentialing criteria. All IMRT and VMAT plans selected for patient-specific QA were within the action limits suggested by TG-218. CONCLUSIONS: The fast-rotating O-ring linac and its preconfigured TPS are compliant with the international commissioning criteria of AAPM MPPG 5.a and AAPM TG-119. E2E measurements on heterogeneous anthropomorphic phantoms were within clinically acceptable tolerances. IROC Houston's audits satisfied the credentialing criteria. This work comprises the first extensive dataset reporting on the preconfigured fast-rotating O-ring linac.


Assuntos
Aceleradores de Partículas , Radioterapia de Intensidade Modulada/instrumentação , Rotação , Humanos , Controle de Qualidade , Radiometria , Planejamento da Radioterapia Assistida por Computador
11.
Radiother Oncol ; 128(3): 479-484, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29739713

RESUMO

BACKGROUND AND PURPOSE: Linac improvements in gantry speed, leaf speed and dose rate may increase the time-efficiency of volumetric modulated arc therapy (VMAT) delivery. The plan quality achievable with faster VMAT however remains to be investigated. In this study, a fast-rotating O-ring linac with fast-moving leaves is compared with a C-arm linac in terms of plan quality and delivery time for VMAT of head-and-neck cancer (HNC). MATERIAL AND METHODS: For 30 patients with HNC, treatment planning was performed using dual-arc (HA2) and triple-arc (HA3) VMAT on a Halcyon fast-rotating O-ring linac and using dual-arc VMAT on a TrueBeam C-arm linac (TB2). Target coverage metrics and complication probabilities were compared. Plan delivery was verified using 3%/3 mm gamma-index analysis of helical diode array measurements. Volumetric image acquisition and plan delivery times were compared. RESULTS: All studied VMAT-techniques fulfilled the target coverage objectives. D2% to the boost volume was higher for HA2 (median 103.7%, 1st-3rd quartile [103.5%;104.0%]) and HA3 (103.2% [103.0%;103.7%)] than for TB2 (102.6% [102.3%;103.0%)], resulting in an increased boost target dose heterogeneity for HA2 and HA3. Complication probabilities were comparable between HA2 and TB2, while HA3 showed a xerostomia probability reduction (0.8% [0.2%;1.8%]) and dysphagia probability reduction (1.0% [0.2%;1.8%]) compared with TB2. Gamma-index agreement scores were never below 93.0% for HA2, HA3 and TB2. Volumetric imaging and plan delivery time was shorter for HA2 (1 m 24 s ±â€¯1 s) and HA3 (1 m 54 s ±â€¯1 s) than for TB2 (2 m 47 s ±â€¯1 s). CONCLUSION: For VMAT of HNC, the fast-rotating O-ring linac at least maintains the plan quality of two arcs on a C-arm linac while reducing the image acquisition and plan delivery time.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Dosagem Radioterapêutica
12.
Med Phys ; 45(5): 2205-2217, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29537613

RESUMO

PURPOSE: Liquid fiducial markers have shown to be a promising alternative to solid gold markers in terms of imaging artifact reduction, patient comfort, and compatibility with different imaging modalities. This study aims to investigate the performance of the novel BioXmark® liquid marker for state-of-the-art multimodal imaging used in prostate cancer (PCa) radiotherapy, encompassing kV CT/CBCT, multiparametric MRI, and kV x-ray imaging. In addition, automatic detection of the liquid markers in x-ray imaging for prostate motion monitoring during treatment was investigated. METHODS: A total of eight BioXmark® liquid markers with varying volumes (range 5-300 µL) were casted on a square grid into a gelatin phantom insert. A cylindrical gold marker (QLRAD, length = 7 mm, Ø = 1 mm) was inserted for reference. Liquid marker visibility and streaking artifacts in CT/CBCT imaging were evaluated by placing the gelatin phantom into a CIRS anthropomorphic phantom. Relevant MRI characteristics such as the T2 and T1 relaxation times, the ADC value, and the relative proton density (ρH) were quantified by placing the gelatin phantom insert next to a T1MES mapping phantom and a water-filled syringe for reference. Ex vivo multiparametric MRI images were acquired by placing the gelatin phantom next to a resected prostate specimen. Anterior-posterior x-ray projection images were obtained by placing the gelatin phantom insert on top of an anthropomorphic pelvic phantom with internal pelvic bony structures and were acquired for five positions relative to the bony anatomy and 24 clinically relevant x-ray exposure settings. To quantify individual automatic marker detection, single markers were artificially isolated in the x-ray images using postprocessing. RESULTS: Markers of all sizes were clearly visible on CT and CBCT images with only the largest marker volumes (100-300 µL) displaying artifacts similar in size to the gold fiducial marker. Artifact size increased with increasing liquid marker volume. Liquid markers displayed good contrast in ex vivo T1-weighted and ρH-weighted images. The markers were not visible in the ex vivo T2-weighted image. The liquid markers induced a chemical shift artifact in the obtained ADC-map. Automated detection in x-ray imaging was feasible with high detection success (four of five positions) for marker volumes in the range of 25-200 µL. None of the liquid markers were detected successfully when superimposed on a bony edge, independent of their size. CONCLUSIONS: This study is the first to show the compatibility of BioXmark® liquid markers with multimodal image-guided radiotherapy for PCa. Compared to a solid gold marker, they had favorable results in both visibility and induced imaging artifacts. Liquid marker visibility in MRI imaging of the prostate does not solely depend on the low ρH value (not visible on T2-weighted image) but is also influenced by its relaxation times. Automated marker detection in x-ray images was feasible but better adapted marker detection algorithms are necessary for marker localization in the presence of bony edges. Hence, the liquid marker provides a minimally invasive (fine needles) and highly applicable alternative to current solid gold markers for multimodal image-guided prostate radiotherapy treatments.


Assuntos
Marcadores Fiduciais , Imagem Multimodal/normas , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiocirurgia , Radioterapia Guiada por Imagem , Artefatos , Tomografia Computadorizada de Feixe Cônico , Humanos , Imageamento por Ressonância Magnética , Masculino , Imagens de Fantasmas
13.
Radiother Oncol ; 128(1): 161-166, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-28951008

RESUMO

BACKGROUND & PURPOSE: Intensity-modulated proton therapy (IMPT) of superficial lesions requires pre-absorbing range shifter (RS) to deliver the more shallow spots. RS air gap minimization is important to avoid spot size degradation, but remains challenging in complex geometries such as in head-and-neck cancer (HNC). In this study, clinical endpoints were investigated for patient-specific bolus and for conventional RS solutions, making use of a Monte Carlo (MC) dose engine for IMPT optimization. METHODS AND MATERIALS: For 5 oropharyngeal cancer patients, IMPT spot maps were generated using beamlets calculated with MC. The plans were optimized for three different RS configurations: 3D printed on-skin bolus, snout- and nozzle-mounted RS. Organ-at-risk (OAR) doses and late toxicity probabilities were compared between all configuration-specific optimized plans. RESULTS: The use of bolus reduced the mean dose to all OARs compared to snout and nozzle-mounted RS. The contralateral parotid gland and supraglottic larynx received on average 2.9Gy and 4.2Gy less dose compared to the snout RS. Bolus reduced the average probability for xerostomia by 3.0%. For dysphagia, bolus reduced the probability by 2.7%. CONCLUSIONS: Quantification of the dosimetric advantage of patient-specific bolus shows significant reductions compared to conventional RS solutions for xerostomia and dysphagia probability. These results motivate the development of a patient-specific bolus solution in IMPT for HNC.


Assuntos
Tratamentos com Preservação do Órgão/métodos , Neoplasias Orofaríngeas/radioterapia , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Transtornos de Deglutição/prevenção & controle , Humanos , Doenças da Laringe/prevenção & controle , Método de Monte Carlo , Doenças Parotídeas/prevenção & controle , Probabilidade , Dosagem Radioterapêutica , Xerostomia/prevenção & controle
14.
Radiother Oncol ; 126(2): 339-346, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28992962

RESUMO

PURPOSE: To evaluate the short and long-term variability of breathing induced tumor motion. MATERIALS AND METHODS: 3D tumor motion of 19 lung and 18 liver lesions captured over the course of an SBRT treatment were evaluated and compared to the motion on 4D-CT. An implanted fiducial could be used for unambiguous motion information. Fast orthogonal fluoroscopy (FF) sequences, included in the treatment workflow, were used to evaluate motion during treatment. Several motion parameters were compared between different FF sequences from the same fraction to evaluate the intrafraction variability. To assess interfraction variability, amplitude and hysteresis were compared between fractions and with the 3D tumor motion registered by 4D-CT. Population based margins, necessary on top of the ITV to capture all motion variability, were calculated based on the motion captured during treatment. RESULTS: Baseline drift in the cranio-caudal (CC) or anterior-poster (AP) direction is significant (ie. >5 mm) for a large group of patients, in contrary to intrafraction amplitude and hysteresis variability. However, a correlation between intrafraction amplitude variability and mean motion amplitude was found (Pearson's correlation coefficient, r = 0.72, p < 10-4). Interfraction variability in amplitude is significant for 46% of all lesions. As such, 4D-CT accurately captures the motion during treatment for some fractions but not for all. Accounting for motion variability during treatment increases the PTV margins in all directions, most significantly in CC from 5 mm to 13.7 mm for lung and 8.0 mm for liver. CONCLUSION: Both short-term and day-to-day tumor motion variability can be significant, especially for lesions moving with amplitudes above 7 mm. Abandoning passive motion management strategies in favor of more active ones is advised.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/fisiopatologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/fisiopatologia , Planejamento da Radioterapia Assistida por Computador/métodos , Mecânica Respiratória/fisiologia , Marcadores Fiduciais , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Neoplasias Hepáticas/radioterapia , Neoplasias Pulmonares/radioterapia , Movimento/fisiologia , Radiocirurgia
15.
Phys Med Biol ; 62(13): 5293-5311, 2017 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-28398210

RESUMO

Medulloblastoma treatment involves irradiation of the entire central nervous system, i.e. craniospinal irradiation (CSI). This is associated with the significant exposure of large volumes of healthy tissue and there is growing concern regarding treatment-associated side effects. The current study compares out-of-field organ doses in children receiving CSI through 3D-conformal radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT), helical tomotherapy (HT) and an electron-based technique, and includes radiation doses resulting from imaging performed during treatment. An extensive phantom study is performed, using an anthropomorphic phantom corresponding to a five year old child, in which organ absorbed doses are measured using thermoluminescent detectors. Additionally, the study evaluates and explores tools for calculating out-of-field patient doses using the treatment planning system (TPS) and analytical models. In our study, 3D-CRT resulted in very high doses to a limited number of organs, while it was able to spare organs such as the lungs and breast when compared to IMRT and HT. Both IMRT and HT spread the dose over more organs and were able to spare the heart, thyroid, bladder, uterus and testes when compared to 3D-CRT. The electron-based technique considerably decreased the out-of-field doses in deep-seated organs but could not avoid nearby out-of-field organs such as the lungs, ribs, adrenals, kidneys and uterus. The daily imaging dose is small compared to the treatment dose burden. The TPS error for out-of-field doses was most pronounced for organs further away from the target; nevertheless, no systematic underestimation was observed for any of the studied TPS systems. Finally, analytical modeling was most optimal for 3D-CRT although the number of organs that could be modeled was limited. To conclude, none of the techniques studied was capable of sparing all organs from out-of-field doses. Nevertheless, the electron-based technique showed the most promise for out-of-field organ dose reduction during CSI when compared to photon techniques.


Assuntos
Radiação Cranioespinal/métodos , Elétrons/uso terapêutico , Radioterapia de Intensidade Modulada/métodos , Neoplasias Cerebelares/radioterapia , Criança , Radiação Cranioespinal/efeitos adversos , Feminino , Humanos , Meduloblastoma/radioterapia , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos
16.
Radiother Oncol ; 122(3): 347-351, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28117078

RESUMO

BACKGROUND AND PURPOSE: Dynamic Wave Arc (DWA) is a system-specific noncoplanar arc technique that combines synchronized gantry-ring rotation with D-MLC optimization. This paper presents the clinical workflow, quality assurance program, and reports the geometric and dosimetric results of the first patient cohort treated with DWA. METHODS AND MATERIALS: The RayStation TPS was clinically integrated on the Vero SBRT platform for DWA treatments. The first 15 patients treated with DWA represent a broad range of treatment sites: breast boost, prostate, lung SBRT and bone metastases, which allowed us to explore the potentials and assess the limitations of the current DWA site-specific template solution. For the DWA verification a variety of QA equipment was used, from 3D diode array to an anthropomorphic end-to-end phantom. The geometric accuracy of each arc was verified with an independent orthogonal fluoroscopy method. RESULTS: The average beam-on delivery time was 3min, ranging from 1.22min to 8.82min. All patient QAs passed our institutional clinical criteria of gamma index. For both EBT3 film and Delta4 measurements, DWA planned versus delivered dose distributions presented an average agreement above 97%. An overall mean gantry-ring geometric deviation of -0.03°±0.46° and 0.18°±0.26° was obtained, respectively. CONCLUSION: For the first time, DWA has been translated into the clinic and used to treat various treatment sides. DWA has been successfully added to the noncoplanar rotational IMRT techniques arsenal, allowing additional flexibility in dose shaping while preserving dosimetrically robust delivery.


Assuntos
Neoplasias Ósseas/radioterapia , Neoplasias da Mama/radioterapia , Neoplasias Pulmonares/radioterapia , Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Estudos de Coortes , Feminino , Fluoroscopia , Humanos , Masculino , Posicionamento do Paciente/métodos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
17.
Med Phys ; 43(10): 5392, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27782703

RESUMO

PURPOSE: 3D printing technology is investigated for the purpose of patient immobilization during proton therapy. It potentially enables a merge of patient immobilization, bolus range shifting, and other functions into one single patient-specific structure. In this first step, a set of 3D printed materials is characterized in detail, in terms of structural and radiological properties, elemental composition, directional dependence, and structural changes induced by radiation damage. These data will serve as inputs for the design of 3D printed immobilization structure prototypes. METHODS: Using four different 3D printing techniques, in total eight materials were subjected to testing. Samples with a nominal dimension of 20 × 20 × 80 mm3 were 3D printed. The geometrical printing accuracy of each test sample was measured with a dial gage. To assess the mechanical response of the samples, standardized compression tests were performed to determine the Young's modulus. To investigate the effect of radiation on the mechanical response, the mechanical tests were performed both prior and after the administration of clinically relevant dose levels (70 Gy), multiplied with a safety factor of 1.4. Dual energy computed tomography (DECT) methods were used to calculate the relative electron density to water ρe, the effective atomic number Zeff, and the proton stopping power ratio (SPR) to water SPR. In order to validate the DECT based calculation of radiological properties, beam measurements were performed on the 3D printed samples as well. Photon irradiations were performed to measure the photon linear attenuation coefficients, while proton irradiations were performed to measure the proton range shift of the samples. The directional dependence of these properties was investigated by performing the irradiations for different orientations of the samples. RESULTS: The printed test objects showed reduced geometric printing accuracy for 2 materials (deviation > 0.25 mm). Compression tests yielded Young's moduli ranging from 0.6 to 2940 MPa. No deterioration in the mechanical response was observed after exposure of the samples to 100 Gy in a therapeutic MV photon beam. The DECT-based characterization yielded Zeff ranging from 5.91 to 10.43. The SPR and ρe both ranged from 0.6 to 1.22. The measured photon attenuation coefficients at clinical energies scaled linearly with ρe. Good agreement was seen between the DECT estimated SPR and the measured range shift, except for the higher Zeff. As opposed to the photon attenuation, the proton range shifting appeared to be printing orientation dependent for certain materials. CONCLUSIONS: In this study, the first step toward 3D printed, multifunctional immobilization was performed, by going through a candidate clinical workflow for the first time: from the material printing to DECT characterization with a verification through beam measurements. Besides a proof of concept for beam modification, the mechanical response of printed materials was also investigated to assess their capabilities for positioning functionality. For the studied set of printing techniques and materials, a wide variety of mechanical and radiological properties can be selected from for the intended purpose. Moreover the elaborated hybrid DECT methods aid in performing in-house quality assurance of 3D printed components, as these methods enable the estimation of the radiological properties relevant for use in radiation therapy.


Assuntos
Imobilização , Impressão Tridimensional , Terapia com Prótons/métodos , Humanos , Fenômenos Mecânicos , Posicionamento do Paciente , Fótons , Tomografia Computadorizada por Raios X
18.
Radiat Oncol ; 11: 63, 2016 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-27130434

RESUMO

BACKGROUND: Dynamic Wave Arc (DWA) is a clinical approach designed to maximize the versatility of Vero SBRT system by synchronizing the gantry-ring noncoplanar movement with D-MLC optimization. The purpose of this study was to verify the delivery accuracy of DWA approach and to evaluate the potential dosimetric benefits. METHODS: DWA is an extended form of VMAT with a continuous varying ring position. The main difference in the optimization modules of VMAT and DWA is during the angular spacing, where the DWA algorithm does not consider the gantry spacing, but only the Euclidian norm of the ring and gantry angle. A preclinical version of RayStation v4.6 (RaySearch Laboratories, Sweden) was used to create patient specific wave arc trajectories for 31 patients with various anatomical tumor regions (prostate, oligometatstatic cases, centrally-located non-small cell lung cancer (NSCLC) and locally advanced pancreatic cancer-LAPC). DWA was benchmarked against the current clinical approaches and coplanar VMAT. Each plan was evaluated with regards to dose distribution, modulation complexity (MCS), monitor units and treatment time efficiency. The delivery accuracy was evaluated using a 2D diode array that takes in consideration the multi-dimensionality of DWA during dose reconstruction. RESULTS: In centrally-located NSCLC cases, DWA improved the low dose spillage with 20 %, while the target coverage was increased with 17 % compared to 3D CRT. The structures that significantly benefited from using DWA were proximal bronchus and esophagus, with the maximal dose being reduced by 17 % and 24 %, respectively. For prostate and LAPC, neither technique seemed clearly superior to the other; however, DWA reduced with more than 65 % of the delivery time over IMRT. A steeper dose gradient outside the target was observed for all treatment sites (p < 0.01) with DWA. Except the oligometastatic cases, where the DWA-MCSs indicate a higher modulation, both DWA and VMAT modalities provide plans of similar complexity. The average É£ (3 % /3 mm) passing rate for DWA plans was 99.2 ± 1 % (range from 96.8 to 100 %). CONCLUSIONS: DWA proven to be a fully functional treatment technique, allowing additional flexibility in dose shaping, while preserving dosimetrically robust delivery and treatment times comparable with coplanar VMAT.


Assuntos
Neoplasias/radioterapia , Neoplasias da Próstata/radioterapia , Radiometria/métodos , Radiocirurgia/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Benchmarking/métodos , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Bases de Dados Factuais , Humanos , Neoplasias Pulmonares/radioterapia , Masculino , Metástase Neoplásica , Órgãos em Risco , Neoplasias Pancreáticas/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Fatores de Tempo
19.
Radiother Oncol ; 119(3): 519-24, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27179921

RESUMO

PURPOSE: To optimize the local control of stereotactic body radiotherapy (SBRT) using the Vero-SBRT system and respiratory motion management in patients with oligometastatic cancer. MATERIALS AND METHODS: Patients with five or less metastases were eligible. In metastases with significant motion, a fiducial was implanted for Vero dynamic tracking. For other metastases an internal target volume (ITV) was defined to encompass the respiratory tumor trajectory. A dose of 50Gy in 10 fractions was prescribed on the 80% isodose line. RESULTS: We treated 87 metastases in 44 patients, with colorectal cancer as the most common primary origin (65.9%). Metastatic sites were mainly lung (n=62) and liver (n=17). Twenty-seven metastases were treated with dynamic tracking, the remaining 60 using the ITV-concept. Three patients (7%) experienced grade ⩾3 toxicity. After a median follow-up of 12months, the overall one-year local control (LC) amounted to 89% (95% CI 77-95%), with corresponding values of 90% and 88% for the metastases irradiated with the ITV-approach and dynamic tracking, respectively. Median progression-free survival reached 6.5months, one-year overall survival 95%. CONCLUSIONS: SBRT with proper respiratory motion management resulted in a high LC and an acceptable toxicity profile in oligometastatic cancer patients.


Assuntos
Neoplasias Colorretais/radioterapia , Radiocirurgia/métodos , Adulto , Idoso , Neoplasias Colorretais/mortalidade , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Metástase Neoplásica , Órgãos em Risco , Estudos Prospectivos , Radiocirurgia/efeitos adversos
20.
Radiother Oncol ; 119(1): 159-65, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27016171

RESUMO

PURPOSE: A study of real-time adaptive radiotherapy systems was performed to test the hypothesis that, across delivery systems and institutions, the dosimetric accuracy is improved with adaptive treatments over non-adaptive radiotherapy in the presence of patient-measured tumor motion. METHODS AND MATERIALS: Ten institutions with robotic(2), gimbaled(2), MLC(4) or couch tracking(2) used common materials including CT and structure sets, motion traces and planning protocols to create a lung and a prostate plan. For each motion trace, the plan was delivered twice to a moving dosimeter; with and without real-time adaptation. Each measurement was compared to a static measurement and the percentage of failed points for γ-tests recorded. RESULTS: For all lung traces all measurement sets show improved dose accuracy with a mean 2%/2mm γ-fail rate of 1.6% with adaptation and 15.2% without adaptation (p<0.001). For all prostate the mean 2%/2mm γ-fail rate was 1.4% with adaptation and 17.3% without adaptation (p<0.001). The difference between the four systems was small with an average 2%/2mm γ-fail rate of <3% for all systems with adaptation for lung and prostate. CONCLUSIONS: The investigated systems all accounted for realistic tumor motion accurately and performed to a similar high standard, with real-time adaptation significantly outperforming non-adaptive delivery methods.


Assuntos
Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador , Robótica/instrumentação , Sistemas Computacionais , Humanos , Masculino , Movimento , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos