Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38485518

RESUMO

BACKGROUND: Although right atrial (RA) myocardial deformation has important implications for patient diagnosis, prognosis, and risk stratification, its implementation in clinical practice has been hampered by limited normal reference values, especially in Asian populations. PURPOSE: To establish age- and sex-specific reference values for RA strain, strain rate (SR), and displacement based on a large sample of healthy Chinese adults using MR-feature tracking (MR-FT). STUDY TYPE: Retrospective. POPULATION: 524 healthy Chinese adults (287 male; mean age 43.7 ± 11.9 years). FIELD STRENGTH/SEQUENCE: 1.5T/balanced steady-state free precession. ASSESSMENT: RA deformation parameters, including reservoir, conduit, and booster strain (εs, εe, and εa), peak positive, early negative, and late negative SR (SRs, SRe, and SRa), and total, passive, and active displacement (Ds, De, and Da), were assessed using MR-FT. STATISTICAL TESTS: Student's t-test, one-way ANOVA, coefficients of determination (r2 ), intraclass correlation coefficients (ICC), and Bland-Altman plots. A P value <0.05 was considered significant. RESULTS: Women demonstrated significantly greater magnitudes of RA deformation parameters than men: εs (57.4% ± 15.1% vs. 44.3% ± 12.6%), εe (37.5% ± 13.4% vs. 27.4% ± 10.9%), εa (19.9% ± 5.7% vs. 16.9% ± 5.0%), SRs (2.62 ± 0.88 sec-1 vs. 2.00 ± 0.63 sec-1 ), SRe (-2.98 ± 1.26 sec-1 vs. -2.16 ± 0.92 sec-1 ), SRa (-2.28 ± 0.75 sec-1 vs. -1.84 ± 0.62 sec-1 ), Ds (-7.80 ± 1.90 mm vs. -7.46 ± 1.70 mm), and De (-4.84 ± 1.31 mm vs. -4.49 ± 1.21 mm). For both sexes, aging was significantly associated with decreased RA reservoir and conduit function (εs, SRs, Ds, εe, SRe, and De), and with increased εa and Da. RA deformation measurements had good to excellent intraobserver and interobserver reproducibility, with ICCs ranging from to 0.790 to 0.972. DATA CONCLUSION: This study provides age- and sex-specific reference values of RA strain, SR, and displacement based on a large cohort of healthy Chinese adults using MR-FT. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.

2.
J Magn Reson Imaging ; 2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-38156373

RESUMO

BACKGROUND: The clinical value of myocardial torsion quantification in prognostic assessment and risk stratification of various cardiovascular diseases is gradually being recognized. However, normal values of left and right ventricular (LV and RV) torsion and torsion rates (TRs) have not been fully determined, and their correlation with age and gender has not been well studied. PURPOSE: To establish normal ranges of biventricular torsion, peak systolic and diastolic TRs using magnetic resonance feature tracking (MR-FT) technique based on a large sample of healthy adults, and further investigate their relationship with age and gender. STUDY TYPE: Retrospective. POPULATION: 566 Healthy adults (312 males, aged 43 ± 10 years; 254 females, aged 43 ± 11 years). FIELD STRENGTH/SEQUENCE: 1.5T/gradient echo. ASSESSMENT: Biventricular torsion, peak systolic, and diastolic TRs. STATISTICAL TESTS: Shapiro-Wilk test, Student's t-test, Mann-Whitney-U test, linear regression, intraclass correlation coefficient, Bland-Altman analysis. Differences were regarded as statistically significant at P < 0.05. RESULTS: Women demonstrated greater magnitudes of left ventricle (LV) torsion (1.23 ± 0.44 vs. 1.00 ± 0.42°/cm), peak systolic TR (9.69 ± 3.70 vs. 8.27 ± 3.73°/cm*sec), peak diastolic TR (-7.78 ± 2.82 vs. -6.06 ± 2.44°/cm*sec), and RV torsion (2.20 ± 1.23 vs. 1.65 ± 1.11°/cm*sec), peak systolic TR (16.07 ± 8.18 vs. 12.62 ± 7.08°/cm*sec), peak diastolic TR (-15.39 ± 6.53 vs. -11.70 ± 6.03°/cm*sec). For both genders, the magnitudes of LV and RV torsion, peak systolic, and diastolic TRs increased linearly with age. All the measurements of biventricular torsion, peak systolic and diastolic TRs achieved good to excellent intraobserver and interobserver reproducibility, with all intraclass correlation coefficients >0.70. DATA CONCLUSION: The present study systematically provided age- and sex-stratified reference values for LV and RV torsion and TRs using MR-FT technique. Women and aging are associated with greater magnitudes of biventricular torsion, peak systolic, and diastolic TRs. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.

3.
N Engl J Med ; 381(8): 739-748, 2019 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-31433921

RESUMO

BACKGROUND: The role of assessment of myocardial viability in identifying patients with ischemic cardiomyopathy who might benefit from surgical revascularization remains controversial. Furthermore, although improvement in left ventricular function is one of the goals of revascularization, its relationship to subsequent outcomes is unclear. METHODS: Among 601 patients who had coronary artery disease that was amenable to coronary-artery bypass grafting (CABG) and who had a left ventricular ejection fraction of 35% or lower, we prospectively assessed myocardial viability using single-photon-emission computed tomography, dobutamine echocardiography, or both. Patients were randomly assigned to undergo CABG and receive medical therapy or to receive medical therapy alone. Left ventricular ejection fraction was measured at baseline and after 4 months of follow-up in 318 patients. The primary end point was death from any cause. The median duration of follow-up was 10.4 years. RESULTS: CABG plus medical therapy was associated with a lower incidence of death from any cause than medical therapy alone (182 deaths among 298 patients in the CABG group vs. 209 deaths among 303 patients in the medical-therapy group; adjusted hazard ratio, 0.73; 95% confidence interval, 0.60 to 0.90). However, no significant interaction was observed between the presence or absence of myocardial viability and the beneficial effect of CABG plus medical therapy over medical therapy alone (P = 0.34 for interaction). An increase in left ventricular ejection fraction was observed only among patients with myocardial viability, irrespective of treatment assignment. There was no association between changes in left ventricular ejection fraction and subsequent death. CONCLUSIONS: The findings of this study do not support the concept that myocardial viability is associated with a long-term benefit of CABG in patients with ischemic cardiomyopathy. The presence of viable myocardium was associated with improvement in left ventricular systolic function, irrespective of treatment, but such improvement was not related to long-term survival. (Funded by the National Institutes of Health; STICH ClinicalTrials.gov number, NCT00023595.).


Assuntos
Ponte de Artéria Coronária , Coração/fisiologia , Isquemia Miocárdica/cirurgia , Volume Sistólico , Idoso , Ecocardiografia sob Estresse , Feminino , Seguimentos , Coração/diagnóstico por imagem , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica/fisiopatologia , Modelos de Riscos Proporcionais , Estudos Prospectivos , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento , Função Ventricular Esquerda
4.
J Cardiovasc Magn Reson ; 24(1): 63, 2022 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-36404299

RESUMO

BACKGROUND: As a noninvasive tool, myocardial deformation imaging may facilitate the early detection of cardiac dysfunction. However, normal reference ranges of myocardial strain and strain rate (SR) based on large-scale East Asian populations are still lacking. This study aimed to provide reference values of left ventricular (LV) and right ventricular (RV) strain and SR based on a large cohort of healthy Chinese adults using cardiovascular magnetic resonance (CMR) feature tracking (FT). METHODS: Five hundred and sixty-six healthy Chinese adults (55.1% men) free of hypertension, diabetes, and obesity were included. On cine CMR, biventricular global radial, circumferential, and longitudinal strain (GRS, GCS, and GLS), and the peak radial, circumferential, and longitudinal systolic, and diastolic SRs (PSSRR, PSSRC, PSSRL, PDSRR, PDSRC, and PDSRL), and regional radial and circumferential strain at the basal, mid-cavity, and apical levels were measured. Associations of global and regional biventricular deformation indices with age and sex were investigated. RESULTS: Women demonstrated greater magnitudes of LV GRS (37.6 ± 6.1% vs. 32.1 ± 5.3%), GCS (- 20.7 ± 1.9% vs. - 18.8 ± 1.9%), GLS (- 17.8 ± 1.8% vs. - 15.6 ± 1.8%), RV GRS (25.1 ± 7.8% vs. 22.1 ± 6.7%), GCS (- 14.4 ± 3.6% vs. - 13.2 ± 3.2%), GLS (- 22.4 ± 5.2% vs. - 20.2 ± 4.6%), and biventricular peak systolic and diastolic SR in all three coordinate directions (all P < 0.05). For the LV, aging was associated with increasing amplitudes of GRS, GCS, and decreasing amplitudes of PDSRR, PDSRC, PDSRL (all P < 0.05). For the RV, aging was associated with an increase in the magnitudes of GRS, GCS, GLS, PSSRR, PSSRC, PSSRL, and a decrease in the magnitude of PDSRR, PDSRC (all P < 0.05). Biventricular radial and circumferential strain measurements at the basal, mid-cavity, and apical levels were all significantly related to age and sex in both sexes (all P < 0.05). CONCLUSIONS: We provide age- and sex-specific normal values of biventricular strain and SR based on a large sample of healthy Chinese adults with a broad age range. These results may be served as a reference standard for cardiac function assessment, especially for the Chinese population.


Assuntos
Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda , Humanos , Adulto , Masculino , Feminino , Valores de Referência , Imagem Cinética por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Espectroscopia de Ressonância Magnética , China
5.
J Magn Reson Imaging ; 54(6): 1784-1793, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34131972

RESUMO

BACKGROUND: While reference values of left atrial (LA) deformation parameters in Western populations have been established, reference data in healthy Asian populations are limited. PURPOSE: To establish age- and sex-specific reference values for LA strain and strain rate (SR) based on a large sample of healthy Chinese adults using magnetic resonance-feature tracking (MR-FT). STUDY TYPE: Retrospective. POPULATION: Four hundred and eight healthy Chinese adults (220 males, aged 43.5 ± 11.5 years; 188 females, aged 45.3 ± 12.8 years). FIELD STRENGTH/SEQUENCE: 1.5 T/balanced steady-state free precession. ASSESSMENT: Reservoir strain (εs ), conduit strain (εe ), booster strain (εa ), peak positive SR (SRs), peak early negative SR (SRe), and peak late negative SR (SRa) were obtained by MR-FT. STATISTICAL TESTS: We used Shapiro-Wilk test, Student's t-test, Mann-Whitney U-test, linear regression, and coefficient of determination (r2 ). RESULTS: Women demonstrated significantly greater LA strain (εs [%]: 44.0 ± 9.9 vs. 38.3 ± 8.7; εe [%]: 26.7 ± 8.0 vs. 22.3 ± 6.8; εa [%]: 17.3 ± 4.4 vs. 16.0 ± 3.8) and SR (SRs [/second]: 1.8 ± 0.5 vs. 1.6 ± 0.4; SRe [/second]: -2.5 ± 0.9 vs. -2.1 ± 0.7; SRa [/second]: -1.9 ± 0.6 vs. -1.8 ± 0.5) than men. For both sexes, aging was significantly associated with decreased εs , SRs, εe , and SRe (r2  = 0.07, r2  = 0.05, r2  = 0.19, and r2  = 0.24 for men; r2  = 0.13, r2  = 0.11, r2  = 0.31, and r2  = 0.46 for women), and significantly increased εa (r2  = 0.03 and r2  = 0.05 for men and women). There was no significant correlation between age and SRa in both sexes (P = 0.057 and P = 0.377 for men and women, respectively). DATA CONCLUSION: We provide age- and sex-specific reference values for LA strain and SR based on a large sample of healthy Chinese adults using MR-FT. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 5.


Assuntos
Função do Átrio Esquerdo , Átrios do Coração , China , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Valores de Referência , Estudos Retrospectivos
6.
Rev Cardiovasc Med ; 15(4): 320-31, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25662926

RESUMO

Rheumatoid arthritis (RA) is a multiorgan inflammatory disorder affecting approximately 1% of the population that leads to progressive joint destruction and disability. Patients with RA exhibit a high risk of cardiovascular disease, which results in premature morbidity and mortality and reduced life expectancy, when compared with the general population. Among various guises of myocardial involvement, heart failure (HF) has been recently recognized as an important contributory factor to the excess cardiovascular mortality associated with RA. HF in RA typically presents with occult clinical symptomatology and is mainly associated with structural and functional left ventricular abnormalities leading to diastolic dysfunction, while systolic myocardial performance remains well preserved. As isolated diastolic dysfunction is a predictor of high mortality, the evaluation of patients in early asymptomatic stages, when treatment targeting the heart is more likely to be effective, is of great importance. Although patient history and physical examination remain the cornerstones of HF evaluation, noninvasive imaging of cardiac chambers, coronary arteries, and great vessels may be necessary. Echocardiography, nuclear techniques, and invasive coronary angiography are already established in the routine assessment of HF; however, many aspects of HF pathophysiology in RA remain obscure, due to the limitations of currently used techniques. The capability of cardiovascular magnetic resonance (CMR) to capture early tissue changes allows timely detection of pathophysiologic phenomena of HF in RA, such as myocardial inflammation and myocardial perfusion defects, due to either macrovascular (coronary artery disease) or microvascular (vasculitis) disease. Therefore, CMR may be a useful tool for early, accurate diagnosis and research in patients with RA.


Assuntos
Artrite Reumatoide/complicações , Insuficiência Cardíaca/diagnóstico , Imageamento por Ressonância Magnética , Artrite Reumatoide/diagnóstico , Artrite Reumatoide/mortalidade , Diagnóstico Precoce , Fibrose , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Miocárdio/patologia , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco , Fatores de Tempo , Função Ventricular
7.
Eur Heart J ; 34(1): 39-47, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22584648

RESUMO

AIMS: The Surgical Treatment for Ischemic Heart Failure (STICH) trial demonstrated no overall benefit when surgical ventricular reconstruction (SVR) was added to coronary artery bypass grafting (CABG) in patients with ischaemic cardiomyopathy. The present analysis was to determine whether, based on baseline left ventricular (LV) function parameters, any subgroups could be identified that benefited from SVR. METHODS AND RESULTS: Among the 1000 patients enrolled, Core Lab measures of baseline LV function with adequate quality were obtained in 710 patients using echocardiography, in 352 using cardiovascular magnetic resonance, and in 344 using radionuclide imaging. The relationship between LV end-systolic volume index (ESVI), end-diastolic volume index, ejection fraction (EF), regional wall motion abnormalities, and outcome were first assessed only by echocardiographic measures, and then by 13 algorithms using a different hierarchy of imaging modalities and their quality. The median ESVI and EF were 78.0 (range: 22.8-283.8) mL/m2 and 28.0%, respectively. Hazard ratios comparing the randomized arms by subgroups of LVESVI and LVEF measured by echocardiography found that patients with smaller ventricles (LVESVI <60 mL/m2) and better LVEF (≥33%) may have benefitted by SVR, while those with larger ventricles (LVESVI >90 mL/m(2)) and lower LVEF (≤25%) did worse with SVR. Algorithms using all three imaging modalities found a weaker relationship between LV global function and the effects of SVR. The extent of regional wall motion abnormality did not influence the effects of SVR. CONCLUSIONS: Subgroup analyses of the STICH trial suggest that patients with less dilated LV and better LVEF may benefit from SVR, while those with larger LV and poorer LVEF may do worse. Clinical Trial Registration #: NCT00023595.


Assuntos
Cardiomiopatias/cirurgia , Doença da Artéria Coronariana/cirurgia , Ventrículos do Coração/cirurgia , Idoso , Algoritmos , Cardiomiopatias/fisiopatologia , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Volume Sistólico/fisiologia , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação Ventricular/fisiologia
8.
Rev Cardiovasc Med ; 14(1): 49-55, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23651986

RESUMO

Cardiovascular manifestations in systemic vasculitis include initially silent cardiomyopathy due to either ischemic or inflammatory causes. The combination of vasculitis and cardiomyopathy is associated with a poor prognosis. Early treatment with immunosuppressants in conjunction with appropriate cardiac pharmacotherapy is considered important and has dramatically improved prognosis. Cardiovascular magnetic resonance, due to its nonionizing, noninvasive evaluation of the cardiovascular system, can be of great value in the diagnosis, follow-up, and treatment of patients with systemic vasculitis.


Assuntos
Insuficiência Cardíaca/diagnóstico , Imageamento por Ressonância Magnética , Vasculite Sistêmica/diagnóstico , Fármacos Cardiovasculares/uso terapêutico , Diagnóstico Precoce , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Imunossupressores/uso terapêutico , Valor Preditivo dos Testes , Prognóstico , Fatores de Risco , Vasculite Sistêmica/complicações , Vasculite Sistêmica/tratamento farmacológico , Vasculite Sistêmica/fisiopatologia
9.
Int J Cardiol ; 352: 180-187, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35124105

RESUMO

BACKGROUND: The left and right atrial (LA and RA) size and function are tightly linked to the morbidity and mortality of multiple cardiovascular diseases. We aimed to establish cardiovascular magnetic resonance (CMR) reference values for LA and RA volumes and phasic function based on a large sample of healthy Chinese adults. METHODS: 408 validated healthy Chinese adults (54% men; aged 21-70 years) were included. LA and RA maximum, minimum, and pre-atrial contraction volumes (Vmax, Vmin, and Vpac); total, passive, and booster emptying fractions (EF total, EF passive, and EF booster); and total, passive, and active emptying volumes (TEV, PEV, and AEV) were measured on cine CMR. Normal reference values were calculated and were stratified by sex and age decades. RESULTS: Men demonstrated greater LAVmax, LAVmin, LAVpac, LAPEV, RAVmax, RAVmin, RAVpac, RATEV, and RAAEV, while women had higher LAEF total, LAEF booster, RAEF total, RAEF passive, and RAEF booster (all p < 0.05). Age was positively correlated with LAVpac and RAVpac in both sexes but was positively correlated with LAVmax, LAVmin, RAVmax, and RAVmin only in women (all p < 0.05). For both sexes, aging was associated with decreased LAEF total, LAEF passive, RAEF total, and RAEF passive, but increased LAEF booster (all p < 0.05). CONCLUSION: We systematically provide age- and sex-specific CMR reference values for LA and RA volumes and phasic function based on a large sample of healthy Chinese adults with a wide age range. Both age and sex are closely associated with biatrial volumes and function.


Assuntos
Função do Átrio Esquerdo , Átrios do Coração , Adulto , Idoso , China/epidemiologia , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
10.
Acta Diabetol ; 59(4): 491-499, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34779950

RESUMO

AIMS: The aim of this study was to evaluate alterations in left ventricular (LV) systolic and diastolic function in subjects with prediabetes and diabetes using cardiovascular magnetic resonance-feature tracking (CMR- FT). METHODS: We included 35 subjects with prediabetes, 30 subjects with diabetes, and 33 healthy controls of similar age and sex distributions who underwent CMR examination. LV global radial, circumferential, and longitudinal strain (GRS, GCS, and GLS), peak systolic strain rate (PSSR), and peak diastolic strain rate (PDSR) were measured and compared among the three groups. Pearson's correlation and linear regression analyses were applied for statistical analyses. RESULTS: Subjects with prediabetes and diabetes had a significantly lower GLS than healthy controls, but there were no significant differences in ejection fraction (EF), GRS, GCS, or global radial, circumferential and longitudinal PSSR among the three groups. Global radial, circumferential, and longitudinal PDSR in patients with diabetes were all significantly lower than those in the healthy controls. Compared to subjects with prediabetes, patients with diabetes had a significantly lower global circumferential PDSR. Global longitudinal PDSR in subjects with prediabetes was significantly lower than that in healthy controls. Multivariable linear regression analyses demonstrated that elevated HbA1c levels were independently associated with decreased global circumferential and longitudinal PDSR (ß = -0.203, p = 0.023; ß = -0.207, p = 0.040, respectively). CONCLUSIONS: CMR-FT has potential value to evaluate early alterations in LV systolic and diastolic function in subjects with prediabetes and diabetes. Elevated HbA1c levels were independently associated with impaired LV diastolic function in the general population free of overt cardiovascular diseases.


Assuntos
Diabetes Mellitus , Estado Pré-Diabético , Disfunção Ventricular Esquerda , Ventrículos do Coração , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda
11.
Front Cardiovasc Med ; 8: 697481, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34350219

RESUMO

Background: Quantification of cardiac structure and function is essential for diagnostic interpretation and clinical decision making. We sought to establish cardiovascular magnetic resonance (CMR) reference values of left and right ventricular (LV and RV) morphology and function based on a large sample of healthy Chinese adults. Methods: Five hundred fifty validated healthy Chinese adults (aged 21-70 years; 323 men) free of hypertension, diabetes, and obesity were included in this study. All the subjects were stratified by gender (men and women) and age decades. On cine CMR, measurements of biventricular end-diastolic, end-systolic, and stroke volumes (EDV, ESV, and SV), ejection fraction (EF), and end-diastolic LV wall thickness (LVWT) and mass (LVM) were obtained. Results: Men had greater LVEDV (111.6 ± 19.8 vs. 94.6 ± 15.6 ml), LVESV (36.5 ± 9.8 vs. 28.2 ± 7.9 ml), LVM (121.1 ± 19.9 vs. 86.1 ± 14.5 g), global end-diastolic LVWT (8.1 ± 1.1 vs. 6.7 ± 1.0 mm), RVEDV (128.0 ± 23.6 vs. 101.7 ± 17.0 ml), and RVESV (53.5 ± 13.7 vs. 36.8 ± 8.9 ml), while women had greater LVEF (67.5 ± 5.4 vs. 70.4 ± 5.7%) and RVEF (58.5 ± 5.2 vs. 64.0 ± 5.3%) (all p < 0.001). For both men and women, age was negatively correlated with LVEDV (r = -0.31 and r = -0.32), LVESV (r = -0.37 and r = -0.47), RVEDV (r = -0.31 and r = -0.29), and RVESV (r = -0.33 and r = -0.44), while it was positively correlated with LVEF (r = 0.28 and r = 0.43) and RVEF (r = 0.28 and r = 0.41) (all p < 0.001). Aging was associated with increasing global end-diastolic LVWT and LVM/LVEDV in both sexes (all p < 0.001). Older age was associated with increasing LVM only in women (r = 0.36, p < 0.001), not in men (r = 0.05, p = 0.359). Conclusions: We systematically provide age-, sex-, and body size-specific CMR reference values for biventricular morphology and function based on a large sample of healthy Chinese adults. Biventricular structure and function are significantly associated with age and sex.

12.
Circulation ; 119(22): e561-87, 2009 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-19451357

RESUMO

The American College of Cardiology Foundation (ACCF), along with key specialty and subspecialty societies, conducted an appropriate use review of common clinical scenarios where cardiac radionuclide imaging (RNI) is frequently considered. This document is a revision of the original Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging (SPECT MPI) Appropriateness Criteria, published 4 years earlier, written to reflect changes in test utilization and new clinical data, and to clarify RNI use where omissions or lack of clarity existed in the original criteria. This is in keeping with the commitment to revise and refine appropriate use criteria (AUC) on a frequent basis. The indications for this review were drawn from common applications or anticipated uses, as well as from current clinical practice guidelines. Sixty-seven clinical scenarios were developed by a writing group and scored by a separate technical panel on a scale of 1 to 9 to designate appropriate use, inappropriate use, or uncertain use. In general, use of cardiac RNI for diagnosis and risk assessment in intermediate- and high-risk patients with coronary artery disease (CAD) was viewed favorably, while testing in low-risk patients, routine repeat testing, and general screening in certain clinical scenarios were viewed less favorably. Additionally, use for perioperative testing was found to be inappropriate except for high selected groups of patients. It is anticipated that these results will have a significant impact on physician decision making, test performance, and reimbursement policy, and will help guide future research.


Assuntos
Técnicas de Diagnóstico Cardiovascular/normas , Coração/diagnóstico por imagem , Cintilografia/normas , American Heart Association , Cardiologia/normas , Doença das Coronárias/diagnóstico , Humanos , Risco , Sociedades Médicas , Estados Unidos
13.
Magn Reson Med ; 63(4): 858-64, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20373386

RESUMO

Three-dimensional (3D) first-pass myocardial perfusion imaging (MPI) is a promising alternative to conventional two-dimensional multislice MPI due to its contiguous spatial coverage that is beneficial for estimating the size of perfusion defects. Data acquisition at mid-diastole is a typical choice for 3D MPI yet is sensitive to arrhythmia and variations in R-R interval that are common in cardiac patients. End systole is the second longest quiescent cardiac phase and is known to be less sensitive to the R-R variability. Therefore, 3D MPI with systolic acquisition may be advantageous in patients with severe arrhythmia once it is proven to be comparable to diastolic MPI in subjects with negligible R-R variation. In this work, we demonstrate the feasibility of 3D MPI with systolic data acquisition in five healthy subjects. We performed 3D MPI experiments in which 3D perfusion data were acquired at both end-systole and mid-diastole of every R-R interval and analyzed the similarity between resulting time intensity curves (TIC) from the two data sets. The correlation between systolic and diastolic TICs was extremely high (mean = 0.9841; standard deviation = 0.0166), and there was a significant linear correlation between the two time intensity curve upslopes and peak enhancements (P < 0.001).


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Adulto , Meios de Contraste/administração & dosagem , Circulação Coronária , Diástole , Estudos de Viabilidade , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Sístole
14.
Magn Reson Med ; 63(6): 1716-22, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20512877

RESUMO

Cine balanced steady-state free precession (SSFP) is the most widely used sequence for assessing cardiac ventricular function at 1.5 T because it provides high signal-to-noise ratio efficiency and strong contrast between myocardium and blood. At 3 T, the use of SSFP is limited by susceptibility-induced off-resonance, resulting in either banding artifacts or the need to use a short-sequence pulse repetition time that limits the readout duration and hence the achievable spatial resolution. In this work, we apply wideband SSFP, a variant of SSFP that uses two alternating pulse repetition times to establish a steady state with wider band spacing in its frequency response and overcome the key limitations of SSFP. Prospectively gated cine two-dimensional imaging with wideband SSFP is evaluated in healthy volunteers and compared to conventional balanced SSFP, using quantitative metrics and qualitative interpretation by experienced clinicians. We demonstrate that by trading off temporal resolution and signal-to-noise ratio efficiency, wideband SSFP mitigates banding artifacts and enables imaging with approximately 30% higher spatial resolution compared to conventional SSFP with the same effective band spacing.


Assuntos
Coração/fisiologia , Imagem Cinética por Ressonância Magnética/métodos , Artefatos , Padrões de Referência , Função Ventricular
15.
J Magn Reson Imaging ; 31(5): 1224-9, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20432360

RESUMO

PURPOSE: To suppress off-resonance artifacts in coronary artery imaging at 3 Tesla (T), and therefore improve spatial resolution. MATERIALS AND METHODS: Wideband steady state free precession (SSFP) sequences use an oscillating steady state to reduce banding artifacts. Coronary artery images were obtained at 3T using three-dimensional navigated gradient echo, balanced SSFP, and wideband SSFP sequences. RESULTS: The highest in-plane resolution of left coronary artery images was 0.68 mm in the frequency-encoding direction. Wideband SSFP produced an average SNR efficiency of 70% relative to conventional balanced SSFP and suppressed off-resonance artifacts. CONCLUSION: Wideband SSFP was found to be a promising approach for obtaining noncontrast, high-resolution coronary artery images at 3 Tesla with reliable image quality.


Assuntos
Algoritmos , Angiografia Coronária/métodos , Vasos Coronários/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Rev Cardiovasc Med ; 10 Suppl 1: S30-7, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19898286

RESUMO

The location, extent, and severity of obstructive coronary artery disease impact cardiovascular risk and mortality in independent and profound ways. Cardiovascular imaging modalities allow physicians to better define the anatomy and physiology of coronary obstructive disease. Conventional coronary angiography remains the most commonly used modality to define coronary anatomy. Computed tomography coronary angiography represents an important innovation, particularly by allowing coronary anatomy to be assessed in a noninvasive fashion. Stress myocardial perfusion imaging with single-photon emission computed tomography is a valuable prognostic tool. Stress testing, echocardiography, and stress myocardial radionuclide perfusion can all play important roles in risk stratification. Stress echocardiography is particularly useful in the clinic, due to the relatively low cost of equipment acquisition and the ability to image without exposure to radiation. The emerging modality of cardiac positron emission tomography offers the prospect of improved resolution, accurate quantification of blood flow, and shorter examination times.


Assuntos
Angina Pectoris/diagnóstico , Doença da Artéria Coronariana/diagnóstico , Diagnóstico por Imagem , Angina Pectoris/etiologia , Doença Crônica , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Diagnóstico por Imagem/métodos , Ecocardiografia sob Estresse , Humanos , Imageamento por Ressonância Magnética , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo
17.
Int J Cardiovasc Imaging ; 35(11): 2057-2065, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31402413

RESUMO

This study was aimed to investigate the correlation between left ventricular (LV) myocardial strain and LV geometry in healthy adults using cardiovascular magnetic resonance-feature tracking (CMR-FT). 124 gender-matched healthy adults who underwent healthy checkup using CMR cine imaging were retrospectively analyzed. Peak global radial, circumferential, longitudinal strain (GRS, GCS and GLS) for left ventricle were measured. LV geometry was assessed by the ratio of LV mass (LVM) and end-diastolic volume (EDV). GRS, GCS and GLS were 34.18 ± 6.71%, - 22.17 ± 2.28%, - 14.76 ± 2.39% for men, and 33.40 ± 6.95%, - 22.49 ± 2.27%, - 15.72 ± 2.36% for women. Multiple linear regression showed that LVM/EDV was associated with decreased GLS (ß = - 0.297, p = 0.005), but was not significantly associated with GRS and GCS (both p > 0.05). There was an increase in the magnitude of GRS, GCS and GLS with advancing age (ß = 0.254, ß = 0.466 and ß = 0.313, all p < 0.05). Greater BMI was associated with decreased GRS, GCS and GLS (ß = - 0.232, ß = - 0. 249 and ß = - 0.279, all p < 0.05). In conclusion, compared with GRS and GCS, GLS is more sensitive to assess LV concentric remodeling in healthy adults. GRS, GCS and GLS are all independently positively associated with age and negatively associated with BMI. Sex-based LV strain reference values for healthy Chinese adults are established.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Contração Miocárdica , Função Ventricular Esquerda , Remodelação Ventricular , Adulto , Fatores Etários , Índice de Massa Corporal , Estudos Transversais , Feminino , Voluntários Saudáveis , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores Sexuais
18.
J Cardiovasc Magn Reson ; 10: 57, 2008 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-19077220

RESUMO

BACKGROUND: In patients with ischemic heart disease, accurate assessment of the extent of myocardial perfusion deficit may be important in predicting prognosis of clinical cardiac outcomes. The aim of this study was to compare the ability of three dimensional (3D) and of two dimensional (2D) multi-slice myocardial perfusion imaging (MPI) using cardiovascular magnetic resonance (CMR) in determining the size of defects, and to demonstrate the feasibility of 3D MPI in healthy volunteers at 3 Tesla. METHODS: A heart phantom was used to compare the accuracy of 3D and 2D multi-slice MPI in estimating the volume fraction of seven rubber insets which simulated transmural myocardial perfusion defects. Three sets of cross-sectional planes were acquired for 2D multi-slice imaging, where each set was shifted along the partition encoding direction by +/- 10 mm. 3D first-pass contrast-enhanced (0.1 mmol/kg Gd-DTPA) MPI was performed in three volunteers with sensitivity encoding for six-fold acceleration. The upslope of the myocardial time-intensity-curve and peak SNR/CNR values were calculated. RESULTS: Mean/standard deviation of errors in estimating the volume fraction across the seven defects were -0.44/1.49%, 2.23/2.97%, and 2.59/3.18% in 3D, 2D 4-slice, and 2D 3-slice imaging, respectively. 3D MPI performed in healthy volunteers produced excellent quality images with whole left ventricular (LV) coverage. Peak SNR/CNR was 57.6 +/- 22.0/37.5 +/- 19.7 over all segments in the first eight slices. CONCLUSION: 3D performed better than 2D multi-slice MPI in estimating the size of perfusion defects in phantoms. Highly accelerated 3D MPI at 3T was feasible in volunteers, allowing whole LV coverage with excellent image quality and high SNR/CNR.


Assuntos
Circulação Coronária , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Isquemia Miocárdica/patologia , Imagem de Perfusão do Miocárdio , Miocárdio/patologia , Meios de Contraste , Estudos de Viabilidade , Gadolínio DTPA , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/instrumentação , Isquemia Miocárdica/fisiopatologia , Imagem de Perfusão do Miocárdio/instrumentação , Imagens de Fantasmas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
19.
Magn Reson Imaging ; 26(5): 661-6, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18420367

RESUMO

The purpose of this study was to demonstrate and evaluate the performance of real-time color-flow MRI at 3 T using variable-density spiral (VDS) phase contrast. Spiral phase contrast imaging was implemented within a flexible real-time interactive MRI system that provided continuous image reconstruction and an intuitive user interface. The pulse sequence consisted of a spectral-spatial excitation, bipolar gradient, spiral readout and gradient spoiler. VDSs were utilized to increase spatial and/or temporal resolution relative to uniform-density spirals (UDSs). Parameter choices were guided by specific applications. Sliding window reconstruction was used to achieve a maximum display rate of 40 frames/s. No breath-holding or gating was used. Our results demonstrated that real-time color-flow movies using UDS and VDS provided adequate visualization of intracardiac flow, carotid flow and proximal coronary flow in healthy volunteers. Average aortic outflow velocity measured at the aortic valve plane using VDS was 29.4% higher than that using UDS. Peak velocity measured in the common carotid artery using VDS was 9.8% higher than that using UDS.


Assuntos
Circulação Coronária , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Valva Aórtica/anatomia & histologia , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/anatomia & histologia , Vasos Coronários/anatomia & histologia , Humanos , Valva Mitral/anatomia & histologia , Interface Usuário-Computador
20.
JAMA Netw Open ; 1(4): e181456, 2018 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-30646130

RESUMO

Importance: Clinical decisions are frequently based on measurement of left ventricular ejection fraction (LVEF). Limited information exists regarding inconsistencies in LVEF measurements when determined by various imaging modalities and the potential impact of such variability. Objective: To determine the intermodality variability of LVEF measured by echocardiography, gated single-photon emission computed tomography (SPECT), and cardiovascular magnetic resonance (CMR) in patients with left ventricular dysfunction. Design, Setting, and Participants: International multicenter diagnostic study with LVEF imaging performed at 127 clinical sites in 26 countries from July 24, 2002, to May 5, 2007, and measured by core laboratories. Secondary study of clinical diagnostic measurements of LVEF in the Surgical Treatment for Ischemic Heart Failure (STICH), a randomized trial to identify the optimal treatment strategy for patients with LVEF of 35% or less and coronary artery disease. Data analysis was conducted from March 19, 2016, to May 29, 2018. Main Outcomes and Measures: At baseline, most patients had an echocardiogram and subsets of patients underwent SPECT and/or CMR. Left ventricular ejection fraction was measured by a core laboratory for each modality independent of the results of other modalities, and measurements were compared among imaging methods using correlation, Bland-Altman plots, and coverage probability methods. Association of LVEF by each method and death was assessed. Results: A total of 2032 patients (mean [SD] age, 60.9 [9.6] years; 1759 [86.6%] male) with baseline LVEF data were included. Correlation of LVEF between modalities was r = 0.601 (for biplane echocardiography and SPECT [n = 385]), r = 0.493 (for biplane echocardiography and CMR [n = 204]), and r = 0.660 (for CMR and SPECT [n = 134]). Bland-Altman plots showed only moderate agreement in LVEF measurements from all 3 core laboratories with no substantial overestimation or underestimation of LVEF by any modality. The percentage of observations that fell within a range of 5% ranged from 43% to 54% between different imaging modalities. Conclusions and Relevance: In this international multicenter study of patients with coronary artery disease and reduced LVEF, there was substantial variation between modalities in LVEF determination by core laboratories. This variability should be considered in clinical management and trial design. Trial Registration: Clinicaltrials.gov Identifier: NCT00023595.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Ecocardiografia , Imageamento por Ressonância Magnética , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Técnicas de Imagem Cardíaca , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA