Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int J Legal Med ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831139

RESUMO

Novel synthetic opioids (NSOs) represent an emerging group of novel psychoactive substances, acting as agonists at the opioid receptors. NSOs include fentanyl-related compounds, e.g. methoxyacetylfentanyl (MeACF), and non-fentanyl analogs, e.g. "U compounds" including U-47700. Here we present three cases of death involving MeACF and U-47700, with particular reference to preliminary data on pharmacokinetics and tissue distribution.After a complete post-mortem examination, general unknown screenings and analysis of drugs of abuse were performed on postmortem samples by immunoassays, gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry. To quantify the analytes of interest in post-mortem blood and tissues, the standard addition method was used. A toxicological significance score (TSS), weighing the role of the NSO in each death case, was assigned.Case 1 died at the hospital after consumption of U-47700, methadone (serum levels: 2,600 ng/ml and 37 ng/ml), tilidine and benzodiazepines. In case 2, U-47700 (204 ng/ml) together with methadone (290 ng/ml), flubromazepam (480 ng/ml) and diazepam (300 ng/ml) were detected in peripheral blood. In case 3, methoxyacetylfentanyl (266 ng/ml), furanylfentanyl (4.3 ng/ml) 4-ANPP (15 ng/ml) and alprazolam (69 ng/ml) were quantified in femoral blood. In all cases, the NSO likely contributed to the death (TSS = 3).NSOs appear to be often consumed in the setting of polydrug intoxications, especially in combination with other opioids and benzodiazepines, which often exert synergistic effects. The standard addition method remains the most reliable in post-mortem analysis and toxicological results should always be evaluated together with circumstantial and autopsy data.

2.
Nucleic Acids Res ; 49(3): 1517-1531, 2021 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-33450006

RESUMO

The maternal mode of mitochondrial DNA (mtDNA) inheritance is central to human genetics. Recently, evidence for bi-parental inheritance of mtDNA was claimed for individuals of three pedigrees that suffered mitochondrial disorders. We sequenced mtDNA using both direct Sanger and Massively Parallel Sequencing in several tissues of eleven maternally related and other affiliated healthy individuals of a family pedigree and observed mixed mitotypes in eight individuals. Cells without nuclear DNA, i.e. thrombocytes and hair shafts, only showed the mitotype of haplogroup (hg) V. Skin biopsies were prepared to generate ρ° cells void of mtDNA, sequencing of which resulted in a hg U4c1 mitotype. The position of the Mega-NUMT sequence was determined by fluorescence in situ hybridization and two different quantitative PCR assays were used to determine the number of contributing mtDNA copies. Thus, evidence for the presence of repetitive, full mitogenome Mega-NUMTs matching haplogroup U4c1 in various tissues of eight maternally related individuals was provided. Multi-copy Mega-NUMTs mimic mixtures of mtDNA that cannot be experimentally avoided and thus may appear in diverse fields of mtDNA research and diagnostics. We demonstrate that hair shaft mtDNA sequencing provides a simple but reliable approach to exclude NUMTs as source of misleading results.


Assuntos
DNA Mitocondrial , Genoma Humano , Núcleo Celular/genética , Variações do Número de Cópias de DNA , Feminino , Humanos , Masculino , Linhagem , Análise de Sequência de DNA
3.
Int J Legal Med ; 134(3): 1095-1102, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32060624

RESUMO

From the first half of the twentieth century to the present day, injuries and fatalities from captive-bolt livestock stunners are a major topic in forensic medicine. The vast majority of cases account for suicides with the frontal, temporal, parietal, and occipital regions being the most common sites of entrance (in descending order of frequency). Due to the limited length of the bolt, the corresponding wound channel within the braincase is only several centimeters long. It has been a controversial subject for a long time, whether the skin-bone complex punched out by the conically grooved end of the steel rod may act as a "secondary projectile" being propelled beyond the actual path of the bolt. To answer this question, experimental shots from various types of captive bolt-guns were fired to simulants. Video-documentation employing a high-speed motion camera showed that the punched-out pieces of skin and bone did not move further than the bolt. Thus, a secondary extension of the total wound channel could not be observed. However, the suction effect caused by the bolt's rearward movement may induce a slight retrograde displacement of the skin-bone complex.


Assuntos
Balística Forense , Medicina Legal , Traumatismos Cranianos Penetrantes/patologia , Ferimentos por Arma de Fogo/patologia , Animais , Armas de Fogo/classificação , Humanos , Modelos Biológicos
4.
Int J Legal Med ; 134(1): 283-294, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31713063

RESUMO

Crossbows are ancient distance weapons, which in modern times have been largely replaced by guns. Nowadays, they are used for target shooting and in some countries also for hunting. Bolts/arrows fired from a crossbow have a rather low initial velocity but a high penetration capacity comparable to bullets shot from firearms. A considerable number of homicidal, suicidal, and accidental crossbow injuries have been reported up to the present day both under clinical and medicolegal aspects. A recent suicide case gave rise to a systematic study of entrance wounds from field-tipped arrows with shafts made of carbon. Composite models (ballistic gelatin covered with pig skin) served as targets. As found in the suicide case presented, the roundish entrance wounds were characterized by a slit-like severance of the skin surrounded by a pronounced blackish ring resembling the bullet wipe in gunshots. The material deposited circularly on the margins was subjected to the sodium rhodizonate test, SEM/EDX analysis, histological examination, and Raman spectroscopy. As expected, the elements typical of gunshot residues could not be detected. The element pattern of the black deposits was consistent with that of the arrows' tips and carbon shafts. Histological examination revealed that the carbonaceous material was deposited on the abraded wound margins suggesting a mechanism of friction causing the transfer of material. In conclusion, the presence of a black-margined roundish skin wound does not necessarily mean a bullet wipe. The casuistic part of the paper deals with a suicidal shot to the chest in a 48-year-old man, inflicted with a field-tipped carbon arrow which perforated both the heart and the thoracic aorta. In addition, a review of the literature on fatal crossbow injuries is presented.


Assuntos
Aorta Torácica/lesões , Traumatismos Cardíacos/etiologia , Suicídio Consumado , Ferimentos Penetrantes/etiologia , Balística Forense , Patologia Legal , Humanos , Masculino , Pessoa de Meia-Idade , Armas
5.
Int J Legal Med ; 133(2): 547-551, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29876635

RESUMO

In urban traffic accidents, mainly pedestrians and cyclists are at risk of being injured and killed. Lethal injuries are usually caused by the immediate impact of a car or a tram. This paper presents a fatal accident without any direct contact with a motor vehicle. A 63-year-old woman sitting on a chair in a pavement cafe was killed by the impact of a 60-year-old male cyclist, who was flung in her direction after colliding with a car. Autopsy yielded intracutaneous haemorrhages on the impact sites of the female victim (left cheek, left shoulder and left upper arm). The woman sustained a ring fracture of the skull base encircling the foramen magnum with subtotal severance of the brain stem and massive chest trauma. All the injuries were caused by the blunt impact of the moving human body. The head was forcibly bent towards the contralateral shoulder resulting in a depression fracture of the skull. Reconstruction of the accident at the scene was challenging, as the fatally injured victim remained sitting on the chair and did not show any striking external signs of traumatisation. According to the assessment of the technical expert, the collision velocity of the moving body amounted to 6-8 m/s.


Assuntos
Aceleração , Acidentes de Trânsito , Ciclismo/lesões , Ferimentos não Penetrantes/patologia , Autopsia , Feminino , Corpo Humano , Humanos , Pessoa de Meia-Idade
6.
Int J Legal Med ; 133(1): 169-176, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30515588

RESUMO

A muzzle imprint mark is a highly diagnostic finding, which indicates a contact shot. In many cases, it also provides additional information on the type of the weapon used and on the way in which it was held at the time of firing. In semi-automatic pistols, some constructional elements constituting the muzzle plane move to the rear together with the slide, which may prevent them from causing a corresponding imprint close to the bullet entrance hole. The present study comprises 30 consecutive autopsy cases of fatal contact shots to the head inflicted with semi-automatic pistols. The imprint marks accompanying the entrance wounds were compared with the muzzle ends of the respective weapons both before and after retracting the slide. It turned out that in a considerable number of cases (3 out of 30), the retractable parts were not depicted or only to a minor degree as components of the imprint mark. In order to validate the presumed correlation, experimental shots were fired to composite models using pistols in which the movable and the stationary parts forming the muzzle plane were dyed with different paints. Thus, it could be demonstrated that the muzzle imprint preferentially mirrors the front sides of the stationary parts such as the barrel end, the recoil guide, and the gun housing. Immediately after discharge, the slide and the ballooning skin of the bullet entrance site move in the same direction. The stationary parts of the weapon block the expansion of the skin bulging towards the muzzle, so that the skin gets firmly pressed against them. The dynamic interaction between the gun and the entrance region resulting in a characteristic imprint mark could be visualized by the use of a high-speed motion camera recording test shots to different composite models.


Assuntos
Armas de Fogo , Balística Forense , Traumatismos Cranianos Penetrantes/patologia , Pele/lesões , Pele/patologia , Ferimentos por Arma de Fogo/patologia , Feminino , Gelatina , Humanos , Masculino , Modelos Biológicos , Poliuretanos , Gravação em Vídeo
7.
Int J Legal Med ; 133(5): 1437-1442, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31152277

RESUMO

Most gunshot entrance sites on human victims are localized in clothed body regions. Except for the use of lead-free ammunition, a positive color reaction of the sodium rhodizonate test indicates a primary target hit by the bullet. Any lead residue pattern in the area around the entrance hole allows approximate conclusions as to the firing distance in close and intermediate range shots, whereas the presence of a bullet wipe denotes an entrance site. A criminal case gave rise to an experimental study to clarify whether a blood-soaked garment being shot at as a primary target may lack a bullet wipe around the entrance hole. Distant-range shots were fired with a semi-automatic pistol (Heckler & Koch, Mod. USP Compact, cal. 9-mm Luger) using cartridges with jacketed round-nose bullets and a Sinoxid primer containing lead styphnate. In fabrics saturated with fluid blood, a wide area around the bullet entrance was densely covered with rhodizonate-positive microparticles simulating gunshot residues (GSR) from a close-range shot. In shots to fabrics oversaturated with blood, a typical bullet wipe was lacking, whereas lead-containing particles were spotted in the periphery. The results are discussed with respect to the aberrant appearance of bullet entrance sites in blood-soaked fabrics.


Assuntos
Manchas de Sangue , Balística Forense , Têxteis/análise , Ferimentos por Arma de Fogo/sangue , Cicloexanonas/sangue , Cicloexanonas/química , Armas de Fogo
8.
Int J Legal Med ; 131(5): 1333-1339, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28717964

RESUMO

It is a well-known fact that blank cartridge guns can cause penetrating and even fatal injuries when discharged in contact or at very close ranges. In these cases, the gas jet perforates the skin leaving an entrance wound similar to that from a conventional gun. In order to investigate the wound morphology in contact shots from blank firearms, test shots were fired at composite models of pig skin and gelatin blocks using three different calibre 9-mm blank cartridge handguns (two pistols and one revolver) and two types of ammunition. It turned out that the penetrating gas jet produced roundish skin defects resembling bullet entrance holes. Small skin particles from the perforation site were dispersed in the underlying simulant where radiating cracks containing greyish gunshot residues indicated the original expansion of the inrushing combustion gases. Apart from the size of the permanent entrance hole in the skin and the final position of the displaced tissue particles, the penetration depth of the gas jet was determined. Under the specified conditions of the test shots, the zone of mechanical destruction within the simulant was 2.2 to 6.1 cm in length, which illustrates the injuring potential of contact shots inflicted with blank cartridge handguns.


Assuntos
Armas de Fogo , Balística Forense , Pele/patologia , Ferimentos por Arma de Fogo/patologia , Animais , Gelatina , Humanos , Modelos Animais , Modelos Biológicos , Pele/lesões , Suínos
9.
Int J Legal Med ; 131(2): 441-445, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27909866

RESUMO

To investigate if there is any correlation between the bullet design and the respective dimensions of the abrasion collar and the skin defect in gunshot entrance wounds, experimental studies were performed on dyed pig skin. For the test shots, .38 Special revolver cartridges with three different bullet designs (round nose, wadcutter, and truncated cone) were used. With the help of an image editing program in combination with an image analyzing system, the area size of the abrasion rings and the skin defects was calculated automatically. The measured values differed significantly depending on the bullet type: the abrasion ring areas were largest in shots with round nose bullets and smallest with wadcutter projectiles. With regard to the entrance hole size, the relationship was inverse. The results are discussed with reference to the pertinent literature concerning the dynamic interaction between bullet and skin.


Assuntos
Balística Forense/métodos , Pele/patologia , Ferimentos por Arma de Fogo/patologia , Animais , Modelos Animais , Pele/lesões , Suínos
10.
Int J Legal Med ; 131(6): 1557-1564, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28105494

RESUMO

In humans, most fatalities from slaughterer's guns are suicides committed by persons familiar with stunning devices. The great majority of cases accounts for shots to the head, especially the frontal region. Only a small number of two subsequent cranial shots from captive-bolt humane killers have been reported up to now. In the case presented by the authors, a suicide by simultaneous shots to the head fired from two different makes of captive-bolt guns (one of them having two separate outlets for the combustion gases in the muzzle plane, the other type having no additional openings) is described for the first time. One of the shooting devices remained in firm contact with the left hand and produced patterned staining from rust corresponding to the surface relief of the gun. The medicolegal and criminalistic aspects of this unique case are discussed with reference to the pertinent literature.


Assuntos
Armas de Fogo , Traumatismos Cranianos Penetrantes/patologia , Suicídio , Ferimentos por Arma de Fogo/patologia , Idoso , Desenho de Equipamento , Traumatismos Cranianos Penetrantes/etiologia , Humanos , Masculino , Fuligem
11.
Int J Legal Med ; 130(3): 751-7, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26496804

RESUMO

In contact shots, the muzzle imprint is an informative finding associated with the entrance wound. It typically mirrors the constructional components being in line with the muzzle or just behind. Under special conditions, other patterned skin marks located near a gunshot entrance wound may give the impression to be part of the muzzle imprint. A potential mechanism causing a patterned pressure abrasion in close proximity to the bullet entrance site is demonstrated on the basis of a suicidal shot to the temple. The skin lesion in question appeared as a ring-shaped excoriation with a diameter corresponding to that of the cartridge case. Two hypotheses concerning the causative mechanism were investigated by test shots: - After being ejected, the cartridge case ricocheted inside a confined space (car cabin in the particular case) and secondarily hit the skin near the gunshot entrance wound. - The ejection of the cartridge case failed so that the case became stuck in the ejection port and its mouth contacted the skin when the body collapsed after being hit.


Assuntos
Traumatismos Cranianos Penetrantes/patologia , Suicídio , Ferimentos por Arma de Fogo/patologia , Idoso , Armas de Fogo , Humanos , Masculino
12.
Int J Legal Med ; 129(1): 125-31, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25119685

RESUMO

In modern medico-legal literature, only a small number of publications deal with fatal injuries from black powder guns. Most of them focus on the morphological features such as intense soot soiling, blast tattooing and burn effects in close-range shots or describe the wound ballistics of spherical lead bullets. Another kind of "unusual" and potentially lethal weapons are handguns destined for firing only blank cartridges such as starter and alarm pistols. The dangerousness of these guns is restricted to very close and contact range shots and results from the gas jet produced by the deflagration of the propellant. The present paper reports on a suicide committed with a muzzle-loading percussion pistol cal. 45. An unusually large stellate entrance wound was located in the precordial region, accompanied by an imprint mark from the ramrod and a faint greenish discoloration (apparently due to the formation of sulfhemoglobin). Autopsy revealed an oversized powder cavity, multiple fractures of the anterior thoracic wall as well as ruptures of the heart, the aorta, the left hepatic lobe and the diaphragm. In total, the zone of mechanical destruction had a diameter of approx. 15 cm. As there was no exit wound and no bullet lodged in the body, the injury was caused exclusively by the inrushing combustion gases of the propellant (black powder) comparable with the gas jet of a blank cartridge gun. In contact shots to ballistic gelatine using the suicide's pistol loaded with black powder but no projectile, the formation of a nearly spherical cavity could be demonstrated by means of a high-speed camera. The extent of the temporary cavity after firing with 5 g of black powder roughly corresponded to the zone of destruction found in the suicide's body.


Assuntos
Armas de Fogo , Gases , Pós , Suicídio , Ferimentos por Arma de Fogo/patologia , Diafragma/lesões , Diafragma/patologia , Balística Forense , Gelatina , Ruptura Cardíaca/patologia , Humanos , Fígado/lesões , Fígado/patologia , Pessoa de Meia-Idade , Modelos Biológicos , Traumatismos Torácicos/patologia
13.
Arch Kriminol ; 236(3-4): 115-29, 2015.
Artigo em Alemão | MEDLINE | ID: mdl-26548036

RESUMO

On 30 Jan 2015, two avalanche accidents happened in the Black Forest (at the foot of the 1493 m high Feldberg and the Herzogenhorn situated next to it), in which experienced ski tourers--a 58-year-old woman and a 20-year-old man--were completely buried by snow masses. Both victims were recovered dead after nearly 2 hours under the snow. The avalanches were promoted by strong snowfalls, snowdrift by the wind and steep downwind slopes. One of the victims, the 20-year-old man, underwent a forensic autopsy. The findings suggested death by protracted asphyxiation with agonal hypothermia. A mechanical traumatization with internal injuries suspected by the emergency doctor at the scene could not be confirmed at autopsy. The possible causes of death in the avalanche are discussed using the reported case as an example and in reference to the relevant literature.


Assuntos
Asfixia/diagnóstico , Avalanche , Patologia Legal/métodos , Traumatismo Múltiplo/diagnóstico , Adulto , Altitude , Asfixia/complicações , Evolução Fatal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismo Múltiplo/complicações
14.
Arch Kriminol ; 236(3-4): 73-84, 2015.
Artigo em Alemão | MEDLINE | ID: mdl-26548032

RESUMO

On 26 Nov 2012, a serious fire occurred at Neustadt/Black Forest in which 14 persons in a sheltered workshop died and 10 other individuals were injured. The fire was caused by the unbridled escape of propane gas due to accidental disconnection of the screw fixing between a gas bottle and a catalytic heater. Deflagration of the propane gas-air mixture set the workshop facilities on fire. In spite of partly extensive burns the fatally injured victims could be rapidly identified. The results of the fire investigations at the scene and the autopsy findings are presented. Carboxyhemoglobin concentrations ranged between 8 and 56 % and signs of fire fume inhalation were present in all cases. Three victims had eardrum ruptures due to the sudden increase in air pressure during the deflagration.


Assuntos
Traumatismos por Explosões/patologia , Queimaduras/patologia , Explosões/classificação , Incêndios , Traumatismo Múltiplo/patologia , Propano , Ar , Medicina Legal/métodos , Alemanha , Humanos
15.
Int J Legal Med ; 128(2): 313-6, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24429766

RESUMO

Suicidal ligature strangulation is a rare event. The most important issue to solve in the investigation is whether it is a case of homicide or suicide. The characteristics of suicidal ligature strangulation are summarized by Koops and Brinkmann with the emphasis on the nature of the ligature instrument(s). In this article, we present two cases of self-strangulation with an almost identical modus operandi using gymnastics bands. The autopsy findings and the nature of the ligature in these cases are depicted and in good accordance with the described typical observations in suicidal cases. The importance of a broad medico-legal investigation is demonstrated.


Assuntos
Obstrução das Vias Respiratórias/patologia , Asfixia/patologia , Ginástica , Lesões do Pescoço/patologia , Equipamentos Esportivos , Suicídio/legislação & jurisprudência , Idoso , Desenho de Equipamento , Feminino , Hemorragia/patologia , Humanos , Ligadura , Masculino , Pessoa de Meia-Idade , Músculos do Pescoço/lesões , Músculos do Pescoço/patologia
16.
J Pharm Biomed Anal ; 240: 115959, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38183731

RESUMO

BACKGROUND AND AIM: This case involves a 20-year-old man with prior hallucinogen-use experience, who sniffed an unknown amount of dipropyltryptamine in an apartment. Dipropyltryptamine, a hallucinogenic compound belonging to the tryptamine class is recognized for inducing effects similar to dimethyltryptamine (DMT) but with a longer duration. Ten to fifteen minutes later he experienced visual hallucinations, followed by increasing apathy. Two hours post consumption he developed abdominal pain, leading to collapse, seizure, and vomiting. Despite emergency medical resuscitation on site, transport to hospital 2.5 hours post consumption and extracorporeal life support he died 21 hours later. Relevant toxicological and morphological findings are presented. METHODS: A serum sample was collected four hours post consumption. Autopsy was performed six days after death. Antemortem serum, as well as postmortem cardiac blood and urine were analyzed for alcohol and psychoactive drugs by systematic toxicological analyses employing gas chromatography-mass spectrometry (Maurer/Pfleger/Weber library among others), liquid chromatography-ion trap mass spectrometry (LC-MSn, Toxtyper™), and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Dipropyltryptamine was quantified by LC-MS/MS after solid-phase extraction. RESULTS: Autopsy revealed a state after deep aspiration of gastric contents with consecutive brain edema due to oxygen deprivation. Dipropyltryptamine concentrations were approximately 210 ng/ml, 110 ng/ml and 180 ng/ml in antemortem serum, postmortem cardiac blood and urine, respectively. To the best of our knowledge, these are the first reported concentrations of dipropyltryptamine in a fatal case. CONCLUSION: Unlike typical tryptamine overdose reports, this case did not present with agitation, hyperthermia, or tachycardia. Despite the individual's prior experience with tryptamines and the generally low toxicity associated with this class of hallucinogens, death in this case was an indirect consequence of the nasal consumption of a high dose of dipropyltryptamine.


Assuntos
Espectrometria de Massas em Tandem , Triptaminas , Masculino , Humanos , Adulto Jovem , Adulto , Cromatografia Líquida , Triptaminas/efeitos adversos
17.
Int J Legal Med ; 127(4): 791-7, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23250385

RESUMO

In current forensic practice, fatal injuries from black powder guns are rare events. In contact and close-range shots, the intensity of GSR deposition (soot, powder particles) is much greater than that in shots with smokeless powder ammunition. The same applies to any burning effects from the combustion gases. Besides, a wad of felt interposed between the propellant and the lead bullet may enter the wound channel. Apart from these findings seen in close-range shots, another characteristic feature results from the mostly spherical shape of the missiles causing maximum tissue damage at the entrance site. Two fatal injuries inflicted with muzzle-loading weapons are reported. In the first case, suicide was committed with a cal. 11.6 mm miniature cannon by firing a contact shot to the back of the neck. In test shots using black powder (1 and 2 g) as propellant, the mean bullet velocity measured 1 m away from the weapon was 87.11 and 146.85 m/s, respectively, corresponding to a kinetic energy of 32.49 and 92.95 J, respectively. Contact test shots to composite models consisting of ballistic soap covered by pig skin at the entrance site were evaluated by CT and revealed cone-like cavitations along the bullet path as known from spherical missiles and penetration depths up to 25 cm. The second case presented deals with a homicidal close-range shot discharged from a muzzle-loading percussion pistol cal. .44. The skin around the entrance site (root of the nose) was densely covered with blackish soot and powder particles, whereas the eyebrows and eyelashes showed singeing of the hairs. The flattened bullet and the wad had got stuck under the scalp of the occipital region. In both cases, there was a disproportionally large zone of tissue destruction in the initial parts of the wound tracks.


Assuntos
Armas de Fogo , Modelos Biológicos , Ferimentos por Arma de Fogo/patologia , Idoso , Animais , Desenho de Equipamento , Balística Forense , Patologia Legal , Homicídio , Humanos , Masculino , Pessoa de Meia-Idade , Pele/lesões , Pele/patologia , Sabões , Fuligem , Suicídio , Suínos
18.
Int J Legal Med ; 127(5): 931-6, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23700297

RESUMO

To study the question whether and how the size and position of the temporary cavity influence the morphology and especially the size of a bullet exit wound, test shots were fired to composite models consisting of gelatine and pig soft tissue covered with skin (at the exit site). The dimensions of the composite model were determined such that the exit planes were located either at the level of the narrow channel or within the temporary cavity or behind it. The chronological sequence of wound formation and its relation to the current position of the bullet were documented by means of a high-speed camera. Test shots were fired from a distance of 10 m using 5.56 × 45 mm cartridges with full metal-jacketed pointed bullets (v 0 ∼ 912 m/s, E 0 ∼ 1,663 J). The study proved that the extension and position of the temporary wound cavity was decisive for the size of the exit wound: An exit plane within the cavity resulted in particularly large skin lesions, whereas the wound diameters were much smaller if the exit plane was located in front or behind the cavity. The exit hole reaches its maximum size only after the bullet has left the target synchronous to the staggered expansion of the temporary cavity.


Assuntos
Balística Forense , Ferimentos por Arma de Fogo/patologia , Animais , Armas de Fogo , Gelatina , Modelos Animais , Modelos Biológicos , Pele/lesões , Pele/patologia , Sabões , Suínos
19.
Arch Kriminol ; 231(5-6): 183-92, 2013.
Artigo em Alemão | MEDLINE | ID: mdl-23878897

RESUMO

Report on the clinical and medicolegal findings in a survived suicide attempt by hanging. A 39-year-old woman was found unconscious in a crouching position on the balcony of her flat. The hanging device was an electric cable running around her neck in a single loop and attached to the balcony wall. After removing the noose, resuscitation measures were started immediately. For 5 hours, the victim was at first in a comatose and then in a somnolent state. The period of amnesia covered also the preparations for the suicidal act. The forensic examination performed on the same day showed a reddish, streak-like hanging mark, pronounced signs of blood congestion with dense petechial haemorrhages in the facial skin, confluent haemorrhages in the conjunctivae as well as bleeding from the left external auditory canal. BAC was 2.2 per mil. On the basis of the findings and the clinical course, criminalistic and pathophysiological aspects of near-hanging are discussed.


Assuntos
Asfixia/patologia , Lesões do Pescoço/patologia , Tentativa de Suicídio/legislação & jurisprudência , Adulto , Diagnóstico Diferencial , Prova Pericial/legislação & jurisprudência , Feminino , Escala de Coma de Glasgow , Homicídio/legislação & jurisprudência , Humanos , Exame Neurológico , Pele/lesões , Pele/patologia
20.
Arch Kriminol ; 231(5-6): 175-82, 2013.
Artigo em Alemão | MEDLINE | ID: mdl-23878896

RESUMO

Intoxications in children still account for a large part of the cases reported to poison control centres. Among drug intoxications, substitution drugs have gained in importance lately. Careless storage of take-home medications puts children living in the same household at risk. The authors report on a fatal case of a 10-year-old girl who died from intoxication with methadone belonging to a carer. The accidental intoxication had not been diagnosed at the hospital where the girl was treated for suspected meningitis. The question of medical malpractice is discussed.


Assuntos
Acidentes Domésticos/legislação & jurisprudência , Analgésicos Opioides/intoxicação , Metadona/intoxicação , Analgésicos Opioides/uso terapêutico , Autopsia , Encéfalo/patologia , Criança , Dor Crônica/reabilitação , Erros de Diagnóstico/legislação & jurisprudência , Feminino , Humanos , Pulmão/patologia , Meningites Bacterianas/diagnóstico , Meningites Bacterianas/patologia , Metadona/uso terapêutico , Transtornos Relacionados ao Uso de Opioides/reabilitação , Músculos Papilares/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA