Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Pacing Clin Electrophysiol ; 39(7): 633-41, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27019211

RESUMO

BACKGROUND: Different types of ventricular arrhythmias (monomorphic ventricular tachycardia [VT], polymorphic VT, or ventricular fibrillation) can be detected by implantable cardiac defibrillators (ICDs) in fast VT zone. The efficacy of antitachycardia pacing (ATP) depends on the type of the treated arrhythmia. We hypothesized that an automatic algorithm based on morphological affinity of ICD far-field electrograms during tachycardia can predict ATP success and the need of shock. METHODS: The algorithm was evaluated on ventricular arrhythmias recorded in CareLink ICD remote monitoring system (Medtronic Inc., Minneapolis, MN, USA). Patients were selected if first ATP programmed was a burst of eight pulses at 88% coupling interval and if a far-field electrogram was available. The algorithm calculated a stability coefficient (SC) for all their stored ATP-treated fast ventricular arrhythmia (VA) episodes (LC 200-300 ms), analyzing the morphology homogeneity of the last eight recorded far-field electrograms before ventricular arrhythmias detection. RESULTS: Inclusion criteria were fulfilled by 717 patients from 29 centers. Three hundred and twenty fast VA were recorded in 103 patients. A higher SC was observed in episodes terminated with the first-ATP (0.78 [0.72-0.84] vs 0.74 [0.60-0.84]; P = 0.006). These differences were especially marked among the 62 episodes of very fast VA (CL ≤250 ms) (0.77 [0.74-0.85] vs 0.64 [0.51-0.8]; P = 0.006). In the multivariate analysis, a SC > 70% was independently associated with a higher likelihood of first-ATP success (odds ratio [OR] = 2.5; [95% confidence interval (CI) = 1.4-4.5], P = 0.001) and a lower need of shock (OR = 0.37; [95% CI = 0.2-0.7], P = 0.002). CONCLUSION: This automatic algorithm (stability coefficient) shows that ATP therapy response can be predicted in fast ventricular arrhythmias through morphology evaluation.


Assuntos
Algoritmos , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/prevenção & controle , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/prevenção & controle , Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Diagnóstico por Computador/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/métodos , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espanha , Terapia Assistida por Computador/métodos , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 26(7): 774-82, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25916814

RESUMO

INTRODUCTION: An empirical sequence of burst antitachycardia pacing (ATP) is effective in terminating fast ventricular tachycardias (FVT) in patients with implantable cardioverter-defibrillators (ICDs). We aimed to determine whether multiple ATP bursts for termination of FVT results in shock reduction compared to a single ATP burst. METHODS AND RESULTS: We analyzed data from the Umbrella trial, a multicenter prospective observational study of ICD patients followed by the CareLink Monitoring System. We compared the safety and effectiveness of a single ATP burst (Group 1) with a strategy of successive ATP sequences (Group 2) for termination of FVT episodes (cycle lengths 250-320 milliseconds) before shock therapy. Over a mean follow-up of 35 months, a total of 650 FVT episodes were detected in 154 patients (mean cycle length: 299 ± 18 milliseconds). Effectiveness of the first burst ATP in Group 1 was 73% and shocks were required in 27% of episodes. Effectiveness of the first burst ATP in Group 2 was 77%, and this increased to 91% with the third or successive ATP bursts. Shocks were required in 9% of episodes in group 2, representing a 67% reduction in the need of high-energy shocks. Median duration of FVT episodes and mortality in both groups were similar. Multivariate analysis indicated that programming multiple ATP bursts (OR 3.4, 95%CI 1.7-6.8, P = 0.001) was an independent predictor of ATP effectiveness. CONCLUSION: This study provides first evidence that a strategy of multiple burst ATP sequences for termination of FVT episodes leads to a clinically meaningful reduction in the need for shocks.


Assuntos
Estimulação Cardíaca Artificial/métodos , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Traumatismos por Eletricidade/prevenção & controle , Taquicardia Ventricular/terapia , Potenciais de Ação , Idoso , Estimulação Cardíaca Artificial/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Traumatismos por Eletricidade/diagnóstico , Traumatismos por Eletricidade/etiologia , Traumatismos por Eletricidade/fisiopatologia , Desenho de Equipamento , Falha de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Espanha , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
3.
Rev Esp Cardiol (Engl Ed) ; 71(9): 709-717, 2018 Sep.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29242102

RESUMO

INTRODUCTION AND OBJECTIVES: Fast ventricular tachycardias in the ventricular fibrillation zone in patients with an implantable cardioverter-defibrillator are susceptible to antitachycardia pacing (ATP) termination. Some manufacturers allow programming 2 ATP bursts: before charging (BC) and during (DC) charging. The aim of this study was to describe the safety and effectiveness of ATP BC and DC for fast ventricular tachycardias in the ventricular fibrillation zone in patients with an implantable cardioverter-defibrillator in daily clinical practice. METHODS: Data proceeded from the multicenter UMBRELLA trial, including implantable cardioverter-defibrillator patients followed up by the CareLink monitoring system. Fast ventricular tachycardias in the ventricular fibrillation zone until a cycle length of 200ms with ATP BC and/or ATP DC were included. RESULTS: We reviewed 542 episodes in 240 patients. Two ATP bursts (BC/DC) were programmed in 291 episodes (53.7%, 87 patients), while 251 episodes (46.3%, 153 patients) had 1 ATP burst only DC. The number of episodes terminated by 1 ATP DC was 139, representing 55.4% effectiveness (generalized estimating equation-adjusted 60.4%). There were 256 episodes terminated by 1 or 2 ATP (BC/DC), representing 88% effectiveness (generalized estimating equation-adjusted 79.3%); the OR for ATP effectiveness BC/DC vs DC was 2.5, 95%CI, 1.5-4.1; P <.001. Shocked episodes were 112 (45%) for ATP DC vs 35 (12%) for ATP BC/DC, representing an absolute reduction of 73%. The mean shocked episode duration was 16seconds for ATP DC vs 19seconds for ATP BC/DC (P=.07). CONCLUSIONS: The ATP DC in the ventricular fibrillation zone for fast ventricular tachycardia is moderately effective. Adding an ATP burst BC increases the overall effectiveness, reduces the need for shocks, and does not prolong episode duration.


Assuntos
Algoritmos , Estimulação Cardíaca Artificial/métodos , Desfibriladores Implantáveis , Eletrocardiografia , Taquicardia Ventricular/terapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
4.
PLoS One ; 11(9): e0163514, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27684715

RESUMO

PURPOSE: Brugada syndrome (BrS) is a form of cardiac arrhythmia which may lead to sudden cardiac death. The recommended genetic testing (direct sequencing of SCN5A) uncovers disease-causing SNVs and/or indels in ~20% of cases. Limited information exists about the frequency of copy number variants (CNVs) in SCN5A in BrS patients, and the role of CNVs in BrS-minor genes is a completely unexplored field. METHODS: 220 BrS patients with negative genetic results were studied to detect CNVs in SCN5A. 63 cases were also screened for CNVs in BrS-minor genes. Studies were performed by Multiplex ligation-dependent probe amplification or Next-Generation Sequencing (NGS). RESULTS: The detection rate for CNVs in SCN5A was 0.45% (1/220). The detected imbalance consisted of a duplication from exon 15 to exon 28, and could potentially explain the BrS phenotype. No CNVs were found in BrS-minor genes. CONCLUSION: CNVs in current BrS-related genes are uncommon among BrS patients. However, as these rearrangements may underlie a portion of cases and they undergo unnoticed by traditional sequencing, an appealing alternative to conventional studies in these patients could be targeted NGS, including in a single experiment the study of SNVs, indels and CNVs in all the known BrS-related genes.

5.
Pacing Clin Electrophysiol ; 27(11): 1563-5, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15546314

RESUMO

Oversensing of electrical signals in recipients of ICDs is a common complication causing the delivery of inappropriate therapy. The Brugada syndrome has a characteristic ECG pattern with dynamic temporal changes in response to various physiological or environmental conditions. This case report presents a patient with the Brugada syndrome and intermittent T wave oversensing by an ICD due to changes in T wave amplitude which could not be resolved by device reprogramming and required repositioning of the electrode.


Assuntos
Bloqueio de Ramo/fisiopatologia , Desfibriladores Implantáveis , Eletrocardiografia , Idoso , Desenho de Equipamento , Falha de Equipamento , Humanos , Masculino , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo
6.
Pacing Clin Electrophysiol ; 25(11): 1646-8, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12494626

RESUMO

This case report describes a 66-year-old woman with severe polymorphic ventricular tachycardia and syncope during a febrile state. The electrocardiogram revealed a right bundle branch block and pattern of elevated ST segment in the anterior and inferior leads similar to the Brugada syndrome. These electrocardiographic anomalies disappeared when the temperature returned to normal. The administration of procainamide reproduced the electrocardiographic changes. An electrophysiological study using two extrastimuli induced ventricular tachycardia. An automatic defibrillator was implanted.


Assuntos
Bloqueio de Ramo/diagnóstico , Morte Súbita Cardíaca , Febre/etiologia , Idoso , Bloqueio de Ramo/complicações , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia , Feminino , Humanos , Síndrome
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA