Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Med Biol ; 69(11)2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38657625

RESUMO

Objective.The superior dose conformity provided by proton therapy relative to conventional x-ray radiotherapy necessitates more rigorous quality assurance (QA) procedures to ensure optimal patient safety. Practically however, time-constraints prevent comprehensive measurements to be made of the proton range in water: a key parameter in ensuring accurate treatment delivery.Approach.A novel scintillator-based device for fast, accurate water-equivalent proton range QA measurements for ocular proton therapy is presented. Experiments were conducted using a compact detector prototype, the quality assurance range calorimeter (QuARC), at the Clatterbridge cancer centre (CCC) in Wirral, UK for the measurement of pristine and spread-out Bragg peaks (SOBPs). The QuARC uses a series of 14 optically-isolated 100 × 100 × 2.85 mm polystyrene scintillator sheets, read out by a series of photodiodes. The detector system is housed in a custom 3D-printed enclosure mounted directly to the nozzle and a numerical model was used to fit measured depth-light curves and correct for scintillator light quenching.Main results.Measurements of the pristine 60 MeV proton Bragg curve found the QuARC able to measure proton ranges accurate to 0.2 mm and reduced QA measurement times from several minutes down to a few seconds. A new framework of the quenching model was deployed to successfully fit depth-light curves of SOBPs with similar range accuracy.Significance.The speed, range accuracy and simplicity of the QuARC make the device a promising candidate for ocular proton range QA. Further work to investigate the performance of SOBP fitting at higher energies/greater depths is warranted.


Assuntos
Calorimetria , Calorimetria/instrumentação , Controle de Qualidade , Terapia com Prótons/instrumentação , Humanos
2.
Med Phys ; 48(9): 5202-5218, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34174092

RESUMO

PURPOSE: Relative stopping powers (RSPs) for proton therapy are estimated using single-energy computed tomography (SECT), calibrated with standardized tissues of the adult male. It is assumed that those tissues are representative of tissues of all age and sex. Female, male, and pediatric tissues differ from one another in density and composition. In this study, we use tabulated pediatric tissues and computational phantoms to investigate the impact of this assumption on pediatric proton therapy. The potential of dual-energy CT (DECT) to improve the accuracy of these calculations is explored. METHODS: We study 51 human body tissues, categorized into male/female for the age groups newborn, 1-, 5-, 10-, and 15-year-old children, and adult, with given compositions and densities. CT numbers are simulated and RSPs are estimated using SECT and DECT methods. Estimated tissue RSPs from each method are compared to theoretical RSPs. The dose and range errors of each approach are evaluated on three computational phantoms (Ewing's sarcoma, salivary sarcoma, and glioma) derived from pediatric proton therapy patients. RESULTS: With SECT, soft tissues have mean estimation errors and standard deviation up to (1.96 ± 4.18)% observed in newborns, compared to (0.20 ± 1.15)% in adult males. Mean estimation errors for bones are up to (-3.35 ± 4.76)% in pediatrics as opposed to (0.10 ± 0.66)% in adult males. With DECT, mean errors reduce to (0.17 ± 0.13)% and (0.23 ± 0.22)% in newborns (soft tissues/bones). With SECT, dose errors in a Ewing's sarcoma phantom are exceeding 5 Gy (10% of prescribed dose) at the distal end of the treatment field, with volumes of dose errors >5 Gy of V diff > 5 = 4630.7  mm3 . Similar observations are made in the head and neck phantoms, with overdoses to healthy tissue exceeding 2 Gy (4%). A systematic Bragg peak shift resulting in either over- or underdosage of healthy tissues and target volumes depending on the crossed tissues RSP prediction errors is observed. Water equivalent range errors of single beams are between -1.53 and 5.50 mm (min, max) (Ewing's sarcoma phantom), -0.78 and 3.62 mm (salivary sarcoma phantom), and -0.43 and 1.41 mm (glioma phantom). DECT can reduce dose errors to <1 Gy and range errors to <1 mm. CONCLUSION: Single-energy computed tomography estimates RSPs for pediatric tissues with systematic shifts. DECT improves the accuracy of RSPs and dose distributions in pediatric tissues compared to the SECT calibration curve based on adult male tissues.


Assuntos
Pediatria , Terapia com Prótons , Calibragem , Criança , Feminino , Humanos , Recém-Nascido , Masculino , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
3.
Br J Radiol ; 89(1058): 20150603, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26585543

RESUMO

OBJECTIVE: To determine if subsets of patients may benefit from smaller or larger margins when using laser setup and bony anatomy verification of breast tumour bed (TB) boost radiotherapy (RT). METHODS: Verification imaging data acquired using cone-beam CT, megavoltage CT or two-dimensional kilovoltage imaging on 218 patients were used (1574 images). TB setup errors for laser-only setup (dlaser) and for bony anatomy verification (dbone) were determined using clips implanted into the TB as a gold standard for the TB position. Cases were grouped by centre-, patient- and treatment-related factors, including breast volume, TB position, seroma visibility and surgical technique. Systematic (Σ) and random (σ) TB setup errors were compared between groups, and TB planning target volume margins (MTB) were calculated. RESULTS: For the study population, Σlaser was between 2.8 and 3.4 mm, and Σbone was between 2.2 and 2.6 mm, respectively. Females with larger breasts (p = 0.03), easily visible seroma (p ≤ 0.02) and open surgical technique (p ≤ 0.04) had larger Σlaser. Σbone was larger for females with larger breasts (p = 0.02) and lateral tumours (p = 0.04). Females with medial tumours (p < 0.01) had smaller Σbone. CONCLUSION: If clips are not used, margins should be 8 and 10 mm for bony anatomy verification and laser setup, respectively. Individualization of TB margins may be considered based on breast volume, TB and seroma visibility. ADVANCES IN KNOWLEDGE: Setup accuracy using lasers and bony anatomy is influenced by patient and treatment factors. Some patients may benefit from clip-based image guidance more than others.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Tomografia Computadorizada de Feixe Cônico/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Posicionamento do Paciente , Fótons , Interpretação de Imagem Radiográfica Assistida por Computador , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Reino Unido
4.
Radiother Oncol ; 103(2): 166-71, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22521748

RESUMO

PURPOSE: This study investigates (i) the effect of verification protocols on treatment accuracy and PTV margins for partial breast and boost breast radiotherapy with short fractionation schema (15 fractions), (ii) the effect of deformation of the excision cavity (EC) on PTV margin size, (iii) the imaging dose required to achieve specific PTV margins. METHODS AND MATERIALS: Verification images using implanted EC markers were studied in 36 patients. Target motion was estimated for a 15 fraction partial breast regimen using imaging protocols based on on-line and off-line motion correction strategies (No Action Level (NAL) and the extended NAL (eNAL) protocols). Target motion was used to estimate a PTV margin for each protocol. To evaluate treatment errors due to deformation of the excision cavity, individual marker positions were obtained from 11 patients. The mean clip displacement and daily variation in clip position during radiotherapy were determined and the contribution of these errors to PTV margin calculated. Published imaging dose data were used to estimate total dose for each protocol. Finally the number of images required to obtain a specific PTV margin was evaluated and hence, the relationship between PTV margins and imaging dose was investigated. RESULTS: The PTV margin required to account for excision cavity motion, varied between 10.2 and 2.4mm depending on the correction strategy used. Average clip movement was 0.8mm and average variation in clip position during treatment was 0.4mm. The contribution to PTV margin from deformation was estimated to be small, less than 0.2mm for both off-line and on-line correction protocols. CONCLUSION: A boost or partial breast PTV margin of ∼10 mm, is possible with zero imaging dose and workload, however, patients receiving boost radiotherapy may benefit from a margin reduction of ∼4 mm with imaging doses from 0.4cGy to 25cGy using an eNAL protocol. PTV margin contributions from deformation errors are likely to be small in comparison to other sources of error, i.e., set up or delineation.


Assuntos
Neoplasias da Mama/radioterapia , Radioterapia Guiada por Imagem , Neoplasias da Mama/patologia , Fracionamento da Dose de Radiação , Feminino , Humanos , Movimento (Física)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA