Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Orthod Craniofac Res ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38712682

RESUMO

OBJECTIVE: We propose a method utilizing mixed reality (MR) goggles (HoloLens 2, Microsoft) to facilitate impacted canine alignment, as planning the traction direction and force delivery could benefit from 3D data visualization using mixed reality (MR). METHODS: Cone-beam CT scans featuring isometric resolution and low noise-to-signal ratio were semi-automatically segmented in Inobitec software. The exported 3D mesh (OBJ file) was then optimized for the HoloLens 2. Using the Unreal Engine environment, we developed an application for the HoloLens 2, implementing HoloLens SDK and UX Tools. Adjustable pointers were added for planning attachment placement, traction direction, and point of force application. The visualization was presented to participants of a course on impacted teeth treatment, followed by a 10-question survey addressing potential advantages (5-point scale: 1 = totally agree, 5 = totally disagree). RESULTS: Out of 38 respondents, 44.7% were orthodontists, 34.2% dentists, 15.8% dental students, and 5.3% dental technicians. Most respondents (44.7%) were between 35 and 44 years old, and only 1 (2.6%) respondent was 55-64 years old. Median answers for six questions were 'totally agree' (25th percentile 1, 75th percentile 2) and for four questions 'agree' (25th percentile 1, 75th percentile 2). No correlation was found between age, profession, and responses. CONCLUSION: Our method generated substantial interest among clinicians. The initial responses affirm the potential benefits, supporting the continued exploration of MR-based techniques for the treatment of impacted teeth. However, the recommendation for widespread use awaits validation through clinical trials.

2.
J Electrocardiol ; 76: 45-54, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36436474

RESUMO

BACKGROUND: The QRS, ST segment, and T-wave waveforms of electrocardiogram are difficult to interpret, especially for non-ECG experts readers, like general practitioners. As the ECG waveforms are influenced by many factors, like body build, age, sex, electrode placement, even for experience ECG readers the waveform is difficult to interpret. In this research we have created a novel method to distinguish normal from abnormal ECG waveforms for an individual ECG based on the ECG amplitude distribution derived from normal standard 12­lead ECG recordings. AIM: Creation of a normal ECG amplitude distribution to enable the distinction by non-ECG experts of normal from abnormal waveforms of the standard 12­lead ECG. METHODS: The ECGs of healthy normal controls in the PTB-XL database were used to construct a normal amplitude distribution of the 12 lead ECG for males and females. All ECGs were resampled to have the same number of samples to enable the classification of an individual ECG as either normal or abnormal, i.e. within the normal amplitude distribution or outside, the ΔWaveECG. RESULTS: From the same PTB-XL database six ECG's were selected, normal, left and right bundle branch block, and three with a myocardial infarction. The normal ECG was obviously within the normal distribution, and all other five showed clear abnormal ECG amplitudes outside the normal distribution in any of the ECG segments (QRS, ST segment and remaining STT segment). CONCLUSION: The ΔWaveECG can distinguish the abnormal from normal ECG waveform segments, making the ECG easier to classify as normal or abnormal. Conduction disorders and ST changes due to ischemia and abnormal T-waves are effortless to detect, also by non-ECG expert readers, thus improving the early detection of cardiac patients.


Assuntos
Eletrocardiografia , Infarto do Miocárdio , Masculino , Feminino , Humanos , Eletrocardiografia/métodos , Infarto do Miocárdio/diagnóstico , Arritmias Cardíacas/diagnóstico , Bloqueio de Ramo , Eletrodos
3.
Sensors (Basel) ; 21(20)2021 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-34696146

RESUMO

Diabetic retinopathy (DR) is a diabetes disorder that disturbs human vision. It starts due to the damage in the light-sensitive tissues of blood vessels at the retina. In the beginning, DR may show no symptoms or only slight vision issues, but in the long run, it could be a permanent source of impaired vision, simply known as blindness in the advanced as well as in developing nations. This could be prevented if DR is identified early enough, but it can be challenging as we know the disease frequently shows rare signs until it is too late to deliver an effective cure. In our work, we recommend a framework for severity grading and early DR detection through hybrid deep learning Inception-ResNet architecture with smart data preprocessing. Our proposed method is composed of three steps. Firstly, the retinal images are preprocessed with the help of augmentation and intensity normalization. Secondly, the preprocessed images are given to the hybrid Inception-ResNet architecture to extract the vector image features for the categorization of different stages. Lastly, to identify DR and decide its stage (e.g., mild DR, moderate DR, severe DR, or proliferative DR), a classification step is used. The studies and trials have to reveal suitable outcomes when equated with some other previously deployed approaches. However, there are specific constraints in our study that are also discussed and we suggest methods to enhance further research in this field.


Assuntos
Retinopatia Diabética , Cegueira , Retinopatia Diabética/diagnóstico por imagem , Fundo de Olho , Humanos , Projetos de Pesquisa , Retina/diagnóstico por imagem
4.
Folia Med Cracov ; 61(4): 45-54, 2021 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-35180201

RESUMO

Three-dimensional (3D) printed model of the renal vasculature shows a high level of accuracy of subsequent divisions of both the arterial and the venous tree. However, minor artifacts appeared in the form of oval endings to the terminal branches of the vascular tree, contrary to the anticipated sharply pointed segments. Unfortunately, selective laser sintering process does not currently permit to present the arterial, venous and urinary systems in distinct colors, hence topographic relationship between the vascular and the pelvicalyceal systems is difficult to attain. Nonetheless, the 3D printed model can be used for educational purposes to demonstrate the vast renal vasculature and may also serve as a reference model whilst evaluating morphological anomalies of the intrarenal vasculature in a surgical setting.


Assuntos
Artefatos , Rim , Molde por Corrosão , Humanos , Imageamento Tridimensional/métodos , Rim/diagnóstico por imagem , Tecnologia , Microtomografia por Raio-X
5.
Catheter Cardiovasc Interv ; 96(1): E1-E7, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31343827

RESUMO

BACKGROUND: There is paucity of data on acute performance of Fantom (REVA Medical, CA), a second generation sirolimus-eluting bioresorbable scaffold (BRS), in ST-segment elevation myocardial infarction (STEMI) patients undergoing primary percutaneous coronary intervention. The aim of this study was to evaluate safety and efficacy of the Fantom BRS in the acute setting of STEMI characterized by thrombogenic milieu. METHODOLOGY: Ten STEMI patients treated with a sirolimus-eluting Fantom BRS were enrolled into prospective, observational study. The scaffold sizing, positioning, and optimization were optical coherence tomography (OCT) guided. The primary end-point was the device-oriented composite endpoint (DOCE), additionally angiographic and OCT analysis were performed. RESULTS: The primary-end point, defined as DOCE, did not occur in any patient within the 30-day follow-up. The procedural and angiographic success rates were both 100%, there was no case of scaffold thrombosis, target lesion revascularization nor death. In QCA, an in-device minimum lumen diameter was 2.89 ± 0.24 mm and the residual diameter stenosis was 3.56 ± 3.17%. OCT revealed an incomplete scaffold apposition in five patients with an average of seven malapposed struts per scaffold and mean distance of 120 ± 30 µm. There was no proximal edge dissection, the distal edge dissection was recorded in one patient. CONCLUSIONS: This is the first pilot study evaluating safety and efficacy of the Fantom BRS, a second generation fully bioresorbable coronary scaffold, in STEMI patients undergoing primary PCI with OCT guidance. Fantom BRS showed adequate safety and efficacy in the acute 30-day angiographic, OCT, and clinical follow-up.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Intervenção Coronária Percutânea/instrumentação , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica , Idoso , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 94(1): 149-156, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30945420

RESUMO

OBJECTIVES: To assess feasibility, safety, angiographic, and clinical outcome of highly-calcific carotid stenosis (HCCS) endovascular management using CGuard™ dual-layer carotid stents. BACKGROUND: HCCS has been a challenge to carotid artery stenting (CAS) using conventional stents. CGuard combines a high-radial-force open-cell frame conformability with MicroNet sealing properties. METHODS: The PARADIGM study is prospectively assessing routine CGuard use in all-comer carotid revascularization patients; the focus of the present analysis is HCCS versus non-HCCS lesions. Angiographic HCCS (core laboratory evaluation) required calcific segment length to lesion length ≥2/3, minimal calcification thickness ≥3 mm, circularity (≥3 quadrants), and calcification severity grade ≥3 (carotid calcification severity scoring system [CCSS]; G0-G4). RESULTS: One hundred and one consecutive patients (51-86 years, 54.4% symptomatic; 106 lesions) received CAS (16 HCCS and 90 non-HCCS); eight others (two HCCS) were treated surgically. CCSS evaluation was reproducible, with weighted kappa (95% CI) of 0.73 (0.58-0.88) and 0.83 (0.71-0.94) for inter- and intra-observer reproducibility respectively. HCCS postdilatation pressures were higher than those in non-HCCS; 22 (20-24) versus 20 (18-24) atm, p = .028; median (Q1-Q3). Angiography-optimized HCCS-CAS was feasible and free of contrast extravasation or clinical complications. Overall residual diameter stenosis was single-digit but it was higher in HCCS; 9 (4-17) versus 3 (1-7) %, p = .002. At 30 days and 12 months HCCS in-stent velocities were normal and there were no adverse clinical events. CONCLUSION: CGuard HCCS endovascular management was feasible and safe. A novel algorithm to grade carotid artery calcification severity was reproducible and applicable in clinical study setting. Larger HCCS series and longer-term follow-up are warranted.


Assuntos
Estenose das Carótidas/terapia , Procedimentos Endovasculares/instrumentação , Stents , Acidente Vascular Cerebral/prevenção & controle , Calcificação Vascular/terapia , Idoso , Idoso de 80 Anos ou mais , Angiografia , Doenças Assintomáticas , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/mortalidade , Procedimentos Endovasculares/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/complicações , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/mortalidade
7.
Catheter Cardiovasc Interv ; 86(4): E180-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26015294

RESUMO

OBJECTIVES: The aim of the study was to evaluate the healing process at 12 months after ABSORB™ bioresorbable vascular scaffold (BVS) implantation in patients with ST-segment elevation myocardial infarction (STEMI). BACKGROUND: There is currently no data on long-term BVS performance in the acute thrombotic setting. The underlying altered plaque pathomorphology may impact the neointima healing pattern, potentially making it different to that observed in stable coronary artery disease (CAD). METHODS: We have performed an angiographic and optical coherence tomography (OCT) 12-month follow-up of 19 STEMI patients who were treated with a BVS implantation (23 scaffolds). An independent core laboratory performed a paired analysis of the corresponding frames at baseline and follow-up. RESULTS: At 12 months, the OCT follow-up showed a decrease in the mean lumen area (8.29 ± 1.53 mm(2) vs. 6.82 ± 1.57 mm(2) , P < 0.001), but no significant change in the mean scaffold area (8.49 ± 1.53 mm(2) vs. 8.90 ± 1.51 mm(2) ). Significant decreases in malapposed strut ratio (4.9 ± 8.65% vs. 0.4 ± 1.55%, P < 0.001) and malapposition area (0.29 ± 0.60 mm(2) 0.08 ± 0.32 mm(2) , P = 0.002) were observed. A nonhomogenous proliferation of neointima was revealed with a symmetry index of 0.15 (0.08-0.27), a mean neointima thickness of 203 µm (183-249) and mean neointima area of 2.07 ± 0.51 mm(2) . The quantitative coronary angiography showed late lumen loss of 0.08 ± 0.23 mm and no significant change in the minimal lumen diameter (P = 0.11). There were no major adverse cardiovascular events (MACE), except for one nontarget vessel revascularization. CONCLUSIONS: The OCT revealed a favorable healing pattern after BVS implantation in a STEMI population.


Assuntos
Implantes Absorvíveis , Angiografia Coronária/métodos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/métodos , Tomografia de Coerência Óptica/métodos , Idoso , Estudos de Coortes , Stents Farmacológicos , Eletrocardiografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Intervenção Coronária Percutânea/efeitos adversos , Falha de Prótese , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Fatores de Tempo , Alicerces Teciduais , Resultado do Tratamento , Grau de Desobstrução Vascular/fisiologia
8.
Europace ; 16(5): 750-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24798965

RESUMO

AIMS: Conventional electrocardiogram (ECG)-based diagnosis of left bundle branch block (LBBB) in patients with left ventricular hypertrophy (LVH) is ambiguous. Left ventricular hypertrophy is often seen in patients with severe aortic stenosis in which a transcatheter aortic valve implantation (TAVI) frequently results in a LBBB due to the mechanical interaction of the artificial valve and the conduction system. In this feasibility study, we propose and evaluate the sensitivity of a new electrocardiographic imaging tool; the cardiac isochrone positioning system (CIPS), visualizing the cardiac activation to detect interventricular conduction patterns pre- and post-TAVI. METHODS AND RESULTS: The CIPS translates standard 12-lead ECG into ventricular isochrones, representing the activation sequence. It requires a patient-specific model integrating heart, lungs, and other thoracic structures derived from multi-slice computed tomography. The fastest route-based algorithm was used to estimate the activation isochrones and the results were compared with standard ECG analysis. In 10 patients the CIPS was used to analyse 20 ECGs, 10 pre- and 10 post-TAVI. In 11 cases the CIPS results were in agreement with the ECG-based diagnosis. In two cases there was partial agreement and in seven cases there was disagreement. In four of these cases, the clinical history of the patients favoured interpretation as assessed by CIPS, for the remaining three, it is unknown which method correctly classified the activation. CONCLUSION: This feasibility study applying the CIPS shows promising results to classify conduction disorders originating from the left anterior or posterior ventricular wall, or the septum. The visualization of the activation isochrones as well as ventricular model-derived features might support TAVI procedures and the therapy selection afterwards.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/diagnóstico , Técnicas Eletrofisiológicas Cardíacas/métodos , Processamento de Sinais Assistido por Computador , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Bloqueio de Ramo/complicações , Estudos de Coortes , Eletrocardiografia/métodos , Estudos de Viabilidade , Feminino , Humanos , Hipertrofia Ventricular Esquerda/complicações , Masculino , Estudos Retrospectivos , Sensibilidade e Especificidade , Substituição da Valva Aórtica Transcateter/métodos
9.
Scand Cardiovasc J ; 48(5): 284-90, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25014156

RESUMO

OBJECTIVES: Variability in data acquisition from intervened coronary arteries could represent a source of error that has implications for the design of serial stent studies. We assessed inter-pullback reproducibility of volumetric grayscale and radiofrequency intravascular ultrasound (IVUS) data in stented coronary arteries. DESIGN: Fifteen patients with coronary artery lesions treated with stent implantation were included and examined with two separate pullbacks using the Eagle Eye Gold-phased array 20 MHz IVUS catheter (Volcano). The arteries were divided into five segments, giving a total of 150 sub-segments for analyses. Matching of frames was performed using landmarks that were clearly visible in coronary angiography and intravascular pullbacks. Data were analyzed off-line at an independent Corelab. RESULTS: The inter-pullback reproducibility of geometrical data was very good for non-stented segments with relative differences less than 5% between pullbacks for lumen-, vessel-, and plaque volumes. For stented segments reproducibility was poorer with relative differences between pullbacks in the range of 5-10%. The inter-pullback reproducibility of compositional data demonstrated large standard deviations of relative differences, indicating a weaker agreement. CONCLUSIONS: Agreements between pullbacks were weaker in stented than those in non-stented segments. Based on our data, future longitudinal IVUS studies in intervened vessels should account for a variability of 5-10% attributed to the acquisition of images.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Angina Estável/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Ultrassonografia de Intervenção , Síndrome Coronariana Aguda/terapia , Idoso , Angina Estável/terapia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Reprodutibilidade dos Testes , Stents
10.
Cardiol J ; 31(2): 321-341, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38247435

RESUMO

This paper aims to thoroughly discuss the impact of artificial intelligence (AI) on clinical practice in interventional cardiology (IC) with special recognition of its most recent advancements. Thus, recent years have been exceptionally abundant in advancements in computational tools, including the development of AI. The application of AI development is currently in its early stages, nevertheless new technologies have proven to be a promising concept, particularly considering IC showing great impact on patient safety, risk stratification and outcomes during the whole therapeutic process. The primary goal is to achieve the integration of multiple cardiac imaging modalities, establish online decision support systems and platforms based on augmented and/or virtual realities, and finally to create automatic medical systems, providing electronic health data on patients. In a simplified way, two main areas of AI utilization in IC may be distinguished, namely, virtual and physical. Consequently, numerous studies have provided data regarding AI utilization in terms of automated interpretation and analysis from various cardiac modalities, including electrocardiogram, echocardiography, angiography, cardiac magnetic resonance imaging, and computed tomography as well as data collected during robotic-assisted percutaneous coronary intervention procedures. Thus, this paper aims to thoroughly discuss the impact of AI on clinical practice in IC with special recognition of its most recent advancements.


Assuntos
Inteligência Artificial , Cardiologia , Humanos , Cardiologia/tendências , Doenças Cardiovasculares/terapia , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/diagnóstico por imagem , Intervenção Coronária Percutânea/métodos
11.
Anat Sci Educ ; 16(4): 743-755, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36524288

RESUMO

Tooth anatomy is fundamental knowledge used in everyday dental practice to reconstruct the occlusal surface during cavity fillings. The main objective of this project was to evaluate the suitability of two types of anatomical tooth reference models used to support reconstruction of the occlusal anatomy of the teeth: (1) a three-dimensional (3D)-printed model and (2) a model displayed in augmented reality (AR) using Microsoft HoloLens. The secondary objective was to evaluate three aspects impacting the outcome: clinical experience, comfort of work, and other variables. The tertiary objective was to evaluate the usefulness of AR in dental education. Anatomical models of crowns of three different molars were made using cone beam computed tomography image segmentation, printed with a stereolithographic 3D-printer, and then displayed in the HoloLens. Each participant reconstructed the occlusal anatomy of three teeth. One without any reference materials and two with an anatomical reference model, either 3D-printed or holographic. The reconstruction work was followed by the completion of an evaluation questionnaire. The maximum Hausdorff distances (Hmax) between the superimposed images of the specimens after the procedures and the anatomical models were then calculated. The results showed that the most accurate but slowest reconstruction was achieved with the use of 3D-printed reference models and that the results were not affected by other aspects considered. For this method, the Hmax was observed to be 630 µm (p = 0.004). It was concluded that while AR models can be helpful in dental anatomy education, they are not suitable replacements for physical models.


Assuntos
Anatomia , Realidade Aumentada , Humanos , Impressão Tridimensional , Anatomia/educação , Modelos Anatômicos , Educação em Odontologia
12.
Psychiatr Pol ; 57(2): 325-338, 2023 Apr 30.
Artigo em Inglês, Polonês | MEDLINE | ID: mdl-36371737

RESUMO

OBJECTIVES: Virtual Reality (VR) has been widely used in psychiatry, including psychotic disorders. The main advantage of VR is its high ecological validity and controllability of the virtual environment. Our main goal was to test whether, similarly to computer-generated VR, 360-degree videos are able to elicit a state of social paranoia in prone individuals. METHODS: Sixteen schizophrenia patients and twenty-three healthy individuals were assessed using Leibowitz Social Anxiety Scale and additionally, in the patient group, the Positive and Negative Syndrome Scale (PANSS-6) and Peters Delusional Inventory (PDI) were used. The participants viewed four 360-degree videos with and without social content on a VR headset. Meanwhile, subjects' heart rate was measured continuously. After the exposure, both groups were assessed with Social State Paranoia Scale (SSPS) and asked about momentary anxiety and sense of presence. RESULTS: The schizophrenia patients reported higher momentary anxiety, although the results of SSPS did not differ significantly between groups. In the control group the heart rate decreased between first non-social and social video, whereas in the patient group it did not differ significantly. There was a significant correlation of paranoid ideation experienced on daily basis (PDI) and elicited in VR (SSPS) in the patient group. CONCLUSIONS: In conclusion, paranoid responses can be triggered in patients with schizophrenia by 360-degree videos.


Assuntos
Transtornos Psicóticos , Esquizofrenia , Realidade Virtual , Humanos , Transtornos Paranoides , Projetos Piloto , Esquizofrenia/complicações
13.
Head Face Med ; 18(1): 12, 2022 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-35382839

RESUMO

BACKGROUND: The Augmented Reality (AR) blends digital information with the real world. Thanks to cameras, sensors, and displays it can supplement the physical world with holographic images. Nowadays, the applications of AR range from navigated surgery to vehicle navigation. DEVELOPMENT: The purpose of this feasibility study was to develop an AR holographic system implementing Vertucci's classification of dental root morphology to facilitate the study of tooth anatomy. It was tailored to run on the AR HoloLens 2 (Microsoft) glasses. The 3D tooth models were created in Autodesk Maya and exported to Unity software. The holograms of dental roots can be projected in a natural setting of the dental office. The application allowed to display 3D objects in such a way that they could be rotated, zoomed in/out, and penetrated. The advantage of the proposed approach was that students could learn a 3D internal anatomy of the teeth without environmental visual restrictions. CONCLUSIONS: It is feasible to visualize internal dental root anatomy with AR holographic system. AR holograms seem to be attractive adjunct for learning of root anatomy.


Assuntos
Realidade Aumentada , Holografia , Dente , Estudos de Viabilidade , Holografia/métodos , Humanos , Imageamento Tridimensional , Tecnologia
14.
Cardiol J ; 28(1): 23-33, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32789838

RESUMO

BACKGROUND: General data protection regulation (GDPR) provides rules according to which data should be managed and processed in a secure and appropriate way for patient requirements and security. Currently, everyone in Europe is covered by GDPR. Thus, the medical practice also requires access to patient data in a safe and secure way. METHODS: Holographic technology allows users to see everything visible on a computer screen in a new and less restricted way, i.e. without the limitations of traditional computers and screens. RESULTS: In this study, a three-dimensional holographic doctors' assistant is designed and implemented in a way that meets the GDPR requirements. The HoloView application, which is tailored to run on Microsoft HoloLens, is proposed toallow display and access to personal data and so-called sensitive information of all individual patients without the risk that it will be presented to unauthorized persons. CONCLUSIONS: To enhance the user experience and remain consistent with GSPR, a holographic desk is proposed that allows displaying patient data and sensitive information only in front of the doctor's eyes using mixed reality glasses. Last but not least, it boasts of a reduction in infection risk for the staff during the COVID-19 pandemic, affording medical care to be carried out by as few doctors as possible.


Assuntos
COVID-19/epidemiologia , Segurança Computacional/estatística & dados numéricos , Atenção à Saúde/métodos , Pandemias , SARS-CoV-2 , Realidade Virtual , Europa (Continente)/epidemiologia , Humanos
15.
Materials (Basel) ; 14(19)2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34640238

RESUMO

Various conventional approaches have been reported for the synthesis of nanomaterials without optimizing the role of synthesis parameters. The unoptimized studies not only raise the process cost but also complicate the physicochemical characteristics of the nanostructures. The liquid-plasma reduction with optimized synthesis parameters is an environmentally friendly and low-cost technique for the synthesis of a range of nanomaterials. This work is focused on the statistically optimized production of silver nanoparticles (AgNPs) by using a liquid-plasma reduction process sustained with an argon plasma jet. A simplex centroid design (SCD) was made in Minitab statistical package to optimize the combined effect of stabilizers on the structural growth and UV absorbance of AgNPs. Different combinations of glucose, fructose, sucrose and lactose stabilizers were tested at five different levels (-2, -1, 0, 1, 2) in SCD. The effect of individual and mixed stabilizers on AgNPs growth parameters was assumed significant when p-value in SCD is less than 0.05. A surface plasmon resonance band was fixed at 302 nm after SCD optimization of UV results. A bond stretching at 1633 cm-1 in FTIR spectra was assigned to C=O, which slightly shifts towards a larger wavelength in the presence of saccharides in the solution. The presence of FCC structured AgNPs with an average size of 15 nm was confirmed from XRD and EDX spectra under optimized conditions. The antibacterial activity of these nanoparticles was checked against Staphylococcus aureus and Escherichia coli strains by adopting the shake flask method. The antibacterial study revealed the slightly better performance of AgNPs against Staph. aureus strain than Escherichia coli.

16.
Am J Cardiol ; 155: 23-31, 2021 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-34315572

RESUMO

Data on long-term neointimal healing and neoatherosclerosis progression after primary percutaneous coronary intervention (PCI) with implantation of everolimus-eluting bioresorbable vascular scaffold (BVS) (ABSORB BVS 1.0, Abbott Vascular) are limited. The mechanisms underlying very late scaffold failure remain to be further elucidated. This study sought to assess healing pattern and presence of neoatherosclerosis. This was a single-center, prospective, longitudinal study with serial optical coherence tomography (OCT) assessment at baseline, 12, 24 and 60 months after PCI performed in 12 patients presenting with ST-segment elevation myocardial infarction (STEMI). The median follow-up was 59 months. The diameter stenosis increased from 7.11 ± 4.99% at 1-year to 21.00 ± 11.31% at 5 years, (p = 0.03), whereas minimum lumen diameter remained stable throughout the follow-up period, as assessed by angiography. Minimum and mean lumen area declined over the 5-year follow-up by 1.00 ± 1.57 mm2 and 1.75 ± 0.87 mm2, respectively; a significant decrease in minimum and mean lumen area in the first two years, was followed by stable luminal dimensions between 2 and 5 years of follow-up. The lumen eccentricity (0.85 ± 0.03) and asymmetry (0.43 ± 0.10) indexes showed no change over 60-month follow-up. The incidence of atherosclerosis was high both in the in-scaffold (IS) and out-scaffold (OS) regions consisting of calcifications (IS = 100%, OS = 92%, p = 0.99), macrophages (IS = 92% and OS = 67%, p = 0.31), neovascularization (IS = 75%, OS = 50%, p = 0.40). In conclusion, serial OCT imaging up to 5 years after implantation of BVS in STEMI indicated complete scaffold resorption, stable lumen area following period of neointima growth in the first two years after PCI and high incidence of neoatherosclerosis.


Assuntos
Implantes Absorvíveis , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Alicerces Teciduais , Tomografia de Coerência Óptica/métodos , Angiografia Coronária , Vasos Coronários/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Fatores de Tempo , Resultado do Tratamento
17.
Int J Cardiol ; 312: 27-32, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32315682

RESUMO

BACKGROUND: Peri-strut low intensity areas (PLIA) visualized by optical coherence tomography (OCT) have been related to neointimal proliferation and increased incidence of target lesion revascularization in stable coronary artery disease. The aim of this study was to determine the association between PLIA by OCT and the long-term vascular healing response after bioresorbable scaffold (BRS) implantation in the setting of ST-segment elevation myocardial infarction (STEMI). METHODS: This is a single-centre, longitudinal, cohort study with a serial: baseline, 1, 2 and 5 years OCT evaluation of neointimal response (lumen area and neoatherosclerosis) after percutaneous coronary intervention (PCI) with BRS Absorb™ 1.0 implantation in patients presenting with STEMI. PLIA was analyzed in every cross section and scored: 0-no PLIA; 1-PLIA < 1 quadrant; 2-PLIA ≥ 1 and <2 quadrants; 3-PLIA ≥ 2 and <3 quadrants; 4-PLIA in ≥3 quadrants. RESULTS: Of the 23 patients implanted BRS, 18 completed 2-year follow-up, whereas complete OCT data up to 5 years were available in 12 patients. Presence of PLIA was identified in 100% patients at 1 and 2 years, whereas at 5 years neither PLIA nor scaffold struts were visualized by OCT. Neoatherosclerosis was identified in 73,68% patients after 1 year and in all patients at 2 and 5 years. The mean PLIA score > 1 at 2 years was associated with greater percentage of minimum lumen area decrease after 2 years from index procedure. CONCLUSIONS: The extent of PLIA by OCT at 2 years after primary PCI with BRS was associated with lumen area decrease. Neoatherosclerosis formation was detected in all patients at 2 and 5 years. PLIA assessment could serve as an additive means to predict neointimal healing pattern after next generation BRS implantation.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Implantes Absorvíveis , Estudos de Coortes , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Neointima/diagnóstico por imagem , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Tomografia de Coerência Óptica , Resultado do Tratamento
18.
Comput Methods Programs Biomed ; 182: 105052, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31476448

RESUMO

BACKGROUND AND OBJECTIVE: People suffer from sleep disorders caused by work-related stress, irregular lifestyle or mental health problems. Therefore, development of effective tools to diagnose sleep disorders is important. Recently, to analyze biomedical signals Information Theory is exploited. We propose efficient classification method of sleep anomalies by applying entropy estimating algorithms to encoded ECGs signals coming from patients suffering from Sleep-Related Breathing Disorders (SRBD). METHODS: First, ECGs were discretized using the encoding method which captures the biosignals variability. It takes into account oscillations of ECG measurements around signals averages. Next, to estimate entropy of encoded signals Lempel-Ziv complexity algorithm (LZ) which measures patterns generation rate was applied. Then, optimal encoding parameters, which allow distinguishing normal versus abnormal events during sleep with high sensitivity and specificity were determined numerically. Simultaneously, subjects' states were identified using acoustic signal of breathing recorded in the same period during sleep. RESULTS: Random sequences show normalized LZ close to 1 while for more regular sequences it is closer to 0. Our calculations show that SRBDs have normalized LZ around 0.32 (on average), while control group has complexity around 0.85. The results obtained to public database are similar, i.e. LZ for SRBDs around 0.48 and for control group 0.7. These show that signals within the control group are more random whereas for the SRBD group ECGs are more deterministic. This finding remained valid for both signals acquired during the whole duration of experiment, and when shorter time intervals were considered. Proposed classifier provided sleep disorders diagnostics with a sensitivity of 93.75 and specificity of 73.00%. To validate our method we have considered also different variants as a training and as testing sets. In all cases, the optimal encoding parameter, sensitivity and specificity values were similar to our results above. CONCLUSIONS: Our pilot study suggests that LZ based algorithm could be used as a clinical tool to classify sleep disorders since the LZ complexities for SRBD positives versus healthy individuals show a significant difference. Moreover, normalized LZ complexity changes are related to the snoring level. This study also indicates that LZ technique is able to detect sleep abnormalities in early disorders stage.


Assuntos
Eletrocardiografia/métodos , Transtornos do Sono-Vigília/fisiopatologia , Algoritmos , Humanos , Processamento de Sinais Assistido por Computador , Transtornos do Sono-Vigília/classificação
19.
Int J Cardiovasc Imaging ; 35(1): 9-21, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30168010

RESUMO

Early-generation drug-eluting stents (DES) have been demonstrated to delay vascular healing. Limited optical coherence tomography (OCT) data on the very long-term neointimal response after DES implantation are available. The aim of this study was a serial OCT assessment of neointimal thickness, stent strut coverage, malapposition, and protrusion as markers of neointimal response at 3 and 9 years after implantation of sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES). In this single-centre, longitudinal study consecutive patients undergoing elective PCI with SES or PES were included. OCT analysis was performed after 3 and 9 years by the independent core laboratory. A total of 22 subjects (8 SES and 14 PES) underwent an OCT assessment at 3 and 9 years post index procedure. The lumen, neointimal and malapposition area and the neointimal thickness (SES ∆50 µm, p = 0.195, PES ∆10 µm, p = 0.951) did not change significantly over the 6 year follow-up. No differences in the incidence of uncovered, malapposed or protruding struts were found in each type of stent. At 3 and 9 years after PCI, implantation of early-generation SES and PES may be associated with similar neointimal thickness, strut coverage, malapposition and protrusion, as assessed by serial OCT examination among patients with uneventful follow-up at 3 years post procedure. The small size of the study warrants judicious interpretation of our results and confirmation in larger multimodality imaging studies, including patients treated with contemporary stent platforms.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/cirurgia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica , Cicatrização/efeitos dos fármacos , Idoso , Fármacos Cardiovasculares/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Neointima , Variações Dependentes do Observador , Paclitaxel/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
20.
Int J Cardiovasc Imaging ; 35(2): 215-223, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30796556

RESUMO

The aim of this study was to compare the measures of luminal stenosis between the two-dimensional (2D) and three-dimensional (3D) Quantitative Vessel Analysis (QVA) generated by CAAS QVA software and intravascular ultrasound (IVUS). Invasive contrast angiography is considered gold standard for diagnostic imaging and intervention in both coronary and peripheral arterial disease. However, it is based on 2D images depicting complicated 3D arterial anatomy. To overcome these limitations, 3D QVA has been developed to bridge the gap between 2D QVA and endovascular imaging. Thirty porcine femoral angiograms (common, profunda and superficial) with matching intravascular ultrasound (IVUS) pullbacks featuring variable degree of stenosis were analysed by 2D QVA, 3D QVA and quantitative IVUS. All 3 modalities provided similar data regarding the length of the investigated segment. Median lumen diameter was nearly identical in IVUS (4.69 mm) and in 3D QVA (4.76 mm) but quite a bit lower in 2D QVA (4.47 mm, Kruskal-Wallis test p = 0.1648). Lumen area measured in 2D QVA was lower than in IVUS and in 3D QVA. Lumen areas rendered by IVUS and 3D QVA were similar. Bland-Altman plots showed that the lowest differences were observed between IVUS and 3D QVA. IVUS and 3D QVA results were consistently higher than 2D QVA. 3D QVA is a useful surrogate of IVUS for precise luminal morphology measurements of peripheral arteries, rendering results that are much closer to IVUS than 2D QVA can provide.


Assuntos
Angiografia/métodos , Artéria Femoral/diagnóstico por imagem , Imageamento Tridimensional/métodos , Doença Arterial Periférica/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Ultrassonografia de Intervenção , Animais , Constrição Patológica , Modelos Animais de Doenças , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Sus scrofa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA