Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Magn Reson Med ; 85(2): 721-733, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32754969

RESUMO

PURPOSE: 4D flow magnetic resonance imaging (4D-MRI) allows time-resolved visualization of blood flow patterns, quantification of volumes, velocities, and advanced parameters, such as wall shear stress (WSS). As 4D-MRI enters the clinical arena, standardization and awareness of confounders are important. Our aim was to evaluate the equivalence of 4D flow-derived aortic hemodynamics in healthy volunteers using different sequences and field strengths. METHODS: 4D-MRI was acquired in 10 healthy volunteers at 1.5T using three different prototype sequences, at 3T and at 7T (Siemens Healthineers). After evaluation of diagnostic quality in three segments (ascending-, descending aorta, aortic arch), peak velocity, flow volumes, and WSS were investigated. Equivalence limits for comparison of field strengths/sequences were based on the limits of Bland-Altman analyses of the intraobserver variability. RESULTS: Non-diagnostic quality was found in 10/144 segments, 9/10 were obtained at 7T. Apart for the comparison of forward flow between sequence 1 and 3, the differences in measurements between field strengths/sequences exceeded the range of agreement. Significant differences were found between field strengths/sequences for forward flow (1.5T vs. 3T, 3T vs. 7T, sequence 1 vs. 3, 2 vs. 3 [P < .001]), WSS (1.5T vs. 3T [P < .05], sequence 1 vs. 2, 1 vs. 3, 2 vs. 3 [P < .001]), and peak velocity (1.5T vs. 7T, sequence 1 vs. 3 [P > .001]). All parameters at all field strengths/with all sequences correlated moderately to strongly (r ≥ 0.5). CONCLUSION: Data from all sequences could be acquired and resulting images showed sufficient quality for further analysis. However, the variability of the measurements of peak velocity, flow volumes, and WSS was higher when comparing field strengths/sequences as the equivalence limits defined by the intraobserver assessments.


Assuntos
Aorta , Imageamento por Ressonância Magnética , Aorta/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Voluntários Saudáveis , Hemodinâmica , Humanos , Imageamento Tridimensional
2.
J Cardiovasc Magn Reson ; 20(1): 13, 2018 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-29458430

RESUMO

BACKGROUND: Segmented phase-sensitive inversion recovery (PSIR) cardiovascular magnetic resonance (CMR) sequences are reference standard for non-invasive evaluation of myocardial fibrosis using late gadolinium enhancement (LGE). Several multi-slice LGE sequences have been introduced for faster acquisition in patients with arrhythmia and insufficient breathhold capability. The aim of this study was to assess the accuracy of several multi-slice LGE sequences to detect and quantify myocardial fibrosis in patients with ischemic and non-ischemic myocardial disease. METHODS: Patients with known or suspected LGE due to chronic infarction, inflammatory myocardial disease and hypertrophic cardiomyopathy (HCM) were prospectively recruited. LGE images were acquired 10-20 min after administration of 0.2 mmol/kg gadolinium-based contrast agent. Three different LGE sequences were acquired: a segmented, single-slice/single-breath-hold fast low angle shot PSIR sequence (FLASH-PSIR), a multi-slice balanced steady-state free precession inversion recovery sequence (bSSFP-IR) and a multi-slice bSSFP-PSIR sequence during breathhold and free breathing. Image quality was evaluated with a 4-point scoring system. Contrast-to-noise ratios (CNR) and acquisition time were evaluated. LGE was quantitatively assessed using a semi-automated threshold method. Differences in size of fibrosis were analyzed using Bland-Altman analysis. RESULTS: Three hundred twelve patients were enrolled (n = 212 chronic infarction, n = 47 inflammatory myocardial disease, n = 53 HCM) Of which 201 patients (67,4%) had detectable LGE (n = 143 with chronic infarction, n = 27 with inflammatory heart disease and n = 31 with HCM). Image quality and CNR were best on multi-slice bSSFP-PSIR. Acquisition times were significantly shorter for all multi-slice sequences (bSSFP-IR: 23.4 ± 7.2 s; bSSFP-PSIR: 21.9 ± 6.4 s) as compared to FLASH-PSIR (361.5 ± 95.33 s). There was no significant difference of mean LGE size for all sequences in all study groups (FLASH-PSIR: 8.96 ± 10.64 g; bSSFP-IR: 8.69 ± 10.75 g; bSSFP-PSIR: 9.05 ± 10.84 g; bSSFP-PSIR free breathing: 8.85 ± 10.71 g, p > 0.05). LGE size was not affected by arrhythmia or absence of breathhold on multi-slice LGE sequences. CONCLUSIONS: Fast multi-slice and standard segmented LGE sequences are equivalent techniques for the assessment of myocardial fibrosis, independent of an ischemic or non-ischemic etiology. Even in patients with arrhythmia and insufficient breathhold capability, multi-slice sequences yield excellent image quality at significantly reduced scan time and may be used as standard LGE approach. TRIAL REGISTRATION: ISRCTN48802295 (retrospectively registered).


Assuntos
Cardiomiopatias/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Compostos Heterocíclicos/administração & dosagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Miocardite/diagnóstico por imagem , Compostos Organometálicos/administração & dosagem , Adulto , Idoso , Cardiomiopatias/patologia , Cardiomiopatias/fisiopatologia , Feminino , Fibrose , Gadolínio/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Miocardite/patologia , Miocardite/fisiopatologia , Miocárdio/patologia , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
3.
Magn Reson Med ; 77(6): 2381-2389, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27342430

RESUMO

PURPOSE: Myocardial effective relaxation time T2* is commonly regarded as a surrogate for myocardial tissue oxygenation. However, it is legitimate to assume that there are multiple factors that influence T2*. To this end, this study investigates the relationship between T2* and cardiac macromorphology given by left ventricular (LV) wall thickness and left ventricular radius, and provides interpretation of the results in the physiological context. METHODS: High spatio-temporally resolved myocardial CINE T2* mapping was performed in 10 healthy volunteers using a 7.0 Tesla (T) full-body MRI system. Ventricular septal wall thickness, left ventricular inner radius, and T2* were analyzed. Macroscopic magnetic field changes were elucidated using cardiac phase-resolved magnetic field maps. RESULTS: Ventricular septal T2* changes periodically over the cardiac cycle, increasing in systole and decreasing in diastole. Ventricular septal wall thickness and T2* showed a significant positive correlation, whereas the inner LV radius and T2* were negatively correlated. The effect of macroscopic magnetic field gradients on T2* can be considered minor in the ventricular septum. CONCLUSION: Our findings suggest that myocardial T2* is related to tissue blood volume fraction. Temporally resolved T2* mapping could be beneficial for myocardial tissue characterization and for understanding cardiac (patho)physiology in vivo. Magn Reson Med 77:2381-2389, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Adulto , Feminino , Humanos , Masculino , Tamanho do Órgão/fisiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Cardiovasc Magn Reson ; 18(1): 58, 2016 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-27660042

RESUMO

BACKGROUND: T1 mapping and extracellular volume (ECV) have the potential to guide patient care and serve as surrogate end-points in clinical trials, but measurements differ between cardiovascular magnetic resonance (CMR) scanners and pulse sequences. To help deliver T1 mapping to global clinical care, we developed a phantom-based quality assurance (QA) system for verification of measurement stability over time at individual sites, with further aims of generalization of results across sites, vendor systems, software versions and imaging sequences. We thus created T1MES: The T1 Mapping and ECV Standardization Program. METHODS: A design collaboration consisting of a specialist MRI small-medium enterprise, clinicians, physicists and national metrology institutes was formed. A phantom was designed covering clinically relevant ranges of T1 and T2 in blood and myocardium, pre and post-contrast, for 1.5 T and 3 T. Reproducible mass manufacture was established. The device received regulatory clearance by the Food and Drug Administration (FDA) and Conformité Européene (CE) marking. RESULTS: The T1MES phantom is an agarose gel-based phantom using nickel chloride as the paramagnetic relaxation modifier. It was reproducibly specified and mass-produced with a rigorously repeatable process. Each phantom contains nine differently-doped agarose gel tubes embedded in a gel/beads matrix. Phantoms were free of air bubbles and susceptibility artifacts at both field strengths and T1 maps were free from off-resonance artifacts. The incorporation of high-density polyethylene beads in the main gel fill was effective at flattening the B 1 field. T1 and T2 values measured in T1MES showed coefficients of variation of 1 % or less between repeat scans indicating good short-term reproducibility. Temperature dependency experiments confirmed that over the range 15-30 °C the short-T1 tubes were more stable with temperature than the long-T1 tubes. A batch of 69 phantoms was mass-produced with random sampling of ten of these showing coefficients of variations for T1 of 0.64 ± 0.45 % and 0.49 ± 0.34 % at 1.5 T and 3 T respectively. CONCLUSION: The T1MES program has developed a T1 mapping phantom to CE/FDA manufacturing standards. An initial 69 phantoms with a multi-vendor user manual are now being scanned fortnightly in centers worldwide. Future results will explore T1 mapping sequences, platform performance, stability and the potential for standardization.

5.
J Heart Valve Dis ; 25(5): 527-533, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-28238233

RESUMO

BACKGROUND: Continuous pressure overload may lead to subclinical myocardial tissue changes in patients with hypertensive heart disease (HHD) and aortic stenosis (AS). The study aim was to detect interstitial fibrosis using quantitative cardiovascular magnetic resonance. METHODS: Fifteen patients with HHD (arterial hypertension + septal wall thickness ≥13 mm), 33 with AS (eight mild, 15 moderate, 10 severe), and 60 healthy controls were enrolled. Native T1 maps (modified Look-Locker inversion recovery) were obtained in a basal, mid-ventricular, and apical shortaxis slice of the left ventricle to assess cardiac fibrosis. Focal fibrosis was assessed with late gadolinium enhancement (LGE). RESULTS: Patients with HHD and controls did not differ regarding the native myocardial T1 values, both per slice and per segment. In AS patients, apical native T1 values were lower than in controls, and there was a trend towards higher T1 values in the septum in severe AS (1172.6 ± 62.0 ms versus 1152.9 ± 43.9 ms). Five HHD patients and 11 AS patients had non-ischemic fibrosis in LGE images. Native T1 times did not differ between LGE-positive and LGEnegative groups (both with inclusion and exclusion of segments with LGE). CONCLUSIONS: T1 mapping did not reveal any evidence of abnormal interstitial fibrosis in HHD subjects with mild hypertrophy. In severe AS, a trend towards more interstitial fibrosis was present, but absolute differences were small for decision making.


Assuntos
Estenose da Valva Aórtica/patologia , Cardiopatias/patologia , Hipertensão/patologia , Miocárdio/patologia , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Fibrose , Coração/diagnóstico por imagem , Cardiopatias/diagnóstico por imagem , Humanos , Hipertensão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
6.
BMC Med Imaging ; 16: 35, 2016 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-27129879

RESUMO

BACKGROUND: Studying T1- and T2-mapping for discrimination of acute from chronic myocardial infarction (AMI, CMI). METHODS: Eight patients with AMI underwent CMR at 3 T acutely and after >3 months. Imaging techniques included: T2-weighted imaging, late enhancement (LGE), T2-mapping, native and post-contrast T1-mapping. Myocardial T2- and T1-relaxation times were determined for every voxel. Abnormal voxels as defined by having T2- and T1-values beyond a predefined threshold (T2 > 50 ms, native T1 > 1250 ms and post-contrast T1 < 350 ms) were highlighted and compared with LGE as the reference. RESULTS: Abnormal T2-relaxation times were present in the voxels with AMI (=> delete acute infarction; unfortunately this is not possible in your web interface) acute infarction only in half of the subjects. Abnormal T2-values were also present in subjects with CMI, thereby matching the chronically infarcted territory in some. Abnormal native T1 times were present in voxels with AMI in 5/8 subjects, but also remote from the infarcted territory in four. In CMI, abnormal native T1 values corresponded with infarcted voxels, but were also abnormal remote from the infarcted territory. Voxels with abnormal post-contrast T1-relaxation times agreed well with LGE in AMI and CMI. CONCLUSIONS: In this pilot-study, T2- and T1-mapping with simple thresholds did not facilitate the discrimination of AMI and CMI.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/patologia , Adulto , Idoso , Meios de Contraste/metabolismo , Diagnóstico Diferencial , Gadolínio DTPA/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
7.
J Magn Reson Imaging ; 39(5): 1153-60, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24151119

RESUMO

PURPOSE: To compare whether the higher relaxivity contrast agent gadobenate is superior for the identification of nonischemic late gadolinium enhancement (LGE) in hypertrophic cardiomyopathy (HCM) compared to standard relaxivity agents such as gadopentetate. MATERIALS AND METHODS: Fifteen patients with HCM and positive LGE based on routine cardiac magnetic resonance (CMR) with 0.2 mmol/kg gadopentetate were enrolled. Each patient thereafter underwent a second enhanced CMR exam with 0.2 mmol/kg gadobenate using the same CMR protocol. LGE was assessed in a short axis stack acquired after contrast administration using an inversion recovery gradient echo sequence. Two independent blinded readers quantified LGE by manual planimetry. The signal intensities of injured myocardium, remote myocardium, left ventricular cavity, and air were measured in identical locations using anatomical landmarks and dedicated software. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. RESULTS: No adverse events related to contrast administration occurred. Gadobenate dimeglumine showed a higher SNR of injured myocardium (45.4 ± 24.0 vs. 31.1 ± 16.6, P = 0.002) and a higher CNR between remote and injured myocardium (37.6 ± 25.0 vs. 26.5 ± 17.6, P = 0.006) compared to gadopentetate dimeglumine. The amount of LGE (based on the same postprocessing criteria and definitions) was higher with gadobenate dimeglumine (12.7 ± 8.5 g vs. 9.4 ± 5.6 g, P = 0.005). There was no difference in intra- and interobserver variability between gadopentetate dimeglumine and gadobenate dimeglumine. CONCLUSION: CMR with the high relaxivity contrast agent gadobenate dimeglumine reveals significantly more tissue with LGE in patients with HCM.


Assuntos
Cardiomiopatia Hipertrófica/patologia , Gadolínio DTPA , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Meios de Contraste , Feminino , Fibrose , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/patologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico , Adulto Jovem
8.
J Cardiovasc Magn Reson ; 15: 27, 2013 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-23537111

RESUMO

BACKGROUND: The aim of the study was to test the reproducibility and variability of myocardial T2 mapping in relation to sequence type and spatial orientation in a large group of healthy volunteers. For control T2 mapping was also applied in patients with true edema. Cardiovascular magnetic resonance (CMR) T2-mapping has potential for the detection and quantification of myocardial edema. Clinical experience is limited so far. The variability and potential pitfalls in broad application are unknown. METHODS: Healthy volunteers (n = 73, 35 ± 13 years) and patients with edema (n = 28, 55 ± 17 years) underwent CMR at 1.5 T. Steady state free precession (SSFP) cine loops and T2-weighted spin echo images were obtained. In patients, additionally late gadolinium enhancement images were acquired. We obtained T2 maps in midventricular short axis (SAX) and four-chamber view (4CV) based on images with T2 preparation times of 0, 24, 55 ms and compared fast low angle shot (FLASH) and SSFP readout. 10 volunteers were scanned twice on separate days. Two observers analysed segmental and global T2 per slice. RESULTS: In volunteers global myocardial T2 systematically differed depending on image orientation and sequence (FLASH 52 ± 5 vs. SSFP 55 ± 5 ms in SAX and 57 ± 6 vs. 59 ± 6 ms in 4CV; p < 0.0001 for both). Anteroseptal and apical segments had higher T2 than inferior and basal segments (SAX: 59 ± 6 vs. 48 ± 5 ms for FLASH and 59 ± 7 vs. 52 ± 4 ms for SSFP; p < 0.0001 for both). 14 volunteers had segments with T2 ≥ 70 ms. Mean intraobserver variability was 1.07 ± 1.03 ms (r = 0.94); interobserver variability was 1.6 ± 1.5 ms (r = 0.87). The coefficient of variation for repeated scans was 7.6% for SAX and 6.6% for 4CV. Mapping revealed focally increased T2 (73 ± 9 vs. 51 ± 3 ms in remote myocardium; p < 0.0001) in all patients with edema. CONCLUSIONS: Myocardial T2 mapping is technically feasible and highly reproducible. It can detect focal edema and differentiate it from normal myocardium. Increased T2 was found in some volunteers most likely due to partial volume and residual motion.


Assuntos
Edema Cardíaco/diagnóstico , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Estudos de Casos e Controles , Meios de Contraste , Edema Cardíaco/patologia , Estudos de Viabilidade , Feminino , Gadolínio DTPA , Humanos , Imagem Cinética por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Adulto Jovem
9.
J Cardiovasc Magn Reson ; 15: 53, 2013 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-23777327

RESUMO

BACKGROUND: Myocardial T1 and T2 mapping using cardiovascular magnetic resonance (CMR) are promising to improve tissue characterization and early disease detection. This study aimed at analyzing the feasibility of T1 and T2 mapping at 3 T and providing reference values. METHODS: Sixty healthy volunteers (30 males/females, each 20 from 20-39 years, 40-59 years, 60-80 years) underwent left-ventricular T1 and T2 mapping in 3 short-axis slices at 3 T. For T2 mapping, 3 single-shot steady-state free precession (SSFP) images with different T2 preparation times were acquired. For T1 mapping, modified Look-Locker inversion recovery technique with 11 single shot SSFP images was used before and after injection of gadolinium contrast. T1 and T2 relaxation times were quantified for each slice and each myocardial segment. RESULTS: Mean T2 and T1 (pre-/post-contrast) times were: 44.1 ms/1157.1 ms/427.3 ms (base), 45.1 ms/1158.7 ms/411.2 ms (middle), 46.9 ms/1180.6 ms/399.7 ms (apex). T2 and pre-contrast T1 increased from base to apex, post-contrast T1 decreased. Relevant inter-subject variability was apparent (scatter factor 1.08/1.05/1.11 for T2/pre-contrast T1/post-contrast T1). T2 and post-contrast T1 were influenced by heart rate (p < 0.0001, p = 0.0020), pre-contrast T1 by age (p < 0.0001). Inter- and intra-observer agreement of T2 (r = 0.95; r = 0.95) and T1 (r = 0.91; r = 0.93) were high. T2 maps: 97.7% of all segments were diagnostic and 2.3% were excluded (susceptibility artifact). T1 maps (pre-/post-contrast): 91.6%/93.9% were diagnostic, 8.4%/6.1% were excluded (predominantly susceptibility artifact 7.7%/3.2%). CONCLUSIONS: Myocardial T2 and T1 reference values for the specific CMR setting are provided. The diagnostic impact of the high inter-subject variability of T2 and T1 relaxation times requires further investigation.


Assuntos
Interpretação de Imagem Assistida por Computador/normas , Imagem Cinética por Ressonância Magnética/normas , Função Ventricular Esquerda , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Artefatos , Calibragem , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Valores de Referência , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto Jovem
10.
Eur Radiol ; 20(12): 2844-52, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20640427

RESUMO

OBJECTIVES: Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T. METHODS: A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated. RESULTS: All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm. CONCLUSIONS: This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Ventrículos do Coração/anatomia & histologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
11.
J Cardiovasc Magn Reson ; 12: 67, 2010 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-21080933

RESUMO

BACKGROUND: To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms. RESULTS: ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms.Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34). CONCLUSIONS: The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Oximetria , Fonocardiografia , Vetorcardiografia , Função Ventricular Esquerda , Adulto , Artefatos , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Adulto Jovem
12.
Sci Rep ; 8(1): 3974, 2018 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-29507338

RESUMO

Hypertrophic cardiomyopathy (HCM) is the most common genetic disease of the myocardium and bares the risk of progression to heart failure or sudden cardiac death. Identifying patients at risk remains an unmet need. Recognizing the dependence of microscopic susceptibility on tissue microstructure and on cardiac macromorphology we hypothesized that myocardial T2* might be altered in HCM patients compared to healthy controls. To test this hypothesis, myocardial T2*-mapping was conducted at 7.0 Tesla to enhance T2*-contrast. 2D CINE T2*-mapping was performed in healthy controls and HCM patients. To ensure that T2* is not dominated by macroscopic magnetic field inhomogeneities, volume selective B0 shimming was applied. T2* changes in the interventricular septum across the cardiac cycle were analyzed together with left ventricular radius and ventricular septal wall thickness. The results show that myocardial T2* is elevated throughout the cardiac cycle in HCM patients compared to healthy controls. A mean septal T2* = 13.7 ± 1.1 ms (end-systole: T2*,systole = 15.0 ± 2.1, end-diastole: T2*,diastole = 13.4 ± 1.3 ms, T2*,systole/T2*,diastole ratio = 1.12) was observed in healthy controls. For HCM patients a mean septal T2* = 17.4 ± 1.4 ms (end-systole: T2*,systole = 17.7 ± 1.2 ms, end-diastole: T2*,diastole = 16.2 ± 2.5 ms, T2*,systole/T2*,diastole ratio = 1.09) was found. Our preliminary results provide encouragement that assessment of T2* and its changes across the cardiac cycle may benefit myocardial tissue characterization in HCM.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Cardiomiopatia Hipertrófica/fisiopatologia , Diástole , Feminino , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Sístole
13.
J Thorac Imaging ; 31(6): 336-347, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27007666

RESUMO

Infiltrative cardiomyopathies are a heterogenous group of diseases that typically lead to restrictive cardiac dysfunction. Due to similar phenotypes, accurate diagnosis is challenging without invasive endomyocardial biopsy which has historically been considered mandatory. Cardiac magnetic resonance (CMR) has been well established in the diagnostic workup of patients with suspected cardiomyopathies due to its unique capability for tissue differentiation and its unsurpassed accuracy in defining cardiac morphology and function. The increasing variety of CMR techniques has generated both excitement and uncertainty with regard to their potential clinical use and its role vis-à-vis conventional noninvasive imaging techniques. The purpose of this review is to give an overview of established and emerging CMR techniques and typical image characteristics of the most commonly encountered infiltrative cardiomyopathies.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Humanos
14.
Interact Cardiovasc Thorac Surg ; 22(1): 38-46, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26487434

RESUMO

OBJECTIVES: Pectus excavatum (PE) is often regarded as a cosmetic disease, while its effect on cardiac function is under debate. Data regarding cardiac function before and after surgical correction of PE are limited. We aimed to assess the impact of surgical correction of PE on cardiac function by cardiovascular magnetic resonance (CMR). METHODS: CMR at 1.5 T was performed in 38 patients (mean age 21 ± 8.3; 31 men) before and after surgical correction to evaluate thoracic morphology, indices and its relation to three-dimensional left and right ventricular cardiac function. RESULTS: Surgery was successful in all patients as shown by the Haller Index ratio of maximum transverse diameter of the chest wall and minimum sternovertebral distance [pre: 9.64 (95% CI 8.18-11.11) vs post: 3.0 (2.84-3.16), P < 0.0001]. Right ventricular ejection fraction (RVEF) was reduced before surgery and improved significantly at the 1-year follow-up [pre: 45.7% (43.9-47.4%) vs 48.3% (46.9-49.5%), P = 0.0004]. Left ventricular ejection fraction was normal before surgery, but showed a further improvement after 1 year [pre: 61.0% (59.3-62.7%) vs 62.7% (61.3-64.2%), P = 0.0165]. Cardiac compression and the asymmetry index changed directly after surgery and were stable at the 1-year follow-up [3.93 (3.53-4.33) vs 2.08 (1.98-2.19) and 2.36 (2.12-2.59) vs 1.38 (1.33-1.44), respectively; P < 0.0001 for both]. None of the obtained thoracic indices were predictors of the improvement of cardiac function. A reduced preoperative RVEF was predictive of RVEF improvement. CONCLUSIONS: PE is associated with reduced RVEF, which improves after surgical correction. CMR has the capability of offering additional information prior to surgical correction.


Assuntos
Tórax em Funil/cirurgia , Ventrículos do Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Masculino , Fatores de Tempo , Adulto Jovem
15.
PLoS One ; 11(2): e0148066, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26863618

RESUMO

BACKGROUND: Cardiovascular Magnetic Resonance (CMR) provides valuable information in patients with hypertrophic cardiomyopathy (HCM) based on myocardial tissue differentiation and the detection of small morphological details. CMR at 7.0T improves spatial resolution versus today's clinical protocols. This capability is as yet untapped in HCM patients. We aimed to examine the feasibility of CMR at 7.0T in HCM patients and to demonstrate its capability for the visualization of subtle morphological details. METHODS: We screened 131 patients with HCM. 13 patients (9 males, 56 ±31 years) and 13 healthy age- and gender-matched subjects (9 males, 55 ±31years) underwent CMR at 7.0T and 3.0T (Siemens, Erlangen, Germany). For the assessment of cardiac function and morphology, 2D CINE imaging was performed (voxel size at 7.0T: (1.4x1.4x2.5) mm3 and (1.4x1.4x4.0) mm3; at 3.0T: (1.8x1.8x6.0) mm3). Late gadolinium enhancement (LGE) was performed at 3.0T for detection of fibrosis. RESULTS: All scans were successful and evaluable. At 3.0T, quantification of the left ventricle (LV) showed similar results in short axis view vs. the biplane approach (LVEDV, LVESV, LVMASS, LVEF) (p = 0.286; p = 0.534; p = 0.155; p = 0.131). The LV-parameters obtained at 7.0T where in accordance with the 3.0T data (pLVEDV = 0.110; pLVESV = 0.091; pLVMASS = 0.131; pLVEF = 0.182). LGE was detectable in 12/13 (92%) of the HCM patients. High spatial resolution CINE imaging at 7.0T revealed hyperintense regions, identifying myocardial crypts in 7/13 (54%) of the HCM patients. All crypts were located in the LGE-positive regions. The crypts were not detectable at 3.0T using a clinical protocol. CONCLUSIONS: CMR at 7.0T is feasible in patients with HCM. High spatial resolution gradient echo 2D CINE imaging at 7.0T allowed the detection of subtle morphological details in regions of extended hypertrophy and LGE.


Assuntos
Cardiomiopatia Hipertrófica/patologia , Ventrículos do Coração/patologia , Processamento de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Idoso , Estudos de Casos e Controles , Ecocardiografia , Feminino , Fibrose/patologia , Gadolínio/química , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA